FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. JIANGSU SHUANGSHUANG TECHNOLOGY CO,LTD./
  3. 2ABDT-TQ8A10

2ABDT-TQ8A10MID

JIANGSU SHUANGSHUANG TECHNOLOGY CO,LTD.
MID - FCC ID 2ABDT-TQ8A10 - JIANGSU SHUANGSHUANG TECHNOLOGY CO,LTD.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 08, 2014
Application Purpose
Original Equipment
Date of Application
Nov 08, 2014
Equipment Note
MID
Frequency Range
2402.00000000 - 2480.00000000
Company
JIANGSU SHUANGSHUANG TECHNOLOGY CO,LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Tablet Instruction Windows 8.1 FCC Warning Statement of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Consult the dealer or an experienced radio/TV technician for help Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. INDUSTRY CANADA NOTICES (IC): This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device Avis d'Industrie Canada (IC): Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS (s). Son fonctionnement est soumisaux deux conditions suivantes: (1) cet appareil ne doit pas provoquer d'interférences et (2) cet appareil doit accepter toute interférence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil Attentions: This manual includes important safety instructions and the information on how to use correctly, for avoid the accidents happening, so ensure you should read the manual before using the product. ● Please don’t put the product on the places with high temperature, humidity or more dust. ● Please don’t put the product on the places with high temperature, especially not put the products in a car with close windows in summer. ● Not fall off or knock this product strongly, not let IPS panel be shocked, otherwise it may cause IPS panel broken or display abnormal. ● Please choose the right sound volume, not too big when use earphone, if feel tinnitus, please turn down the volume or stop using. ● Please do the charge when meet below situations: A. When the icon of battery capacity display no electricity. B. System power off automatically, the unit will be power off fast after powering on again. C. No response when press the power button. ● Please not open the link suddenly when the player is doing format or the unit is uploading or downloading, otherwise it will cause the procedure error. ● For the products broken, repair or other reasons caused the memory information lost, our company will be not responsible for this, please follow the manual to do operations. ● Please not tear down the unit, not use the alcohol, diluents or benzene to clear the products. ● Not use this unit in the forbidden area(such as airplane). ● Not use this unit when driving or walking, otherwise it will cause the accidents. ※ Our company will keep the right with products’ improving, specifications and designs, and not do the notice. ★ (This product have no function with waterproof) 【Remark】:The pictures in operation manual just for reference. 1. Major parameters:  CPU: Intel 3735D Baytrail-T Quad core  Display:8 IPS capacitive panel  Resolution ratio: 800x1280  Storage: 16G flash  OS: Windows 8.1  RAM: 1GB  Battery capacity: 3800mAH  Camera: 0.3M(Front) and 2M(Rear)Pixel 2. Cosmetic and button instruction Number introduction as below: 1) Micro USB Can connect the devices with USB keyboard, mouse and U disk... 2) HDMI HDMI can exchange to external High-definition LCD. 3) Dual using jack with 3.5mm earphone and MIC Can output the sound signals of computer to external speaker or earphone. 4) Front camera Take a picture or video for front. 5) Touch panel Can operate the unit by touching. 6) Windows logo Can back to original desktop. 7) Stereo speaker port For output the external voice. 8) Power button Starting up with short press, or enter standby status, or wake up from standby. Keeping press 4s to enter shut down interface, and keep pressing 10s to compel the unit shut down. 9) Volume button Volume up and down. 10) Micro SD slot Can support the card with Micro SD and Micro SD HC. 11) Internal MIC Using for video meeting, sound control and record. 12) Rear Camera Rear camera can take a picture and video. 3. Using your tablet ● Starting up: Press the power button to power on(Remark: the tablet no response if Pressing the power button, your tablet may need do the charge). ● Shut down: Starting up with short press, or enter standby status, or wake up from Standby(Remark: Keeping press 4s to enter shut down interface, and keep pressing 10s to compel the unit shut down). ● Standby: Press the power button during the unit is working, can do save for the Power, and wake up quickly. ● Restart: Open the right super column, click the power, then click “restart”, the unit will start to do restart procedure.

Cover Letter(s)

DATE : Oct 24, 2014 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2ABDT-TQ8A10 Product Name: MID Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: • Schematics • Block diagram • Operational Description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Dated this Oct 24, 2014 Agency agreement expiration date: Usually Give 8 - 12 Months By: Luo Albert Signature Printed Title: Manager On behalf of : JIANGSU SHUANGSHUANG TECHNOLOGY CO,LTD. Telephone: +86-513-88355088

Cover Letter(s)

Statement We JIANGSU SHUANGSHUANG TECHNOLOGY CO,LTD. Are applying for FCC DOC for MID with model number: D2-801W FCC DOC is doing at FCC Authorized and Recognized lab. The FCC DOC application will be completed before sell. Your assistance on this matter is highly appreciated. Yours sincerely, Dated this Oct 24, 2014 Agency agreement expiration date: Usually Give 8 - 12 Months By: Luo Albert Signature Printed Title: Manager On behalf of : JIANGSU SHUANGSHUANG TECHNOLOGY CO,LTD. Telephone: +86-513-88355088

External Photos

Outside view Outside view Outside view

ID Label/Location Info

Product Name: MID Model No.: D2- 801W FCC ID:2ABDT-TQ 8A10 IC : 12136A-TQ 8A10 Input: DC5V, 2.5A JIANGSU SHUANGSHUANG TECHNOLOGY CO., LTD. Warning: This device complies with FCC Part 15 and Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

ID Label/Location Info

Label Location

Internal Photos

Inside view Inside view Inside view Inside view Inside view Inside view

RF Exposure Info

RF Exposure Applicable Standard According to §1.1307(b)(5), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. This is a Portable device. The Section 4.3.1 and Appendix A of KDB447498 D01 V05 was used as the guidance. Calculation Result (Worse Case): WIFI Mode [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] =9.27/5 * 1.57= 2.91, this value is less than 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR. Bluetooth Mode [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] =3.30/5 * 1.57= 1.04, this value is less than 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR. Note: WIFI and Bluetooth can not transmit at the time. The SAR measurement is not necessary.

Test Report

ISO/IEC17025Accredited Lab. Report No: FCC/IC 1409180-02 File reference No: 2014-10-24 Applicant: JIANGSU SHUANGSHUANG TECHNOLOGY CO., LTD. Product: MID Model No: D2-801W Trademark: N/A Test Standards: FCC Part 15 Subpart C, Paragraph 15.247 and RSS-210 Test result: It is herewith confirmed and found to comply with the requirements set up by ANSI C63.4, ,FCC Part 15 Subpart C, Paragraph 15.247 regulations and RSS-210 for the evaluation of electromagnetic compatibility Approved By Jack Chung Manager Dated: October 24, 2014 Results appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD 5/F,Block 4, Anhua Industrial Zone.,No.8 TaiRan Rd.CheGongMiao,FuTian District, Shenzhen,CHINA. Tel (+86 755)8344 8688 Fax (+86 755)8344 2996 Email:[email protected] Report No: FCC/IC1409180-02 Page 2 of 52 Date: 2014-10-24 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the Shenzhen Timeway Technology Consulting Co .,Ltd. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the Shenzhen Timeway Technology Consulting co .,Ltd to his customer. Supplier or others persons directly concerned. Shenzhen Timeway Technology Consulting co .,Ltd will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The Shenzhen Timeway Technology Consulting co .,Ltd reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Special Statement˖ The testing quality ability of our laboratory meet with “Quality Law of People’s Republic of China” Clause 19. The testing quality system of our laboratory meet with ISO/IEC-17025 requirements, which is approved by CNAL. This approval result is accepted by MRA of APLAC. Our test facility is recognized, certified, or accredited by the following organizations: CNAL-LAB Code: L2292 The EMC Laboratory has been assessed and in compliance with CNAL/AC01:2002 accreditation criteria for testing Laboratories (identical to ISO/IEC 17025:1999 General Requirements) for the Competence of testing Laboratories. FCC-Registration No.: 899988 The EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications commission. The acceptance letter from the FCC is maintained in our files. Registration No.: 899988. IC-Registration No.: IC5205A-02 The EMC Laboratory has been registered and fully described in a report filed with the (IC) Industry Canada. The acceptance letter from the IC is maintained in our files. Registration IC No.: 5205A-02. Report No: FCC/IC1409180-02 Page 3 of 52 Date: 2014-10-24 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the Shenzhen Timeway Technology Consulting Co .,Ltd. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the Shenzhen Timeway Technology Consulting co .,Ltd to his customer. Supplier or others persons directly concerned. Shenzhen Timeway Technology Consulting co .,Ltd will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The Shenzhen Timeway Technology Consulting co .,Ltd reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Test Report Conclusion Content 1.0 General Details ................................................................................................ 4 1.1 Test Lab Details................................................................................................ 4 1.2 Applicant Details.............................................................................................. 4 1.3 Description of EUT ........................................................................................... 4 1.4 Submitted Sample.............................................................................................. 4 1.5 Test Duration................................................................................................... 4 1.6 Test Uncertainty............................................................................................... 5 1.7 Test By.......................................................................................................... 5 2.0 List of Measurement Equipment......................................................................... 6 3.0 Technical Details............................................................................................. 7 3.1 Summary of Test Results..................................................................................... 7 3.2 Test Standards.................................................................................................. 7 4.0 EUT Modification.............................................................................................7 5.0 Power Line Conducted Emission Test...................................................................... 8 5.1 Schematics of the Test........................................................................................ 8 5.2 Test Method and Test Procedure............................................................................ 8 5.3 Configuration of the EUT.................................................................................... 8 5.4 EUT…

Text truncated - open the document above for the full version.

Test Report

ISO/IEC17025Accredited Lab. Report No: FCC/IC 1409180-03 File reference No: 2014-10-24 Applicant: JIANGSU SHUANGSHUANG TECHNOLOGY CO., LTD. Product: MID Model No: D2-801W Trademark: N/A Test Standards: FCC Part 15.247 and RSS-210 Test result: It is herewith confirmed and found to comply with the requirements set up by ANSI C63.4, ,FCC Part 15 Subpart C, Paragraph 15.247 regulations and RSS-210 for the evaluation of electromagnetic compatibility Approved By Jack Chung Manager Dated: October 24, 2014 Results appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO., LTD 5/F,Block 4, Anhua Industrial Zone.,No.8 TaiRan Rd.CheGongMiao,FuTian District, Shenzhen,CHINA. Tel (755) 83448688, Fax (755) 83442996, E-Mail:[email protected] Report No: FCC/IC1409180-03 Page 2 of 121 Date: 2014-10-24 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the Shenzhen Timeway Technology Consulting Co .,Ltd. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the Shenzhen Timeway Technology Consulting co .,Ltd to his customer. Supplier or others persons directly concerned. Shenzhen Timeway Technology Consulting co .,Ltd will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The Shenzhen Timeway Technology Consulting co .,Ltd reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Special Statement˖ The testing quality ability of our laboratory meet with “Quality Law of People’s Republic of China” Clause 19. The testing quality system of our laboratory meet with ISO/IEC-17025 requirements, which is approved by CNAL. This approval result is accepted by MRA of APLAC. Our test facility is recognized, certified, or accredited by the following organizations: CNAL-LAB Code: L2292 The EMC Laboratory has been assessed and in compliance with CNAL/AC01:2002 accreditation criteria for testing Laboratories (identical to ISO/IEC 17025:1999 General Requirements) for the Competence of testing Laboratories. FCC-Registration No.: 899988 The EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications commission. The acceptance letter from the FCC is maintained in our files. Registration No.: 899988. IC-Registration No.: IC5205A-02 The EMC Laboratory has been registered and fully described in a report filed with the (IC) Industry Canada. The acceptance letter from the IC is maintained in our files. Registration IC No.: 5205A-02. Report No: FCC/IC1409180-03 Page 3 of 121 Date: 2014-10-24 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the Shenzhen Timeway Technology Consulting Co .,Ltd. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the Shenzhen Timeway Technology Consulting co .,Ltd to his customer. Supplier or others persons directly concerned. Shenzhen Timeway Technology Consulting co .,Ltd will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The Shenzhen Timeway Technology Consulting co .,Ltd reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Test Report Conclusion Content 1.0 General Details ................................................................................................ 4 1.1 Test Lab Details................................................................................................ 4 1.2 Applicant Details.............................................................................................. 4 1.3 Description of EUT .......................................................................................... 4 1.4 Submitted Sample............................................................................................. 5 1.5 Test Duration.................................................................................... 5 1.6 Test Uncertainty.................................................................................. 5 1.7 Test By.......................................................................................................... 5 2.0 List of Measurement Equipment......................................................................... 6 3.0 Technical Details............................................................................................. 8 3.1 Summary of Test Results..................................................................................... 8 3.2 Test Standards.................................................................................................. 8 4.0 EUT Modification.............................................................................................8 5.0 Power Line Conducted Emission Test...................................................................... 9 5.1 Schematics of the Test........................................................................................ 9 5.2 Test Method and Test Procedure............................................................................ 9 5.3 Configuration of the EUT.................................................................................... 9 5.4 EUT Operating Condition...................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Conducted Emission Test Setup: Radiated Emission Test Setup:

Contact Information

Applicant

Luo Albert
[email protected]+86-513-88355088Fax: +86-513-88355618

Test Firm

Shenzhen Timeway Testing LaboratoriesJack Chung
[email protected]0755-83448688Fax: 86-755-83442996

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.40 GHz - 2.48 GHz1.04 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. This device has a 20 MHz and 40 MHz bandwidth mode.

Other Applications from JIANGSU SHUANGSHUANG TECHNOLOGY CO,LTD.

MID - FCC ID 2ABDT-TE116C0 - JIANGSU SHUANGSHUANG TECHNOLOGY CO,LTD.
2ABDT-TE116C0

MID

Oct 29, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
tablet PC - FCC ID 2ABDT-TQ10A11 - JIANGSU SHUANGSHUANG TECHNOLOGY CO,LTD.
2ABDT-TQ10A11

tablet PC

Jun 09, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
MID - FCC ID 2ABDT-TE82C2 - JIANGSU SHUANGSHUANG TECHNOLOGY CO,LTD.
2ABDT-TE82C2

MID

May 29, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
MID - FCC ID 2ABDT-TQ10A10 - JIANGSU SHUANGSHUANG TECHNOLOGY CO,LTD.
2ABDT-TQ10A10

MID

Nov 02, 2014

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
MID - FCC ID 2ABDT-TQ82C1 - JIANGSU SHUANGSHUANG TECHNOLOGY CO,LTD.
2ABDT-TQ82C1

MID

Jul 17, 2014

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter