FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SHENZHEN XGRIDS-INNOVATION CO., LTD/
  3. 2A9PI-LIXELHOLO1

2A9PI-LIXELHOLO1Mobile Lidar Scanner

SHENZHEN XGRIDS-INNOVATION CO., LTD
Mobile Lidar Scanner - FCC ID 2A9PI-LIXELHOLO1 - SHENZHEN XGRIDS-INNOVATION CO., LTD
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 19, 2026
Application Purpose
Original Equipment
Equipment Note
Mobile Lidar Scanner
Frequency Range
2412.00000000 - 2462.00000000
Company
SHENZHEN XGRIDS-INNOVATION CO., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Lixel Holo 1 User Manual 一:Product Overview 1:Front camera 2:Air outlet 3:LiDAR 4:Battery indicator light 5:Battery eject button 6:Cold shoe mount 7:Fisheye camera 8:USB port (cannot charge the battery) 9:Control point base 10:Sound outlet 11:Power button 12:Non-slip heat insulation pad 13:1/4-inch port 14:Battery base bayonet 1. When the device is powered on, it enters the normal power consumption mode. If no scanning operation is initiated within 5 minutes, the device switches to low power consumption mode, where its power consumption is approximately one-third of that in normal mode. In low power mode, the LiDAR does not operate, but data can still be copied. After data collection is completed, the device will also enter low power mode if it remains idle for 5 minutes after scanning is stopped. 2. The device will emit an audible alert when powered on, powered off, when the battery level is below 20%, and when below 10%. During recording, if the battery level drops below 10%, the device will forcibly stop recording and save the data. When the battery level is below 5%, the device will automatically power off to protect itself. 3. If the battery level is below 10%, the device will not power on when the battery is installed. 4. If the battery level displayed on the APP is abnormal, it may be that the battery is not properly inserted. Please press the buckles on both sides of the battery into place and check whether the battery level is normal again. 二:Basic Functions of the Equipment 2.1、Battery Installation and Charging 1、Battery Installation 1、Follow the instructions in the image above, insert the battery slowly with one side facing upward. 2、Push the battery into the bottom of the device along the guide slots until it is fully inserted. 3、To remove the battery, press the button firmly in the direction indicated by the arrow in the figure below. The battery will pop out; catch it by hand to prevent it from falling. 2、Battery Charging and Indicator Lights Use the standard charger and charging cable to connect to the Type-C port on the battery manager. Insert the battery into the battery manager to start charging. The charging time from 0 to 100% battery level is approximately 90 minutes. The recommended ambient temperature for charging is 5°C to 30°C.3、Description of the battery indicator light during charging: 4、Indicator light description of the battery in non-charging status: 5、Battery Maintenance Instructions 1. After daily use of the device, the battery should be fully charged in a timely manner. 2. For fully charged batteries that are not used for a long time, recharge them once every 3 months. 3. For batteries with extremely low power or completely depleted power, they must be charged within 3 days. Damage to the battery caused by failure to follow the above requirements is irreparable and not covered by the warranty. Please perform timely maintenance to ensure the battery remains in good condition! 2.2、PDA Installation As shown in the figure below, insert the phone holder downward into the cold shoe slot on the back cover of the device in the direction indicated by the arrow. Attach the phone holder to the cold shoe mount of the device. The back of the PDA is equipped with a magnetic ring, which can mate with the magnetic ring on the phone holder to secure the PDA in place. 2.3:Description of Buttons and Indicator Lights 1、Device Buttons As indicated by the arrow in the figure below, this is the only button on the device, which controls functions such as power on, power off, scanning, and USB disk mode. Functions Button Operations Device Status Description Power On Long press the battery button for 2 seconds Long press the battery button for 2 seconds. When the device indicator changes from slow flashing blue to steady green, the device enters standby mode. Power Off Long press the battery button for 2 seconds in standby mode When the device is in standby mode, long press the battery button for 2 seconds. The indicator turns off, indicating that the shutdown is complete. Start Scan Double click the device button When the device is in standby mode, double-click the device button. The device indicator changes from steady green to fast flashing green for about 20 seconds, then switches to slow flashing green, indicating that scanning has started successfully and the device has entered scan mode. Stop Scan Double click the device button When the device is in scan mode, double-click the device button. The indicator changes from slow flashing green to steady green, indicating that scanning has stopped successfully and the device returns to standby mode. Switch to USB Disk Mode Single click the device button + device indicator lights up white + single click the device button When the device is in standby mode, single-click the device button, and the indicator will turn white for approximately 3 seconds. Single-click the button again while the white light is on to switch to USB disk mode. If no further operation is performed within 3 seconds, the device will remain in standby mode. When the device is in USB disk mode, single-click the device button, and the indicator will turn white for approximately 3 seconds. Single-click the button again while the white light is on to switch to standby mode. If no further operation is performed within 3 seconds, the device will remain in USB disk mode. Notes 1. Before starting scanning, place the device on a flat and stable surface. After starting scanning, do not move the device for scanning until the green light flashes slowly. 2. The device startup time is approximately 25 seconds, and the scanning startup time is about 20 seconds. 3. During the scanning stop process, if the indicator light flashes green rapidly, it means the device is saving the scanned files. Powering off at this time may result in file loss or incomplete saving. 4. After scanning stops, the green fast flashing may last for a relatively long time, depending on the size of the sc…

Text truncated - open the document above for the full version.

Attestation Statements

1/1 USAgentforServiceofProcessLETTEROFATTESTATION TO: OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USAgentforServiceofProcess: CompanyName:HerlandInternationalTradingInc FRN:0036324101 ContactName:JianfengGao Address:1370ValleyVistaDrSte200DiamondBarCalifornia91765-3921 TelephoneNo:001-909-772-1888 Email:[email protected] Applicant: Companyname:SHENZHENXGRIDS-INNOVATIONCO.,LTD ProductDescription:MobileLidarScanner Granteecode:2A9PI FCCID:2A9PI-LIXELHOLO1 FRN:0033173469 ContactName:ZhixinChen Address:2403&2404,24Floor,Building1B,ShenzhenInternationalInnovationValley, Liuxiandong,NanshanDistrict,Shenzhen,Guangdong,China TelephoneNo:+86-18825284823 Email:[email protected] [SHENZHENXGRIDS-INNOVATIONCO.,LTD]certifiesthat,asofthedateof thisfilingoftheapplicationwiththeTCB,[HerlandInternationalTradingInc]is ourdesignatedUSagentforserviceofprocessfortheabovereferencedFCCID. [SHENZHENXGRIDS-INNOVATIONCO.,LTD]acceptstomaintainanagentfor nolessthanoneyearafterthegranteehasterminatedallmarketingand importationortheconclusionofanycommissionrelatedproceedinginvolving equipment.[HerlandInternationalTradingInc]accepts,asofthedateofthe filingoftheapplication,theobligationofthedesignatedUSagentforserviceof processfortheabovereferenceFCCID. TheUSAgentforServiceofProcessisawareofandagreestocomplywiththerequirements outlinedintheFCCEquipmentAuthorizationProgram,ReportandOrderFCC22-84,andclause §2.911. TheApplicantisawareofandagreestocomplywiththerequirementsoutlinedintheFCC EquipmentAuthorizationProgram,ReportandOrderFCC22-84,andclause§2.911. Date:2026/05/12 Applicant’sName:ZhixinChenUSAgent’sName:JianfengGao Title:ProjectManagerTitle:Manager SignatureSignature

Attestation Statements

AttestationStatement. OldCode:C526609124NewCode:00015544Ed.3 Changereason:FRNisaddedtotheApplicantinformationsection. 1/1 SHENZHENXGRIDS-INNOVATIONCO.,LTD TO: OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 TheCommissionadoptedrulesthatprohibitequipmentauthorizationfor“covered” telecommunicationsequipmentandvideosurveillanceequipmentproducedbyentitiesidentified ontheCommission’sCoveredList 1 ,whichisperiodicallyupdated.SeetheCoveredListformore details.ThisAttestationStatementistoconfirmthatwefollowtheSection2.911(d)(5)(i)-(ii) Applicant Companyname:SHENZHENXGRIDS-INNOVATIONCO.,LTD Granteecode:2A9PI FCCID:2A9PI-LIXELHOLO1 FRN:0033173469 ContactName:ZhixinChen Address:2403&2404,24Floor,Building1B,ShenzhenInternationalInnovationValley, Liuxiandong,NanshanDistrict,Shenzhen,Guangdong,China TelephoneNo:+86-18825284823 FaxNo:+86-18825284823 Email:[email protected] i.[SHENZHENXGRIDS-INNOVATIONCO.,LTD](“theapplicant”)certifies thattheequipmentforwhichauthorizationissoughtisnot“covered” equipmentprohibitedfromreceivinganequipmentauthorizationpursuantto section2.903oftheFCCrules.Theapplicantmustsignthiscertification. ii.[SHENZHENXGRIDS-INNOVATIONCO.,LTD](“theapplicant”)certifies that,asofthedateofthefilingoftheapplication,theapplicant[isnot](asa specificallynamedentityoranyofitssubsidiariesoraffiliates)identifiedon theCoveredListasanentityproducing“covered”equipment.Theapplicant mustsignthiscertification. [SHENZHENXGRIDS-INNOVATIONCO.,LTD](“theapplicant”)certifiesthat,asof thedateofthefilingoftheapplication,theapplicant[isnot]identifiedonthe CoveredListasanentityproducing“covered”equipment. Date:2026/05/12 Applicant’sName:ZhixinChen Title:ProjectManager Signature: 1 TheCommission’sCoveredListispublishedbythePublicSafetyandHomelandSecurityBureauandpostedonthe Commission’swebsite.ThisCoveredList,whichisperiodicallyupdated,identifiesparticularequipment,producedby particularentities,thatconstitutes“covered”equipment.https://www.fcc.gov/supplychain/coveredlist AttestationStatement. OldCode:C526609124NewCode:00015544Ed.3 Changereason:FRNisaddedtotheApplicantinformationsection. 1/1

Attestation Statements

SHENZHENXGRIDS-INNOVATIONCO.,LTD Code00018768Ed.1 Item1.Thedeviceisabletoinstallsoftware/programinstallation? ☐ Yes,gotoItem2. ☒ No.Inthiscase,therestoftheitemsdonotapply.ThedevicecannotsupportinstallationofKaspersky cybersecurityoranti-virussoftware. Item2.TechnicalRequirementsforKasperskyCybersecuritySoftware: #GeneralRequirements(ForallDevices)Yes/NoorN/AComments 1Internetconnectionforactivationandupdates(ForallOperating Systems) N/A DeviceMobileLidarScanner CompanynameSHENZHENXGRIDS-INNOVATIONCO.,LTD Granteecode2A9PI FCCID2A9PI-LIXELHOLO1 FRN0033173469 ContactnameZhixinChen Address2403&2404,24Floor,Building1B,Shenzhen InternationalInnovationValley,Liuxiandong, NanshanDistrict,Shenzhen,Guangdong,China Telephonenumber+86-18825284823 [email protected] Chipset/moduleinformationRTL8852BE OperatingSystem(ifapplicable)N/A StorageCapacity(harddriveorother permanentmemorystorage,ifapplicable) N/A 2 #GeneralRequirements(ForWindowsDevices)Yes/NoorN/AComments 1Storage:1500MBfreespaceontheharddriveN/A 2OperatingSystem: MicrosoftWindows8,8.1,10&11Home/Pro/Enterprise Microsoft Windows7Starter/HomeBasic&Premium/Professional/ UltimateSP1orhigher N/A 3Processor:1GHzorhigher(x86orx64)N/A 4Memory(RAM)1GB(32-bit)or2GB(64-bit)N/A 5ScreenResolution:Minimumresolutionof1024x768N/A #GeneralRequirements(FormacOSdevices)Yes/NoorN/AComments 1OperatingSystemmacOS®13–14N/A 2Memory(RAM)4GBN/A 3Storage:3455MBfreespaceontheharddriveN/A #GeneralRequirements(ForAndroidDevices)Yes/NoorN/AComments 1Storage:150MBfreespaceN/A 2OperatingSystem:Android™10–14N/A 3ScreenResolution:Minimumresolutionof320x480N/A #GeneralRequirements(foriOSdevices)Yes/NoorN/AComments 1Storage:150MBfreespaceN/A 2OperatingSystem:iOS®17N/A #GeneralRequirements(ForLinuxsystem)Yes/NoorN/AComments 3 1Harddrive:1GBoffreespaceN/A 2CPU:IntelPentium1GHzorhigherN/A 3RAM:1GBN/A 4Minimumsoftwarerequirements: AlmaLinuxOS8orlater; AlterOS7.5orlater; AstraLinuxCommonEdition2.12orlater; CentOS6.7orlater; DebianGNU/Linux10.0orlater; EulerOS2.0orlater; OracleLinux7.3orlater; RedHatEnterpriseLinux6.7orlater; RockyLinux8.5orlater; SUSELinuxEnterpriseServer12.5orlater; Ubuntu12.04orlater; UncomOSHome/Business/Education/Enterprise2.2orlater; ALTLinuxWorkstaton/WorkstationK/Server/Education8or later; ROSALinuxWorkstation/Server12orlater; REDOS7.3andlater; N/A Afterreviewedthetechnicalrequirements,isthedevicecapableofsupportingtheinstallationof Kasperskysoftware? ☐ Yes,gotoItem3. ☒No.Inthiscase,therestoftheitemsdonotapply.ThedevicecannotsupportinstallationofKaspersky software Item3.ConnectivityCapabilities: 4 #PhysicalInterfacePurposeJustification 1 1 #WirelessInterfacePurposeJustification 1 1 Afterthereviewofthisitems,thedevice: ☒Cannotsupportinstallationofanycybersecurityoranti-virussoftwareonthecoveredlist. ☐ Potentiallycanoperatewithanycybersecurityoranti-virussoftwareonthecoveredlist–additionalthird- partyproofisprovidedtodemonstratecompliancewithrequirementsasof2.911(d)5(i),(ii)–“Proofof CompliancewithCoveredListSoftwareRequirements”ofthisdocumentapplies ignature:Name:ZhixinChen Date:2026-05-12 1 Thejustificationfieldisusedtojustifywhythesoftwarecannotbereceivedthroughthatinterface.Checktheannexformore indications.

Attestation Statements

TCBCALLpágina1 FileFCCID:2A9PI-LIXELHOLO1 PleaseuploadanexhibitthatexplainshowdoestheTCBverifythenewagentinformation: 1-IstheaddressoftheagentavalidphysicalUSmailingaddress(notaUSpostofficebox,notavirtualmailbox,notP.O.Boxes,notavacantlot,notapublicbuilding, etc.) ○Wehavecheckediftheaddressexistsinarealandpotentialbuilding(Googlemaps)+officialUSregister,afterthisverificationandtheevidencebelowwecan guaranteethefollowing: notaUSpostofficebox notavirtualmailbox notP.O.Boxes notavacantlot notapublicbuilding(note) ►WecheckedtheFCCFRNSearchbasedontheinformationprovidedbythegrantee. Ontheofficialregisterfrom:Search|CaliforniaSecretaryofState TCBCALLpágina2 TCBCALLpágina3 TCBCALLpágina4 TCBCALLpágina5 TCBCALLpágina6 TCBCALLpágina7 TCBCALLpágina8 TCBCALLpágina9 ►CONCLUSIONbyTCB:TheASOPdefinedandprovidedbygranteeisVALIDandconfirmed.Thereforetheexhibit"C5266091_X23_Ed1_US_Agent_Letter" includedinthefileisok. 2-IstheagentphysicallylocatedatthatvalidUSaddresssuchthattheagentcanbelegallyservedatthataddress? Yes,checkabove 3-Hasthelistedagentclearlyagreedinwritingtoserveastheagentforthegranteeatthataddress? Yes,itisincludedintheexhibit"C5266091_X23_Ed1_US_Agent_Letter" >

Cover Letter(s)

C5266091_X10_Ed.2 1/1 SHENZHENXGRIDS-INNOVATIONCO.,LTD OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:2026.05.12 Subject:RequestforConfidentiality FCCID:2A9PI-LIXELHOLO1 ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality NOTE2 IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo ☐ BlockDiagram ☒☐ Schematics ☒☐ TestReportNoNo TestSetupPhotosNo ☐ User’sManual ☐ NOTE 1 ☐ InternalPhotos ☐ NOTE 1 ☐ PartsList/TuneUp ☒☐ RFExposureInfoNoNo OperationalDescription ☒☐ CoverLetter(s)NoNo SDRSoftware/SecurityInfo ☒ No NOTE1:Long-TermConfidentialitymaybepermittedunderspecialconditions(SeeII.LONG-TERMCONFIDENTIALITY,Section3of KDB726920,uselastinforce) NOTE2:Short-TermConfidentialitycanberequestedforamaximumof180daysfromthedateofthegrant. Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Incaseofshort-termConfidentiality,theapplicantrequeststheexhibitsselected abovearewithheldfrompublicviewforaperiodof______daysfromthedateofthe GrantofEquipmentAuthorizationandpriortomarketing. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. Sincerely, C5266091_X10_Ed.2 1/1 Signature: Name:ZhixinChen Title:ProjectManager 2026.05.12

Cover Letter(s)

C5266091_X8_Ed.1 1/1 LetterofAuthorization SHENZHENXGRIDS-INNOVATIONCO.,LTD Company:SHENZHENXGRIDS-INNOVATIONCO.,LTD Address:2403&2404,24Floor,Building1B,ShenzhenInternational InnovationValley,Liuxiandong,NanshanDistrict,Shenzhen, Guangdong,China ProductName:MobileLidarScanner ModelNumber:LixelHolo1 FCCIdentifier:2A9PI-LIXELHOLO1 WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:ZhixinChenDate:2026.05.12 Title:ProjectManager Signatureofapplicant:

External Photos

Shenzhen DL Testing Technology Co., Ltd. EUT PHOTO(External Photos) Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. ※※※※※ END OF REPORT ※※※※※

ID Label/Location Info

Size: 32*14mm M/N: Lixel Holo 1 FCC ID: 2A9PI-LIXELHOLO1 Label location

Internal Photos

Shenzhen DL Testing Technology Co., Ltd. EUT PHOTO(Internal Photos) Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. GPS ANT(RX) Shenzhen DL Testing Technology Co., Ltd. BT/WIFI ANT 1 WIFI ANT 2 Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. ※※※※※ END OF REPORT ※※※※※

RF Exposure Info

FCC ID: 2A9PI-LIXELHOLO1 RF Exposure Evaluation Limits KDB 447498 D01 General RF Exposure Guidance v06 FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposures 0.3–3.0 614 1.63 *(100) 6 3.0–30 1842/f 4.89/f *(900/f 2 ) 6 30–300 61.4 0.163 1.0 6 300–1500 f/300 6 1500–100,000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f 2 ) 30 30–300 27.5 0.073 0.2 30 300–1500 f/1500 30 1500–100,000 1.0 30 f = frequency in MHz Friis transmission formula: Pd = (Pout*G)/(4*pi*r 2 ) Where Pd = power density in mW/cm 2 , Pout = output power to antenna in mW; G = gain of antenna in linear scale, Pi = 3.1416; R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm 2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. EIRP=EMeas+20log(dMeas)-104.7 EIRP is the equivalent isotropically radiated power, in dBm EMeas is the field strength of the emission at the measurement distance, in dBμV/m dMeas is the measurement distance, in m Test Result of RF Exposure Evaluation wifi 2.4Gmode: ANT1&ANT2 MIMO Channel Output power to antenna (dBm) Output power to antenna (mW) Power Density at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result Antenna1 Antenna2 Antenna1 Antenna2 Antenna1 Antenna2 802.11b 12.89 12.82 19.4536 19.1426 0.00604 0.00532 1.0 PASS 802.11g 12.95 12.67 19.7242 18.4927 0.00612 0.00514 1.0 PASS 802.11n20 13.51 13.28 22.4388 21.2814 0.01320 0.01252 1.0 PASS 802.11n40 11.34 12.59 13.6144 18.1552 0.00801 0.01068 1.0 PASS Remark: antenna gain=1.93dBi(ANT1), 1.45dBi(ANT2) Directional Gain=4.71dBi. wifi 5G mode: ANT1&ANT2 SISO Band 1 Channel Output power to antenna (dBm) Output power to antenna (mW) Power Density at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result ANT1 ANT2 ANT1 ANT2 ANT1 ANT2 802.11a 9.802 9.747 9.5543 9.4341 0.00474 0.00413 1.0 PASS 802.11ac HT20 9.565 9.436 9.0469 8.7821 0.00846 0.00821 1.0 PASS 802.11 ac HT40 9.96 9.93 9.9083 9.8401 0.00926 0.00920 1.0 PASS 802.11 ac HT80 8.041 8.105 6.3694 6.4640 0.00595 0.00604 1.0 PASS 802.11n HT20 9.705 9.658 9.3433 9.2427 0.00873 0.00864 1.0 PASS 802.11n HT40 9.796 9.978 9.5411 9.9495 0.00892 0.00930 1.0 PASS Remark: antenna gain=3.97dBi(ANT1), 3.43dBi(ANT2) Directional Gain=6.72dBi. Band 4 Channel Output power to antenna (dBm) Output power to antenna (mW) Power Density at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result ANT1 ANT2 ANT1 ANT2 ANT1 ANT2 802.11a 10.636 10.636 11.5771 11.5771 0.00575 0.00507 1.0 PASS 802.11ac HT20 10.565 10.659 11.3894 11.6386 0.01065 0.01088 1.0 PASS 802.11 ac HT40 9.783 10.029 9.5126 10.0670 0.00889 0.00941 1.0 PASS 802.11 ac HT80 10.04 9.963 10.0925 9.9152 0.00943 0.00927 1.0 PASS 802.11n HT20 10.512 10.528 11.2512 11.2928 0.01052 0.01056 1.0 PASS 802.11n HT40 9.897 9.964 9.7656 9.9174 0.00913 0.00927 1.0 PASS Remark: antenna gain=3.97dBi(ANT1), 3.43dBi(ANT2) Directional Gain=6.72dBi. For BLE Field strength (dBuV/m) EIRP (dBm) Max tune-up (mW) Power Density at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 85.21 -9.95 0.1012 0.00003 1.0 PASS Remark: antenna gain= 1.93dBi For EDR Field strength (dBuV/m) EIRP (dBm) Max tune-up (mW) Power Density at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 85.24 -9.92 0.1019 0.00003 1.0 PASS Remark: antenna gain= 1.93dBi For Simultaneous transmitting, 1): The sum of the ratios of the spatially averaged results to the applicable frequency dependent MPE limits =0.0132/1+0.01252/1+0.00926/1+0.0093/1+0.01065/1+0.01088/1+ 0.00003/1=0.06584< 1 Since the sum of the MPE ratios for all simultaneously transmitting antennas incorporated in the device is ≤ 1.0, the EUT is considered to satisfy MPE compliance for simultaneous transmission operations.

Test Report

Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260317010R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 1 of 65 FCC Part 15C Test Report FCC ID: 2A9PI-LIXELHOLO1 Applicant: SHENZHEN XGRIDS-INNOVATION CO., LTD Address: 2403&2404, 24 Floor, Building 1B, Shenzhen International Innovation Valley, Liuxiandong, Nanshan District, Shenzhen, Guangdong, China Manufacturer: SHENZHEN XGRIDS-INNOVATION CO., LTD Address: 2403&2404, 24 Floor, Building 1B, Shenzhen International Innovation Valley, Liuxiandong, Nanshan District, Shenzhen, Guangdong, China Product Name: Mobile Lidar Scanner Trade Mark: XGRIDS、XGRIDS Lixel、Lixel Model Number: Lixel Holo 1 Date of Receipt: Mar. 17, 2026 Test Date: Mar. 17, 2026 - May 07, 2026 Date of Report: May 07, 2026 Prepared By: Shenzhen DL Testing Technology Co., Ltd. Address: 101-201, Comprehensive Building, Tongzhou Electronics Longgang Factory Area, No.1 Baolong Fifth Road, Baolong Community, Baolong Street, Longgang District, Shenzhen, China Applicable Standards: FCC PART 15 C 15.247 ANSI C63.10-2020+Cor 1-2023 KDB 662911 D01 Multiple Transmitter Output v02r01 Test Result: Pass Report Number: DLE-260317010R Prepared (Test Engineer): Ken Tan Reviewer (Supervisor): Jack Bu Approved (Manager): Jade Yang This test report is based on a single evaluation of one sample of above mentioned products. It is not permitted to be duplicated in extracts without written approval of Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260317010R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 2 of 65 Table of Contents Page 1 . SUMMARY OF TEST RESULTS 5 1.1 MEASUREMENT UNCERTAINTY 6 2 . GENERAL INFORMATION 7 2.1 GENERAL DESCRIPTION OF EUT 7 2.2 DESCRIPTION OF TEST MODES 8 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 9 2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) 9 2.5 TABLE OF PARAMETERS OF TEST SOFTWARE SETTING 9 2.6 EQUIPMENTS LIST FOR ALL TEST ITEMS 10 3 . EMC EMISSION TEST 11 3.1 CONDUCTED EMISSION MEASUREMENT 11 3.1.1 POWER LINE CONDUCTED EMISSION LIMITS 11 3.1.2 TEST PROCEDURE 11 3.1.3 DEVIATION FROM TEST STANDARD 11 3.1.4 TEST SETUP 12 3.1.5 EUT OPERATING CONDITIONS 12 3.1.6 TEST RESULTS 12 3.2 RADIATED EMISSION MEASUREMENT 15 3.2.1 RADIATED EMISSION LIMITS 15 3.2.2 TEST PROCEDURE 16 3.2.3 DEVIATION FROM TEST STANDARD 16 3.2.4 TEST SETUP 16 3.2.5 EUT OPERATING CONDITIONS 17 3.2.6 TEST RESULTS (BETWEEN 9KHZ – 30 MHZ) 18 3.2.7 TEST RESULTS (BETWEEN 30MHZ – 1GHZ) 19 3.2.8 TEST RESULTS (1GHZ~25GHZ) 21 3.3 RADIATED BAND EMISSION MEASUREMENT 25 3.3.1 TEST REQUIREMENT: 25 3.3.2 TEST PROCEDURE 25 3.3.3 DEVIATION FROM TEST STANDARD 25 3.3.4 TEST SETUP 26 3.3.5 EUT OPERATING CONDITIONS 26 3.4 CONDUCTED BAND EDGE EMISSION&CONDUCTED SPURIOUS EMISSIONS MEASUREMENT 31 3.4.1 APPLICABLE STANDARD 31 3.4.2 TEST PROCEDURE 31 Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260317010R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 3 of 65 Table of Contents Page 3.4.3 DEVIATION FROM STANDARD 31 3.4.4 TEST SETUP 31 3.4.5 EUT OPERATION CONDITIONS 31 3.4.6 TEST RESULTS 31 4 . AVERAGE OUTPUT POWER 36 4.1 APPLIED PROCEDURES / LIMIT 36 4.1.1 TEST PROCEDURE 36 4.1.2 DEVIATION FROM STANDARD 36 4.1.3 TEST SETUP 36 4.1.4 EUT OPERATION CONDITIONS 36 4.1.5 TEST RESULTS 37 5 . POWER SPECTRAL DENSITY TEST 42 5.1 APPLIED PROCEDURES / LIMIT 42 5.1.1 TEST PROCEDURE 42 5.1.2 DEVIATION FROM STANDARD 42 5.1.3 TEST SETUP 42 5.1.4 EUT OPERATION CONDITIONS 42 5.1.5 TEST RESULTS 43 6 . 6DB BANDWIDTH TEST 48 6.1 APPLIED PROCEDURES / LIMIT 48 6.1.1 TEST PROCEDURE 48 6.1.2 DEVIATION FROM STANDARD 48 6.1.3 TEST SETUP 48 6.1.4 EUT OPERATION CONDITIONS 48 6.1.5 TEST RESULTS 49 7 . DUTY CYCLE TEST SIGNAL 59 7.1 APPLIED PROCEDURES / LIMIT 59 7.1.1 TEST PROCEDURE 59 7.1.2 DEVIATION FROM STANDARD 59 7.1.3 TEST SETUP 59 7.1.4 EUT OPERATION CONDITIONS 59 7.1.5 TEST RESULTS 60 8 . ANTENNA REQUIREMENT 65 8.1 STANDARD REQUIREMENT 65 8.2 EUT ANTENNA 65 9 . TEST SETUP PHOTO 65 10 . EUT PHOTO 65 Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260317010R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 4 of 65 Table of Contents Page Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260317010R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 5 of 65 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15 (15.247) , Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission PASS 15.205, 15.209, 15.247(d) Radiated Spurious Emission PASS 15.247(d) Conducted Spurious Emissions PASS 15.205, 15.209, 15.247(d) Band Edge Emission PASS 15.247(b) Average Output Power PASS 15.247(a)(2) 6dB Bandwidth PASS 15.247(e) Power Spectral Density PASS 15.203 Antenna Requirement PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Test lab: Shenzhen DL Testing Technology Co., Ltd. Address: 101-201, Comprehensive Building, Tongzhou Electronics Longgang Factory Area, No.1 Baolong Fifth Road, Baolong Community, Baolong Street, Longgang District, Shenzhen, China The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the lssuing DL Testing Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the DL Testing, responsible for this Test Report. FCC Test Firm Registration Number: 854456 Designation Number: CN1307 IC Registered No.: 27485 CAB ID.: CN0118 Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260317010R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 6 of 65 1.1 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,pro…

Text truncated - open the document above for the full version.

Test Report

QR/RD-P01-06B SPECIFICATION Shenzhen Feixin Wireless Communication Co., Ltd. 2.4G/5.8 FPC antenna Product specification CustomerFrequency 2400——2500MHz 5150——5835MHZ R Fdesign XIAO BIN Version Technical director ANDYdate2026-04-20 Customer confirmation: Whether the assembly meets your company's requirements:□OK□NG http://www.fccant.comhttp://www.fly-core.com Page 2 Directory Cover.......................................................................................................1 1、Directory...........................................................................2 2、Product pictures...............................................................................3 3、S11 data.................................................................................4 4、Antenna test data (gain, efficiency, apple chart)...............4 5、Product structure drawing..........................................................9 http://www.fccant.comhttp://www.fly-core.com Page 3 1、Product pictures 2、Product parameters Product testing parameters 产品名称(Name) 2.4G WIFI 产品型号(Model Type) FX-PD2516-P2-WIFI- A-1.13B-220-4 电 性 能 指 标 (Electrical Specifications) 频率范围(Frenquency Range) 2400-2500MHZ 5200-5800MHZ 极化方式(Polarization) vertical 输入阻抗(Impedance) 50 Ω 辐射方向 Omnidirectional 驻波比 ( VSWR ) ≦3.0功率容量(Power) 5W 增益(Gain) 1.93/3.97 dBi 带宽(Bandwidth 100/600 MHz 机 械 指 标(Mechanical Specifications) 尺寸(Dimensions)29.6*10.4±0.15 mm外壳颜色(ANT Color) black 连接器型号(Connector) IPEX 4 引线长度(Cable Length)220±3 mm 外壳材料Radome Material FPC 工作温度 (Working Temperature) -40°C-+85°C 存放温度 (Limit Temperature) -40°C-+85°C http://www.fccant.comhttp://www.fly-core.com Page 4 3. VSWR, Retu…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Zhixin Chen(Project Manager)
[email protected]Fax: +86-18825284823

Technical Contact

Herland International Trading IncJianfeng Gao
[email protected]

1370 Valley Vista Dr Ste200 Diamond Bar California · Diamond Bar, California, 91765-3921 · United States

Test Firm

Shenzhen DL Testing Technology Co., Ltd.Jade Yang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz43.75 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. Device is a 2x2 MIMO configuration as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons. End-users must be provided with operating procedures for satisfying RF exposure compliance.The device contains 20MHz and 40MHz.

Other Applications from SHENZHEN XGRIDS-INNOVATION CO., LTD

Mobile Lidar Scanner - FCC ID 2A9PI-LIXELL2 - SHENZHEN XGRIDS-INNOVATION CO., LTD
2A9PI-LIXELL2

Mobile Lidar Scanner

Jul 04, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2A9PI-K1

Mobile Lidar Scanner

Apr 14, 2024

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Lixel L2 300 V1 - FCC ID 2A9PI-L2300V1 - SHENZHEN XGRIDS-INNOVATION CO., LTD
2A9PI-L2300V1

Lixel L2 300 V1

Dec 26, 2023

Equipment Class

DTS - Digital Transmission System
Mobile Lidar Scanner - FCC ID 2A9PI-L1 - SHENZHEN XGRIDS-INNOVATION CO., LTD
2A9PI-L1

Mobile Lidar Scanner

Mar 02, 2023

Equipment Class

NII - Unlicensed National Information Infrastructure TX