FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Ideal Industries Lighting LLC, DBA CREE Lighting/
  3. 2ACQ6-CIF

2ACQ6-CIFRelay Module

Ideal Industries Lighting LLC, DBA CREE Lighting
Relay Module - FCC ID 2ACQ6-CIF - Ideal Industries Lighting LLC, DBA CREE Lighting
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 20, 2014
Application Purpose
Original Equipment
Date of Application
Aug 20, 2014
Equipment Note
Relay Module
Frequency Range
2405.00000000 - 2480.00000000
Company
Ideal Industries Lighting LLC, DBA CREE Lighting
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

INSTALLATION INSTRUCTIONS 0-10V Interface Wireless 0-10V Dimming/Switching Interface with SmartCast™ Technology Includes: CIF-10V-CWC-SNSR LPN00212X0005A3_B 1 of 3 IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. Before installing turn off the power at the circuit breaker. 2. Must be installed in accordance with the national and local building codes and electrical wiring codes including wiring methods and wiring connections. If you are not familiar with these codes and requirements, consult a qualified electrician. 3. Indoor use only and suitable for damp locations. 4. Any changes or modifications to these devices not explicitly approved by manufacturer could void your authority to operate this equipment. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE • Voltage: 120-277V, 60Hz • Load Type: 120-277VAC 5-2.1A 600W MAX. (Electric Ballast/ General Purpose (LED)) • Install using a junction box that has a 1/2" knockout UNIT DESCRIPTION The Cree Wireless 0-10V Interface is used to wirelessly control LED luminaires that do not have built in Cree SmartCast ™ Technology. The Cree Wireless 0-10V Interface provides on, off, and 0-10V dimming control. LOAD TYPES 0-10V dimmable loads (IEC60929) INSTALLATION NOTE: For ease of installation, Cree recommends using a Junction Box with a ½" knockout. STEP 1: Disconnect power to circuit by turning circuit breaker OFF before installation. STEP 2: Remove Junction Box cover. STEP 3: Remove knockout and firmly install plastic relay box into Junction Box until it snaps and is securely attached STEP 4: Strip existing Junction Box wires ½". STEP 5: Make wiring connection per the Electrical Connection section. STEP 6: Attach Junction Box cover. STEP 7: Install sensor into ceiling by drilling a 2" hole into the ceiling. 1 Blue LED is Inside the Relay Box, Light will Shine Through at the LED Placement Shown Below. Test/Reset Button Inside Blue LED Placement This End Insert into Junction Box Sensor Interface Box LPN00212X0005A3_B 2 of 3 STEP 8: Unscrew the small trim ring near the sensor and place sensor assembly through the ceiling. See Figure 2. STEP 9: Secure the sensor assembly by screwing the small trim ring removed in Step 8 back onto the sensor assembly. Tighten the larger trim ring above the ceiling until it is snugged tight against the ceiling. See Figure 2. STEP 10: Switch the circuit breaker ON. STEP 11: The blue LED should repeat a two blink sequence. If the blue LED does not respond with the two-blink sequence, please follow the RESET instructions to return the 0-10V Interface to factory defaults. STEP 12: Verify the LOAD wiring with the following TEST instructions: • Press and hold the Test/Reset button for 5 sec then release. The blue LED should respond with a five-blink sequence. Once test mode has been entered, LOAD enters State 1. See Figure 1. • Press and hold Test/Reset button for 1 sec then release to transition to the next state. The sequence repeats after State 3. Please refer to the load table below for your load type. • To exit test mode at any time, press and hold the Test/ Reset button for 5 sec then release. The five-blink sequence ends when test mode is exited. DimmableNon-Dimmable State 1Off Off State 2Max light output (10V)On State 3Min light output (1V)On RESET STEP 1: Press and hold Test/Reset button until the LED flashes fast (approximately 30 seconds). STEP 2: Release the Test/Reset button for 1 second (Fast flashing continues). Press and hold Test/Reset for 1 second until fast flashing stops. If the blue LED does not respond with the two-blink sequence, please repeat the RESET procedure. TROUBLESHOOTING: Out of the box, if the LOAD does not turn on when power is applied: Perform TEST mode to verify proper functionality of the load type • If TEST mode fails, check Wiring with power off. • If wired correctly, check to see if Blue LED is blinking. • If Blue LED is blinking, then perform a RESET (See RESET section). • If Blue LED is on solid or off, call Cree Customer Service. • If you have done a RESET, and the LOAD is still off, call Cree Customer Service. If LOAD is unresponsive use Cree Configuration Tool to verify configuration. 2 Sensor Large Trim Ring Small Trim Ring Ceiling LPN00212X0005A3_B 3 of 3 www.cree.com/lighting © 2013 Cree, Inc. All rights reserved. For informational purposes only. Content is subject to change. See www.cree.com/lighting/products/warranty for warranty and specifications. Cree® and the Cree logo are registered trademarks, and SmartCast™ is a trademark of Cree, Inc. ELECTRICAL CONNECTIONS STEP 1: Make the following Electrical Connections: a. Connect the black Wireless 0-10V Interface lead to the voltage supply position. b. Connect the white Wireless 0-10V Interface lead to the neutral supply position. c. Connect the red Wireless 0-10V Interface lead to the load supply position. d. Connect the green Wireless 0-10V Interface lead to the green wire position of the junction box. For Dimming make the following connections to the customer supplied load: e. Connect the violet Wireless 0-10V Interface lead to the +10V dimming wire of the load. f. Connect the grey Wireless 0-10V Interface lead to the dimming common wire of the load. LINE GREEN LINE-BLACK GROUND-GREEN NEUTRAL-WHITE NEUTRAL SUPPLY WIRING 0-10V INTERFACE JUNCTION BOX LOAD-RED LOAD FCC NOTICE This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the device. This device has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rul…

Text truncated - open the document above for the full version.

Cover Letter(s)

9201 Washington Avenue, Racine, WI 53406 USA Main: (262) 886-1900 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Rd. Columbia, MD 21046 Fax: (310) 344-2050 Reference FCC ID: 2ACQ6-CIF Organization: Cree Inc. Subject: Request under 47 CFR 0.457 and 0.459 that materials submitted to the commission be withheld from public inspection. Cree Inc. hereby requests that the materials attached here to be withheld from public inspection in accordance with 47 CFR 47 0.457 and 0.459. Specifically, Cree Inc. requests that the following materials be withheld from public inspection under 47 CFR 0.457 and 0.459 because the schematics and designs are considered confidential trade secrets and technical data which customarily would be guarded from competitors: Schematic Diagram Block Diagram Theory of Operation Therefore, in accordance with CFR 47 0.457 and 0.459, Cree Inc. requests that the above listed materials, copies of which are here, to be withheld from public inspection. Authorized Signature: Date: May 6, 2014 Daniel J. Guillien Compliance Manager Cree, Inc.

Cover Letter(s)

9201 Washington Avenue, Racine, WI 53406 USA Main: (262) 886-1900 May 6,2014 UL LLC Certification Division 47173 Benicia Street Fremont, CA 94538, USA To whom it may concern: I, the undersigned, hereby authorize UL LLC to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by UL LLC on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). [Remove this section if Regulatory Authority is not FCC] In authorizing UL LLC as our agent, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; h) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; i) keep a record of all complaints made known to the us relating to the product’s compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested; j) take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; k) document the actions taken. This authorization is valid until further written notice from the applicant. Sincerely Yours, Daniel J. Guillien, Compliance Manager Cree, Inc. REMARK: 1. This authorization letter will be sent along with your application when filing with the Certification Division. 2. Please follow the format and type it on company letterhead and send original to us. 3. Authorized signature must be in agreement with grantee code contact in FCC database.

Cover Letter(s)

9201 Washington Avenue, Racine, WI 53406 USA Main: (262) 886-1900 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Rd. Columbia, MD 21046 Fax: (310) 344-2050 Reference FCC ID: 2ACQ6-CIF Organization: CREE INC. Subject: Model Number Declaration To Whom It May Concern: The Relay module, p/n CIF-10VC1-CWC-SNSR is constructed to route the control wires and power wires out of one opening. The Relay module p/n CIF-10V-CWC-SNSR is constructed to route the control wires out of an opening next to the RJ11 port. The power wires are routed through the same opening as the CIF- 10VC1-CWC-SNSR. The power and control wiring are not routed near the radio circuit and are strictly in the area of the unintentional circuitry. There are no differences in the RF Characteristics for p/n CIF-10VC1-CWC-SNSR and p/n CIF-10V-CWC-SNSR. The Relay module p/n CIF-10V-CWC-SNSR was the unit used for testing. Authorized Signature: Date: 2014/05/06 Dan Guillien Compliance Manager Cree, Inc.

External Photos

EXTERNAL PHOTOS FCC ID: 2ACQ6-CIF IC: 11481A-CIF Page 1 of 3 UL LLC 12 LABORATORY DR., RESEARCH TRIANGLE PARK, NC 27709 TEL: (919) 549-1400 RELAY MODULE - EXTERNAL PHOTOS MODEL NUMBER: CIF-10V-CWC-SNSR, CIF-10VC1-CWC-SNSR FCC ID: 2ACQ6-CIF IC: 11481A-CIF Top Side (CIF-10V-CWC-SNSR) EXTERNAL PHOTOS FCC ID: 2ACQ6-CIF IC: 11481A-CIF Page 2 of 3 UL LLC 12 LABORATORY DR., RESEARCH TRIANGLE PARK, NC 27709 TEL: (919) 549-1400 Bottom Side (CIF-10V-CWC-SNSR) EXTERNAL PHOTOS FCC ID: 2ACQ6-CIF IC: 11481A-CIF Page 3 of 3 UL LLC 12 LABORATORY DR., RESEARCH TRIANGLE PARK, NC 27709 TEL: (919) 549-1400 CIF-10VC1-CWC-SNSR

ID Label/Location Info

LABEL AND LABEL PLACEMENT FCC ID: 2ACQ6-CIF IC: 11481A-CIF Page 1 of 1 UL LLC 12 LABORATORY DR., RESEARCH TRIANGLE PARK, NC 27709 TEL: (919) 549-1400 P/N CIF-10V-CWC-SNSR and CIF-10VC1-CWC-SNSR Label Placement Label with the FCC ID

Internal Photos

INTERNAL PHOTOS FCC ID: 2ACQ6-CIF IC: 11481A-CIF Page 1 of 6 UL LLC 12 LABORATORY DR., RESEARCH TRIANGLE PARK, NC 27709 TEL: (919) 549-1400 RELAY MODULE - INTERNAL PHOTOS MODEL NUMBER: CIF-10V-CWC-SNSR, CIF-10VC1-CWC-SNSR FCC ID: 2ACQ6-CIF IC: 11481A-CIF Top Side of Relay Board In Enclosure (CIF-10V-CWC-SNSR) INTERNAL PHOTOS FCC ID: 2ACQ6-CIF IC: 11481A-CIF Page 2 of 6 UL LLC 12 LABORATORY DR., RESEARCH TRIANGLE PARK, NC 27709 TEL: (919) 549-1400 Top Side of Relay Board, Zoomed In (CIF-10V-CWC-SNSR) INTERNAL PHOTOS FCC ID: 2ACQ6-CIF IC: 11481A-CIF Page 3 of 6 UL LLC 12 LABORATORY DR., RESEARCH TRIANGLE PARK, NC 27709 TEL: (919) 549-1400 Bottom Side of Relay Board, Zoomed In (CIF-10V-CWC-SNSR) INTERNAL PHOTOS FCC ID: 2ACQ6-CIF IC: 11481A-CIF Page 4 of 6 UL LLC 12 LABORATORY DR., RESEARCH TRIANGLE PARK, NC 27709 TEL: (919) 549-1400 Top Side of Relay Board In Enclosure (CIF-10VC1-CWC-SNSR) INTERNAL PHOTOS FCC ID: 2ACQ6-CIF IC: 11481A-CIF Page 5 of 6 UL LLC 12 LABORATORY DR., RESEARCH TRIANGLE PARK, NC 27709 TEL: (919) 549-1400 Top Side of Relay Board, Zoomed In (CIF-10VC1-CWC-SNSR) INTERNAL PHOTOS FCC ID: 2ACQ6-CIF IC: 11481A-CIF Page 6 of 6 UL LLC 12 LABORATORY DR., RESEARCH TRIANGLE PARK, NC 27709 TEL: (919) 549-1400 Bottom Side of Relay Board, Zoomed In (CIF-10V-CWC-SNSR)

RF Exposure Info

NVLAP LAB CODE 200246-0 FCC Part 1 Subpart I FCC Part 2 Subpart J INDUSTRY CANADA RSS 102 ISSUE 3 RF EXPOSURE REPORT FOR Relay Module MODEL NUMBER: CIF-10V-CWC-SNSR, CIF-10VC1-CWC-SNSR FCC ID: 2ACQ6-CIF IC: 11481A-CIF REPORT NUMBER: R10015052-MPE ISSUE DATE: 2014-08-20 Prepared for CREE INC. 4600 SILICON DR. DURHAM, NC 27709 USA Prepared by UL LLC 12 LABORATORY DR. RESEARCH TRIANGLE PARK, NC 27709 USA TEL: (919) 549-1400 REPORT NO: R10015052-MPE DATE: 2014-08-20 FCC ID: 2ACQ6-CIF IC: 11481A-CIF Page 2 of 11 UL LLC FORM NO: CCSUP4701I 12 LABORATORY DR., RESEARCH TRIANGLE PARK, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC Revision History Rev. Issue Date Revisions Revised By -- 2013-11-06 Initial Issue Jeff Moser 1 2014-07-15 Grantee Code Revised (previous one issued in error) Jeff Moser 2 2014-08-20 Revised to include additional part number (CIF- 10VC1-CWC-SNSR) Jeff Moser REPORT NO: R10015052-MPE DATE: 2014-08-20 FCC ID: 2ACQ6-CIF IC: 11481A-CIF Page 3 of 11 UL LLC FORM NO: CCSUP4701I 12 LABORATORY DR., RESEARCH TRIANGLE PARK, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ................................................................................. 4 2. TEST METHODOLOGY ..................................................................................................... 5 3. REFERENCES ................................................................................................................... 5 4. FACILITIES AND ACCREDITATION ................................................................................. 5 5. DESCRIPTION OF EUT ..................................................................................................... 5 6. MAXIMUM PERMISSIBLE RF EXPOSURE ....................................................................... 6 6.1. FCC RULES ................................................................................................................ 6 6.2. IC RULES .................................................................................................................... 7 6.3. EQUATIONS ................................................................................................................ 8 6.4. LIMITS AND IC EXEMPTION .....................................................................................10 7. RF EXPOSURE RESULTS ................................................................................................11 REPORT NO: R10015052-MPE DATE: 2014-08-20 FCC ID: 2ACQ6-CIF IC: 11481A-CIF Page 4 of 11 UL LLC FORM NO: CCSUP4701I 12 LABORATORY DR., RESEARCH TRIANGLE PARK, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC 1. ATTESTATION OF TEST RESULTS COMPANY NAME: CREE INC. 4600 SILICON DR. DURHAM, NC 27709 USA EUT DESCRIPTION: Relay Switch with transceiver module. MODEL: Relay Module, p/n CIF-10V-CWC-SNSR, CIF-10VC1-CWC-SNSR SERIAL NUMBER: None DATE TESTED: 2013-07-09 through 2013-08-30 APPLICABLE STANDARDS STANDARD TEST RESULTS FCC PART 1 SUBPART I & PART 2 SUBPART J Pass INDUSTRY CANADA RSS 102 ISSUE 3 Pass UL LLC calculated the RF Exposure of the above equipment in accordance with the requirements set forth in the above standards, using test results reported in the test report documents referenced below and/or documentation furnished by the applicant. All indications of Pass/Fail in this report are opinions expressed by UL LLC based on interpretations of these calculations. The results show that the equipment is capable of demonstrating compliance with the requirements as documented in this report. Note: The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. This document may not be altered or revised in any way unless done so by UL LLC and all revisions are duly noted in the revisions section. Any alteration of this document not carried out by UL LLC will constitute fraud and shall nullify the document. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any agency of the Federal Government, or any agency of any government. Approved & Released For UL LLC By: Calculated By: Bob DeLisi Jeff Moser EMC Principle Engineer EMC Program Manager REPORT NO: R10015052-MPE DATE: 2014-08-20 FCC ID: 2ACQ6-CIF IC: 11481A-CIF Page 5 of 11 UL LLC FORM NO: CCSUP4701I 12 LABORATORY DR., RESEARCH TRIANGLE PARK, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC 2. TEST METHODOLOGY All calculations were made in accordance with FCC OET Bulletin 65 Edition 97-01 and IC Safety Code 6. 3. REFERENCES All measurements were made as documented in test report UL LLC Report R10015052-RF for operation 2.4 GHz band. Output power, Duty cycle and Antenna gain data is excerpted from the applicable test reports. Antenna gain data is excerpted from product documentation provided by the applicant. 4. FACILITIES AND ACCREDITATION The test sites and measurement facilities used to collect data are located at 12 Laboratory Dr., Research Triangle Park, NC 27709, USA. UL LLC (RTP) is accredited by NVLAP, Laboratory Code 200246-0. The full scope of accreditation can be viewed at http://ts.nist.gov/standards/scopes/2002460.htm . 5. DESCRIPTION OF EUT The Relay Modules, p/n CIF-10V-CWC-SNSR and CIF-10VC1-CWC-SNSR are 2.4 GHz DSSS transceivers used with light fixtures. The Relay Module utilizes O-QPSK modulation and a 250 kbps data rate. The Relay Module receives signals from other devices to control the fixture. The radio module is manufactured by Cree Inc. Relay module, p/n CIF-10VC1-CWC-SNSR is constructed to route the control wires and power wires out of one opening. Relay module, p/n CIF-10V-CWC-SNSR…

Text truncated - open the document above for the full version.

Test Report

NVLAP LAB CODE 200246-0 FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 CERTIFICATION TEST REPORT FOR RELAY MODULE MODEL NUMBER: CIF-10V-CWC-SNSR, CIF-10VC1-CWC-SNSR FCC ID: 2ACQ6-CIF IC: 11481A-CIF REPORT NUMBER: R10015052-RF ISSUE DATE: 2014-08-20 Prepared for CREE INC. 4600 SILICON DR. DURHAM, NC 27709 USA Prepared by UL LLC 12 LABORATORY DR. RESEARCH TRIANGLE PARK, NC 27709 USA TEL: (919) 549-1400 REPORT NO: R10015052-RF DATE: 2014-08-20 FCC ID: 2ACQ6-CIF IC: 11481A-CIF Page 2 of 72 UL LLC FORM NO: CCSUP4701I 12 LABORATORY DR., RESEARCH TRIANGLE PARK, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC Revision History Rev. Issue Date Revisions Revised By -- 2013-11-06 Initial Issue Jeff Moser 1 2014-07-15 Grantee Code Revised (previous one issued in error) Jeff Moser 2 2014-08-18 Revised references to KDB 558074 Jeff Moser 3 2014-08-20 Revised to include additional part number (CIF- 10VC1-CWC-SNSR) Jeff Moser REPORT NO: R10015052-RF DATE: 2014-08-20 FCC ID: 2ACQ6-CIF IC: 11481A-CIF Page 3 of 72 UL LLC FORM NO: CCSUP4701I 12 LABORATORY DR., RESEARCH TRIANGLE PARK, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ................................................................................. 4 2. TEST METHODOLOGY ..................................................................................................... 5 3. FACILITIES AND ACCREDITATION ................................................................................. 5 4. CALIBRATION AND UNCERTAINTY ................................................................................ 5 4.1. MEASURING INSTRUMENT CALIBRATION .............................................................. 5 4.2. SAMPLE CALCULATION ............................................................................................ 5 4.3. MEASUREMENT UNCERTAINTY ............................................................................... 5 5. EQUIPMENT UNDER TEST ............................................................................................... 6 5.1. DESCRIPTION OF EUT .............................................................................................. 6 5.2. MAXIMUM OUTPUT POWER...................................................................................... 6 5.3. DESCRIPTION OF AVAILABLE ANTENNAS .............................................................. 6 5.4. SOFTWARE AND FIRMWARE .................................................................................... 7 5.5. WORST-CASE CONFIGURATION AND MODE .......................................................... 8 5.6. DESCRIPTION OF TEST SETUP ................................................................................ 8 6. TEST AND MEASUREMENT EQUIPMENT ......................................................................10 7. ON TIME, DUTY CYCLE AND MEASUREMENT METHODS ...........................................13 7.1. ON TIME AND DUTY CYCLE RESULTS ....................................................................13 7.2. DUTY CYCLE PLOTS ................................................................................................14 8. ANTENNA PORT TEST RESULTS ...................................................................................15 8.1. O-QPSK (DSSS) MODE IN THE 2.4 GHz BAND MODE ............................................15 8.1.1. 6 dB BANDWIDTH ...............................................................................................15 8.1.2. 99% BANDWIDTH ...............................................................................................19 8.1.3. OUTPUT POWER ...............................................................................................23 8.1.4. AVERAGE POWER .............................................................................................27 8.1.5. POWER SPECTRAL DENSITY ...........................................................................28 8.1.6. CONDUCTED SPURIOUS EMISSIONS ..............................................................32 9. RADIATED TEST RESULTS .............................................................................................48 9.1. LIMITS AND PROCEDURE ........................................................................................48 9.2. TRANSMITTER ABOVE 1 GHz ..................................................................................49 9.2.1. TX ABOVE 1 GHz FOR O-QPSK (DSSS) MODE IN THE 2.4 GHz BAND ...........49 9.3. WORST-CASE BELOW 1 GHz ...................................................................................63 10. AC POWER LINE CONDUCTED EMISSIONS ..............................................................67 REPORT NO: R10015052-RF DATE: 2014-08-20 FCC ID: 2ACQ6-CIF IC: 11481A-CIF Page 4 of 72 UL LLC FORM NO: CCSUP4701I 12 LABORATORY DR., RESEARCH TRIANGLE PARK, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC 1. ATTESTATION OF TEST RESULTS COMPANY NAME: CREE INC. 4600 SILICON DR. DURHAM, NC 27709 USA EUT DESCRIPTION: Relay Module with Transceiver MODEL: Relay Module, p/n CIF-10V-CWC-SNSR, CIF-10VC1-CWC-SNSR SERIAL NUMBER: None DATE TESTED: 2013-07-09- 2013-08-30, 2013-10-24 APPLICABLE STANDARDS STANDARD TEST RESULTS CFR 47 Part 15 Subpart C Pass INDUSTRY CANADA RSS-210 Issue 8 Annex 8 Pass INDUSTRY CANADA RSS-GEN Issue 3 Pass UL LLC tested the above equipment in accordance with the requirements set forth in the above standards. All indications of Pass/Fail in this report are opinions expressed by UL LLC based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into account and are published for informational purposes only. The test results show that the equipment tested is capable of demonstrating complianc…

Text truncated - open the document above for the full version.

Test Setup Photos

SETUP PHOTOS FCC ID: 2ACQ6-CIF IC: 11481A-CIF Page 1 of 7 UL LLC 12 LABORATORY DR., RESEARCH TRIANGLE PARK, NC 27709 TEL: (919) 549-1400 1. SETUP PHOTOS ANTENNA PORT CONDUCTED RF MEASUREMENT SETUP ANTENNA PORT CONDUCTED PHOTO SETUP PHOTOS FCC ID: 2ACQ6-CIF IC: 11481A-CIF Page 2 of 7 UL LLC 12 LABORATORY DR., RESEARCH TRIANGLE PARK, NC 27709 TEL: (919) 549-1400 RADIATED RF MEASUREMENT SETUP (BELOW 1 GHz) RADIATED FRONT PHOTO (BELOW 1 GHz) SETUP PHOTOS FCC ID: 2ACQ6-CIF IC: 11481A-CIF Page 3 of 7 UL LLC 12 LABORATORY DR., RESEARCH TRIANGLE PARK, NC 27709 TEL: (919) 549-1400 RADIATED BACK PHOTO (BELOW 1 GHz) SETUP PHOTOS FCC ID: 2ACQ6-CIF IC: 11481A-CIF Page 4 of 7 UL LLC 12 LABORATORY DR., RESEARCH TRIANGLE PARK, NC 27709 TEL: (919) 549-1400 RADIATED RF MEASUREMENT SETUP (ABOVE 1 GHz) RADIATED FRONT PHOTO (ABOVE 1 GHz) SETUP PHOTOS FCC ID: 2ACQ6-CIF IC: 11481A-CIF Page 5 of 7 UL LLC 12 LABORATORY DR., RESEARCH TRIANGLE PARK, NC 27709 TEL: (919) 549-1400 RADIATED BACK PHOTO (ABOVE 1 GHz) SETUP PHOTOS FCC ID: 2ACQ6-CIF IC: 11481A-CIF Page 6 of 7 UL LLC 12 LABORATORY DR., RESEARCH TRIANGLE PARK, NC 27709 TEL: (919) 549-1400 POWERLINE CONDUCTED EMISSIONS MEASUREMENT SETUP LINE CONDUCTED FRONT PHOTO SETUP PHOTOS FCC ID: 2ACQ6-CIF IC: 11481A-CIF Page 7 of 7 UL LLC 12 LABORATORY DR., RESEARCH TRIANGLE PARK, NC 27709 TEL: (919) 549-1400 END OF PHOTOS LINE CONDUCTED BACK PHOTO

Contact Information

Applicant

Samir Syal(Compliance Engineering Manager)
[email protected]9194074630Fax: 9194077928

Test Firm

UL LLCRick Titus
[email protected]847-272-8800Fax: 847-313-3281

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.

Other Applications from Ideal Industries Lighting LLC, DBA CREE Lighting

Wireless Scene Controller - FCC ID 2ACQ6-CSC - Ideal Industries Lighting LLC, DBA CREE Lighting
2ACQ6-CSC

Wireless Scene Controller

Feb 09, 2021

Equipment Class

DTS - Digital Transmission System
WALL SWITCH - FCC ID 2ACQ6-CWC - Ideal Industries Lighting LLC, DBA CREE Lighting
2ACQ6-CWC

WALL SWITCH

Aug 23, 2014

Equipment Class

DTS - Digital Transmission System
2.4 GHz Transceiver - FCC ID 2ACQ6-CCT - Ideal Industries Lighting LLC, DBA CREE Lighting
2ACQ6-CCT

2.4 GHz Transceiver

Aug 16, 2014

Equipment Class

DTS - Digital Transmission System
RFM MODULE - FCC ID 2ACQ6-RFM - Ideal Industries Lighting LLC, DBA CREE Lighting
2ACQ6-RFM

RFM MODULE

Jul 22, 2014

Equipment Class