FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. The Watt Stopper Inc., d/b/a Qmotion/
  3. 2ABLX-150404Z

2ABLX-150404ZIntelligent repeater for the extension of IEEE 802.15.4 networks

The Watt Stopper Inc., d/b/a Qmotion
Intelligent repeater for the extension of IEEE 802.15.4 networks - FCC ID 2ABLX-150404Z - The Watt Stopper Inc., d/b/a Qmotion
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 22, 2015
Application Purpose
Original Equipment
Date of Application
Sep 22, 2015
Equipment Note
Intelligent repeater for the extension of IEEE 802.15.4 networks
Frequency Range
2405.00000000 - 2475.00000000
Company
The Watt Stopper Inc., d/b/a Qmotion
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Step 1 Open the coordinator hub for joining or pairing the remote and the shade. - If you already have a coordinator/ router check manufacturers instruction on how to place into pairing mode - If using QMotion Router push pairing button on side and let go Step 2 Slightly tug the shade 6” to wake shade up. The shade will try to join the network by moving up and down (jogging). Will be in learn mode for 2 minutes. Step 3 Press any button on the remote to join the network. Step 4 Shade is now connected to network. LED on remote will flash letting you know if connected. Step 5 Learn shade to remote. Hit “MODE SELECT” button on the back of remote. Then you will hit “UP” button. Shade will then move to 75% position. Step 6 Tug the shade 6” and let go. Shade is now learned to the remote. Step 7 To learn bottom limit, hold “DOWN” button for five seconds. Shade will jog. Step 8 T ug shade to enter learn mode. Step 9 Pull shade to desired bottom limit. Step 10 Hold “DOWN” button for five seconds to store posi- tion. Shade will jog to confirm learned bottom limit. Step 11 Hit “DOWN” button to confirm bottom limit. Step 12 Hit “UP” button to open shade. Shade will travel to full open position. You now have bottom limit and intermediate positions learned. NETWORK SETUP AND INSTALLATION INSTRUCTIONS UNIVERSAL REMOTE (MODEL #QZR-ZIG2400), CRYSTAL CONNECT (MODEL #QMRS-240Z), & QMotion Router (MODEL # 150404Z) Channel Button Variable Position Butttons Channel/Mode Reverse Side Mode Select Button Pairing the remote to the QMotion Router allows for communications to your shades Universal Remote QMotion Router Crystal Connect Roller Shade Up/Down Buttons IMPORTANT Read and understand all instructions before installing. Always wear personal protection equipment including safety glasses and gloves. Use a ladder per its manufacturer’s instructions. Work safely! FCC Warning: Changes or modifications to this device not expressly approved by QMotion Advanced Shading Systems could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital de- vice, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protec- tion against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that inter- ference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is con- nected. • Consult the dealer or an experienced radio/TV technician for help. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environ- ment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. INDUSTRY CANADA Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce po- tential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful com- munication. Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Indus- trie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une communication satisfaisante. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.

Cover Letter(s)

Federal Communications Commission Date: 9-16-15 P.O. Box 429 Columbia, MD 21045 Gentlemen: By signature below, we hereby appoint US Tech employees Sandi McEnery, Alan Ghasiani and George Yang to act as our agents with regard to all FCC equipment authorizations. This appointment will remain in effect until otherwise notified. I further certify by signature below that no party (per 47 CFR 1.2002(b)) to the application is subject to a denial of Federal benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). This appointment includes the authority to complete FCC Form 731 on our behalf and sign the application as an authorized agent. Sincerely, David Ayer RF Design Engineer Date: 9-16-15

Cover Letter(s)

Request for Confidentiality Date: ___September 18, 2015_____ Subject: Confidentiality Request for: ___FCC ID: 2ABLX-150404Z IC: 8832A-150404Z_ Pursuant to FCC 47 CRF 0.457(d) and 0.459 and IC RSP-100, Section 10, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term External Photos Short Term Internal Photos Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Parts List & Placement/BOM Short Term Permanent Tune-Up Procedure Short Term Permanent Schematics Short Term Test Setup Photos Short Term User’s Manual QMotion Incorporated has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. NOTE for Industry Canada Applications: The applicant understands that until such time that IC distinguishes between Short Term and Permanent Confidentiality, either type of marked exhibit above will simply be marked Confidential when submitted to IC. Sincerely, By: __________________________ ___Sandi McEnery__- Agent (Signature/Title 1 ) (Print name)

External Photos

US Tech Test Report: FCC Part 15 Certification/ RSS 247 FCC ID: 2ABLX-150404Z IC: 8832A-150404Z Test Report Number: 15-0218 Issue Date: September 4, 2015 Customer: Qmotion Incorporated Model: 150404Z Page 1 of 6 EXTERNAL PHOTOGRAPHS Figure 1. Top of EUT US Tech Test Report: FCC Part 15 Certification/ RSS 247 FCC ID: 2ABLX-150404Z IC: 8832A-150404Z Test Report Number: 15-0218 Issue Date: September 4, 2015 Customer: Qmotion Incorporated Model: 150404Z Page 2 of 6 Figure 2. Bottom of EUT US Tech Test Report: FCC Part 15 Certification/ RSS 247 FCC ID: 2ABLX-150404Z IC: 8832A-150404Z Test Report Number: 15-0218 Issue Date: September 4, 2015 Customer: Qmotion Incorporated Model: 150404Z Page 3 of 6 Figure 3. Left Side of EUT US Tech Test Report: FCC Part 15 Certification/ RSS 247 FCC ID: 2ABLX-150404Z IC: 8832A-150404Z Test Report Number: 15-0218 Issue Date: September 4, 2015 Customer: Qmotion Incorporated Model: 150404Z Page 4 of 6 Figure 4. Right Side of EUT US Tech Test Report: FCC Part 15 Certification/ RSS 247 FCC ID: 2ABLX-150404Z IC: 8832A-150404Z Test Report Number: 15-0218 Issue Date: September 4, 2015 Customer: Qmotion Incorporated Model: 150404Z Page 5 of 6 Figure 5. Front of EUT US Tech Test Report: FCC Part 15 Certification/ RSS 247 FCC ID: 2ABLX-150404Z IC: 8832A-150404Z Test Report Number: 15-0218 Issue Date: September 4, 2015 Customer: Qmotion Incorporated Model: 150404Z Page 6 of 6 Figure 6. Back of EUT

ID Label/Location Info

US Tech Test Report: FCC Part 15 Certification/ RSS 247 FCC ID: 2ABLX-150404Z IC: 8832A-150404Z Test Report Number: 15-0218 Issue Date: September 4, 2015 Customer: Qmotion Incorporated Model: 150404Z Page 1 of 2 SAMPLE LABEL (location is shown on following page) US Tech Test Report: FCC Part 15 Certification/ RSS 247 FCC ID: 2ABLX-150404Z IC: 8832A-150404Z Test Report Number: 15-0218 Issue Date: September 4, 2015 Customer: Qmotion Incorporated Model: 150404Z Page 2 of 2 Label Location

Internal Photos

US Tech Test Report: FCC Part 15 Certification/ RSS 247 FCC ID: 2ABLX-150404Z IC: 8832A-150404Z Test Report Number: 15-0218 Issue Date: September 4, 2015 Customer: Qmotion Incorporated Model: 150404Z Page 1 of 2 INTERNAL PHOTOGRAPHS Figure 1. Top of PCB (with Antenna) US Tech Test Report: FCC Part 15 Certification/ RSS 247 FCC ID: 2ABLX-150404Z IC: 8832A-150404Z Test Report Number: 15-0218 Issue Date: September 4, 2015 Customer: Qmotion Incorporated Model: 150404Z Page 2 of 2 Figure 2. Bottom of PCB

RF Exposure Info

US Tech Test Report: FCC Part 15 Certification/ RSS 247 FCC ID: 2ABLX-150404Z IC: 8832A-150404Z Test Report Number: 15-0218 Issue Date: September 4, 2015 Customer: Qmotion Incorporated Model: 150404Z Page 1 of 1 MPE and SAR Threshold Requirements Highest Gain Antenna (Trace Antenna) = 3.3 dBi Peak Power (dBm)= 20.5 (highest measured output power level) Gain of Transmit Antenna = 3.3 dBi Distance = 190 mm time based average= Duty Cycle = 66% Total source based time average= (Pwr dBm) + (Ant gain dBi) * time based average 20.5 dBm + 3.3 dBi = 23.5 dBm (223.9 mW) * 0.66 = 147.8 mW which is << less than 1496 mW for FCC @ 190 mm which is << less than 309 mW for IC @ > 50 mm

Test Report

Page 1 of 53 Application For Part 2, Subpart J, Paragraph 2.907 Equipment Authorization of Certification for an Intentional Radiator per Part 15, Subpart C, paragraphs 15.207, 15.209 and 15.247 And RSS-247 Issue 1 For Industry Canada For the QMotion Incorporated Model: 150404Z QMotion Router FCC ID: 2ABLX-150404Z IC: 8832A-150404Z UST Project: 15-0218 Issue Date: September 4, 2015 Total Pages in This Report: 53 3505 Francis Circle Alpharetta, GA 30004 PH: 770-740-0717 Fax: 770-740-1508 www.ustech-lab.com Page 2 of 53 I certify that I am authorized to sign for the Test Agency and that all of the statements in this report and in the Exhibits attached hereto are true and correct to the best of my knowledge and belief: US TECH (Agent Responsible For Test): By: Alan Ghasiani Name: Title: Compliance Engineer – President Date September 4, 2015 This report shall not be reproduced except in full. This report may be copied in part only with the prior written approval of US Tech. The results contained in this report are subject to the adequacy and representative character of the sample provided. This report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the Federal Government. 3505 Francis Circle Alpharetta, GA 30004 PH: 770-740-0717 Fax: 770-740-1508 www.ustech-lab.com US Tech Test Report: FCC Part 15 Certification/ RSS 247 FCC ID: 2ABLX-150404Z IC: 8832A-150404Z Test Report Number: 15-0218 Issue Date: September 4, 2015 Customer: QMotion Incorporated Model: 150404Z Page 3 of 53 MEASUREMENT TECHNICAL REPORT COMPANY NAME: QMotion Incorporated MODEL: 150404Z FCC ID: 2ABLX-150404Z IC: 8832A-150404Z DATE: September 4, 2015 This report concerns (check one): Original grant X Class II change Equipment type: 2405-2475 MHz Transmitter Module Deferred grant requested per 47 CFR 0.457(d)(1)(ii)? yes_____ No X If yes, defer until: ______N/A___________ date agrees to notify the Commission by N/A date of the intended date of announcement of the product so that the grant can be issued on that date. Report prepared by: US Tech 3505 Francis Circle Alpharetta, GA 30004 Phone Number: (770) 740-0717 Fax Number: (770) 740-1508 US Tech Test Report: FCC Part 15 Certification/ RSS 247 FCC ID: 2ABLX-150404Z IC: 8832A-150404Z Test Report Number: 15-0218 Issue Date: September 4, 2015 Customer: QMotion Incorporated Model: 150404Z Page 4 of 53 Table of Contents Paragraph Title Page 1 General Information .............................................................................................. 7 1.1 Purpose of this Report ...................................................................................... 7 1.2 Characterization of Test Sample ...................................................................... 7 1.3 Product Description .......................................................................................... 7 1.4 Configuration of Tested System ....................................................................... 7 1.5 Test Facility ...................................................................................................... 7 1.6 Related Submittals ........................................................................................... 8 2 Tests and Measurements ................................................................................... 10 2.1 Test Equipment .............................................................................................. 10 2.2 Modifications to EUT Hardware ...................................................................... 11 2.3 Number of Measurements for Intentional Radiators (15.31(m)) ..................... 11 2.4 Frequency Range of Radiated Measurements (Part 15.33) ........................... 11 2.4.1 Intentional Radiator .................................................................................. 11 2.4.2 Unintentional Radiator ............................................................................. 12 2.5 Measurement Detector Function and Bandwidth (CFR 15.35) ....................... 12 2.5.1 Detector Function and Associated Bandwidth ......................................... 12 2.5.2 Corresponding Peak and Average Requirements .................................... 12 2.5.3 Pulsed Transmitter Averaging .................................................................. 12 2.6 EUT Antenna Requirements (CFR 15.203) .................................................... 13 2.7 Restricted Bands of Operation (Part 15.205).................................................. 14 2.8 Transmitter Duty Cycle (CFR 35 (c)) .............................................................. 14 2.9 Intentional Radiator, Power Line Conducted Emissions (CFR 15.207) .......... 15 2.10 Intentional Radiator, Radiated Emissions (CFR 15.209, 15.247(d)) (IC RSS 247, 5.4) ............................................................................................................... 16 2.11 Band Edge Measurements – (CFR 15.247 (d)) ............................................ 25 2.12 Six (6) dB Bandwidth per CFR 15.247(a)(2) ................................................. 34 2.13 99% Occupied Bandwidth (IC RSS 247 5.7 & 5.2) ....................................... 39 2.14 Maximum Peak Conducted Output Power (CFR 15.247 (b) (3)) .................. 40 2.15 Power Spectral Density (CFR 15.247(e)) (IC RSS 247 5.1 & 5.2) ................ 44 2.16 Unintentional Radiator, Powerline Emissions (CFR 15.107) ........................ 48 2.17 Unintentional Radiator, Radiated Emissions (CFR 15.109) .......................... 50 2.18 Measurement Uncertainty ............................................................................ 53 2.18.1 Conducted Emissions Measurement Uncertainty .................................. 53 2.18.2 Radiated Emissions Measurement Uncertainty ..................................... 53 US Tech Test Report: FCC Part 15 Certification/ RSS 247 FCC ID: 2ABLX-150404Z IC: 8832A-150404Z Test Report Nu…

Text truncated - open the document above for the full version.

Test Setup Photos

US Tech Test Report: FCC Part 15 Certification/ RSS 247 FCC ID: 2ABLX-150404Z IC: 8832A-150404Z Test Report Number: 15-0218 Issue Date: September 4, 2015 Customer: Qmotion Incorporated Model: 150404Z Page 1 of 7 TEST CONFIGURATION PHOTOGRAPHS Figure 1. Radiated Emissions Test Setup, Front below 1 GHz US Tech Test Report: FCC Part 15 Certification/ RSS 247 FCC ID: 2ABLX-150404Z IC: 8832A-150404Z Test Report Number: 15-0218 Issue Date: September 4, 2015 Customer: Qmotion Incorporated Model: 150404Z Page 2 of 7 Figure 2. Radiated Emissions Test Setup, Front above1 GHz US Tech Test Report: FCC Part 15 Certification/ RSS 247 FCC ID: 2ABLX-150404Z IC: 8832A-150404Z Test Report Number: 15-0218 Issue Date: September 4, 2015 Customer: Qmotion Incorporated Model: 150404Z Page 3 of 7 Figure 3. Radiated Emissions Test Setup, .15 MHz to 300 MHz, Back US Tech Test Report: FCC Part 15 Certification/ RSS 247 FCC ID: 2ABLX-150404Z IC: 8832A-150404Z Test Report Number: 15-0218 Issue Date: September 4, 2015 Customer: Qmotion Incorporated Model: 150404Z Page 4 of 7 Figure 4. Radiated Emissions Test Setup, 30 MHz to 200 MHz, Back US Tech Test Report: FCC Part 15 Certification/ RSS 247 FCC ID: 2ABLX-150404Z IC: 8832A-150404Z Test Report Number: 15-0218 Issue Date: September 4, 2015 Customer: Qmotion Incorporated Model: 150404Z Page 5 of 7 Figure 5. Radiated Emissions Test Setup, 200 MHz to 1GHz, Back US Tech Test Report: FCC Part 15 Certification/ RSS 247 FCC ID: 2ABLX-150404Z IC: 8832A-150404Z Test Report Number: 15-0218 Issue Date: September 4, 2015 Customer: Qmotion Incorporated Model: 150404Z Page 6 of 7 Figure 6. Radiated Emission Test Setup, above 1 GHz, Back EUT US Tech Test Report: FCC Part 15 Certification/ RSS 247 FCC ID: 2ABLX-150404Z IC: 8832A-150404Z Test Report Number: 15-0218 Issue Date: September 4, 2015 Customer: Qmotion Incorporated Model: 150404Z Page 7 of 7 Figure 7. Conducted Emissions Test Setup

Contact Information

Applicant

David Ayer(RF Design Engineer)
[email protected]850-308-7328Fax: 850-208-3404

Test Firm

US TechGeorge Yang
[email protected]770-740-0717Fax: 770-740-1508

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz112.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is maximum combined output power conducted. This device must be installed to provide a separation distance of at least 20 cm from all persons. Users must be provided with device operating conditions for satisfying RF exposure compliance.

Other Applications from The Watt Stopper Inc., d/b/a Qmotion

Zigbee Hardwired Dual Channel Switch - FCC ID 2ABLX-150562Z - The Watt Stopper Inc., d/b/a Qmotion
2ABLX-150562Z

Zigbee Hardwired Dual Channel Switch

Jan 27, 2016

Equipment Class

DTS - Digital Transmission System
Zigbee Hardwired Single Channel Switch - FCC ID 2ABLX-150560Z - The Watt Stopper Inc., d/b/a Qmotion
2ABLX-150560Z

Zigbee Hardwired Single Channel Switch

Jan 27, 2016

Equipment Class

DTS - Digital Transmission System
Zigbee Hardwired Roller - FCC ID 2ABLX-150017 - The Watt Stopper Inc., d/b/a Qmotion
2ABLX-150017

Zigbee Hardwired Roller

Jan 27, 2016

Equipment Class

DTS - Digital Transmission System
QSYNC Transceiver - FCC ID 2ABLX-QSYNC433FM - The Watt Stopper Inc., d/b/a Qmotion
2ABLX-QSYNC433FM

QSYNC Transceiver

Sep 24, 2015

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Zigbee Roller Shade - FCC ID 2ABLX-240Z - The Watt Stopper Inc., d/b/a Qmotion
2ABLX-240Z

Zigbee Roller Shade

Jun 29, 2015

Equipment Class

DTS - Digital Transmission System