  2. EcoFlow Inc./
  3. 2A2P9-EFTT5CG1

2A2P9-EFTT5CG1Power Station

EcoFlow Inc.

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Jul 20, 2026
Application Purpose
Original Equipment
Equipment Note
Power Station
Frequency Range
5180.00000000 - 5240.00000000
Company
EcoFlow Inc.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

EcoFlow Inc. Date: 6/23/2026 Federal Communications Commissions Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 RE: CFR 47 §2.911 (d)(5) Attestation FCC ID: 2A2P9-EFTT5CG1 FCC FRN: 0031193519 1. EcoFlow Inc. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. 2. EcoFlow Inc. (“the applicant”) certifies that the device does not have cybersecurity and / or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, identified on the Covered List installed on the device, nor will it be installed by the applicant anytime after certification. 3. EcoFlow Inc. (“the applicant”) certifies that the RF device is not a router “produced in a foreign country”. 4. EcoFlow Inc. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment and is not an affiliate or subsidiary of an entity identified on the Covered List. Sincerely yours, Name: Vicky Guan Job Title: Engineer Company Name: EcoFlow Inc.

Attestation Statements

EcoFlowTechnologyInc Date:7/21/2025 FederalCommunicationsCommissions AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 RE:CFR47§2.911(d)(7)FCCUSAgentLetterofAttestation GranteeCode:2A2P9 GranteeFRN:0031193519 Towhomitmayconcern: FCCUSAgent AgentCompanyName:EcoFlowTechnologyInc FCCFRN:0033593781 AgentContactName:YvonneZhou AgentUSAddress:1687114thAveSEsuite101Bellevue,WA98004UnitedStates AgentEmailAddress:[email protected] ThisletteristoconfirmthatwehaveacceptedtheresponsibilitytoactasUSAgentonbehalf ofEcoFlowInc.fortheabovereferencedFCCGranteeCode. Weareawareoftherequirementsandresponsibilitiesoftheapplicant’sagentforserviceof processasoutlinedintheFCCsection2.911(d)(7)andReportandOrderFCC22-84 paragraph63. Sincerely, Signature AuthorizedAgentContactPersonName:YvonneZhou AgentcontactJobTitle:EMCEngineer AgentCompanyname:EcoFlowTechnologyInc

Attestation Statements

EcoFlow Inc. Date: 5/14/2026 Federal Communications Commissions Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 RE: CFR 47 §2.911 (d)(7) Agent Designation Attestation Grantee Code: 2A2P9 Grantee FRN: 0031193519 EcoFlow Inc. (“the applicant”) as required by section 2.911(d)(7), designates the following agent, located in the United States, for purposes of acting as the applicant’s agent for service of process. The applicant acknowledges that they will maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility under CFR 47 §2.929(c) to inform the FCC whenever the agent information changes. U.S. Agent Information: Agent Company Name: EcoFlow Technology Inc FCC FRN: 0033593781 Agent Contact Name: Yvonne Zhou Agent US Address: 1687 114th Ave SE suite 101 Bellevue, WA 98004 United States Agent Email Address: [email protected] Sincerely yours, Signature Name: Vicky Guan Job Title: Engineer Company Name: EcoFlow Inc.

Cover Letter(s)

EcoFlow Inc. Date: 6/23/2026 UL Verification Services Inc. 47173 Benicia Street Fremont, CA 94538, USA To whom it may concern: I, the undersigned, hereby authorize UL Verification Services Inc. to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by UL Verification Services Inc. on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. In authorizing UL Verification Services Inc. as our representative, we still recognize that we are responsible to: a) fulfill the requirements for the scope of certification requested, including implementing any appropriate changes requested by UL Verification Services Telecommunications Certification Body (TCB) and / or the FCC; b) supply any and all information needed for the evaluation of the products for which certification is sought; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) not use our product certification in such a manner as to bring the TCB or FCC into disrepute and to not make any statement regarding product certification which the TCB or FCC may consider misleading or unauthorized; e) discontinue use of all advertising matter that contains any reference thereto and complies with any and all actions required by the FCC upon suspension or cancellation of certification; f) use certification only to indicate that products are certified in conformity with specified standards; g) endeavor to ensure that no certificate or report or any part thereof is used in a misleading manner, and any copies of the grants/certificates shall be reproduced in their entirety; h) comply with the requirements of the TCB and FCC, including the use of marks and label information prescribed for the scope of certification, when making reference to product certification in communication media such as documents, brochure or advertisements; i) comply with the requirements for certification, supply any information needed for evaluation of products to be certified and, where applicable, make provision for the participation of observers; j) ensure that products marketed under the scope of the requested certification continue to comply with the certification requirements; k) provide a sample of a production unit for testing within 30 days of the request should this product be selected as part of either the TCB’s or the FCC’s market surveillance requirements; l) keep a record of all complaints relating to product’s compliance with requirements of relevant standard; make records available to UL or FCC when requested; take appropriate action with respect to such complaints and any deficiencies found in the product that affect compliance with requirements for certification; document the actions taken with respect to complaints and/or deficiencies; m) inform the TCB immediately of any changes that may affect its ability to comply with the certification requirements. This authorization is valid until further written notice from the applicant. Sincerely Yours, Company Name: EcoFlow Inc. Contact Name: Vicky Guan Title of Person: Engineer Address: RM 401,Plant #1, Runheng Industrial Zone, Fuhai Street, Bao'an District, Shenzhen, 518000, China

Cover Letter(s)

EcoFlow Inc. Date: 6/23/2026 Attn: FCC Office of Engineering and Technology / UL Verification Services TCB Subject: Request for Confidentiality FCC ID: 2A2P9-EFTT5CG1 To Whom It May Concern: Pursuant to the provisions of Sections 0.457 and 0.459 of the Commission’s rules (47 CFR §§ 0.457, 0.459), we are requesting the Commission to withhold the following attachments as confidential document from public disclosure indefinitely. • Schematic Diagram • Block Diagram • Theory of Operation • Component Bom List Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant short-term confidentiality request on the following attachments until 180 days after the grant date. • External Photos • Internal Photos • Test Setup Photos • User Manual • Antenna set up photos It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Best Regards Name: Vicky Guan Job Title: Engineer Company Name: EcoFlow Inc.

ID Label/Location Info

Label Location 210 56 Power Station Model Capacity: Discharge Temperature: Charge Temperature: AC Input: AC Power IN/OUT Port Input: Max. Input Voltage d.c. MPPT rating: PV Isc Total Output: AC Output (Discharge Only): AC Output (Bypass MODE): AC Power IN/OUT Port Output (Discharge Only): USB-A Fast Charge Output: USB-C Output/sortie: Extra Battery Input Port: Extra Battery Output Port: Lithium ion AC ESS System model: Include the follow: Energy storage capacity in Wh: PCS AC input short-current rating: Battery input short-current rating: AC output fault current and duration (ac): Station électronique Modèle Capacité : Température de décharge : Température de charge : Entrée CA : Entrée du port d’alimentation CA IN/OUT : Tension d’entrée max. c.c. Caractéristiques MPPT : Courant de court-circuit PV (Isc) Puissance totale de sortie : Sortie CA (décharge uniquement) : Sortie CA (mode bypass) : Sortie du port d’alimentation CA IN/OUT (décharge uniquement) : Sortie charge rapide USB-A : Sortie USB-C : Port d’entrée de batterie supplémentaire : Port de sortie de batterie supplémentaire : Modèle du système ESS CA lithium-ion : Comprend les éléments suivants : Capacité de stockage d’énergie en Wh : Courant de court-circuit d’entrée CA PCS : Courant de court-circuit d’entrée batterie : Courant de défaut de sortie CA et durée (CA) : EF-TT-5C-G1 5017.6Wh, 204.8V⎓, 24.5Ah -10°C ~ 45°C (14°F ~ 113°F) 0°C ~ 45°C (32°F ~ 113°F) 100-120V~, 50Hz/60Hz, 15A Max. (Duration time < 3h when current exceeds 12A) 100-120V ~, 50Hz/60Hz, 33.3A Max 250V⎓ 30-250V⎓ 16A 3200W Max 20A Max 4000W Max 4000W Max,120V~, 50Hz/60Hz, 20A(×3) Max per port, 30A(×1) Max per port 4000W Max, 100-120V~, 50Hz/60Hz, 20A(×3) Max per port, 30A(×1) Max per port 4000W Max, 120~, 60Hz, 33.3A Max. 5V⎓ 3A, 9V⎓ 2A, 12V⎓ 1.5A, 18W 5V⎓ 3A, 9V⎓ 3A, 12V⎓ 3A, 15V⎓ 3A, 20V⎓ 3A, 60W 172.8-230.4V⎓, 23.1A Max. (Charge mode) 172.8-230.4V⎓, 24.6A Max. (Discharge mode) EF-TT-5C*6-G1 Part1EF-TT-5C-G1Part 2EF-TT-E5-G1 30105.6Wh MAX xxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx EcoFlow TITAN 5000 Classic IC ID27618-EFTT5CG1 HVINEF-TT-5C-G1CAN ICES(B) / NMB(B) FCC ID 2A2P9-EFTT5CG1 APP Download Efficacité Énergétique DANGER: This device is intended to be used indoors only. Do not use outdoors. DANGER: Le dispositif est destiné à être utilisé à l'intérieur seulement. Ne pas l'utiliser à l'extérieur. CAUTION: Risk of Electric Shock. Do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel. MISE EN GARDE: Risque de décharge électrique. Ne pas enlever le couvercle. Aucune des pièces à l'intérieur ne peut être réparée par l'utilisateur. L'entretien courant doit être effectué par un personnel d'entretien qualifié. "CAUTION: Risk of Electric Shock. Connect only to properly grounded outlets. MISE EN GARDE: Risque de décharge électrique. Brancher l'unité uniquement à des prises de courant correctement mises à la masse. CAUTION: Risk of Injury To Persons. Do not use this product if the power cord or the battery cables are damaged in any way. MISE EN GARDE: Risque de blessure aux personnes. Ne pas utiliser ce produit si le cordon d'alimentation ou les câbles de batterie sont endommagés de quelque façon. "Suitable for use in a repair facility. Convient pour une utilisation dans une installation de réparation WARNING: Risk of Explosion. This equipment has arcing or sparking parts which should not be exposed to flammable vapors. This equipment should be located at least 457 mm (18 inches) above the floor when used in a repair facility. AVERTISSEMENT: Risque d'explosion. Cet équipement comporte des pièces susceptibles de produire des arcs ou des étincelles qui ne doivent pas être exposées à des vapeurs inflammables. Cet équipement doit être situé à au moins 457 mm (18 po) au-dessus du sol lorsqu'il est utilisé dans un atelier de réparation. WARNING: Risk of Fire. This device contains energy higher than 1 kWh. Do not use in a sleeping room or any habitable space of a dwelling unit. AVERTISSEMENT: Risque de d'incendie. Cet appareil contient une énergie supérieure à 1 kWh. Ne pas utiliser dans une chambre à coucher ou tout espace habitable d’une unité d’habitation. CAUTION: Risk of Electric Shock. Never use portable power pack to supply power tools to cut or access live parts or live wirings. MISE EN GARDE: Risque de décharge électrique. N’utilisez jamais de bloc d’alimentation portable pour fournir des outils électriques pour couper ou accéder à des pièces sous tension ou à des câblages en direct. WARNING: Suitable for Use in Residential Non-Habitable Spaces AVERTISSEMENT: Convient à une utilisation dans un espace résidentiel non habitable WARNING: Hazardous Voltage Circuits AVERTISSEMENT: Circuits à tension élevée WARNING: To Reduce the Risk of Injury, read all instructions AVERTISSEMENT: Pour prévenir les blessures, lire toutes les instructions Manufacturer: EcoFlow Inc. RM 401, Plant #1, Runheng Industrial Zone, Fuyuany i Road, Zhancheng Community, Fuhai Street, Bao'an District, Shenzhen City,Guangdong Province, P.R.China www.ecoflow.com Made in China Note: 1. This label will be Laser carved label and can not be removed. 2. The FCC label statement will be included in the user manual which will be printed on a paper insert and sold with the device.

RF Exposure Info

The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. FCC RF EXPOSURE REPORT For Power Station MODEL NUMBER: EF-TT-5C-G1 REPORT NUMBER: 4792261286.1-2-RF-4 ISSUE DATE: June 26, 2026 FCC ID: 2A2P9-EFTT5CG1 Prepared for EcoFlow Inc. RM 401, Plant #1, Runheng Industrial Zone, Fuhai Street, Bao'an District, Shenzhen, 518000, China Prepared by UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch Room 101, Building 2, No.4, Information Road, Songshan Lake, Dongguan, Guangdong, China Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT NO.: 4792261286.1-2-RF-4 Page 2 of 7 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Revision History Rev. Issue Date Revisions Revised By V0 June 26, 2026 Initial Issue REPORT NO.: 4792261286.1-2-RF-4 Page 3 of 7 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ................................................................................. 4 2. TEST METHODOLOGY ..................................................................................................... 5 3. FACILITIES AND ACCREDITATION ................................................................................. 5 4. REQUIREMENT ................................................................................................................. 6 REPORT NO.: 4792261286.1-2-RF-4 Page 4 of 7 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 1. ATTESTATION OF TEST RESULTS Applicant Information Company Name: EcoFlow Inc. Address: RM 401, Plant #1, Runheng Industrial Zone, Fuhai Street, Bao'an District, Shenzhen, 518000, China Manufacturer Information Company Name: EcoFlow Inc. Address: RM 401, Plant #1, Runheng Industrial Zone, Fuhai Street, Bao'an District, Shenzhen, 518000, China EUT Information EUT Name: Power Station Model: EF-TT-5C-G1 Brand: ECOFLOW; EF ECOFLOW Sample Received Date: May 21, 2026 Sample Status: Normal Sample ID: 9771144 Date of Tested: June 5, 2026 to June 26, 2026 APPLICABLE STANDARDS STANDARD TEST RESULTS 447498 D04 Interim General RF Exposure Guidance v01 PASS Prepared By: Checked By: Johnson Liu Kebo Zhang Laboratory Engineer Associate Operations Leader Approved By: Stephen Guo Operations Manager REPORT NO.: 4792261286.1-2-RF-4 Page 5 of 7 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 2. TEST METHODOLOGY The tests documented in this report were performed in accordance with 47 CFR FCC Part 1 Subpart I, section 1.1307 and KDB 447498 D04 Interim General RF Exposure Guidance v01. 3. FACILITIES AND ACCREDITATION Accreditation Certificate A2LA (Certificate No.: 4102.01) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been assessed and proved to be in compliance with A2LA. FCC (FCC Designation No.: CN1187) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. Has been recognized to perform compliance testing on equipment subject to the Commission's Declaration of Conformity (DoC) and Certification rules. ISED (Company No.: 21320) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been registered and fully described in a report filed with ISED. The Company Number is 21320 and the test lab Conformity Assessment Body Identifier (CABID) is CN0046. VCCI (Registration No.: C-20202, G-20240, R-20248 and T-20202) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been assessed and proved to be in compliance with VCCI, the Membership No. is 3793. Facility Name: Chamber E, the VCCI registration No. is G-20240 and R-20248 Shielding Room F, the VCCI registration No. is C-20202 and T-20202 Note 1: All tests measurement facilities use to collect the measurement data are located at Room 101, Building 2, No.4, Information Road, Songshan Lake, Dongguan, Guangdong, China. Note 2: The test anechoic chamber in UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch had been calibrated and compared to the open field sites and the test anechoic chamber is shown to be equivalent to or worst case from the open field site. Note 3: For below 30 MHz, lab had performed measurements at test anechoic chamber and comparing to measurements obtained on an open field site. And these measurements below 30 MHz had been correlated to measurements performed on an OFS. REPORT NO.: 4792261286.1-2-RF-4 Page 6 of 7 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 4. REQUIREMENT LIMIT AND CALCULATION METHOD According to 447498 D04 Interim General RF Exposure Guidance v01, 2.1.4 MPE-Based Exemption An alternative to the SAR-based exemption is provided in § 1.1307(b)(3)(i)(C), for a much wider frequency range, from 300 kHz to 100 GHz, applicable for separ…

Text truncated - open the document above for the full version.

Test Report

The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. FCC 47 CFR PART 15 SUBPART E ISED RSS-247 Issue 4 TEST REPORT For Power Station MODEL NUMBER: EF-TT-5C-G1 REPORT NUMBER: 4792261286.1-2-RF-2 ISSUE DATE: June 26, 2026 FCC ID:2A2P9-EFTT5CG1 IC ID:27618-EFTT5CG1 Prepared for EcoFlow Inc. RM 401, Plant #1, Runheng Industrial Zone, Fuhai Street, Bao'an District, Shenzhen, 518000, China Prepared by UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch Room 101, Building 2, No.4, Information Road, Songshan Lake, Dongguan, Guangdong, China Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT NO.: 4792261286.1-2-RF-2 Page 2 of 166 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Revision History Rev. Issue Date Revisions Revised By V0 June 26, 2026 Initial Issue REPORT NO.: 4792261286.1-2-RF-2 Page 3 of 166 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Summary of Test Results Test Item Clause Limit/Requirement Result ON TIME AND DUTY CYCLE ANSI C63.10-2020, Clause 12.2 None; for reporting purposes only. Pass 6dB AND 26dB EMISSION BANDWIDTH AND 99% OCCUPIED BANDWIDTH KDB 789033 D02 v02r01 Section C.1 FCC Part 15.407 (a)/(e), RSS-247 Issue 4, Clause 7.3.5.2 RSS-Gen Clause 6.7 Pass CONDUCTED OUTPUT POWER KDB 789033 D02 v02r01 Section E.3.a (Method PM)/KDB 789033 D02 v02r01 Section E.3.a (Method PM) Section E.2.d (Method SA-2) FCC 15.407 (a) RSS-247 Clause 7.3 Pass POWER SPECTRAL DENSITY KDB 789033 D02 v02r01 Section F FCC 15.407 (a) RSS-247 Clause 7.3 Pass AC Power Line Conducted Emission ANSI C63.10-2020, Clause 6.2. FCC 15.207 RSS-GEN Clause 8.8 Pass Radiated Emissions and Band Edge Measurement KDB 789033 D02 v02r01 Section G.3, G.4, G.5, and G.6 FCC 15.407 (b) FCC 15.209 FCC 15.205 RSS-247 Clause 7.3 RSS-GEN Clause 8.9 Pass FREQUENCY STABILITY ANSI C63.10-2020,Clause 6.8 FCC Part 15.407 (g) RSS-Gen Clause 6.11 Pass Dynamic Frequency Selection (Slave) KDB 905462 D03 UNII Clients Without Radar Detection New Rules v01r02 FCC Part 15.407 (h), RSS-247 Issue 4 Clause 7.3.6 Pass Dynamic Frequency Selection (Master) KDB 905462 D02 UNII DFS Compliance Procedures New Rules v02 FCC Part 15.407 (h), RSS-247 Issue 4 Clause 7.3.6 N/A Antenna Requirement N/A FCC 47 CFR Part 15.203/ 15.407(a)(1) (2), RSS-Gen Issue 5, Clause 6.8 Pass Note: 1. N/A: In this whole report not applicable. 2. For FCC, ANSI C63.10:2020 + Cor.1:2023 is also considered for the corresponding test item which is needed. 3. For ISED, this report is also performed according to ANSI C63.10-2020 + Cor.1-2023 + C63.10a-2024 + Errata to C63.10a-2024 standards. *This test report is only published to and used by the applicant, and it is not for evidence purpose in China. *The measurement result for the sample received is <Pass> according to <FCC 47 CFR PART 15 SUBPART E, ISED RSS-247 Issue 4> when <Simple Acceptance> decision rule is applied. Decision rule for statement of conformity: The measurement uncertainty is not taken into account for statement of conformity. REPORT NO.: 4792261286.1-2-RF-2 Page 4 of 166 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. CONTENTS 1. ATTESTATION OF TEST RESULTS ..................................................................................... 6 2. TEST METHODOLOGY ......................................................................................................... 7 3. FACILITIES AND ACCREDITATION ..................................................................................... 7 4. CALIBRATION AND UNCERTAINTY ................................................................................... 8 4.1. MEASURING INSTRUMENT CALIBRATION ........................................................... 8 4.2. MEASUREMENT UNCERTAINTY ............................................................................ 8 5. EQUIPMENT UNDER TEST .................................................................................................. 9 5.1. DESCRIPTION OF EUT ........................................................................................... 9 5.2. CHANNEL LIST ........................................................................................................ 9 5.3. MAXIMUM POWER ................................................................................................ 10 5.4. TEST CHANNEL CONFIGURATION ...................................................................... 11 5.5. THE WORSE CASE POWER SETTING PARAMETER .......................................... 12 5.6. DESCRIPTION OF AVAILABLE ANTENNAS ......................................................... 14 5.7. SUPPORT UNITS FOR SYSTEM TEST ................................................................. 15 6. MEASURING EQUIPMENT AND SOFTWARE USED......................................................... 16 7. ANTENNA PORT TEST RESULTS ..................................................................................... 19 7.1. ON TIME AND DUTY CYCLE ................................................................................. 19 7.2. 6DB AND 26DB EMISSION BANDWIDTH AND 99% OCCUPIED BANDWIDTH…

Text truncated - open the document above for the full version.

Test Report

REPORT NO.: 4792261286.1-2-RF-2 Page 87 of 166 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Project Information Eut Model Titan Classic Channel 5700 Test Mode 5GWIFI Operating Mode 11A Bandwidth 20M / / Test Graph Peak Data List NO . Frequency [MHz] Reading [dBμV] Level [dBμV/m] Factor [dB/m] Limit [dBμV/m] Margin [dB] Det Pol Verdict 1 3534.84 53.11 48.97 -4.14 74.00 25.03 PK Horizontal PASS 2 5220.07 52.40 51.45 -0.95 74.00 22.55 PK Horizontal PASS 3 6982.33 44.33 52.42 8.09 74.00 21.58 PK Horizontal PASS 4 7843.61 39.73 52.30 12.57 74.00 21.70 PK Horizontal PASS 5 11401.13 68.30 63.74 -4.56 74.00 10.26 PK Horizontal PASS 6 17103.03 48.78 47.82 -0.96 74.00 26.18 PK Horizontal PASS Final Data List NO. Frequenc y [MHz] Factor [dB/m] AV Reading [dBμV/m] AV Value [dBμV/m] AV Limit [dBμV/m] AV Margin [dB] Pol Verdict 1 11401.13 -4.56 56.7 52.14 54.00 1.86 Horizont al PASS Note:(1)Level=Reading+Factor (2)Margin=Limit-Level REPORT NO.: 4792261286.1-2-RF-2 Page 88 of 166 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Project Information Eut Model Titan Classic Channel 5720 Test Mode 5GWIFI Operating Mode 11A Bandwidth 20M / / Test Graph Peak Data List NO . Frequency [MHz] Reading [dBμV] Level [dBμV/m] Factor [dB/m] Limit [dBμV/m] Margin [dB] Det Pol Verdict 1 5033.34 51.78 50.14 -1.64 74.00 23.86 PK Vertical PASS 2 6597.20 45.09 52.27 7.18 74.00 21.73 PK Vertical PASS 3 7061.69 42.65 52.33 9.68 74.00 21.67 PK Vertical PASS 4 7617.21 40.30 52.34 12.04 74.00 21.66 PK Vertical PASS 5 11437.81 61.48 56.82 -4.66 74.00 17.18 PK Vertical PASS 6 17153.05 57.37 56.45 -0.92 74.00 17.55 PK Vertical PASS Final Data List NO. Frequenc y [MHz] Factor [dB/m] AV Reading [dBμV/m] AV Value [dBμV/m] AV Limit [dBμV/m] AV Margin [dB] Pol Verdict 1 11437.81 -4.66 50.32 45.66 54.00 8.34 Vertical PASS 2 17153.05 -0.92 47.02 46.10 54.00 7.90 Vertical PASS Note:(1)Level=Reading+Factor (2)Margin=Limit-Level REPORT NO.: 4792261286.1-2-RF-2 Page 89 of 166 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Project Information Eut Model Titan Classic Channel 5720 Test Mode 5GWIFI Operating Mode 11A Bandwidth 20M / / Test Graph Peak Data List NO . Frequency [MHz] Reading [dBμV] Level [dBμV/m] Factor [dB/m] Limit [dBμV/m] Margin [dB] Det Pol Verdict 1 3672.56 51.42 47.62 -3.80 74.00 26.38 PK Horizontal PASS 2 5738.25 52.05 51.74 -0.31 74.00 22.26 PK Horizontal PASS 3 7162.05 43.19 52.71 9.52 74.00 21.29 PK Horizontal PASS 4 7752.58 41.65 52.70 11.05 74.00 21.30 PK Horizontal PASS 5 11444.48 67.19 62.57 -4.62 74.00 11.43 PK Horizontal PASS 6 17159.72 49.77 48.76 -1.01 74.00 25.24 PK Horizontal PASS Final Data List NO. Frequenc y [MHz] Factor [dB/m] AV Reading [dBμV/m] AV Value [dBμV/m] AV Limit [dBμV/m] AV Margin [dB] Pol Verdict 1 11444.48 -4.62 56.37 51.75 54.00 2.25 Horizont al PASS Note:(1)Level=Reading+Factor (2)Margin=Limit-Level REPORT NO.: 4792261286.1-2-RF-2 Page 90 of 166 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Project Information Eut Model Titan Classic Channel 5745 Test Mode 5GWIFI Operating Mode 11A Bandwidth 20M / / Test Graph Peak Data List NO . Frequency [MHz] Reading [dBμV] Level [dBμV/m] Factor [dB/m] Limit [dBμV/m] Margin [dB] Det Pol Verdict 1 4984.33 50.86 48.48 -2.38 74.00 25.52 PK Vertical PASS 2 5866.62 50.61 50.86 0.25 74.00 23.14 PK Ver…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Vicky Guan
[email protected]Fax: N.A.

Technical Contact

EcoFlow Technology IncYvonne Zhou
[email protected]

1687 114th Ave SE · Bellevue, 98004 · United States

Test Firm

UL Verification Services (Guangzhou) Co., Ltd.Stephen Guo
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115E5.18 GHz - 5.24 GHz30.00 mW
215E5.26 GHz - 5.32 GHz27.00 mW
315E5.50 GHz - 5.70 GHz30.00 mW
415E5.75 GHz - 5.83 GHz31.00 mW
Confidentiality
Long Term
Grant Notes
Power Output listed is Conducted. WLAN supports 20 MHz Bandwidth. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.

Other Applications from EcoFlow Inc.

2A2P9-PD763764-PD

WiFi/Bluetooth wireless Module

Aug 24, 2026

Equipment Class

DTS - Digital Transmission System
2A2P9-EFTT5PG1

Power Station

Jul 20, 2026

Equipment Class

DTS - Digital Transmission System
2A2P9-EFSD006