Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
EcoFlowInc. RM401,Plant#1,RunhengIndustrialZone,FuhaiStreet,Bao'anDistrict,Shenzhen518000,China Rev2026-04-24 Date:2026-08-14 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Ref:AttestationStatementsPart2.911(d)(5)(i)andPart2.911(d)(5)(ii) FCCID:2A2P9-PD763764-PD Part2.911(d)(5)(i) EcoFlowInc.certifiesthattheequipmentforwhichauthorizationissoughtisnotâcoveredâequipmentand doesnotcontainanti-virussoftwareorcybersecuritysoftwareprohibitedfromreceivinganequipment authorizationpursuantto47CFR2.903,KDB986446D01CoveredEquipmentGuidance,andFCC CoveredList(www.fcc.gov/supplychain/coveredlist). Part2.911(d)(5)(ii) EcoFlowInc.certifiesthat,asofthedateofthefilingoftheapplication,theapplicantisnotidentifiedonthe CoveredList(asaspecificallynamedentityoranyofitssubsidiariesoraffiliates)asanentityproducing âcoveredâequipment. Sincerely, Signatory [VickyGuan,Manager]
EcoFlowInc. RM401,Plant#1,RunhengIndustrialZone,FuhaiStreet,Bao'anDistrict,Shenzhen518000,China Date:2026-08-14 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 SUBJECT:FCCApplicationforFCCID:2A2P9-PD763764-PD ToWhomItMayConcern: I,theundersigned,herebystatesthisequipmenthasbeentestedandfoundtocomplywiththelimitsfora ClassBdigitaldevice,pursuanttopart15oftheFCCRules,andwillapplytheSupplier'sDeclarationof ConformityproceduretothePart15ClassBDigitalandreceiversthatoperateintherangebetween30 and960MHzofthiscompositedevice.IunderstandthefollowingFCCrequirements: 1.DevicessubjecttotheSDoCprocedurearerequiredtobetestedtoshowcompliancewiththeFCC technicalregulationsbyarecognizedaccreditedtestinglaboratory.Thetestinglaboratorymustbe accreditedbyaCommissionapprovedaccreditationbodyordesignatedunderthetermsofa government-to-governmentMutualRecognitionAgreement(MRA).Alistingofthoseaccreditedtesting laboratoriesthathavebeenrecognizedbytheCommissionispublishedontheFCCWebpage: https://apps.fcc.gov/oetcf/eas/reports/TestFirmSearch.cfm(Selectthe"accredited"optiontosearchfor FCCrecognizedaccreditedtestfirms.) 2.Pt2.1077containsthelistofinformationthatmustbeincludedintheSupplier'sDeclarationof Conformity,whichmustbesuppliedwitheachproductsold.TheSDoCcomplianceinfoshallbeincluded intheUserâsManualorasaseparatesheet.Theinfomustcontainthename,address,andphone numberoftheresponsibleparty,whichmustbelocatedwithintheUnitedStates.Accordingto 2.909(b),theresponsiblepartyiseithertheManufactureroriftheproductisimportedtheImporter. Sincerely, Signatory [VickyGuan,Manager]
EcoFlowInc. RM401,Plant#1,RunhengIndustrialZone,FuhaiStreet,Bao'anDistrict,Shenzhen518000,China Date:2026-08-14 FEDERALCOMMUNICATIONSCOMMISSION AUTHORIZATIONANDEVALUATIONDIVISION 7435OAKLANDMILLSROAD COLUMBIA,MD21046 SUBJECT:FCCApplicationforFCCID:2A2P9-PD763764-PD ConfidentialityRequest Towhomitmayconcern, PursuanttotheprovisionsoftheCommissionâsrulesTitle47Sections§0.457and§0.459,wearerequestingthe Commissiontowithholdthefollowingattachment(s)asconfidentialdocumentsfrompublicdisclosureindefinitely. â BlockDiagram â Tune-UpInformation â OperationalDescription â SecurityInformation â Schematics â SoftwareDefinedRadio(SDR)Information â PartsList Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarilyreleasedtothepublic.The publicdisclosureofthesematerialsmaybeharmfultotheapplicantandprovideunjustifiedbenefitstoits competitors. Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulationsinTitle47CFR §2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthatbusinesssensitiveinformation remainsconfidentialuntiltheactualmarketingofnewlyauthorizeddevices,werequestShortTermConfidentiality ofthefollowingattachment(s); â ExternalPhotos â TestSetupPhotos â InternalPhotos â UserManual âFor45days,pursuanttoPublicNoticeDA04-1705. or âFor180dayspursuanttoKDB726920D01. TheapplicantunderstandsthatpursuanttoSection0.457oftheRules,disclosureofthisapplicationandall accompanyingdocumentationwillnotbemadebeforethedateoftheGrantforthisapplication. Sincerely, Signatory [VickyGuan,Manager]
EcoFlowInc. RM401,Plant#1,RunhengIndustrialZone,FuhaiStreet,Bao'anDistrict,Shenzhen518000,China Date:2026-08-14 FEDERALCOMMUNICATIONSCOMMISSION AUTHORIZATIONANDEVALUATIONDIVISION 7435OAKLANDMILLSROAD COLUMBIA,MD21046 SUBJECT:FCCID:2A2P9-PD763764-PD ModelDeclarationLetter DearRegulatoryAuthority, Model(s):OS-PD763-PDaresametothemodelOS-PD764-PD,thesemodelsaresamePCBLayout, Schematics,BOM.Onlyfordifferentmodelnamefordifferentmarketrequire. Sincerely, Signatory [VickyGuan,Manager]
EcoFlowInc. RM401,Plant#1,RunhengIndustrialZone,FuhaiStreet,Bao'anDistrict,Shenzhen518000,China Date:2026-08-14 FEDERALCOMMUNICATIONSCOMMISSION AUTHORIZATIONANDEVALUATIONDIVISION 7435OAKLANDMILLSROAD COLUMBIA,MD21046 SUBJECT:FCCApplicationforFCCID:2A2P9-PD763764-PD MODULARAPPROVALLETTER RegardingtotheFCC15.212,EcoFlowInc.wouldliketorequestmodularapprovalforthesubmissionFCCID: 2A2P9-PD763764-PD.EcoFlowInc.confirmsthattheproductcomplieswithnumberedrequirementsidentified below: 1.âThemodulartransmittermusthaveitsownRFShieldingâ ThisEUThasitsownshielding,pleasereferstoexternalphotosofthereport. âThemodulartransmittermusthavebufferedmodulation/datainputsâ TheEUThasbuffereddatainputs;itisintegratedinchipESP32-S3. 2.âThemodulartransmittermusthaveitsownpowersupplyregulationâ TheEUTinterfaceprovides3.3VDC,andhasitsownVCOinside. 3.âThemodulartransmittermustcomplywiththeantennaandtransmissionsystem requirementsofSections15.203,15.204(b)and15.204(c)â TheEUTmeetstheantennarequirements.IthasaFPCAntenna.Refertothephotoofantennasare shownintheinternalphotos. 4.âThemodulartransmittermustbetestedinastand-aloneconfiguration.â TheEUTistestedinanaccesspointconfigurationviaDCpower. 5.âThemodulartransmittermustbelabeledwithitsownFCCIDnumber.â TheEUThasitsownFCCIDandthelabelisvisible. 6.âThemodulartransmittermustcomplywithanyspecificruleoroperatingrequirements applicabletothetransmitterandthemanufacturemustprovideadequateinstructionsalong withmoduletoexplainanysuchrequirement.â TheEUTcomplywithallapplicableFCCRules.Warningdetailrefertotheusermanual. 7.âThemodulartransmittermustcomplywithanyapplicableRFexposurerequirements.â TheEUTcomplywithallapplicableRFexposurerequirements.SeethisRFexposurereport. Sincerely, Signatory [VickyGuan,Manager]
EcoFlowInc. RM401,Plant#1,RunhengIndustrialZone,FuhaiStreet,Bao'anDistrict,Shenzhen518000,China Date:2026-08-14 FEDERALCOMMUNICATIONSCOMMISSION AUTHORIZATIONANDEVALUATIONDIVISION 7435OAKLANDMILLSROAD COLUMBIA,MD21046 SUBJECT:FCCApplicationforFCCID:2A2P9-PD763764-PD POWEROFATTORNEY ToWhomItMayConcern: We,theundersigned,herebyauthorizeWaltekTestingGroup(Shenzhen)Co.,Ltd.JandySoonourbehalf,to applytotheFederalCommunicationsCommissiononourequipment.AnyandallactscarriedoutbyWaltek TestingGroup(Shenzhen)Co.,Ltd.JandySoonourbehalfshallhavethesameeffectasactsofourown. ThisistoadvisethatweareinfullcompliancewiththeAnti-DrugAbuseAct.We,EcoFlowInc.arenotsubject toadenialoffederalbenefitspursuanttoSection5301oftheAnti-DrugActof1988,21USC853a,andnoparty totheapplicationissubjecttoadenialoffederalbenefitspursuanttothatsection. Sincerely, Signatory [VickyGuan,Manager]
ReferenceNo.:WTX26X07206646WPage1of8 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cn ANNEX EXHIBIT1-PRODUCTLABELING ProposedFCCIDLabelFormat FCCID:2A2P9-PD763764-PD Specifications:Thelabelshallbesecurelyaffixedtoapermanentlyattachedpartofthedevice,inalocation whereitisvisibleoreasilyaccessibletotheuser,andshallnotbereadilydetachable.Thelabelshallbe sufficientlydurabletoremainfullylegibleandintactonthedeviceinallnormalconditionsofusethroughout thedeviceâsexpectedlifetime. ProposedLabelLocationonEUT FCCIDLabel Location
WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cn RFEXPOSUREREPORT ReferenceNo.......................:WTX26X07206646W003 FCCID....................................:2A2P9-PD763764-PD Applicant...............................:EcoFlowInc. Address ................................. : RM401,Plant#1,RunhengIndustrialZone,FuhaiStreet,Bao'anDistrict, Shenzhen,518000China Manufacturer........................:ThesameasApplicant Address ................................. :ThesameasApplicant ProductName......................:WiFi/BluetoothwirelessModule ModelNo... ............................ :OS-PD764-PD Standards..............................: FCCRulePart1.1307 KDB447498D04 DateofReceiptsample ..... :2026-07-14 DateofTest...........................:2026-07-15to2026-08-01 DateofIssue ........................ :2026-08-03 ReportFormNo................... : WTX_Part1_1307W Result.....................................:Pass Remarks: Theresultsshowninthistestreportreferonlytothesample(s)tested,thistestreportcannotbe reproduced,exceptinfull,withoutpriorwrittenpermissionofthecompany.Thereportwouldbeinvalidwithout specificstampoftestinstituteandthesignaturesofapprover. PreparedBy: WaltekTestingGroup(Shenzhen)Co.,Ltd. Address:1/F.,Room101,Building1,HongweiIndustrialPark,Liuxian2ndRoad, Block70Bao'anDistrict,Shenzhen,Guangdong,China Tel.:+86-755-33663308Fax.:+86-755-33663309Email:[email protected] Testedby:Approvedby: MikeShi/ProjectEngineerJasonSu/Manager WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cn 1GeneralInformation GeneralDescriptionofEUT ProductName:WiFi/BluetoothwirelessModule TradeName:ECOFLOW;EFECOFLOW ModelNo.:OS-PD764-PD AddingModel(s):OS-PD763-PD RatedVoltage:DC3.0-3.6V BatteryCapacity:/ PowerAdapterModel:/ EquipmentType:Mobiledevice TechnicalCharacteristicsofEUT Bluetooth BluetoothVersion:V5.0(LEmode) FrequencyRange:2402-2480MHz RFOutputPower: 1Mbps:4.75dBm(Conducted) 2Mbps:1.60dBm(Conducted) DataRate:1Mbps,2Mbps Modulation:GFSK QuantityofChannels:40 ChannelSeparation:2MHz TypeofAntenna:FPCAntenna AntennaGain:4.73dBi Wi-Fi SupportStandards:802.11b,802.11g,802.11n FrequencyRange: 2412-2462MHzfor802.11b/g/n(HT20) 2422-2452MHzfor802.11n(HT40) RFOutputPower:23.47dBm(Conducted) TypeofModulation:CCK,OFDM,QPSK,BPSK,16QAM,64QAM QuantityofChannels:11for802.11b/g/n(HT20);7for802.11n(HT40) ChannelSeparation:5MHz TypeofAntenna:FPCAntenna AntennaGain:4.73dBi 2TestFacility Addressofthetestlaboratory Laboratory:WaltekTestingGroup(Shenzhen)Co.,Ltd. Address:1/F.,Room101,Building1,HongweiIndustrialPark,Liuxian2ndRoad,Block70Bao'anDistrict, Shenzhen,Guangdong,China WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cn FCCâRegistrationNo.:125990 WaltekTestingGroup(Shenzhen)Co.,Ltd.EMCLaboratoryhasbeenregisteredandfullydescribedina reportfiledwiththeFCC(FederalCommunicationsCommission).TheacceptanceletterfromtheFCCismain tainedinourfiles.TheDesignationNumberisCN5010,andTestFirmRegistrationNumberis125990. IndustryCanada(IC)RegistrationNo.:11464A The3mSemi-anechoicchamberofWaltekTestingGroup(Shenzhen)Co.,Ltd.hasbeenregisteredby CertificationandEngineeringBureauofIndustryCanadaforradioequipmenttestingwithRegistrationNo.: 11464AandtheCABidentifierisCN0057. 3RFExposureExemption Accordingto§1.1307(b)(3)andKDB447498D04InterimGeneralRFExposureGuidancev01,system operatingundertheprovisionsofthissectionshallbeoperatinginamannerthatthepublicisnotexposedto radiofrequencyenergylevelinexcesslimitformaximumpermissibleexposure. OptionA:FCCRulePart1.1307(b)(3)(i)(A):Theavailablemaximumtime-averagedpowerisnomorethan 1mW,regardlessofseparationdistance. OptionB:FCCRulePart1.1307(b)(3)(i)(B):Theavailablemaximumtime-averagedpoweroreffective radiatedpower(ERP),whicheverisgreater,islessthanorequaltothethresholdP th (mW)describedinthe followingformula.P th isgivenby: OptionC:FCCRulePart1.1307(b)(3)(i)(C):Theminimumseparationdistance(Rinmeters)fromthebodyof anearbypersonforthefrequency(finMHz)atwhichthesourceoperates,theERP(watts)isnomorethanthe calculatedvalueprescribedforthatfrequency.Rmustbeatleastλ/2Ï,whereλisthefree-spaceoperating WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cn wavelengthinmeters. SingleRFSourcesSubjecttoRoutineEnvironmentalEvaluation RFSourcefrequency(MHz)ThresholdERP(watts) 0.3-1.341,920R 2 1.34-303,450R 2 /f 2 30-3003.83R 2 300-1,5000.0128R 2 f 1,500-100,00019.2R 2 ForMultipleRFsources:FCCRulePart1.1307(b)(3)(ii): (A)Theavailablemaximumtime-averagedpowerofeachsourceisnomorethan1mWandthereisa separationdistanceoftwocentimetersbetweenanyportionofaradiatingstructureoperatingandthe nearestportionofanyotherradiatingstructureinthesamedevice,exceptifthesumofmultiplesourcesis lessthan1mWduringthetime-averagingperiod,inwhichcasetheymaybetreatedasasinglesource (separationisnotrequired). (B)InthecaseoffixedRFsourcesoperatinginthesametime-averagingperiod,orofmultiplemobileor portableRFsourceswithinadeviceoperatinginthesametimeaveragingperiod,ifthesumofthe fractionalcontributionstotheapplicablethresholdsislessthanorequalto1asindicatedinthefollowing equation. 4CalculatedResult RadioAccess Technology Prediction Frequency Output Power Antenna Gain Duty Cycle Tune-Up Time-AveragedPower ERP (MHz)(dBm)(dBi)(%)(dBm)(dBm) Bluetooth24024.754.731005.007.58 Wi-Fi241223.474.7310024.0026.58 Frequency Option Min.DistanceMax.PowerExposureLimit Ratio Result (MHz)(cm)(dBm)(mW)(mW)Pass/Fail 2402C20.007.585.73768.000.01 Pass 2412C20.0026.58454.99768.000.59Pass Note:1.Time-AveragedPower=OutputPower*DutyCycle;ERP=Time-AveragedPower+Antenna gain-2.15dB 2.OptionA,BandCrefersasclause1.2. 3.ForoptionB,Max(time-averagedpower,effectiveradiatedpower(ERP))convertstoMax.Power.For optionC,ERPconvertstoMax.Power; 4.ForoptionB,P th (mW)convertstoExposureLimit(mW);ForoptionC,ERP(W)convertstoExposure Limit(mW). 5.Ratio=Tune-UpERP(mW)/ExposureLimit(mW) WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cn ModeforSimultaneousMulti-bandTransmission: RadioAccess Technology Ratio1Ratio2 Simultaneous Ratio Limit ResultâŠ
Text truncated - open the document above for the full version.
WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cnPage 1 of 67 TESTREPORT ReferenceNo.......................:WTX26X07206646W002 FCCID....................................:2A2P9-PD763764-PD Applicant...............................:EcoFlowInc. Address.................................: RM401,Plant#1,RunhengIndustrialZone,FuhaiStreet,Bao'anDistrict, Shenzhen,518000China Manufacturer........................:ThesameasApplicant Address.................................:ThesameasApplicant ProductName......................:WiFi/BluetoothwirelessModule ModelNo...............................:OS-PD764-PD Standards..............................:FCCPart15.247 DateofReceiptsample.....:2026-07-14 DateofTest...........................:2026-07-15to2026-08-01 DateofIssue........................:2026-08-03 TestReportFormNo.......... : WTX_Part15_247W TestResult............................:Pass Remarks: Theresultsshowninthistestreportreferonlytothesample(s)tested,thistestreportcannotbe reproduced,exceptinfull,withoutpriorwrittenpermissionofthecompany.Thereportwouldbeinvalidwithout specificstampoftestinstituteandthesignaturesofapprover. PreparedBy: WaltekTestingGroup(Shenzhen)Co.,Ltd. Address:1/F.,Room101,Building1,HongweiIndustrialPark,Liuxian2ndRoad, Block70Bao'anDistrict,Shenzhen,Guangdong,China Tel.:+86-755-33663308Fax.:+86-755-33663309Email:[email protected] Testedby:Approvedby: MikeShi/ProjectEngineerJasonSu/Manager ReferenceNo.:WTX26X07206646W002 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cnPage 2 of 67 TABLEOFCONTENTS 1.GENERALINFORMATION.....................................................................................................................................4 1.1PRODUCTDESCRIPTIONFOREQUIPMENTUNDERTEST(EUT)........................................................................4 1.2TESTSTANDARDS.................................................................................................................................................5 1.3TESTMETHODOLOGY...........................................................................................................................................5 1.4TESTFACILITY.......................................................................................................................................................5 1.5EUTSETUPANDTESTMODE..............................................................................................................................6 1.6MEASUREMENTUNCERTAINTY.............................................................................................................................7 1.7TESTEQUIPMENTLISTANDDETAILS..................................................................................................................8 2.SUMMARYOFTESTRESULTS.........................................................................................................................12 3.ANTENNAREQUIREMENT.................................................................................................................................13 3.1STANDARDAPPLICABLE......................................................................................................................................13 3.2EVALUATIONINFORMATION................................................................................................................................13 4.POWERSPECTRALDENSITY...........................................................................................................................14 4.1STANDARDAPPLICABLE......................................................................................................................................14 4.2TESTSETUPBLOCKDIAGRAM...........................................................................................................................14 4.3TESTPROCEDURE..............................................................................................................................................14 4.4SUMMARYOFTESTRESULTS/PLOTS................................................................................................................14 5.DTSBANDWIDTH..................................................................................................................................................15 5.1STANDARDAPPLICABLE......................................................................................................................................15 5.2TESTSETUPBLOCKDIAGRAM...........................................................................................................................15 5.3TESTPROCEDURE..............................................................................................................................................15 5.4SUMMARYOFTESTRESULTS/PLOTS................................................................................................................15 6.RFOUTPUTPOWER............................................................................................................................................16 6.1STANDARDAPPLICABLE......................................................................................................................................16 6.2TESTSETUPBLOCKDIAGRAM...........................................................................................................................16 6.3TESTPROCEDURE..............................................................................................................................................16 6.4SUMMARYOFTESTRESULTS/PLOTS................................................................................................................16 7.FIELDSTRENGTHOFSPURIOUSEMISSIONS.............................................................................................17 7.1STANDARDAPPLICABLE......................................................................................................................................17 7.2TESTPROCEDURE........âŠ
Text truncated - open the document above for the full version.
ReferenceNo.:WTX26X07206646W002 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cnPage 60 of 67 TestGraphs LE_1M-Ant1-2402-30~1000-PASS LE_1M-Ant1-2402-1000~26500-PASS LE_1M-Ant1-2440-30~1000-PASS ReferenceNo.:WTX26X07206646W002 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cnPage 61 of 67 LE_1M-Ant1-2440-1000~26500-PASS LE_1M-Ant1-2480-30~1000-PASS LE_1M-Ant1-2480-1000~26500-PASS ReferenceNo.:WTX26X07206646W002 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cnPage 62 of 67 LE_2M-Ant1-2402-30~1000-PASS LE_2M-Ant1-2402-1000~26500-PASS LE_2M-Ant1-2440-30~1000-PASS ReferenceNo.:WTX26X07206646W002 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cnPage 63 of 67 LE_2M-Ant1-2440-1000~26500-PASS LE_2M-Ant1-2480-30~1000-PASS LE_2M-Ant1-2480-1000~26500-PASS ReferenceNo.:WTX26X07206646W002 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cnPage 64 of 67 AppendixG:DutyCycle TestResult TestModeAntenna Frequency [MHz] ONTime [ms] Period [ms] DutyCycle [%] DutyCycle Factor [dB] LE_1MAnt124022.102.5084.000.76 LE_1MAnt124402.102.5084.000.76 LE_1MAnt124802.102.5084.000.76 LE_2MAnt124021.061.8756.682.47 LE_2MAnt124401.061.8756.682.47 LE_2MAnt124801.071.8856.912.45 ReferenceNo.:WTX26X07206646W002 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cnPage 65 of 67 TestGraphs NTNV-LE_1M-Ant1-2402 NTNV-LE_1M-Ant1-2440 NTNV-LE_1M-Ant1-2480 ReferenceNo.:WTX26X07206646W002 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cnPage 66 of 67 NTNV-LE_2M-Ant1-2402 NTNV-LE_2M-Ant1-2440 NTNV-LE_2M-Ant1-2480 ReferenceNo.:WTX26X07206646W002 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cnPage 67 of 67 APPENDIXPHOTOGRAPHS PleaserefertoâANNEXâ *****ENDOFREPORT*****
WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cnPage 1 of 74 TESTREPORT ReferenceNo.......................:WTX26X07206646W001 FCCID....................................:2A2P9-PD763764-PD Applicant...............................:EcoFlowInc. Address.................................: RM401,Plant#1,RunhengIndustrialZone,FuhaiStreet,Bao'anDistrict, Shenzhen,518000China Manufacturer........................:ThesameasApplicant Address.................................:ThesameasApplicant ProductName......................:WiFi/BluetoothwirelessModule ModelNo... ............................: OS-PD764-PD Standards..............................:FCCPart15.247 DateofReceiptsample.....:2026-07-14 DateofTest ...........................: 2026-07-15to2026-08-01 DateofIssue........................:2026-08-03 TestReportFormNo. ......... : WTX_Part15_247W TestResult ............................: Pass Remarks: Theresultsshowninthistestreportreferonlytothesample(s)tested,thistestreportcannotbe reproduced,exceptinfull,withoutpriorwrittenpermissionofthecompany.Thereportwouldbeinvalidwithout specificstampoftestinstituteandthesignaturesofapprover. PreparedBy: WaltekTestingGroup(Shenzhen)Co.,Ltd. Address:1/F.,Room101,Building1,HongweiIndustrialPark,Liuxian2ndRoad, Block70Bao'anDistrict,Shenzhen,Guangdong,China Tel.:+86-755-33663308Fax.:+86-755-33663309Email:[email protected] Testedby:Approvedby: MikeShi/ProjectEngineerJasonSu/Manager ReferenceNo.:WTX26X07206646W001 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cnPage 2 of 74 TABLEOFCONTENTS 1.GENERALINFORMATION.....................................................................................................................................4 1.1PRODUCTDESCRIPTIONFOREQUIPMENTUNDERTEST(EUT)........................................................................4 1.2TESTSTANDARDS.................................................................................................................................................5 1.3TESTMETHODOLOGY...........................................................................................................................................5 1.4TESTFACILITY.......................................................................................................................................................5 1.5EUTSETUPANDTESTMODE..............................................................................................................................6 1.6MEASUREMENTUNCERTAINTY.............................................................................................................................7 1.7TESTEQUIPMENTLISTANDDETAILS..................................................................................................................8 2.SUMMARYOFTESTRESULTS.........................................................................................................................12 3.ANTENNAREQUIREMENT.................................................................................................................................13 3.1STANDARDAPPLICABLE......................................................................................................................................13 3.2EVALUATIONINFORMATION................................................................................................................................13 4.POWERSPECTRALDENSITY...........................................................................................................................14 4.1STANDARDAPPLICABLE......................................................................................................................................14 4.2TESTSETUPBLOCKDIAGRAM...........................................................................................................................14 4.3TESTPROCEDURE..............................................................................................................................................14 4.4SUMMARYOFTESTRESULTS/PLOTS................................................................................................................14 5.DTSBANDWIDTH..................................................................................................................................................15 5.1STANDARDAPPLICABLE......................................................................................................................................15 5.2TESTSETUPBLOCKDIAGRAM...........................................................................................................................15 5.3TESTPROCEDURE..............................................................................................................................................15 5.4SUMMARYOFTESTRESULTS/PLOTS................................................................................................................15 6.RFOUTPUTPOWER............................................................................................................................................16 6.1STANDARDAPPLICABLE......................................................................................................................................16 6.2TESTSETUPBLOCKDIAGRAM...........................................................................................................................16 6.3TESTPROCEDURE..............................................................................................................................................16 6.4SUMMARYOFTESTRESULTS/PLOTS................................................................................................................16 7.FIELDSTRENGTHOFSPURIOUSEMISSIONS.............................................................................................17 7.1STANDARDAPPLICABLE......................................................................................................................................17 7.2TESTPROCEDURE.âŠ
Text truncated - open the document above for the full version.
ReferenceNo.:WTX26X07206646W001 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cnPage 53 of 74 11G-Ant1-2412-PASS 11G-Ant1-2437-PASS 11G-Ant1-2462-PASS ReferenceNo.:WTX26X07206646W001 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cnPage 54 of 74 11N20SISO-Ant1-2412-PASS 11N20SISO-Ant1-2437-PASS 11N20SISO-Ant1-2462-PASS ReferenceNo.:WTX26X07206646W001 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cnPage 55 of 74 11N40SISO-Ant1-2422-PASS 11N40SISO-Ant1-2437-PASS 11N40SISO-Ant1-2452-PASS ReferenceNo.:WTX26X07206646W001 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cnPage 56 of 74 AppendixE:Bandedgemeasurements TestResult TestModeAntennaChName Frequency [MHz] RefLevel [dBm] Result [dBm] Limit[dBm]Verdict 11BAnt1Low24122.58-46.45â€-17.42PASS 11BAnt1High24629.68-38.59â€-10.32PASS 11GAnt1Low24125.18-29.73â€-14.82PASS 11GAnt1High2462-4.45-46.11â€-24.45PASS 11N20SISOAnt1Low2412-4.24-46.45â€-24.24PASS 11N20SISOAnt1High2462-3.42-47.16â€-23.42PASS 11N40SISOAnt1Low2422-5.61-45.05â€-25.61PASS 11N40SISOAnt1High2452-6.23-47.26â€-26.23PASS ReferenceNo.:WTX26X07206646W001 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cnPage 57 of 74 TestGraphs 11B-Ant1-2412-PASS 11B-Ant1-2462-PASS 11G-Ant1-2412-PASS ReferenceNo.:WTX26X07206646W001 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cnPage 58 of 74 11G-Ant1-2462-PASS 11N20SISO-Ant1-2412-PASS 11N20SISO-Ant1-2462-PASS ReferenceNo.:WTX26X07206646W001 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cnPage 59 of 74 11N40SISO-Ant1-2422-PASS 11N40SISO-Ant1-2452-PASS ReferenceNo.:WTX26X07206646W001 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cnPage 60 of 74 AppendixF:ConductedSpuriousEmission TestResult TestModeAntenna Frequency [MHz] FreqRange [Mhz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict 11BAnt1241230~10002.58-48.46â€-17.42PASS 11BAnt124121000~265002.58-33.94â€-17.42PASS 11BAnt1243730~10003.44-49.36â€-16.56PASS 11BAnt124371000~265003.44-34.11â€-16.56PASS 11BAnt1246230~10009.68-49.21â€-10.32PASS 11BAnt124621000~265009.68-34.13â€-10.32PASS 11GAnt1241230~10005.18-48.98â€-14.82PASS 11GAnt124121000~265005.18-34.45â€-14.82PASS 11GAnt1243730~1000-4.56-48.44â€-24.56PASS 11GAnt124371000~26500-4.56-34.4â€-24.56PASS 11GAnt1246230~1000-4.45-49.75â€-24.45PASS 11GAnt124621000~26500-4.45-34.35â€-24.45PASS 11N20SISOAnt1241230~1000-4.24-48.24â€-24.24PASS 11N20SISOAnt124121000~26500-4.24-34.25â€-24.24PASS 11N20SISOAnt1243730~1000-1.97-48.95â€-21.97PASS 11N20SISOAnt124371000~26500-1.97-33.84â€-21.97PASS 11N20SISOAâŠ
Text truncated - open the document above for the full version.
1687 114th Ave SE suite 101 · Bellevue, Washington, 98004 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 3.00 mW |
| 2 | 15C | 2.41 GHz - 2.46 GHz | 222.30 mW |
Power Station
Equipment Class
DTS - Digital Transmission SystemPower Station
Equipment Class
NII - Unlicensed National Information Infrastructure TXWiFi/Bluetooth wireless Module
Equipment Class
DTS - Digital Transmission SystemEcoFlow 4G Dongle SEP
Equipment Class
PCB - PCS Licensed TransmitterEcoFlow Smart Inlet Box
Equipment Class
DTS - Digital Transmission System