Mounting instructions Torque flange T40C1 (MPZ1006008 / MPZ1006009) Version b 13.01.2015 HBM: public Table of contents 1 Safety instructions ........................................................................................ 1 2 Markings used .............................................................................................. 7 2.1 Symbols on the transducer ............................................................................................................... 7 2.2 The markings used in this document ............................................................................................ 7 3 Application .................................................................................................. 8 4 Structure and mode of operation .................................................................. 9 5 Mechanical installation ............................................................................. 11 5.1 Important precautions during installation ..................................................................................... 11 5.2 Conditions on site ............................................................................................................................. 12 5.3 Mounting position .............................................................................................................................. 12 5.4 Installation options ........................................................................................................................... 12 5.4.1 Installation without dismantling the antenna ring ................................................................................ 13 5.4.2 Installation with subsequent stator mounting ................................................................................... 14 5.5 Mounting the rotor ............................................................................................................................... 15 5.6 Mounting the stator ............................................................................................................................ 17 5.7 Speed measuring system (optional) ............................................................................................ 21 6 Electrical connection ............................................................................... 23 6.1 General instructions ......................................................................................................................... 23 6.2 EMC protection .................................................................................................................................. 23 6.3 Connector pin assignment ............................................................................................................. 25 6.4 S upply voltage ................................................................................................................................... 27 7 Shunt signal ............................................................................................. 28 8 Functionality testing ................................................................................... 29 8.1 Rotor status, LED A (upper LED) ................................................................................................... 29 Version b 13.01.2015 HBM: public 8.2 Stator status, LED B (lower LED) ............................................................................................... 30 9 Loading capacity ...................................................................................... 31 10 Maintenance ........................................................................................... 32 11 Waste disposal and environmental protection...................................... 32 12 Dimensions ............................................................................................. 33 12.1 Torque flange - 15kN·m ................................................................................................................. 33 12.2 Torque flange - 25kN·m .................................................................................................................... 33 13 Order numbers, accessories .................................................................. 35 14 Specifications .......................................................................................... 36 15 Supplementary technical information ........................................................ 40 Version b 13.01.2015 HBM: public 1 1 Safety instructions FCC Compliance & Advisory Statement for Option 7, Code U Important Any changes or modification not expressly approved in writing by the party responsible for compliance could void the user’s authority to operate the device. Where specified additional components or accessories elsewhere defined to be used with the installation of the product, they must be used in order to ensure compliance with FCC regulations. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The FCC identifier or the unique identifier, as appropriate, must be displayed on the device. Model Measuring range FCC ID T40C1 - MPZ1006008 15 kN·m 2ADAT-T40C1 T40C1 - MPZ1006009 25 kN·m 2ADAT-T40C1 Version b 13.01.2015 HBM: public 2 Label example with FCC ID and IC number FCC ID: 2ADAT-T40C1 Position Fig. 1.1 Location of the label on the stator of the device Fig. 1.2 Example of the label Version b 13.01.2015 HBM: public 3 Industry Canada for Option 7, Code U Darmstadt, 2014-11-13 This product has not yet received IC (Industry Canada) approval. The certification process for this product is still under way. HBM currently expects that IC approval will be granted by the end of December 2014. Your local HBM contact looks forward…
Text truncated - open the document above for the full version.
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40C1 140714-AU02+W01 Annex B Page 1 of 5 1 Annex B – EUT pictures 1.1 List of Pictures Picture 1: EUT front side.................................................................................................... 2 Picture 2: EUT rear side .................................................................................................... 2 Picture 3: EUT left side ...................................................................................................... 3 Picture 4: EUT right side .................................................................................................... 3 Picture 5: PCB rotor front side ........................................................................................... 4 Picture 6: PCB rotor rear side ............................................................................................ 4 Picture 7: PCB stator front side ......................................................................................... 5 Picture 8: PCB stator rear side .......................................................................................... 5 Picture 9: Label .................................................................................................................. 5 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40C1 140714-AU02+W01 Annex B Page 2 of 5 1.2 EUT pictures Picture 1: EUT front side Picture 2: EUT rear side EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40C1 140714-AU02+W01 Annex B Page 3 of 5 Picture 3: EUT left side Picture 4: EUT right side EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40C1 140714-AU02+W01 Annex B Page 4 of 5 Picture 5: PCB rotor front side Picture 6: PCB rotor rear side EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40C1 140714-AU02+W01 Annex B Page 5 of 5 Picture 7: PCB stator front side Picture 8: PCB stator rear side Picture 9: Label Managing Director: Andreas Hüllhorst – Chairman of the Board: Eoghan O’Lionaird Registered at Darmstadt HRB 1147 HBM: public LABEL FCC ID: 2ADAT-T40C1 Position
Managing Director: Andreas Hüllhorst – Chairman of the Board: Eoghan O’Lionaird Registered at Darmstadt HRB 1147 HBM: public LABEL FCC ID: 2ADAT-T40C1 Position Managing Director: Andreas Hüllhorst – Chairman of the Board: Eoghan O’Lionaird Registered at Darmstadt HRB 1147 HBM: public Schriftgröße/n - Font size/s FCC ID bzw. CI Code min. 8 Punkte [*pt] = ~2,8 mm Stellungnahme - Statement Text min. 5 Punkte [*pt] = ~1,8 mm *DTO-Punkte / 1 pt = 0,35 27 mm Abmessungen – Dimension [mm] B = 50,0 +2 H = 21,0 +2 R = 1,0 ±0,2 Material: self-adhesive polyester security film, 60 μm Color: silver, matt coated Adhesive: Permanent adhesive Temperature range: -40 ° C to +150 ° C Characteristics: weather resistant, sea water, resistant to many solvents, weak acids and alkalis
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40C1 140714-AU02+W01 Annex B Page 1 of 5 1 Annex B – EUT pictures 1.1 List of Pictures Picture 1: EUT front side.................................................................................................... 2 Picture 2: EUT rear side .................................................................................................... 2 Picture 3: EUT left side ...................................................................................................... 3 Picture 4: EUT right side .................................................................................................... 3 Picture 5: PCB rotor front side ........................................................................................... 4 Picture 6: PCB rotor rear side ............................................................................................ 4 Picture 7: PCB stator front side ......................................................................................... 5 Picture 8: PCB stator rear side .......................................................................................... 5 Picture 9: Label .................................................................................................................. 5 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40C1 140714-AU02+W01 Annex B Page 2 of 5 1.2 EUT pictures Picture 1: EUT front side Picture 2: EUT rear side EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40C1 140714-AU02+W01 Annex B Page 3 of 5 Picture 3: EUT left side Picture 4: EUT right side EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40C1 140714-AU02+W01 Annex B Page 4 of 5 Picture 5: PCB rotor front side Picture 6: PCB rotor rear side EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40C1 140714-AU02+W01 Annex B Page 5 of 5 Picture 7: PCB stator front side Picture 8: PCB stator rear side Picture 9: Label
The test result refers exclusively to the tested model. This test report may not be copied or published in a part without the written authorization of the accreditation agency and/or EMV TESTHAUS GmbH Revision: 1.0 Customer: Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45 64293 Darmstadt Tel.: +49 6151-803-8030 Fax: +49 6151-803-9100 RF test report 140714-AU02+W01 Hottinger Baldwin Messtechnik GmbH Torque meter T40C1 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.0 Hottinger Baldwin Messtechnik GmbH Torque meter T40C1 140714-AU02+W01 Page 2 of 39 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Tel.: +49 9421 56868-0 Fax: +49 9421 56868-100 Email: [email protected] Accreditation: FCC facility registration number: 221458 Test Firm Type “2.948 listed”: Valid until 2017-04-22 Test Firm Type “accredited”: Valid until 2015-06-11 MRA US-EU, FCC designation number: DE0010 BnetzA-CAB-02/21-02/04 Valid until 2018-11-27 Industry Canada test site number: 3472A-1 Registration expiry date: 2015-10-02 Test Laboratory: EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany The technical accuracy is guaranteed through the quality management of the EMV TESTHAUS GmbH EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.0 Hottinger Baldwin Messtechnik GmbH Torque meter T40C1 140714-AU02+W01 Page 3 of 39 Table of contents 1 Test regulations ................................................................................................................... 6 1.1 Summary of test results ................................................................................................ 6 2 Equipment under Test (EUT) ............................................................................................... 7 2.1 Photo documentation ................................................................................................... 8 2.2 Short description of the EUT ........................................................................................ 8 2.3 Operation mode ........................................................................................................... 8 2.4 Configuration ................................................................................................................ 9 2.5 Used cables ................................................................................................................. 9 3 AC power line conducted emissions .................................................................................. 10 3.1 Test location ............................................................................................................... 10 3.2 Test instruments ......................................................................................................... 10 3.3 Limits ......................................................................................................................... 10 3.4 Test procedure ........................................................................................................... 11 3.5 Test setup .................................................................................................................. 11 3.6 Test results ................................................................................................................ 12 4 Radiated emission measurement (<1 GHz) ....................................................................... 16 4.1 Test Location.............................................................................................................. 16 4.2 Test instruments ......................................................................................................... 16 4.3 Limits ......................................................................................................................... 17 4.4 Test procedure ........................................................................................................... 18 4.5 Test setup .................................................................................................................. 19 4.6 Test deviation ............................................................................................................. 19 4.7 Test results ................................................................................................................ 20 5 Radiated emission measurement (>1 GHz) ....................................................................... 29 6 Bandwidths ........................................................................................................................ 30 6.1 Test Location.............................................................................................................. 30 6.2 Test instruments ......................................................................................................... 30 6.3 Limits ......................................................................................................................... 30 6.4 Test setup .................................................................................................................. 30 6.5 Test deviation ............................................................................................................. 30 6.6 Test results ................................................................................................................ 31 7 Equipment calibration status .............................................................................................. 36 8 Measurement uncertainty .................................................................................................. 37 9 Summary ........................................................................................................................... 38 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.0 Hottinger Baldwin Messtechnik GmbH Torque meter T40C1 140714-AU02+W01 Page 4 of …
Text truncated - open the document above for the full version.
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40C1 140714-AU02+W01 Annex A Page 1 of 6 1 Annex A – Test setup 1.1 List of Pictures Picture 1: Test setup radiated emission test 9kHz - 30MHz (front view) ............................ 2 Picture 2: Test setup radiated emission test 9kHz - 30MHz (rear view) ............................ 2 Picture 3: Test setup radiated emission test 30MHz - 1GHz, CDC .................................... 3 Picture 4: Test setup radiated emission test 30MHz - 1GHz, OATS (front view) ............... 3 Picture 5: Test setup radiated emission test 30MHz - 1GHz, OATS (rear view) ................ 4 Picture 6: Test setup with magnetic field probe ................................................................. 4 Picture 7: Test setup with magnetic field probe - zoom to probe ....................................... 5 Picture 8: Test setup conducted emission test (front view) ................................................ 6 Picture 9: Test setup conducted emission test (rear view) ................................................ 6 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40C1 140714-AU02+W01 Annex A Page 2 of 6 1.2 Test setup Picture 1: Test setup radiated emission test 9kHz - 30MHz (front view) Picture 2: Test setup radiated emission test 9kHz - 30MHz (rear view) EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40C1 140714-AU02+W01 Annex A Page 3 of 6 Picture 3: Test setup radiated emission test 30MHz - 1GHz, CDC Picture 4: Test setup radiated emission test 30MHz - 1GHz, OATS (front view) EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40C1 140714-AU02+W01 Annex A Page 4 of 6 Picture 5: Test setup radiated emission test 30MHz - 1GHz, OATS (rear view) Picture 6: Test setup with magnetic field probe EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40C1 140714-AU02+W01 Annex A Page 5 of 6 Picture 7: Test setup with magnetic field probe - zoom to probe EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40C1 140714-AU02+W01 Annex A Page 6 of 6 Picture 8: Test setup conducted emission test (front view) Picture 9: Test setup conducted emission test (rear view)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 1.22 MHz - 1.22 MHz | - |

TJ1S8-2K Torquemeter
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
TCAS4 Torquemeter
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
T40 Torquemeter
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
TJ1S6 Torquemeter
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
T10-S2TOS6 Torquemeter
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter