FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Mircom Group of Companies/
  3. 2ABFD-NC-103

2ABFD-NC-103NC-103 MiCare Pull Station

Mircom Group of Companies
NC-103 MiCare Pull Station - FCC ID 2ABFD-NC-103 - Mircom Group of Companies
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 08, 2015
Application Purpose
Original Equipment
Date of Application
Nov 08, 2015
Equipment Note
NC-103 MiCare Pull Station
Frequency Range
2405.00000000 - 2480.00000000
Company
Mircom Group of Companies
Country
Canada

Documents & Files

Select a file to view

Users Manual

โ†—

Cover Letter(s)

โ†—
โ†—

External Photos

โ†—

ID Label/Location Info

โ†—

Internal Photos

โ†—

Test Report

โ†—

Test Setup Photos

โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Nurse Call System LT-2076 Rev. 1 .2 September 2015 User Guide For the latest compatability information visit www.mircom.com/deviceguide LT-2076 Rev 1.23 Table of Contents 1.0Introduction 5 1.1About this User Guide .................................................................................................... 5 1.2Contact Us ..................................................................................................................... 6 1.2.1General Inquiries ............................................................................................................ 6 1.2.2Customer Service .......................................................................................................... 6 1.2.4Website .......................................................................................................................... 6 2.0Dashboard 7 2.1Campus, Building, Wing, and Floor ............................................................................... 7 2.2Alerts .............................................................................................................................. 8 2.3Alerts List ....................................................................................................................... 8 2.3.1Speaking to the patient .................................................................................................. 8 2.4Activity ............................................................................................................................ 9 3.0Manage My Shift 10 3.1Logging in to Dashboard ................................................................................................ 10 3.2Starting your Shift .......................................................................................................... 10 3.3Recording Breaks .......................................................................................................... 10 3.4Ending your Shift ............................................................................................................ 10 4.0Patients and Attendants 11 4.1Patients .......................................................................................................................... 11 4.1.1Check Ins ....................................................................................................................... 11 4.2Attendants ...................................................................................................................... 11 5.0Active Alerts 12 6.0Warranty and Warning Information 13 6.1Warning Please Read Carefully ..................................................................................... 13 6.2Note to Installers ............................................................................................................ 13 6.3System Failures ............................................................................................................. 13 6.3.1Inadequate Installation ................................................................................................... 13 6.3.2Power Failure ................................................................................................................. 13 6.3.3Failure of Replaceable Batteries .................................................................................... 13 6.3.4Compromise of Radio Frequency (Wireless) Devices ................................................... 14 6.3.5System Users ................................................................................................................. 14 4LT-2076 Rev 1.2 6.3.6Automatic Alarm Initiating Devices ................................................................................. 14 6.3.7Software ......................................................................................................................... 14 6.3.8Alarm Notification ........................................................................................................... 14 6.3.9Telephone Lines ............................................................................................................. 14 6.3.10Insufficient Time ............................................................................................................. 15 6.3.11Component Failure ......................................................................................................... 15 6.3.12Inadequate Testing ........................................................................................................ 15 6.3.13Security and Insurance .................................................................................................. 15 6.4Limited Warranty ............................................................................................................ 15 6.4.1International Warranty .................................................................................................... 15 6.4.2Conditions to Void Warranty .......................................................................................... 15 6.5Warranty Procedure ....................................................................................................... 16 6.6Disclaimer of Warranties ................................................................................................ 16 6.7Out of Warranty Repairs ................................................................................................ 16 7.0Special Notices 18 7.1Industry Canada Notice .................................................................................................. 18 7.2FCC Notice ..................................................................................................................... 18 LT-2076 Rev 1.25 1.0 Introduction 1.1About this User Guide This user guide describes how attendants use the Dashboard Nursing Station software (Dashboard). With Dashboard, attendants can manage their shifts, get information about patients, find other โ€ฆ

Text truncated - open the document above for the full version.

Test Report

This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Emissions Report for Mircom Technologies Ltd. on the NC-103 Page 1 of 73 EMISSIONS TEST REPORT Report Number: 101930181BOX-001a Project Number: G101930181 Report Issue Date: 02/03/2015 Product Designation: NC-103 (Originally tested as Igeacare 2.4GHz Pull Cord) Standards: CFR47 FCC Part 15 Subpart C 15.247:2015 CFR47 FCC Part 15 Subpart B:2015 IC RSS-247 Issue 1 May 2015 IC RSS-Gen Issue 4 November 2014 IC ICES-003 Issue 5 August 2012 IC RSS-102 Issue 5 March 2015 updated December 2010 Tested by: Client: Intertek Testing Services NA, Inc. 70 Codman Hill Road Boxborough, MA 01719 Mircom Technologies Ltd. 25 Interchange Way Vaughan ON L4K 5W3 Canada Testing was originally performed for IGEACare Solutions Inc. 163 Rivalda Road North York M9M 2M7 Canada As company name and model number changed, output power and spurious emissions was spot checked on 01/10/2015 and found that emissions didnโ€™t get worst. Report prepared by Report reviewed by Vathana F. Ven / Staff Engineer Michael F. Murphy / Sr. Staff Engineer Intertek Report Number: 101930181BOX-001a Issued: 02/03/2015 Emissions Report for Mircom Technologies Ltd. on the NC-103 Page 2 of 73 1 Introduction and Conclusion The tests indicated in section 2.0 were performed on the product constructed as described in section 4.0. The remaining test sections are the verbatim text from the actual data sheets used during the investigation. These test sections include the test name, the specified test Method, a list of the actual Test Equipment Used, documentation Photos, Results and raw Data. No additions, deviations, or exclusions have been made from the standard(s) unless specifically noted. Based on the results of our investigation, we have concluded the product tested complies with the requirements of the standard(s) indicated. The results obtained in this test report pertain only to the item(s) tested. 2 Test Summary Section Test full name Result 3 Client Information -- 4 Description of Equipment Under Test -- 5 System Setup and Method -- 6 RF Output Power, Duty Cycle, and Human RF Exposure ( CFR47 FCC Part 15 Subpart C 15.247(b)(3), KDB 558074, IC RSS-247 Issue 1 May 2015 5.4(4), IC RSS-102 Issue 5 March 2015) Pass 7 6 dB Bandwidth ( CFR47 FCC Part 15 Subpart C 15.247(a)(2), IC RSS-247 Issue 1 May 2015 5.2, IC RSS-Gen Section 6.6, KDB 558074) Pass 8 Peak Power Spectral Density ( FCC 15:2015 Subpart C Section 15.247 (e), RSS-247 Issue 1 May 2015 5.2(2), KDB 558074) Pass 9 Band Edge Compliance ( FCC 15:2015 Subpart C Section 15.247 (d), RSS-247 Issue 1 May 2015 5.2(2), KDB 558074) Pass 10 Transmitter Radiated Spurious Emissions (CFR47 FCC Part 15 Subpart C 15.247(d), IC RSS-247 Issue 1 May 2015 5.5, KDB 558074) Pass 11 Receiver/Digital Device Radiated Spurious Emissions (CFR47 FCC Part 15 Subpart B 15.109, IC RSS-Gen Sections 4.10 & 6.0) Pass - AC Mains Conducted Emissions CFR47 FCC Part 15:2015 Subpart B Section 15.207 IC RSS-Gen Issue 3 December 2010, 7.2.2 (Table 2) N/A, Battery Powered 12 Revision History -- Intertek Report Number: 101930181BOX-001a Issued: 02/03/2015 Emissions Report for Mircom Technologies Ltd. on the NC-103 Page 3 of 73 3 Client Information This EUT was tested at the request of: Company: Mircom Technologies Ltd. 25 Interchange Way Vaughan ON L4K 5W3 Canada Contact: Mr. Mike Mahoney Telephone: (905) 660-4655 Fax: (905) 695-3538 Email: [email protected] 4 Description of Equipment Under Test Equipment Under Test Description Manufacturer Model Number Serial Number MiCare Wireless Pull Station Mircom Technologies Ltd. (was IGEACare Solutions Inc) NC-103 ( Originally tested as Igeacare 2.4GHz Pull Cord) 12 Receive Date: 06/04/2012, 01/10/2015 Start Date: 08/24/2012 Received Condition: Good Complete date: 01/10/2015 Type: Prototype Description of Equipment Under Test (provided by client) The EUT is a transmitter. It runs on 3VDC battery. Equipment Under Test Power Configuration Rated Voltage Rated Current Rated Frequency Number of Phases 3VDC Battery N/A N/A N/A Operating modes of the EUT: No. Descriptions of EUT Exercising 1 Transmit, Channel 11 (2405 MHz), Channel 18 (2440 MHz), Channel 26 (2480 MHz) 2 Receive Intertek Report Number: 101930181BOX-001a Issued: 02/03/2015 Emissions Report for Mircom Technologies Ltd. on the NC-103 Page 4 of 73 5 System Setup and Method Cables ID Description Length (m) Shielding Ferrites Termination None Support Equipment Description Manufacturer Model Number Serial Number None 5.1 Method: Configuration as required by ANSI C63.4:2009, ANSI C63.10:2009, and KDB 558074. 5.2 EUT Block Diagram: Intertek Report Number: 101930181BOX-001a Issued: 02/03/2015 Emissions Report for Mircom Technologies Ltd. on the NC-103 Page 5 of 73 6 Maximum Peak Output Power, Human RF Exposure, and Duty Cycle 6.1 Method Tests are performed in accordance with Tests are performed in accordance with FCC Part 15 Subpart C Section 15.247, KDB 558074, ANSI C63.10, RSS-102, FCC Part 2 and KDB 447498, and RSS-247. TEST SITE: 10m ALSE The 10m ALSE is 13m (Length) x 21m (Depth) x 10m (Height) with the effective size in terms of space โ€ฆ

Text truncated - open the document above for the full version.

Test Setup Photos

Intertek Report Number: 101930181BOX-001a Issued: 02/03/2015 Emissions Report for Mircom Technologies Ltd. on the NC-103 Page 18 of 73 7.4 Setup Photographs: 30-1000 MHz Intertek Report Number: 101930181BOX-001a Issued: 02/03/2015 Emissions Report for Mircom Technologies Ltd. on the NC-103 Page 19 of 73 1-18 GHz (EUT sits flat) Intertek Report Number: 101930181BOX-001a Issued: 02/03/2015 Emissions Report for Mircom Technologies Ltd. on the NC-103 Page 20 of 73 1-18 GHz (EUT sits on its short side) Intertek Report Number: 101930181BOX-001a Issued: 02/03/2015 Emissions Report for Mircom Technologies Ltd. on the NC-103 Page 21 of 73 1-18 GHz (EUT sits on its long side) Intertek Report Number: 101930181BOX-001a Issued: 02/03/2015 Emissions Report for Mircom Technologies Ltd. on the NC-103 Page 22 of 73 18-25 GHz (Hand scan)

Contact Information

Applicant

Laurie E Eisner
[email protected]9056604655Fax: 8886604113

Technical Contact

Mircom Group of CompaniesMike Mahoney
[email protected]19056604655

25 Interchange Way ยท Vaughan ยท Canada

Non-Technical Contact

Mircom Group of CompaniesJason Falbo
[email protected]905-660-4655

Test Firm

Intertek Testing Services NA Inc.Yaqing Liu
[email protected]978 635 8662

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz483.10 ยตW
Confidentiality
Long Term

Other Applications from Mircom Group of Companies

Wireless transceiver module - FCC ID 2ABFD-MDF1019 - Mircom Group of Companies
2ABFD-MDF1019

Wireless transceiver module

May 27, 2021

Equipment Class

DTS - Digital Transmission System
NC-500 MiCare Pendant - FCC ID 2ABFD-NC-500 - Mircom Group of Companies
2ABFD-NC-500

NC-500 MiCare Pendant

Nov 09, 2015

Equipment Class

DTS - Digital Transmission System
NC-220 MiCare ZF3 - FCC ID 2ABFD-NC-220 - Mircom Group of Companies
2ABFD-NC-220

NC-220 MiCare ZF3

Nov 09, 2015

Equipment Class

DTS - Digital Transmission System
NC-2000 MiCare Patient Unit - FCC ID 2ABFD-NC-2000 - Mircom Group of Companies
2ABFD-NC-2000

NC-2000 MiCare Patient Unit

Nov 09, 2015

Equipment Class

DTS - Digital Transmission System
NC-210 MiCare Beacon - FCC ID 2ABFD-NC-210 - Mircom Group of Companies
2ABFD-NC-210

NC-210 MiCare Beacon

Nov 09, 2015

Equipment Class

DTS - Digital Transmission System