FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Apollo America, Inc/
  3. 2ACE9-51000355A

2ACE9-51000355AWireless Smoke Heat Alarm

Apollo America, Inc
Wireless Smoke Heat Alarm - FCC ID 2ACE9-51000355A - Apollo America, Inc
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jan 28, 2015
Application Purpose
Original Equipment
Date of Application
Jan 27, 2015
Equipment Note
Wireless Smoke Heat Alarm
Frequency Range
345.00000000 - 345.00000000
Company
Apollo America, Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Operational Description

Test Report

Test Setup Photos

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Cet appareil est conforme à la partie 15 de la réglementation de la FCC et aux normes RSS sur les appareils exempts de licence d'Industrie Canada. Son fonctionnement est soumis aux deux conditions suivantes : (1) Ce dispositif ne doit pas causer d’interférences nuisibles, et (2) cet appareil doit accepter toute interférence reçue, y compris les interférences pouvant causer un fonctionnement inopiné de l’appareil. Cet équipement a été testé et déclaré conforme aux limites applicables aux périphériques numériques de classe B, selon la partie 15 de la réglementation de la FCC. Ces limites ont été conçues pour fournir une protection raisonnable contre les interférences nuisibles en milieu résidentiel. Cet équipement produit, utilise et peut émettre de l’énergie de fréquence radio. Si l’équipement n’est pas installé et utilisé conformément aux instructions fournies, il peut provoquer des interférences néfastes aux communications radio. Cependant, la possibilité qu'une interférence se produise dans une installation particulière n’est pas totalement exclue. Si cet équipement ne produit pas d'interférences nuisibles à la réception radio ou télévision, ce qui peut être déterminé en éteignant et en rallumant l’équipement, il est recommandé à l’utilisateur d'essayer de remédier aux interférences en appliquant l’une ou plusieurs des mesures suivantes : • Réorientez ou déplacez l’antenne de réception. • Augmentez la distance qui sépare l’équipement du récepteur • Branchez l’équipement à une prise située sur un circuit différent de celui auquel le récepteur est connecté. • Consultez le revendeur ou un technicien radio/TV expérimenté pour obtenir de l’aide « Pour votre information, la norme NFPA 72 du code national d’alarme incendie stipule que : « Détection requise 11.5.1 » « Lorsque cela est requis par les lois, des codes ou normes applicables pour un type spécifi que d’habitation, les détecteurs de fumée simples et multipostes approuvés seront installés de la manière suivante : 1. Dans les chambres à coucher et chambres d'amis 2. À l’extérieur de chaque chambre à coucher d'une maison d'habitation, à 6,4 m (21 pieds) de toute porte donnant sur une chambre à coucher, la distance étant mesurée le long d’un chemin de circulation 3. À chaque niveau d’une maison d’habitation, y compris les sous-sols 4. À chaque niveau d’un foyer résidentiel et d'un établissement de soins (petit établissement), y compris les sous-sols et excepté les vides sanitaires et les combles inachevés 5. Dans la salle de séjour d'une suite d'amis 6. Dans la salle de séjour d’un foyer résidentiel et d'un établissement de soins. (Réimprimé avec la permission de la norme NFPA 72®, du code national d’alarme incendie Copyright © 2007 National Fire Protection Association, Quincy, MA 02269. Cette réimpression n’exprime pas la position complète et offi cielle de la National Fire Protection Association sur le sujet cité qui est représenté uniquement par la norme dans son intégralité.) (Code national d’alarme incendie® et NFPA 72 ® sont des marques déposées de la National Fire Protection Association, Inc., Quincy, MA 02269.) Dans les maisons d'habitation à niveau unique et à plusieurs niveaux ainsi que dans les immeubles d'habitation équipés de systèmes de détecteurs de fumée similaires, il est possible que les signaux envoyés par des capteurs sans fi l soient bloqués ou réfl échis par le métal avant d'atteindre le panneau de commande du détecteur et ce, même si le parcours du signal a été récemment vérifi é au cours d'un test hebdomadaire. Un blocage peut se produire si un objet métallique a été déplacé dans le parcours du signal du capteur. Apollo America 25 Corporate Drive Auburn Hills, MI 48326 248-332-3900 Phone 888-332-2241 Tech Support www.apollo-fi re.com ATTENTION: This manual should be read prior to use and retained for further information. GENERAL INFORMATION The Wireless Smoke Heat Alarm is a 3xAAA battery powered wireless detector intended for use with a compatible wireless alarm system. The detector has a built-in wireless transmitter, which communicates with the control panel. When smoke is detected, the alarm sounds a loud local alarm and the built-in transmitter sends a signal to the control panel. The Wireless Smoke Heat Alarm contains an integrated fi xed 41°F temperature freeze sensor that will send a warning signal based on temperature detected. This detector is designed to provide protection with 70-foot spacing capability. The detector can send alarm, tamper and battery condition messages to the system’s receiver. Refer to the wireless system’s instruction for the maximum number of transmitters that can be supported. CONTENTS OF BOX: • Wireless Smoke Heat Alarm with base • Installation guide (APD0601) • Pack of screws and anchors • Labels or decals as appropriate • 3 AAA PC2400 Duracell Procell batteries (1.5V 1100mAh) or 3 AAA Energizer E92 batteries (1.5V 1100mAh) The Wireless Smoke Heat Alarm contains a sounder which generates the ANSI S3.41 temporal 3 pattern in an alarm condition. In alarm, a message is also sent to the control panel and the detector’s ID is displayed at the console. During an alarm condition, pressing the detector’s hush button will silence the sounder (see table below). The mounting base installation is simplifi ed by the incorporation of features compatible for both drywall fasteners (not supplied) and other methods. Tricolored LED (red, yellow, green) and a sounder on the detector provide local visual and audible indication of the detector’s status as listed in Table 1. During initial power-up the LED blinks alternately red, yellow then green. It takes about 8 seconds for the detector to stabilize. After power-up has completed and the detector is functioning normally, the green LED blinks once every 12 seconds. Detector Trouble: When the detector has a general fault, the yellow LED blinks once every four seconds and there is a chirp every 48 seconds. After 12 hours the panel will display a loss …

Text truncated - open the document above for the full version.

Cover Letter(s)

The University of Michigan Radiation Laboratory 3228 EECS Building Ann Arbor, Michigan 48109-2122 USA Tel: (734) 483-4211 Fax: (734) 647-2106 e-mail: [email protected] Attn.:Certification and Engineering Bureau Industry Canada 3701 Carling Avenue, Bldg. 94 Ottawa, Ontario K2H 8S2 Current Variants: There is only a single variant of the EUT, as tested. If there are any questions regarding the application or testing performed, please contact us at the above address or call (734) 483-4211, or e-mail [email protected]. Sincerely, Valdis V. Liepa The University of Michigan Radiation Laboratory 12 Re: Certification for Apollo America, Inc. 51000-355 IC: 12011A-51000355A Please find enclosed application materials for certification of Apollo America, Inc. 51000-355. We tested it and found it to comply with IC RSS-210/GENe. The University of Michigan Radiation Laboratory 3228 EECS Building Ann Arbor, Michigan 48109-2122 USA Tel: (734) 483-4211 Fax: (734) 647-2106 e-mail: [email protected] Attn.:Federal Communications Commission Equipment Approval Services P.O. Box 358315 Pittsburgh, PA 15251-5315 If there are any questions regarding the application or testing performed, please contact us at the above address or call (734) 483-4211, or e-mail [email protected]. Sincerely, Valdis V. Liepa The University of Michigan Radiation Laboratory 11 Re: Certification for Apollo America, Inc. 51000-355 FCC ID: 2ACE9-51000355A Please find enclosed application materials for certification of Apollo America, Inc. 51000-355. We tested it and found it to comply with CFR Title 47, Part 15.231.

ID Label/Location Info

Apollo America, Inc. 25 Corporate DriveTel: +1 (248) 332-3900Email:[email protected] Auburn Hills, MI 48326 USA Fax: +1 (248) 332-8807Web: www.apollo-fire.com To whom it may concern, In regards to the labeling requirements found in CFR 47, Part 15.19, the project being filed with the FCC does not have sufficient room, due to the safety marking requirements of UL 217, CAN/ULC-S531, UL 2034, and CAN/CSA-6.19. A nearly identical filing has been performed in the past under Apollo Fire Detectors, LTD. FCC ID numbersZFH-CO3345 and ZFH-SMKT3345. I believe that the subpart (5) of part 15.19 (See excerpt below) was used with the original filing: (5) When the device is so small or for such use that it is not practicable to place the statement specified under paragraph (a) of this section on it, the information required by this paragraph shall be placed in a prominent location in the instruction manual or pamphlet supplied to the user or, alternatively, shall be placed on the container in which the device is marketed. However, the FCC identifier or the unique identifier, as appropriate, must be displayed on the device. If you have any other questionsor concerns regarding this, or any other matter, please do not hesitate in contacting me. Best regards, John Schertel Conformance Manager

Contact Information

Applicant

Andrew Frost(Vice President Engineering)
[email protected]2483323900Fax: 2483328807

Technical Contact

The University of Michigan Radiation LaboratoryValdis V. Liepa
[email protected]7344834211

3228 EECS Building · Ann Arbor, Michigan · United States

Test Firm

University of MichiganValdis Liepa
[email protected]734-647-1792Fax: 734-647-2106

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231345 MHz - 345 MHz-
Confidentiality
Long Term

Other Applications from Apollo America, Inc

Wireless Combination Smoke/CO Detector - FCC ID 2ACE9-5100060X - Apollo America, Inc
2ACE9-5100060X

Wireless Combination Smoke/CO Detector

Dec 02, 2020

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Wireless Carbon Monoxide Alarm - FCC ID 2ACE9-51000307 - Apollo America, Inc
2ACE9-51000307

Wireless Carbon Monoxide Alarm

Jan 25, 2015

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Wireless Smoke Heat Alarm - FCC ID 2ACE9-51000357 - Apollo America, Inc
2ACE9-51000357

Wireless Smoke Heat Alarm

Jan 25, 2015

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Wireless Smoke and Carbon Monoxide Alarm - FCC ID 2ACE9-51000305A - Apollo America, Inc
2ACE9-51000305A

Wireless Smoke and Carbon Monoxide Alarm

Jan 21, 2015

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Wireless Smoke and Heat Alarm - FCC ID 2ACE9-51000355 - Apollo America, Inc
2ACE9-51000355

Wireless Smoke and Heat Alarm

Aug 19, 2014

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter