
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
INSTALLATION INSTRUCTIONS -02--03--01- DESCRIPTION FEATURES ZWN-RSM1S Voltage.........................................................................120-277VAC, 50/60Hz Maximum Load requirement.....................................................................10A Range.................................................................Up to 100 feet line of sight SPECIFICATIONS between the Wireless Controller and the closest Z-Wave receiver module. INSTALLATION device is designed to act as a wireless repeater. Once the ZWN-RSM1S module switch. This ZWN-RSM1S module is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. In a Z-Wave network, each intended device is reached. This ensures that the signal is received by its intended destination by routing the signal around Wiring Diagram 1: IMPORTANT NOTE ABOUT 3-WAY CIRCUITS The term “3-way circuit” refers to a circuit with two switches and one load (light) like you find at the top and bottom of a stairway. There are many ways to physically wire a 3-way circuit and it is important to understand how the circuit you wish to upgrade to Z-Wave control is wired. Below is a description of a typical 3-way circuit. One of the ways to wire a two-switch/one-load circuit is to route the incoming power through the first switch, then to the second switch and then to the load. Although very common and by no means a standard, it is the easiest to convert to Z-Wave control. Typical 3-way circuit: Please consult an electrician if you have trouble identifying the type of wiring circuit you wish to convert or if you do not feel confident in your ability to convert the circuit to Z-Wave control. Z-Wave unifies all your home electronics into an integrated wireless network and helps them talk to each other. Any Z-Wave enabled item can be added to the network, and making your home electronics fully compatible. WARNINGS AND CAUTIONS To be installed and/or used in accordance with appropriate electrical codes and regulations. Exercise extreme caution when using Z-Wave devices to control appliances. Operation of the Z-Wave device may be in a different please consult a qualified electrician. room than the controlled appliance, also an unintentional activation may occur if the wrong button on the remote is pressed. Z-Wave devices may automatically be powered on due to timed event programming.Depending upon the appliance, these unattended or unintentional operation could If you are unsure or uncomfortable about performing the installation, possibly result in a hazardous condition. Z-Wave enabled devices should never be used to supply power to, or control the On/Off status of medical and/or life support equipment. The ZWN-RSM1S Switch Module is a component of lighting control system, it can not be used separately but should turn an existing switch into a Z-Wave device to another until the obstacles and radio dead spots. Z-Wave Frequency.............................................................. 908.42MHz(US) Operating Temperature.............................................................32° F-104° F Size................................................................................2.02'' ×1.71'' ×0.82'' Smart Single Relay Switch Module Work with existing light switches, required neutral wire Slim size module with build in Z-Wave technology On/Off control via Z-Wave controller, manual wall switch, and/or built-in button. 3 way wiring compatible Acts as a Z-Wave repeater to extend the range With this type of circuit, ZWN-RSM1S is set behind the switch 1. Do not change the wiring of switch 2. is installed and setup with in your wall, it will retransmit the RF signal from one Please note that switch 1 must be a 4-way switch, while Load Hot Neutral Com Aux Black Red Black White Neutral Line Switch 1 (Black) (White) Neutral Switch 2 Switch 1 Yellow Please note that Switch 1 must be a 3-way switch. Wiring Diagram 2: Switch 1 Load Hot Neutral NC NO Please note that Switch 1 is a regular switch. Neutral Neutral NC: Normal Open NO: Normal Close Neutral Line (Black) (White) Neutral Line Line Switch 1 Switch 2 Location 1 Location 2 3 travel lines Aux Neutral Com Load Hot NC NO Connected switch still works even if the module is failed. When the electrical part of ZWN-RSM1S becomes invalid, the connected switch still works. Connected When the electrical part of ZWN-RSM1S becomes invalid, the connected switch does not work. With switch 2 must be a 3-way switch. Moreover, there must be 3 travel lines between switch 1 and switch 2. switch can not activate learning mode to be included or excluded with the Z-Wave network. this wiring, flick connected switch can activate learning mode to be included or excluded with the Z-Wave network. INSTALLATION INSTRUCTIONS -05--04- -06- WARRANTY INFORMATION Mar, 2014 Restoring Factory Defaults All Configuration Parameters can all be restored to their factory default settings by using your primary controller to delete/reset the device. All-ON and All-OFF Depending upon your primary controller, the ZWN-RSM1S module can be set to respond to ALL-ON and ALL-OFF commands in up to four different ways. Some controllers may not be able to change the response from its default setting. Please refer to your controller’s instructions for information on whether or not it supports the configuration function and if so, how to change this setting. The four possible responses are: - It will respond to ALL-ON and the ALL-OFF command (default). - It will not respond to ALL-ON or ALL-OFF commands. - It will respond to the ALL-OFF command but will not respond to the ALL-ON command. - It will respond to the ALL-ON command but will not respond to the ALL-OFF command. From the Remote (or repeating Z-Wave module) to destination device: Type of Construction Wood Frame with Drywall Brick, Tile or Concrete Plastic J-Boxes* Metal J-Boxes Plastic J-Boxes* Metal J-Boxes Number of Walls or Obstacles 0**100’80’100’80’ 170’56’60’48’ 249’39’36’29…
Text truncated - open the document above for the full version.
WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD. Tiancheng Industrial Zone,Yueqing ,Zhejiang Confidentiality Request Letter Page 1 of 1 Rev 2.0 07 16, 2014 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Permanent Confidentiality Request Confidentiality Request regarding application for certification of FCC ID: ZZHZWN-RSM1S We hereby request confidential treatment of information accompanying this application as outlined below: - Block Diagram - Operational Description - Schematic The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Client’s signature: Client’s name / title: Borui Zhao/ Manager Contact information / address: Tiancheng Industrial Zone,Yueqing ,Zhejiang Telephone:(86) 577-62305066 Fax:(86) 577-62305066 E-Mail:[email protected]
External Photo
FCC Certification Label FCC ID: ZZHZWN-RSM1S Label Location on EUT label size:high 1cm, Wide:2 cm EUT View/ FCC ID Label Location
Internal Photo Antenna
FCC PART 15.249 EMI MEASUREMENT AND TEST REPORT For WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD. Tiancheng Industrial Zone,Yueqing ,Zhejiang FCC ID: ZZHZWN-RSM1S July 16, 2014 This Report Concerns: Original Report Equipment Type: Smart Single Relay Switch Module Test Engineer: Lisa Chen Report No.: BSL14071011Y-9 Receive EUT Date/Test Date: July 12,2014 / July 12 - July 16, 2014 Reviewed By: Sky Zhang Prepared By: BSL Testing Co.,LTD. NO. 24, ZH Park, Nantou, Shenzhen, 518000 China Tel: 86- 755-26508703 Fax: 86- 755-26508703 Note: The test report is specially limited to the above company and this particular sample only. It may not be duplicated without prior written consent of BSL Testing Co.,LTD. This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP, NIST or any agency of the US Government. FCC ID: ZZHZWN-RSM1S BSL14071011Y-9 Page 2/23 TABLE OF CONTENTS 1. GENERAL INFORMATION ....................................................................................................3 1.1. Report information ............................................................................................................3 1.2. Measurement Uncertainty .................................................................................................3 2. PRODUCT DESCRIPTION ......................................................................................................4 2.1. EUT Description ...............................................................................................................4 2.2. Block Diagram of EUT Configuration..............................................................................5 2.3. Support Equipment List ....................................................................................................5 2.4. Test Conditions .................................................................................................................5 3. TEST RESULTS SUMMARY ...................................................................................................6 Modifications ................................................................................................................................6 4. TEST EQUIPMENT USED .......................................................................................................7 5. ANTENNA REQUIREMENT ...................................................................................................8 5.1. Standard Applicable..........................................................................................................8 5.2. Antenna Connected Construction .....................................................................................8 5.3. Result ................................................................................................................................8 6. CONDUCTED POWER LINE TEST .......................................................................................9 6.1. Test Equipment .................................................................................................................9 6.2. Test Procedure ..................................................................................................................9 6.3. Test Setup..........................................................................................................................9 6.4. Conducted Power line Emission Limits............................................................................9 6.5. Conducted Power Line Test Result.................................................................................10 7. RADIATED EMISSION TEST ...............................................................................................12 7.1. Test Equipment ...............................................................................................................12 7.2. Test Procedure ................................................................................................................12 7.3. Radiated Test Setup ........................................................................................................12 7.4. Radiated Emission Limit.................................................................................................14 7.5. Radiated Emission Test Result .......................................................................................15 8. BAND EDGE .............................................................................................................................20 8.1. Test Equipment ...............................................................................................................20 8.2. Test Procedure ................................................................................................................20 8.3. Band Edge FCC 15.249(d) Limit ....................................................................................20 8.4. Band Edge Test Result ....................................................................................................21 9. 20-DB BANDWIDTH ...............................................................................................................22 9.1. Test Equipment ...............................................................................................................22 9.2. Test Procedure ................................................................................................................22 9.3. Limit................................................................................................................................22 9.4. Test Result /Plots ............................................................................................................22 FCC ID: ZZHZWN-RSM1S BSL14071011Y-9 Page 3/23 1. GENERAL INFORMATION 1.1. Report information 1.1.1.This report is not a certificate of quality; it only applies to the sample of the specific product/equipment given at the time of its testing. The…
Text truncated - open the document above for the full version.
Conducted emissions test Radiated emissions test
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 908.42 MHz - 908.42 MHz | - |

Scene Controller
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterReceptacle
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
WIRELESS SWITCH
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
WIRELESS SWITCH
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter