  2. Qolsys, Inc./
  3. 2AAJXQS1200

2AAJXQS1200is a wireless motion sensor to be used in the Qolsys IQ home security system.

Qolsys, Inc.
is a wireless  motion sensor to be used in the Qolsys IQ home security system. - FCC ID 2AAJXQS1200 - Qolsys, Inc.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Aug 23, 2015
Application Purpose
Original Equipment
Date of Application
Aug 23, 2015
Equipment Note
is a wireless motion sensor to be used in the Qolsys IQ home security system.
Frequency Range
319.50000000 - 319.50000000
Company
Qolsys, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗
↗

ID Label/Location Info

↗
↗

Internal Photos

↗
↗
↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

IQ MOTION- INSTALLATION MANUAL QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE 1 OF 6 © Last revised 2/27/15 All rights reserved The Qolsys IQ Motion is a high-performance wireless motion sensor that uses advanced power circuit technology to extend battery life. The tamper-resistant casing along with an electronic sensor discourages physical tampering and the sensor is equipped with a pet immunity feature that prevents accidental triggers by household pets. The IQ Motion works seamlessly with the Qolsys IQ Panel. • Advanced circuit technology resulting in ultra-low power consumption • Tamper detection/reporting • Rigid wall mounting for discreet placement • Pet immunity • Easy to install batteries • Supervisory health messaging • Sensor Motion detection • Transmits 2 signals per 5 minute period PIR (Passive Infrared) Motion Sensors 2 Mounting screws 2 AAA Alkaline batteries PRODUCT FEATURESPARTS INCLUDED IQ MOTION • Wireless signal range: 600 ft (200 m), open air • Code outputs: paring, tamper, tamper restore, alarm detect motion, alarm restore, supervisory, low battery • Transmitter frequency: 319.5MHZ +-15KHz • Transmitter bandwidth: 24KHZ • Modulation type: ASK-OOK • RF output power 91.1dBuV +/- 5% at 3m • Sensor Range 30 ft (9.1 m) x 50 ft (15.2 m) • Maximum Horizontal Sensing Angle 80° TECHNICAL SPECIFICATIONS IQ MOTION- INSTALLATION MANUAL QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE 2 OF 6 © Last revised 2/27/15 All rights reserved •IQMotionSensor is designed for indoor use and is compatible with homes where pets up to 40 lbs (18 kg) are present. To minimize the possibility of false alarms the following guidelines should be followed: • The sensor may be mounted in a corner or on a flat wall that is free of vibrations. •If possible, mount the sensor within 100 ft (30.5 m) of the panel. While the transmitter may have a range of 600 ft (200 m) or more out in the open, the environment at the installation site can have a significant effect on transmitter range. Verify actual transmitter range for each installation. • Position the sensor to protect an area where an intruder is most likely to walk across the detection pattern. • Mount the sensor permanently on a flat wall or in a corner. • Mount the sensor on an interior wall facing in. • Position the sensor so it faces a solid reference point, such as a wall. • Close all windows in an area with an armed motion sensor. DO NOT: • Aim the sensor at windows, fireplaces, air conditioners, area heaters, or forced air heating vents. • Place the sensor in direct sunlight as sudden changes in temperature may trigger a false alarm. • Mount the sensor near duct work or other large metallic surfaces that may affect the RF signals. • Set the sensor on a shelf. GUIDELINES Flush-mount or corner-mount the sensor depending on the selected location and desired coverage area MOUNTING OPTIONS BATTERY ACTIVATION To activate the batteries in the sensor, remove the cover and pull out the plastic tab between the batteries and the contacts. CORNER STRAIGHT MOUNT CORNER ANGLE DOWN MOUNT FLUSH WALL MOUNT For pet immunity from a corner For pet immunity No pet immunity IQ MOTION- INSTALLATION MANUAL QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE 3 OF 6 © Last revised 2/27/15 All rights reserved MOUNTING INSTRUCTIONS Remove back cover by pressing bottom button and sliding back cover off in an upward motion. If a flush mount is required screw in the back cover on the wall using the screw templates as shown. If corner mount is required use the screw templates as shown. MOUNTING FOR PET SENSITIVITY Mount the sensor 6.5 to 7 ft (0.9 and 1.5 m) high. For best results, install the sensor higher than the highest point the pet might reach in the detection area. Use the following formula to calculate the optimal mount height: mount height = pet’s stature + (distance/20). That means when the farthest sense area to sensor is 33 ft (10 m), and the pet’s stature is 2.6 ft (0.8 m), mount 4.25 ft (1.3 m) from the floor. (Do not exceed the highest 5 ft [1.5 m]). If the detection area contains furniture or other objects on which the pet can climb or jump, either (a) remove these objects, (b) mount the sensor a safe distance above these objects, or (c) mask these areas. IQ MOTION- INSTALLATION MANUAL QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE 4 OF 6 © Last revised 2/27/15 All rights reserved PROGRAMMING THE IQ DOOR/WINDOW The following steps describe general guidelines for programming (learning) the sensor into the IQ Panel. Refer to the IQ Panel's installation instructions for complete programming details. From the home screen of the IQ panel, touch the “Settings” icon Enter the installer passcode. Default installer passcode is 111112 Touch the “Installation” appTouch the “Security Sensors” app 34 Touch the “AutoLearn Sensor” app Tamper the sensor by pressing the tab and liBing off the cover. 54 A chime will sound Touch “Ok” 67 8 Check the auto-populated fields to ensure accuracy. Change the settings as you see fit. Be sure to select the proper “Sensor Group” 9 Create custom names by selecting “Sensor name” and choosing “Custom description.” A box will appear to the right. Selecting that box will open a keyboard, allowing you to type the name of your choice into the field. 10 Touch “Add” to complete the process IQ MOTION- INSTALLATION MANUAL QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE 5 OF 5 © Last revised 2/27/15 All rights reserved BATTERY REPLACEMENT To replace batteries: • Push button on side of sensor and lift off cover. • Remove old batteries and replace with new ones. • Close cover by snapping the cover back onto the sensor. AAA Alkaline (2 per sensor) Battery life expectancy: 3 years. (Lifetime may vary depending on number of activations, environmental conditions, etc.) BATTERY TYPE Operating Temperature: -10C~50C (TBD) Relative Humidity: 5-85% Storage Temperature: -40-80C ENVIRONMENTAL CHARACTERISTICS Sensor: 3.4H x 2.4W x 1.5D in. (7.7x6.0x4.3 cm) Number of sensing elements: 2 Spectral Response…

Text truncated - open the document above for the full version.

Users Manual

IQ MOTION QUICK INSTALL GUIDE X ✓ Avoid placement near ceiling fans Corners above doors are great locations ✓ Corners pointed away from windows are great locations X Avoid HVAC ducts X ✓ Install at least 7.5’ (2.3m) high STEP 1 CHOOSE INSTALLATION LOCATION OPEN DEVICE CASING REMOVE BATTERY TAB CHOOSE MOUNTING TYPE CORNER ANGLE DOWN MOUNT CORNER STRAIGHT MOUNT SECURE ALL HARDWARE FLUSH WALL MOUNT DIMENSION (Unit = m/m) DETECTING AREA (Unit = meter) 40lbs at 35’ SPECIFICATION CHARTS LEARN INTO PANEL e. Trip sensor by opening casing until you hear the panel chime f. Check information on panel, make any changes and click “Save” g. Test sensor to ensure proper function ✓ GOT QUESTIONS? CONTACT TECH SUPPORT [email protected] SUPPORT STEP 2 STEP 3 STEP 4 STEP 5 STEP 4 a. Touch “Settings” b. Touch “Installation” d. Touch “Quick Install” c. Touch “Security Sensors” Document#: IQDW-QG-07-13 Revision#: 20121130 Issue Date: 11-30-2012 Qolsys Part #: QS-1200-p01 Firmware : 20130401 Qolsys Inc. proprietary. Reproduction without permission is not permitted. DOCUMENTATION INFORMATION

ID Label/Location Info

45 51 scale:1:1, unit:mm Note: 1. Font size: 1.5mm Made in China P/N: QS-1200-P01 Model: IQMotion 4009595 SN: QSBX12WW00001 Tx ID ABCDEF DLEFCDAB This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference and (2) this device must accept any int erference received, including int erference that may cause undesired operation. Replace Battery with 2= AAA 1.5V Alkaline Batteries ONLY. See User’s Manual for safety instructions 09/2013 FCC ID: 2AAJXQS1200 IC: 11205A-QS1200 Conforms to ANSI/UL Std 639 Certified to ULC Std S306

ID Label/Location Info

Label Location

Test Report

This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Non-Specific EMC Report Shell Rev. July 2013 Page 1 of 24 Qolsys Inc. IQMotion EMC TEST REPORT Report Number: 101052328ATL-007A Project Number: G10152328 Report Issue Date: November 25, 2014 Report Revised Date: April 9, 2015 Product Designation: IQMotion, QS1200 Standards: 47 CFR Part 15 Subpart C:2014 Section 15.231 RSS-210 Issue 8, 2010 Tested by: Client: Intertek Testing Services NA, Inc. 1950 Evergreen Blvd, Suite 100 Duluth, GA 30096 USA Qolsys Inc. 1900 The Alameda, Suite 420 San Jose, CA. 95126 USA Report prepared by Report reviewed by Mary Sampson/Senior Project Engineer Krishna Vemuri/Senior Staff Engineer Intertek Report Number: 101052328ATL-007A Issued: 04/09/2015 Non-Specific EMC Report Shell Rev. July 2013 Page 2 of 24 Qolsys Inc. IQMotion 1 Introduction and Conclusion The tests indicated in section 2.0 were performed on the product constructed as described in section 4.0. The remaining test sections are the verbatim text from the actual data sheets used during the investigation. These test sections include the test name, the specified test Method, a list of the actual Test Equipment Used, documentation Photos, Results and raw Data. No additions, deviations, or exclusions have been made from the standard(s) unless specifically noted. Based on the results of our investigation, we have concluded the product tested complies with the requirements of the standard(s) indicated. The results obtained in this test report pertain only to the item(s) tested. 2 Test Summary Section Test full name Result 3 Client Information 4 Description of Equipment Under Test 5 System Setup and Method 6 Restrictions (47 CFR Part 15 Subpart C:2014 Section 15.231(a)(2) RSS-210 Issue 8, 2010, Section A1.1.1(b)) Pass - AC Mains Conducted Emissions (Battery operated device) N/A 7 Fundamental Emissions (47 CFR Part 15 Subpart C:2014 Section 15.231(b) RSS-210 Issue 8, 2010, Section A1.1.2) Pass 8 Radiated Spurious Emissions below 1GHz (47 CFR Part 15 Subpart C:2014 Section 15.231(b) RSS-210 Issue 8, 2010, Section A1.1.2) Pass 9 Radiated Spurious Emissions Above 1 GHz (47 CFR Part 15 Subpart C:2014 Section 15.231(b) RSS-210 Issue 8, 2010, Section A1.1.2) Pass 10 Bandwidth (47 CFR Part 15 Subpart C:2014 Section 15.231(c) RSS-210 Issue 8, 2010, Section A1.1.3) Pass 11 Duty Cycle (47 CFR Part 15 Subpart C:2014 Section 15.35(c) RSS-GEN Issue 3, 2010, Section 4.5) Pass 12 RF Exposure Compliance (47 CFR Part 2 Subpart J: 2014 Section 2.1091) Pass 13 Revision History Intertek Report Number: 101052328ATL-007A Issued: 04/09/2015 Non-Specific EMC Report Shell Rev. July 2013 Page 3 of 24 Qolsys Inc. IQMotion 3 Client Information This EUT was tested at the request of: Client: Qolsys Inc. 1900 The Alameda, Suite 420 San Jose, CA. 95126 USA Contact: Mark Skeen Telephone: 408-857-8415 Fax: 408-927-5832 Email: [email protected] 4 Description of Equipment Under Test Manufacturer: Qolsys Inc. 1 900 The Alameda, Suite 420 San Jose, CA. 95126 USA Equipment Under Test Description Manufacturer Model Number Serial Number Wireless Motion Detector Qolsys Inc IQMotion QSBB134400052 Wireless Motion Detector Qolsys Inc IQMotion QSBB134400054 Receive Date: 10/16/2014 Received Condition: Good Type: Production Description of Equipment Under Test (provided by client) The IQMotion is a wireless motion detector to be used in the Qolsys IQ home security system. Equipment Under Test Power Configuration Rated Voltage Rated Current Rated Frequency Number of Phases 2.2 to 3 Vdc 30 μA N/A N/A Operating modes of the EUT: No. Descriptions of EUT Exercising 1 Continuous Transmission is a special test mode used only for simplifying the compliance testing process. This will never be activated by the end user. 2 Normal mode is transmission upon sensor activation or at supervisory interval (approximately 70 minutes). Software used by the EUT: No. Descriptions of EUT Exercising 1 None provided Intertek Report Number: 101052328ATL-007A Issued: 04/09/2015 Non-Specific EMC Report Shell Rev. July 2013 Page 4 of 24 Qolsys Inc. IQMotion 5 System Setup and Method Cables ID Description Length (m) Shielding Ferrites Termination None Support Equipment Description Manufacturer Model Number Serial Number None 5.1 Method: Configuration as required by ANSI C63.10: 2013. 5.2 EUT Block Diagram: IQMotion Intertek Report Number: 101052328ATL-007A Issued: 04/09/2015 Non-Specific EMC Report Shell Rev. July 2013 Page 5 of 24 Qolsys Inc. IQMotion 6 Restrictions 6.1 Method Tests are performed in accordance with 47 CFR Part 15 Subpart C:2014 Section 15.231(a)(2) and RSS- 210 Issue 8, 2010, Section A1.1.1(b). TEST SITE: 10m Semi-Anechoic Chamber Control Room 10 Meter Semi-Anechoic Chamber The test site for radiated emissions is located at 1950 Evergreen Blvd, Suite 100, Duluth, Georgia 30096. It is a 10 meter semi-anechoic chamber manufactured by Panashield. Embedded in the floor is a 3 meter diameter turntable. 6.2 Test Equipment Used: Asset Description Manufacturer Model Serial Cal Date Cal Due T006217; THDX Oregon Scientific BA888 NSN 12/11/2013 12/11/2014 211505; EMI Receiver Hewl…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Mark Skeen(VP Business Development, Global Products)
[email protected]408-857-8415Fax: 408-927-5832

Technical Contact

Intertek Testing Services NA, Inc.Mary Sampson
[email protected]678-775-2400

1950 Evergreen Blvd · Duluth, Georgia · United States

Non-Technical Contact

Intertek Testing Services NA, Inc.Mary Sasmpson
[email protected]678-775-2400

Test Firm

Intertek Testing Services NA Inc.Charles Parker
[email protected]972-202-8764Fax: 6787752401

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231319.5 MHz - 319.5 MHz-
Confidentiality
Long Term

Other Applications from Qolsys, Inc.

PowerG Wirefree Keypad with prox - FCC ID 2AAJXQS-IQKP - Qolsys, Inc.
2AAJXQS-IQKP

PowerG Wirefree Keypad with prox

Aug 19, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Door Sensor Alarm System - FCC ID 2AAJXQS-IQDWM - Qolsys, Inc.
2AAJXQS-IQDWM

Door Sensor Alarm System

Aug 03, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Zwave 800 Radio - FCC ID 2AAJXQS-IQP4Z - Qolsys, Inc.
2AAJXQS-IQP4Z

Zwave 800 Radio

Feb 27, 2023

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
IQ WiFi 6 - FCC ID 2AAJXQS-IQWIFI6 - Qolsys, Inc.
2AAJXQS-IQWIFI6

IQ WiFi 6

Aug 25, 2021

Equipment Class

DTS - Digital Transmission System
Zwave Module - FCC ID 2AAJXQS-ZWAVEAH - Qolsys, Inc.
2AAJXQS-ZWAVEAH

Zwave Module

Oct 29, 2020

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified