Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC Warning Statement of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Consult the dealer or an experienced radio/TV technician for help Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. INDUSTRY CANADA NOTICES (IC): This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device Avis d'Industrie Canada (IC): Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS (s). Son fonctionnement est soumisaux deux conditions suivantes: (1) cet appareil ne doit pas provoquer d'interférences et (2) cet appareil doit accepter toute interférence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil
DATE : Oct 24, 2014 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2ABDT-TQ10A10 Product Name: MID Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: • Schematics • Block diagram • Operational Description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Dated this Oct 24, 2014 Agency agreement expiration date: Usually Give 8 - 12 Months By: Luo Albert Signature Printed Title: Manager On behalf of : JIANGSU SHUANGSHUANG TECHNOLOGY CO,LTD. Telephone: +86-513-88355088
Statement We JIANGSU SHUANGSHUANG TECHNOLOGY CO,LTD. Are applying for FCC DOC for MID with model number: D2-1014W FCC DOC is doing at FCC Authorized and Recognized lab. The FCC DOC application will be completed before sell. Your assistance on this matter is highly appreciated. Yours sincerely, Dated this Oct 24, 2014 Agency agreement expiration date: Usually Give 8 - 12 Months By: Luo Albert Signature Printed Title: Manager On behalf of : JIANGSU SHUANGSHUANG TECHNOLOGY CO,LTD. Telephone: +86-513-88355088
Outside view Outside view Outside view
Product Name: MID Model No.: D2-10 14 W FCC ID:2ABDT-TQ 10 A10 IC : 12136A-TQ 10 A10 Input: DC5V, 2.5A JIANGSU SHUANGSHUANG TECHNOLOGY CO., LTD. Warning: This device complies with FCC Part 15 and Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Label Location
Inside view Inside view Inside view Inside view Inside view Inside view
RF Exposure Applicable Standard According to §1.1307(b)(5), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. This is a Portable device. The Section 4.3.1 and Appendix A of KDB447498 D01 V05 was used as the guidance. Calculation Result (Worse Case): WIFI Mode [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] =9.40/5 * 1.57= 2.95, this value is less than 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR. Bluetooth Mode [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] =3.39/5 * 1.57= 1.06, this value is less than 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR. Note: WIFI and Bluetooth can not transmit at the time. The SAR measurement is not necessary.
ISO/IEC17025Accredited Lab. Report No: FCC/IC 1409185-01 File reference No: 2014-10-29 Applicant: JIANGSU SHUANGSHUANG TECHNOLOGY CO., LTD. Product: MID Model No: D2-1014W Trademark: N/A Test Standards: FCC Part 15.247 and RSS-210 Test result: It is herewith confirmed and found to comply with the requirements set up by ANSI C63.4, ,FCC Part 15 Subpart C, Paragraph 15.247 regulations and RSS-210 for the evaluation of electromagnetic compatibility Approved By Jack Chung Manager Dated: October 29, 2014 Results appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO., LTD 5/F,Block 4, Anhua Industrial Zone., No.8 TaiRan Rd. CheGongMiao, FuTian District, Shenzhen, CHINA. Tel (755) 83448688, Fax (755) 83442996, E-Mail:[email protected] Report No: FCC/IC1409185-01 Page 2 of 92 Date: 2014-10-29 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the Shenzhen Timeway Technology Consulting Co .,Ltd. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the Shenzhen Timeway Technology Consulting co .,Ltd to his customer. Supplier or others persons directly concerned. Shenzhen Timeway Technology Consulting co .,Ltd will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The Shenzhen Timeway Technology Consulting co .,Ltd reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Special Statement: The testing quality ability of our laboratory meet with "Quality Law of People's Republic of China" Clause 19. The testing quality system of our laboratory meets with ISO/IEC-17025 requirements, which is approved by CNAS. This approval result is accepted by MRA of APLAC. Our test facility is recognized, certified, or accredited by the following organizations: CNAS-LAB Code: L2292 The EMC Laboratory has been assessed and in compliance with CNAS-CL01 accreditation criteria for testing Laboratories (identical to ISO/IEC 17025:1999 General Requirements) for the Competence of testing Laboratories. FCC-Registration No.: 899988 The EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications commission. The acceptance letter from the FCC is maintained in our files. Registration No.:899988. IC- Registration No.: IC5205A-02 The EMC Laboratory has been registered and fully described in a report filed with the (IC) Industry Canada. The acceptance letter from the IC is maintained in our files. Registration No.: IC 5205A-02. Report No: FCC/IC1409185-01 Page 3 of 92 Date: 2014-10-29 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the Shenzhen Timeway Technology Consulting Co .,Ltd. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the Shenzhen Timeway Technology Consulting co .,Ltd to his customer. Supplier or others persons directly concerned. Shenzhen Timeway Technology Consulting co .,Ltd will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The Shenzhen Timeway Technology Consulting co .,Ltd reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Test Report Conclusion Content 1.0 General Details ................................................................................................ 4 1.1 Test Lab Details................................................................................................ 4 1.2 Applicant Details.............................................................................................. 4 1.3 Description of EUT .......................................................................................... 4 1.4 Submitted Sample............................................................................................. 4 1.5 Test Duration.................................................................................................... 4 1.6 Test Uncertainty.................................................................................................5 1.7 Test By.......................................................................................................... 5 2.0 List of Measurement Equipment......................................................................... 6 3.0 Technical Details............................................................................................. 7 3.1 Summary of Test Results..................................................................................... 7 3.2 Test Standards.................................................................................................. 7 4.0 EUT Modification............................................................................................. 7 5.0 Power Line Conducted Emission Test...................................................................... 8 5.1 Schematics of the Test........................................................................................ 8 5.2 Test Method and Test Procedure............................................................................ 8 5.3 Configuration of the EUT.................................................................................... 8 5.4 EUT Operating Condition.....…
Text truncated - open the document above for the full version.
Conducted Emission Test Setup: Radiated Emission Test Setup:
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 3.39 mW |

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
tablet PC
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
MID
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
MID
Equipment Class
DTS - Digital Transmission System
MID
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter