Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Ecovacs Home Service Robotics Co., Ltd. U.S. Agent Letter of Attestation To: Federal Communications Commission Date: January-06-2026 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Attestation Statement – Part 2.911(d)(7) filing FCC ID: 2A64B-FZD11 Ecovacs Home Service Robotics Co., Ltd. (“the applicant”) certifies that, as of the date of the filing of the application, Ecovacs Robotics, Inc. (“the agent”) is our designated U.S. agent for service of process for the above reference FCC ID. The applicant accepts to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. The applicant further acknowledges it is our responsibility to inform the FCC whenever the agent information changes. Ecovacs Robotics Co., Ltd. (“the agent”) understand it is the agent's obligation to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address. APPLICANT Company Name: Ecovacs Home Service Robotics Co., Ltd. Contact Person: Alix Liu Address: No.518 Songwei Road,Wusongjiang industry Park,Guoxiang Street, Wuzhong District,Suzhou, Jiangsu,China Tel.:0512-67072006 Email: [email protected] FCC FRN:0032456899 U.S. Agent Company Name: Ecovacs Robotics, Inc. Contact Person: Thomas Climer Address:1500 Fashion Island Blvd., Suite 201 San Mateo, CA94404 Tel.: 650.437.2872 Email: [email protected] FCC FRN:0033541814 Sincerely yours, The Applicant The Agent Company Name Ecovacs Home Service Robotics Co., Ltd. Ecovacs Robotics, Inc. Contact Person Alix Liu Thomas Climer Signature
Ecovacs Home Service Robotics Co., Ltd. Attestation Statements Not Covered Entity Applicant To: Federal Communications Commission Date: 06-01-2026 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(ii) filing FCC ID: 2A64B-FZD11 Ecovacs Home Service Robotics Co., Ltd. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely yours, Applicant Signature Printed Name: Alix Liu Title: Manager Address: No.518 Songwei Road, Wusongjiang industry Park, Guoxiang Street, Wuzhong District, Suzhou, 215100 Jiangsu, P.R. China Tel.: 0512-67072006 Email: [email protected]
Ecovacs Home Service Robotics Co., Ltd. Attestation Statements Not Covered Equipment To: Federal Communications Commission Date: 07-01-2026 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(i) filing FCC ID: 2A64B-FZD11 Ecovacs Home Service Robotics Co., Ltd. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section § 2.903 of the FCC rules. Sincerely yours, Applicant Signature Printed Name: Alix Liu Title: Manager Address: No.518 Songwei Road, Wusongjiang industry Park, Guoxiang Street, Wuzhong District, Suzhou, 215100 Jiangsu, P.R. China Tel.: 0512-67072006 Email: [email protected]
Page 1 of 1 Ecovacs Home Service Robotics Co., Ltd. Authority to Act as Agent Date: 20260106 TUV Rheinland of North America, Inc. 1279 Quarry Lane., Suite. A Pleasanton, CA 94566 To Whom It May Concern: I appoint Ms. Yanli Fan of TÜV Rheinland (Shanghai) Co., Ltd. to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the FCC or Industry Canada’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by TUV Rheinland Group, still resides with Ecovacs Home Service Robotics Co., Ltd. / No.518 Songwei Road, Wusongjiang industry Park, Guoxiang Street, Wuzhong District, Suzhou, 215100 Jiangsu, P.R. China For TCB applications, We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Date: 20260106 Agreement is valid for 12 months from the above date. By: ___ Alix Liu (Signature) (Print name) Manager 0512-67072006 (Title) (Telephone) On behalf of: Ecovacs Home Service Robotics Co., Ltd. (Company Name)
Ecovacs Home Service Robotics Co., Ltd. MS-0044715 Page 1 of 1 Revision 1 Date: __20260106_____ Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road, Columbia, MD 21046, USA Subject: Confidentiality Request for FCC ID: 2A64B-FZD11 Pursuant to FCC 47 CRF 0.457(d), the applicant requests that a part of the subject FCC/IC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term n/a External Photo Short Term Permanent Internal Photos *** Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Schematics Short Term Permanent Test Setup*** Short Term Permanent Tune-Up Procedure Short Term Permanent User’s Manual*** Short Term Permanent Part List/ Antenna Construction Ecovacs Home Service Robotics Co., Ltd.has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. (*** Exceptional case for Permanent Confidentiality for these Exhibits by PAG only) Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify TUV Rheinland in the event information regarding the product or the product is made available to the public. TUV Rheinland will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, By: __________ ________ Alix Liu ________________ (Signature/Title) (Print name) Tel.: 0512-67072006 Email: [email protected]
Size:35*30mm
Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN26C6R5 001 Auftrags-Nr.: Order no.: 326140267 Seite 1 von 29 Page 1 of 29 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2025-11-26 Auftraggeber: Client: Ecovacs Home Service Robotics Co., Ltd. No.518 Songwei Road,Wusongjiang industry Park,Guoxiang Street, Wuzhong District,Suzhou, Jiangsu,China. Prüfgegenstand: Test item: AI Companion Robot Bezeichnung / Typ-Nr.: Identification / Type no.: FZD11 Auftrags-Inhalt: Order content: SAR Test Report Prüfgrundlage: Test specification: FCC 47 CFR § 2.1093 IEEE Std 1528-2013 Published RF exposure KDB procedures Wareneingangsdatum: Date of sample receipt: 2026-01-04 Refer to the photo document Prüfmuster-Nr.: Test sample no: A004177409-001 Prüfzeitraum: Testing period: 2026-01-05 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: X Signed by: Jonathan Li genehmigt von: authorized by: X Signed by: Bell Hu Datum: Date: 2026-01-22 Ausstellungsdatum: Issue date: 2026-01-22 Stellung / Position: Sachverständige(r)/Expert Stellung / Position: Sachverständige(r)/Expert Sonstiges / Other: FCC ID: 2A64B-FZD11 Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shenzhen) Co., Ltd., 1601-1604, 1801-1804, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen, 518000 Mail: [email protected] · Web: www.tuv.com V101023GCNSR Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN26C6R5 001 Test report no.: Seite 2 von 29 Page 2 of 29 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. Informationen zur Verifizierung der Authentizität unserer Dokumente erhalten Sie auf folgender Webseite: go.tuv.com/digital-signature As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. For information on verifying the authenticity of our documents, please visit the following website: go.tuv.com/digital-signature 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2021, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Risikos durch diese Entscheidungsregel siehe ILAC G8:2019. The decision rule f…
Text truncated - open the document above for the full version.
WA-F-LA-02-181 Specification History List REV. EDITOR PAGE ITEMS OF CHANGE DATE VALID DATE ECN NO. P0 钱龙/朱敏超 ALL 2025/9/16 N/A P1 陈光芒/朱敏 超 ALL 2025/10/9 N/A UNLESS OTHER SPECIFIED TOLERANCES ON: INPAQ TECHNOLOGY CO., LTD. X=± X.X=± X.XX=± ANGLES=± HOLEDIA=± SCALE: UNIT:mm THIS DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF INPAQ TECHNOLOGY CO.,LTD.AND SHALL NOT BE REPRODUCED OR USED AS THE BASIS FOR THE MANUFACTURE OR SALE OF APPARATUS OR DEVICES WITHOUT PERMISSION DRAWN BY: 朱敏超 CHECKED BY:李志强 DESIGNED BY:陈光芒 APPROVED BY:赵付辉 TITLE:WA-F-LA-02-181 Specification DOCUMENT PAGE REV. NO. P1 PAGE 1 OF 6 WA-F-LA-02-181 Specification 1. Explanation of part number : WA _ F _ LA _ 02 _ 181 (1) (2) (3) (4) (5) (1) Product Type:Wireless Antenna (2) Combo: FPCB (3) Frequency : 2400~2500 MHz (4) Coaxial Cable Type : With RF1.13 low loss Black (5) Suffix : 181 2. Storage Condition: Temperature -40 to +85°C Humidity 20 to 85 %RH Recommended storage condition: Store in room condition as listed below: Temperature -20°C~+45ºC, Humidity 80% Max. 3. Operating Condition: Temperature -40 to +85°C Humidity 10 to 85 %RH 4. Electrical Specification: Those specifications were specially defined for 科沃斯-机器狗 WIFI model, and all characteristics were measured in the customer's machine. 4-1. Frequency Band: 4-2. Impedance 50 ohm nominal Frequency Band MHz WIFI 2400-2500 UNLESS OTHER SPECIFIED TOLERANCES ON: INPAQ TECHNOLOGY CO., LTD. X=± X.X=± X.XX=± ANGLES=± HOLEDIA=± SCALE: UNIT:mm THIS DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF INPAQ TECHNOLOGY CO.,LTD.AND SHALL NOT BE REPRODUCED OR USED AS THE BASIS FOR THE MANUFACTURE OR SALE OF APPARATUS OR DEVICES WITHOUT PERMISSION DRAWN BY: 朱敏超 CHECKED BY:李志强 DESIGNED BY:陈光芒 APPROVED BY:赵付辉 TITLE:WA-F-LA-02-181 Specification DOCUMENT PAGE REV. NO. P1 PAGE 2 OF 6 4-3. Matching circuit None 4-4. VSWR 4-4.1 Measuring Method 1.A 50Ωcoaxial cable is connected to the antenna. Then this cable is connected to a network analyzer to measure the VSWR 2.Keeping this jig away from metal at least 20cm 4-4.2 Measurement frequency points and VSWR value Frequency (Unit MHz) 2400 2450 2500 VSWR Spec. ≤3.5 VSWR ANT1 1.67 1.26 1.26 4-5. Efficiency and Gain 4-5.1 Measuring equipment Measuring instrument: Microwave chamber, Network analyzer, and standard antenna. Instructions for microwave chamber: UNLESS OTHER SPECIFIED TOLERANCES ON: INPAQ TECHNOLOGY CO., LTD. X=± X.X=± X.XX=± ANGLES=± HOLEDIA=± SCALE: UNIT:mm THIS DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF INPAQ TECHNOLOGY CO.,LTD.AND SHALL NOT BE REPRODUCED OR USED AS THE BASIS FOR THE MANUFACTURE OR SALE OF APPARATUS OR DEVICES WITHOUT PERMISSION DRAWN BY: 朱敏超 CHECKED BY:李志强 DESIGNED BY:陈光芒 APPROVED BY:赵付辉 TITLE:WA-F-LA-02-181 Specification DOCUMENT PAGE REV. NO. P1 PAGE 3 OF 6 This is a microwave chamber set up by our company in Suzhou,This microwave chamber belongs to a set of near-field measurement system. The size of the chamber is 4M * 4M * 4M. The microware chamber, shown above, using a unique multi-probe technique, The aim is to reduce the measurement time of the whole measurement system. The measuring system use multi-probe array instead of single probe to scan the measured surface of the antenna under test, a single probe has the capability of measuring orthogonal polarization amplitude and phase, it also has a wide frequency range, the corresponding multi-probe array is switched quickly by electronic switch, greatly improved the measurement efficiency. The probe model:HD-400(400MHz~6.0GHz) . Because of its capability of broadband frequency and the orthogonal polarization function, the number of probes needed to be equipped with the system is reduced; The small size of the probe reduces the coupling between the probes, make it is possible to insert probes of other frequency bands between probes, then a single system can support a wider frequency range. UNLESS OTHER SPECIFIED TOLERANCES ON: INPAQ TECHNOLOGY CO., LTD. X=± X.X=± X.XX=± ANGLES=± HOLEDIA=± SCALE: UNIT:mm THIS DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF INPAQ TECHNOLOGY CO.,LTD.AND SHALL NOT BE REPRODUCED OR USED AS THE BASIS FOR THE MANUFACTURE OR SALE OF APPARATUS OR DEVICES WITHOUT PERMISSION DRAWN BY: 朱敏超 CHECKED BY:李志强 DESIGNED BY:陈光芒 APPROVED BY:赵付辉 TITLE:WA-F-LA-02-181 Specification DOCUMENT PAGE REV. NO. P1 PAGE 4 OF 6 4-5.2 Efficiency and Gain、Radiation Pattern Antenna gain is marked (dBi) and is based on STANDARD HORN antenna. The data shows Peak Gain and Average Gain. Frequency(MHz) 2400 2450 2500 WIFI Efficiency (%) 63.1 65.46 64.42 Peak Gain (dBi) 0.92 1.09 1.01 3D Radiation Pattern Results 2D Radiation Pattern Results Physical coordinate Image
Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN25Z872 001 Auftrags-Nr.: Order no.: 326140267 Seite 1 von 90 Page 1 of 90 Kunden-Referenz-Nr.: Client reference no.: / Auftragsdatum: Order date: 2025-11-26 Auftraggeber: Client: Ecovacs Home Service Robotics Co., Ltd. No.518 Songwei Road,Wusongjiang industry Park,Guoxiang Street, Wuzhong District,Suzhou, Jiangsu,China. Prüfgegenstand: Test item: AI Companion Robot Bezeichnung / Typ-Nr.: Identification / Type no.: FZD11 Auftrags-Inhalt: Order content: Complete test Prüfgrundlage: Test specification: FCC CFR47 Part 15, Subpart C Section 15.247 ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024+Errata to C63.10a-2024 Wareneingangsdatum: Date of sample receipt: 2025-11-19 Refer to the photo document Prüfmuster-Nr.: Test sample no: A004142197-001 Prüfzeitraum: Testing period: 2025-12-12 ~ 2026-01-20 Ort der Prüfung: Place of testing: TÜV Rheinland (Shanghai) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shanghai) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: X Signed by: Yanli Fan genehmigt von: authorized by: X Signed by: Tianlin Li Datum: Date: 2026-01-22 Ausstellungsdatum: Issue date: 2026-01-22 Stellung / Position: Sachverständige(r)/Expert Stellung / Position: Sachverständige(r)/Expert Sonstiges / Other: FCC ID: 2A64B-FZD11 Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shanghai) Co., Ltd. 1st Floor of No. 10, No.153, 165, 177, 179, 189, Lane 777, West Guangzhong Road, Jingan District, Shanghai Mail: [email protected] · Web: www.tuv.com V101023GCNSR Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN25Z872 001 Test report no.: Seite 2 von 90 Page 2 of 90 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. Informationen zur Verifizierung der Authentizität unserer Dokumente erhalten Sie auf folgender Webseite: go.tuv.com/digital-signature As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. For information on verifying the authenticity of our documents, please visit the following website: go.tuv.com/digital-signature 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2023, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Risikos durch diese Entscheidungsregel siehe ILAC G8:2019. The decision rule for statements o…
Text truncated - open the document above for the full version.
Produkte Products Prüfbericht - Nr.: Test Report No. CN25Z872 001 Seite 71 von 90 Page 71 of 90 Limit and Margin QP Frequency (MHz) QuasiPeak (dBμV/m) Pol Corr. (dB/m) Margin - QPK (dB) Limit - QPK (dBμV/m) 273.470000 26.5 H 19.9 19.5 46.0 315.422500 27.7 H 20.4 18.3 46.0 408.057500 30.3 H 23.5 15.7 46.0 624.003750 38.6 H 26.9 7.4 46.0 672.018750 37.9 H 26.6 8.1 46.0 720.033750 34.9 H 28.2 11.2 46.0 31.212500 28.4 V 24.8 11.6 40.0 163.132500 23.2 V 16.8 20.3 43.5 419.091250 32.6 V 24.0 13.4 46.0 456.072500 28.8 V 24.2 17.2 46.0 480.080000 34.7 V 24.7 11.3 46.0 575.988750 38.4 V 26.4 7.6 46.0 PK Frequency (MHz) MaxPeak (dBμV/m) Pol Corr. (dB/m) Margin - PK+ (dB) Limit - PK+ (dBμV/m) 1462.818182 39.5 H -18.6 34.5 74.0 4924.000000 47.9 H -11.1 26.1 74.0 6336.181818 48.0 H -8.5 26.0 74.0 7996.875000 46.0 H -3.3 28.0 74.0 10894.687500 48.0 H -1.5 26.0 74.0 17989.000000 58.1 H 11.9 15.9 74.0 1763.363636 44.5 V -18.8 29.5 74.0 3431.363636 44.6 V -14.8 29.4 74.0 4924.000000 52.9 V -11.1 21.2 74.0 8013.031250 46.8 V -3.3 27.2 74.0 11484.562500 48.7 V -1.6 25.3 74.0 17989.000000 58.3 V 11.9 15.7 74.0 AV Frequency (MHz) Average (dBμV/m) Pol Corr. (dB/m) Margin - AVG (dB) Limit - AVG (dBμV/m) 1462.818182 27.4 H -18.6 26.6 54.0 4924.000000 46.1 H -11.1 7.9 54.0 6336.181818 42.7 H -8.5 11.3 54.0 7996.875000 34.6 H -3.3 19.4 54.0 10894.687500 34.5 H -1.5 19.5 54.0 17989.000000 48.7 H 11.9 5.3 54.0 1763.363636 35.3 V -18.8 18.7 54.0 3431.363636 34.4 V -14.8 19.6 54.0 4924.000000 50.8 V -11.1 3.2 54.0 8013.031250 34.7 V -3.3 19.3 54.0 11484.562500 34.7 V -1.6 19.3 54.0 17989.000000 48.7 V 11.9 5.3 54.0 Produkte Products Prüfbericht - Nr.: Test Report No. CN25Z872 001 Seite 72 von 90 Page 72 of 90 Figure 25: Radiated Spurious Emission, 802.11g, 2412MHz 30MHz to 1GHz H 30MHz to 1GHz V 1GHz to 7GHz H 1GHz to 7GHz V 7GHz to 18GHz H 7GHz to 18GHz V 0 10 20 30 40 50 60 70 80 30M 50 60 80 100M 200 300 400 500 800 1G Level in dBμV/m Frequency in Hz _Radiated emission (30M-1GHz) 1 Range_FCC 0 10 20 30 40 50 60 70 80 30M 50 60 80 100M 200 300 400 500 800 1G Level in dBμV/m Frequency in Hz _Radiated emission (30M-1GHz) 1 Range_FCC 0 10 20 30 40 50 60 70 80 1G 2G 3G 4G 5G 6 7G Level in dBμV/m Frequency in Hz Radiated emission (1-7GHz) FSV 40 0 10 20 30 40 50 60 70 80 1G2G3G4G5G67G Level in dBμV/m Frequency in Hz Radiated emission (1-7GHz) FSV 40 0 10 20 30 40 50 60 70 80 7G 9 10G 18G Level in dBμV/m Frequency in Hz Radiated emission (7-18GHz) FSV 40 0 10 20 30 40 50 60 70 80 7G 910G18G Level in dBμV/m Frequency in Hz Radiated emission (7-18GHz) FSV 40 Produkte Products Prüfbericht - Nr.: Test Report No. CN25Z872 001 Seite 73 von 90 Page 73 of 90 Limit and Margin QP Frequency (MHz) QuasiPeak (dBμV/m) Pol Corr. (dB/m) Margin - QPK (dB) Limit - QPK (dBμV/m) 274.318750 28.5 H 19.9 17.6 46.0 321.727500 29.1 H 21.2 16.9 46.0 408.057500 31.2 H 23.5 14.8 46.0 575.988750 37.6 H 26.4 8.4 46.0 624.125000 34.7 H 26.9 11.3 46.0 672.018750 38.7 H 26.6 7.4 46.0 30.242500 28.9 V 25.3 11.1 40.0 162.405000 23.1 V 16.8 20.4 43.5 456.072500 28.9 V 24.2 17.1 46.0 555.982500 30.5 V 26.5 15.5 46.0 575.988750 38.4 V 26.4 7.6 46.0 599.996250 36.1 V 26.4 9.9 46.0 PK Frequency (MHz) MaxPeak (dBμV/m) Pol Corr. (dB/m) Margin - PK+ (dB) Limit - PK+ (dBμV/m) 2577.727273 44.1 H -15.8 29.9 74.0 3599.909091 40.5 H -14.1 33.5 74.0 4824.454546 54.4 H -11.2 19.6 74.0 7171.875000 45.9 H -5.5 28.1 74.0 11057.281250 49.9 H -2.0 24.1 74.0 17997.250000 59.3 H 12.1 14.7 74.0 2574.000000 49.2 V -15.8 24.8 74.0 4824.181818 54.2 V -11.2 19.8 74.0 6335.909091 46.0 V -8.5 28.0 74.0 7115.500000 46.7 V -5.0 27.3 74.0 9647.562500 47.7 V -4.2 26.3 74.0 17982.125000 58.5 V 11.8 15.5 74.0 AV Frequency (MHz) Average (dBμV/m) Pol Corr. (dB/m) Margin - AVG (dB) Limit - AVG (dBμV/m) 2577.727273 35.6 H -15.8 18.4 54.0 3599.909091 33.6 H -14.1 20.4 54.0 4824.454546 44.7 H -11.2 9.3 54.0 7171.875000 34.7 H -5.5 19.3 54.0 11057.281250 38.0 H -2.0 16.0 54.0 17997.250000 48.0 H 12.1 6.0 54.0 2574.000000 39.3 V -15.8 14.7 54.0 4824.181818 43.3 V -11.2 10.7 54.0 6335.909091 38.9 V -8.5 15.1 54.0 7115.500000 34.9 V -5.0 19.1 54.0 9647.562500 42.3 V -4.2 11.8 54.0 17982.125000 48.7 V 11.8 5.3 54.0 Produkte Products Prüfbericht - Nr.: Test Report No. CN25Z872 001 Seite 74 von 90 Page 74 of 90 Figure 26: Radiated Spurious Emission, 802.11g, 2437MHz 30MHz to 1GHz H 30MHz to 1GHz V 1GHz to 7GHz H 1GHz to 7GHz V 7GHz to 18GHz H 7GHz to 18GHz V 0 10 20 30 40 50 60 70 80 30M 50 60 80 100M 200 300 400 500 800 1G Level in dBμV/m Frequency in Hz _Radiated emission (30M-1GHz) 1 Range_FCC 0 10 20 30 40 50 60 70 80 30M 50 60 80 100M 200 300 400 500 800 1G Level in dBμV/m Frequency in Hz _Radiated emission (30M-1GHz) 1 Range_FCC 0 10 20 30 40 50 60 70 80 1G 2G 3G 4G 5G 6 7G Level in dBμV/m Frequency in Hz Radiated emission (1-7GHz) FSV 40 0 10 20 30 40 50 60 70 80 1G 2G 3G 4G 5G 6 7G Level in dBμV/m Frequency in Hz Radiated emission (1-7GHz) FSV 40 0 10 20 30 40 50 60 70 80 7G 9 10G 18G Level in dBμV/m Frequency in Hz Radiated emission (7-18GHz) FSV 40 0 10 20 30 40 50 60 70 80 7G 9 10G 18G Level in dBμV/m Frequency in Hz Radiated emission (7-18GHz) FSV 40 Produkte Products Prüfbericht - Nr.: Test Report No. CN25Z872 001 Seite 75 von 90 Page 75 of 90 Limit and Margin QP Frequency (MHz) QuasiPeak (dBμV/m) Pol Corr. (dB/m) Margin - QPK (dB) Limit - QPK (dBμV/m) 281.593750 25.7 H 19.6 20.3 46.0 407.936250 30.0 H 23.5 16.0 46.0 575.988750 37.6 H 26.4 8.4 46.0 624.125000 34.7 H 26.9 11.3 46.0 648.011250 36.4 H 27.0 9.6 46.0 672.018750 38.7 H 26.6 7.3 46.0 30.970000 28.5 V 24.9 11.5 40.0 165.800000 22.7 V 16.6 20.8 43.5 354.586250 25.4 V 21.9 20.6 46.0 456.072500 32.9 V 24.2 13.2 46.0 480.080000 32.8 V 24.7 13.2 46.0 575.988750 38.4 V 26.4 7.6 46.0 PK Frequency (MHz) MaxPeak (dBμV/m) Pol Corr. (dB/m) Margin - PK+ (dB) Limit - PK+ (dBμV/m) 1798.272727 42.4 H -18.8 31.6 74.0 4866.454546 53.1 H -11…
Text truncated - open the document above for the full version.
1500 Fashion Island Blvd., Suite 201 · San Mateo, California, 94404 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.41 GHz | 60.70 mW |
| 2 | 15C | 2.42 GHz - 2.45 GHz | 60.70 mW |

Floor Cleaning Robot
Equipment Class
DTS - Digital Transmission System
Floor Cleaning Robot
Equipment Class
DTS - Digital Transmission System
Floor Cleaning Robot
Equipment Class
DTS - Digital Transmission System
Window Cleaning Robot
Equipment Class
DTS - Digital Transmission System
Window Cleaning Robot
Equipment Class
DTS - Digital Transmission System