FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Hottinger Bruel & Kjaer GmbH/
  3. 2ADAT-TJ1S8-2K

2ADAT-TJ1S8-2KTJ1S8-2K Torquemeter

Hottinger Bruel & Kjaer GmbH
TJ1S8-2K Torquemeter - FCC ID 2ADAT-TJ1S8-2K - Hottinger Bruel & Kjaer GmbH
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Mar 16, 2021
Application Purpose
Original Equipment
Date of Application
Mar 16, 2021
Equipment Note
TJ1S8-2K Torquemeter
Frequency Range
13.56000000 - 13.56000000
Company
Hottinger Bruel & Kjaer GmbH
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗
↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Geschäftsführung: Thomas Lippok & Jens Wiegand • Aufsichtsratsvorsitzender: Joseph Vorih Sitz der Gesellschaft: Darmstadt • Als Gesellschaft mit beschränkter Haftung eingetragen im Handelsregister des Amtsgerichts Darmstadt unter HRB 1147 Unser Unternehmen ist bei der Stiftung Elektro-Altgeräte Register (EAR) unter der Nummer WEEE-Reg.-Nr. DE66485129 registriert. CONFIDENTIAL - EXTERNAL Mounting instructions Customized torque transducer based on diaphragm coupling, Project 7HA.03 TJ1S8-2K (MPZ2001019) Geschäftsführung: Thomas Lippok & Jens Wiegand • Aufsichtsratsvorsitzender: Joseph Vorih Sitz der Gesellschaft: Darmstadt • Als Gesellschaft mit beschränkter Haftung eingetragen im Handelsregister des Amtsgerichts Darmstadt unter HRB 1147 Unser Unternehmen ist bei der Stiftung Elektro-Altgeräte Register (EAR) unter der Nummer WEEE-Reg.-Nr. DE66485129 registriert. CONFIDENTIAL - EXTERNAL Directory 1 Safety Instructions ................................................................................................................................... 3 2 Markings used ......................................................................................................................................... 1 2.1 Symbols on the transducer ............................................................................................................. 1 2.2 The markings used in this document ............................................................................................. 2 3 Application ................................................................................................................................................ 2 4 Structure and mode of operation............................................................................................................ 3 5 Mechanical installation ............................................................................................................................ 5 5.1 Important precautions during installation ....................................................................................... 5 5.2 Conditions on site ............................................................................................................................ 6 5.3 Installation orientation...................................................................................................................... 6 5.4 Installation ........................................................................................................................................ 7 5.5 Preparing for the rotor mounting (exemplary) ............................................................................... 7 5.6 Mounting the rotor ............................................................................................................................ 9 5.7 Installing the telemetry system ........................................................................................................ 10 5.7.1 Measuring setup ......................................................................................................................... 11 5.7.2 Instruction for installation ........................................................................................................... 12 5.7.3 Calibration signal........................................................................................................................ 13 5.7.4 Stator antenna ............................................................................................................................ 14 5.7.5 Evaluation unit ............................................................................................................................ 15 6 Electrical connection ............................................................................................................................ 21 6.1 Connector pin assignment ............................................................................................................ 23 6.2 Supply voltage ................................................................................................................................ 23 6.3 Use of EMI suppressor .................................................................................................................. 24 7 Shunt signal ........................................................................................................................................... 26 7 Functional testing .................................................................................................................................. 27 8 Maintenance .......................................................................................................................................... 28 9 Dimensions of the stator antenna ........................................................................................................ 29 10 Dimensions of the rotor antenna ...................................................................................................... 30 11 Specifications ..................................................................................................................................... 31 Geschäftsführung: Thomas Lippok & Jens Wiegand • Aufsichtsratsvorsitzender: Joseph Vorih Sitz der Gesellschaft: Darmstadt • Als Gesellschaft mit beschränkter Haftung eingetragen im Handelsregister des Amtsgerichts Darmstadt unter HRB 1147 Unser Unternehmen ist bei der Stiftung Elektro-Altgeräte Register (EAR) unter der Nummer WEEE-Reg.-Nr. DE66485129 registriert. CONFIDENTIAL - EXTERNAL 1 Safety Instructions FCC Compliance & Advisory Statement Important Any changes or modification not expressly approved in writing by the party responsible for compliance could void the user’s authority to operate the device. Where specified additional components or accessories elsewhere defined to be used with the installation of the product, they must be used in order to ensure compliance with FCC re…

Text truncated - open the document above for the full version.

Cover Letter(s)

Hottinger Brüel & Kjaer GmbH Im Tiefen See 45 64293 Darmstadt Germany www.hbkworld.com Managing Directors: Thomas Lippok & Jens Wiegand – Chairman of the board: Joseph Michael Vorih Registered as GmbH (German limited liability corporation) in the commercial register at the local court of Darmstadt, HRB 1147 Company domiciled in Darmstadt UNR ESTRICTED CONFIDENTIAL - EXTERNAL Hottinger Brüel & Kjaer GmbH Im Tiefen See 45 D-64293 Darmstadt Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 24 Februar 2021 Request of confidentiality for FCC ID: 2ADAT-TJ1S8-2K Gentlemen: This letter is to comply with Sections 0.457 and 0.459 pertaining to confidential material. Hottinger Brüel & Kjaer GmbH would like the following documents regarding this submission for FCC ID: 2ADAT-TJ1S8-2K to be kept confidential. CONFIDENTIAL LIST Permanent 1 Block Diagram 2 Operating Descriptions 3 Schematics The above material contains trade secrets or technical data, which would customarily be guarded from competitors Yours sincerely, Jens Dexheimer Project engineeer

Cover Letter(s)

Hottinger Brüel & Kjaer GmbH Im Tiefen See 45 64293 Darmstadt Germany www.hbkworld.com Managing Directors: Thomas Lippok & Jens Wiegand – Chairman of the board: Joseph Michael Vorih Registered as GmbH (German limited liability corporation) in the commercial register at the local court of Darmstadt, HRB 1147 Company domiciled in Darmstadt UNR ESTRICTED CONFIDENTIAL - EXTERNAL Hottinger Brüel & Kjaer GmbH Im Tiefen See 45 D-64293 Darmstadt Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 24 Februar 2021 Statement Post Market Surveillance for FCC ID: 2ADAT-TJ1S8-2K Gentlemen: This letter is to comply with Sections 0.457 and 0.459 pertaining to confidential material. Hottinger Brüel & Kjaer GmbH would like the following documents regarding this submission for FCC ID: 2ADAT-TJ1S8-2K to be kept confidential. Gentlemen: This letter is to state that this Torque Transducer, Serial No. #201040001 was designed for and in cooperation with our customer to fit in his torque rig shaft. This transducer was built “on demand” and will be rebuilt only at request of this customer or with his dedicated allowance. This transducer will never be on stock. We do not expect to rebuild them in the next years. Due to the fact that the production and certification of the element body will be done in charge of our customer, the lead time for this kind of transducer is roughly one year. At HBK in Germany we “only” refine this element body made from special steel and transform them into a torque transducer. Yours sincerely, Jens Dexheimer Project engineeer

Cover Letter(s)

040197.1E-fc_2021-03-02_GEN_aw.docx FO160_Letter_de_143 1/1 EMCCons DR. RAŠEK GmbH & Co. KG EMCCons DR. RAŠEK GmbH & Co. KG Boelwiese 8 · 91320 Ebermannstadt · Germany EMCCons DR. RAŠEK GmbH & Co. KG Register AG Bamberg HRA 10957 Standort 1/Site 1: Boelwiese 8 Komplementaer/General Partner: ULL-IMMO GmbH Register AG Bamberg HRB 5336 91320 Ebermannstadt, Germany Kommanditist und Geschaeftsfuehrer/Limited Partner and Managing Director: Nathalia A. M. Rašek-Abach, Dr.-Ing. A. R. Abach T: +49 9194 7262-0 UST ID/VAT ID: DE 260 532 877 F: +49 9194 7262-199 NATO CAGE-Code DH547 D-U-N-S # 340880233 Oberbank AG Nuremberg, Germany, EUR BIC: OBKLDEMX IBAN: DE77 7012 0700 1081 1606 89 Standort 2/Site 2: Stoernhofer Berg 15 Volksbank Forchheim, Germany, EUR BIC: GENODEF1FOH IBAN: DE22 7639 1000 0000 1246 99 91364 Unterleinleiter, Germany Raiffeisen-Volksbank Erlangen, Germany, EUR BIC: GENODEF1ER1 IBAN: DE75 7636 0033 0002 6207 31 T: +49 9194 7263-0 UniCredit Bank AG Erlangen, Germany, EUR BIC: HYVEDEMM417 IBAN: DE20 7632 0072 1040 2931 39 E: [email protected] UniCredit Bank AG Erlangen, Germany, USD BIC: HYVEDEMM417 IBAN: DE49 7632 0072 0021 2508 72 www.emcc.de INGENIEURBÜRO/ENGINEERING OFFICE Technische Expertise/Technical Experts Kalibrierung/Calibration Planung/Engineering Forschung & Entwicklung/R & D Prüfung & Messung/Test & Measurement Schulung/Training AKKREDITIERTE PRÜFLABORATORIEN/ ACCREDITED TEST LABORATORIES Calibration: DAkkS # D-K-12067 Electrical Testing: A2LA # 2032.01 EMC: DAkkS # D-PL-12067 Radio: DAkkS # D-PL-12067 Safety: DAkkS # D-PL-12067 Environment: DAkkS # D-PL-12067 Aircraft: DAkkS # D-PL-12067 Railway: DAkkS # D-PL-12067 Vehicle: A2LA # 2032.01 Vehicle: DAkkS # D-PL-12067 Medical: DAkkS # D-PL-12067 Military: DAkkS # D-PL-12067 FCC USA Reg.: # FCC-368753 ISED Canada Listing: # IC-3464 VCCI Japan Reg.: ## VCCI-C, -G, -R, -T Federal Communications Commission 7435 Oakland Mills Rd Columbia, MD 21046 USA Ihr Ansprechpartner/Your Contact: Guenther Proelss T: +49 9194 7263-814 F: +49 9194 7263-889 E: [email protected] Ihre Kontaktdaten/Your Details T: - F: - E: - Ihr Zeichen/Your Reference Unser Zeichen/Our Reference Datum/Date T: +49 9194 7262-0 | F: -199 FCC ID: 2ADAT-TJ1S8-2K Pg/aw-040197.1E/fc 2021-03-11 E: [email protected] | www.emcc.de Subject: TCB Justification for Post Market Surveillance according to KDB 610077 D01 FCC ID: 2ADAT-TJ1S8-2K Dear Madam/Sir This letter is the justification for not keeping a production sample on hand. This has been verified and is acceptable for FCC ID: 2ADAT-TJ1S8-2K. The company Hottinger Brüel & Kjaer GmbH showed satisfactorily the production run of its Torque Transducer is very limited in quantity. Therefore we determine they may not be required to maintain a sample on hand as specified in “KDB 610077 D01 TCB Post Market Surveillance v06r01” from 2015-06-25. If you have any queries, please do not hesitate to contact us. Best regards EMCCert DR. RAŠEK GmbH Günther Prölß

External Photos

PAGE 1 OF 3 EMCCons DR. RAŠEK GmbH & Co. KG Boelwiese 8 91320 Ebermannstadt Germany 040197.1EB Telephone: +49 9194 7262-0 Telefax: +49 9194 7262-199 Mail: [email protected] Web: http://www.emcc.de ANNEX 2 TO TEST REPORT # EMCC-040197.1EB, 2021-03-11 EXTERNAL PHOTOGRAPHS OF EQUIPMENT UNDER TEST EQUIPMENT UNDER TEST: Trade Name: Torque meter Type, Serial Number(s): 7HA.03, 201040001 Application: Low Power Transceiver FCC ID: 2ADAT-TJ1S8-2K Manufacturer: Hottinger Brüel & Kjaer GmbH Address: Im Tiefen See 45 64293 Darmstadt GERMANY Phone: +49 6151 803 8346 E-Mail: [email protected] RELEVANT STANDARD(S) : 47 CFR § 15.203, § 15.207, § 15.209, § 15.225 MEASUREMENT PROCEDURE: ANSI C63.10-2013 ILLUSTRATION LIST ANNEX 2 Photograph A2-1: EUT on wooden support, front side 2 Photograph A2-2: EUT on wooden support, righthand side 2 Photograph A2-3: EUT on wooden support, back side 3 Photograph A2-4: EUT on wooden support, lefthand side 3 Annex 2 to Test Report # EMCC-040197.1EB Page 2 of 3 Issue Date: 2021-03-11 Test on Hottinger Brüel & Kjaer GmbH 7HA.03 to 47 CFR § 15.203, § 15.207, § 15.209, § 15.225 © EMCCons DR. RAŠEK GmbH & Co. KG 040197.1EB Photograph A2-1: EUT on wooden support, front side Photograph A2-2: EUT on wooden support, righthand side Annex 2 to Test Report # EMCC-040197.1EB Page 3 of 3 Issue Date: 2021-03-11 Test on Hottinger Brüel & Kjaer GmbH 7HA.03 to 47 CFR § 15.203, § 15.207, § 15.209, § 15.225 © EMCCons DR. RAŠEK GmbH & Co. KG 040197.1EB Photograph A2-3: EUT on wooden support, back side Photograph A2-4: EUT on wooden support, lefthand side

External Photos

PAGE 1 OF 3 EMCCons DR. RAŠEK GmbH & Co. KG Boelwiese 8 91320 Ebermannstadt Germany 040197.1EC Telephone: +49 9194 7262-0 Telefax: +49 9194 7262-199 Mail: [email protected] Web: http://www.emcc.de ANNEX 2 TO TEST REPORT # EMCC-040197.1EC, 2021-03-11 EXTERNAL PHOTOGRAPHS OF EQUIPMENT UNDER TEST EQUIPMENT UNDER TEST: Trade Name: Torque meter Type, Serial Number(s): 7HA.03, 201040001 Application: Low Power Transceiver FCC ID: 2ADAT-TJ1S8-2K Manufacturer: Hottinger Brüel & Kjaer GmbH Address: Im Tiefen See 45 64293 Darmstadt GERMANY Phone: +49 6151 803 8346 E-Mail: [email protected] RELEVANT STANDARD(S) : 47 CFR § 15.203, § 15.207, § 15.209 MEASUREMENT PROCEDURE: ANSI C63.10-2013 ILLUSTRATION LIST ANNEX 2 Photograph A2-1: EUT on wooden support, front side 2 Photograph A2-2: EUT on wooden support, righthand side 2 Photograph A2-3: EUT on wooden support, back side 3 Photograph A2-4: EUT on wooden support, lefthand side 3 Annex 2 to Test Report # EMCC-040197.1EC Page 2 of 3 Issue Date: 2021-03-11 Test on Hottinger Brüel & Kjaer GmbH 7HA.03 to 47 CFR § 15.203, § 15.207, § 15.209 © EMCCons DR. RAŠEK GmbH & Co. KG 040197.1EC Photograph A2-1: EUT on wooden support, front side Photograph A2-2: EUT on wooden support, righthand side Annex 2 to Test Report # EMCC-040197.1EC Page 3 of 3 Issue Date: 2021-03-11 Test on Hottinger Brüel & Kjaer GmbH 7HA.03 to 47 CFR § 15.203, § 15.207, § 15.209 © EMCCons DR. RAŠEK GmbH & Co. KG 040197.1EC Photograph A2-3: EUT on wooden support, back side Photograph A2-4: EUT on wooden support, lefthand side

ID Label/Location Info

Hottinger Brüel & Kjaer GmbH Im Tiefen See 45 64293 Darmstadt Germany www.hbkworld.com Managing Directors: Thomas Lippok & Jens Wiegand – Chairman of the board: Joseph Michael Vorih Registered as GmbH (German limited liability corporation) in the commercial register at the local court of Darmstadt, HRB 1147 Company domiciled in Darmstadt UNR ESTRICTED Hottinger Brüel & Kjaer GmbH Im Tiefen See 45 D-64293 Darmstadt 24 Februar 2021 LABEL FCC ID: 2ADAT-TJ1S8-2K Position: on the stator unit of the system Hottinger Brüel & Kjaer GmbH Im Tiefen See 45 64293 Darmstadt Germany www.hbkworld.com Managing Directors: Thomas Lippok & Jens Wiegand – Chairman of the board: Joseph Michael Vorih Registered as GmbH (German limited liability corporation) in the commercial register at the local court of Darmstadt, HRB 1147 Company domiciled in Darmstadt Page 2 of 2 UNR ESTRICTED Schriftgröße/n - Font size/s FCC ID bzw. CI Code min. 8 Punkte [*pt] = ~2,8 mm Stellungnahme - Statement Text min. 5 Punkte [*pt] = ~1,8 mm *DTO-Punkte / 1 pt = 0,35 27 mm Abmessungen – Dimension [mm] B = 46.0 +2 H = 21.0 +2 R = 1.0 ±0,2 Material: self-adhesive polyester security film, 60 μm Color: silver, matt coated Adhesive: Permanent adhesive Temperature range: -40 ° C to +150 ° C Characteristics: weather resistant, sea water, resistant to many solvents, weak acids and alkalis 8 5

Internal Photos

1 2 3 4 5 6 7

Test Report

EMtrE' NR. RAÉEK PAGE 1 OF 42 TEST REPORT # EMCC-O4OL97.1EB, 2021-03-11 EQUIPMENT UNDERTEST: Trade Name: Type: Serial Number(s): Equipment Class: FCC ID: Manufacturer: Address: Name: Phone: E-Mail: RETEVANTSTANDARD(S): MEASUREMENT PROCEDURE: TEST REPORT PREPARED BY: Dominik Krüger EMCCons DR. RASEK GmbH & Co. KG Boelwiese 8 9L320 Ebermannstadt Germany Phone: +49 9L947262-332 Fax: +499L947262-]-99 E-Mail: [email protected] Tested: Torque meter 7HA.03 201_04000L Low Power Transceiver 2ADAT-TJ1S8-2K Hottinger Brüel & Kjaer GmbH lm Tiefen See 45 64293 Darmstadt GERMANY Alexander Ehrhard +49 6751,803 8346 a lexander.ehrhard@h bkworld.com 47 CFR 5 1_5.203, S 15.207, S 1_5.209, S 15.225 ANSr C63.10-2013 Approved: i,Ag,fu Dominik Krüger Reinhard Sauerschell 040197.1E8 .*tl.)1% ã ffi ffíonr.r.s ?'íÃìs' tL\- Deutsche -"4rí,r,i..\"' \# Akkreditieruntsstelle D-Pt-12067-01{4 EMCCons on. naSer GmbH & Co. KG Boelwiese 8 91320 Ebermannstadt Germany Telephone: +4991947262-0 Telefax +499I947262-L99 Mail: [email protected] Web: http://www.emcc.de Test Report # EMCC-040197.1EB Page 2 of 42 Issue Date: 2021-03-11 Test on Hottinger Brüel & Kjaer GmbH 7HA.03 to 47 CFR § 15.203, § 15.207, § 15.209, § 15.225 © EMCCons DR. RAŠEK GmbH & Co. KG 040197.1EB CONTENTS PAGE 0 REVISION HISTORY 4 1 GENERAL INFORMATION 5 Purpose 5 1.1 Limits and Reservations 5 1.2 Test Laboratory 5 1.3 Customer 5 1.4 Manufacturer 6 1.5 Dates and Test Location 6 1.6 Ordering Information 6 1.7 Climatic Conditions 6 1.8 2 PRODUCT DESCRIPTION 7 Equipment under Test (EUT) 7 2.1 Intended Use 8 2.2 EUT Peripherals/Simulators 8 2.3 Mode of operation during testing and test setup 8 2.4 Modifications required for compliance 8 2.5 3 TEST RESULTS SUMMARY 9 4 ANTENNA REQUIREMENT 10 Regulation 10 4.1 Test Procedures 10 4.2 Test Result 10 4.3 5 AC POWER LINE CONDUCTED EMISSIONS 11 Regulation 11 5.1 Test Procedures 11 5.2 Test Setup 12 5.3 5.3.1 Detailed Test Data 13 Test Result 14 5.4 6 RADIATED EMISSIONS 9 KHZ – 30 MHZ 15 Regulation 15 6.1 Test Procedures 17 6.2 Test Site Correlation for H Field Measurement in Semi-Anechoic Chamber (SAC) 18 6.3 Calculation of Field Strength Limits 18 6.4 Field Strength Calculation 18 6.5 Test Setup 19 6.6 6.6.1 Detailed Test Data 20 Test Result 21 6.7 7 RADIATED EMISSIONS 30 MHZ – 1 GHZ 22 Regulation 22 7.1 Test Procedures 24 7.2 Calculation of Field Strength Limits 25 7.3 Field Strength Calculation 25 7.4 Test Setup 26 7.5 7.5.1 Detailed Test Data 27 Test Result 27 7.6 8 SPECTRUM MASK 28 Regulation 28 8.1 Test Procedures 28 8.2 Test Site Correlation for H Field Measurement in Semi-Anechoic Chamber (SAC) 29 8.3 Test Report # EMCC-040197.1EB Page 3 of 42 Issue Date: 2021-03-11 Test on Hottinger Brüel & Kjaer GmbH 7HA.03 to 47 CFR § 15.203, § 15.207, § 15.209, § 15.225 © EMCCons DR. RAŠEK GmbH & Co. KG 040197.1EB Calculation of Field Strength Limits 30 8.4 Field Strength Calculation 30 8.5 Test Setup 31 8.6 8.6.1 Detailed Test Data 32 Test Result 32 8.7 9 CARRIER FREQUENCY STABILITY VS TEMPERATURE 33 Regulation 33 9.1 Test Procedures 33 9.2 Test Setup 34 9.3 Test Result 35 9.4 10 CARRIER FREQUENCY STABILITY VS SUPPLY VOLTAGE 37 Regulation 37 10.1 Test Procedures 37 10.2 Test Setup 38 10.3 Test Result 39 10.4 11 TEST INSTRUMENTS 40 12 MEASUREMENT UNCERTAINTY 41 13 LIST OF ANNEXES 42 Test Report # EMCC-040197.1EB Page 4 of 42 Issue Date: 2021-03-11 Test on Hottinger Brüel & Kjaer GmbH 7HA.03 to 47 CFR § 15.203, § 15.207, § 15.209, § 15.225 © EMCCons DR. RAŠEK GmbH & Co. KG 040197.1EB 0 REVISION HISTORY Project number Issue date Chapter Description 040197.1EB 2021-03-11 n.a. Initial issue Test Report # EMCC-040197.1EB Page 5 of 42 Issue Date: 2021-03-11 Test on Hottinger Brüel & Kjaer GmbH 7HA.03 to 47 CFR § 15.203, § 15.207, § 15.209, § 15.225 © EMCCons DR. RAŠEK GmbH & Co. KG 040197.1EB 1 GENERAL INFORMATION Purpose 1.1 The purpose of this report is to show compliance with the 47 CFR § 15.203, § 15.207, § 15.209, § 15.225 requirements applicable to intentional radiators. Limits and Reservations 1.2 The test results in this report apply only to the particular equipment under test (EUT) as declared in this report. This test report shall not be reproduced except in full without the written permission of EMCCons DR. RAŠEK GmbH & Co. KG. Document(s) and/or information, which were provided by the customer, can affect the validity of results. Test Laboratory 1.3 Test Laboratory: EMCCons DR. RAŠEK GmbH & Co. KG Accreditation No.: D-PL-12067-01-04 FCC Test Firm Registration No.: 368753 Address of Labs I, II, III EMCCons DR. RAŠEK GmbH & Co. KG and Head Office: Boelwiese 8 91320 Ebermannstadt GERMANY Address of Labs IV and V: EMCCons DR. RAŠEK GmbH & Co. KG Stoernhofer Berg 15 91364 Unterleinleiter GERMANY Phone: +49 9194 7262-0 Fax: +49 9194 7262-199 E-Mail: [email protected] Web: www.emcc.de Customer 1.4 Company Name: Hottinger Brüel & Kjaer GmbH Street: Im Tiefen See 45 City: 64293 Darmstadt Country: GERMANY Name: Mr Alexander Ehrhard Phone: +49 6151 803 8346 Fax: +49 6151 803 98346 E-Mail: [email protected] Test Report # EMCC-040197.1EB Page 6 of 42 Issue Date: 2021-03-11 Test on Hottinger Brüel & Kjaer GmbH 7HA.03 to 47 CFR § 15.203, § 15.207, § 15.209, § 15.225 © EMCCons DR. RAŠEK GmbH & Co. KG 040197.1EB Manufacturer 1.5 Company Name: Hottinger Brüel & Kjaer GmbH Street: Im Tiefen See 45 City: 64293 Darmstadt Country: Germany Phone: +49 6151 803 8346 E-Mail: [email protected] Dates and Test Location 1.6 Date of receipt of EUT: 2020-11-17, 2021-02-15 Test Date: CW 47/2020, CW 7/2021 Test Location: Lab IV Ordering Information 1.7 Purchase Order: D29-4500741875/2000 Date: 2020-09-11 Vendor-Number: 806266 Climatic Conditions 1.8 Date Temperature Relative Humidity Air Pressure Lab Customer attended tests -- °C % hPa -- -- 2020-11-19 22 37 979 IV No 2020-11-20 22 34 991 IV No 2021-02-16 21 26 979 IV No 2021-02-17 22 30 978 IV No 2021-02-18 22 29 976 IV No Test Report # EMCC-040197.1EB Page 7 of 42 Issue Date: 20…

Text truncated - open the document above for the full version.

Test Report

PAGE 1 OF 9 EMCCons DR. RAŠEK GmbH & Co. KG Boelwiese 8 91320 Ebermannstadt Germany 040197.1EB Telephone: +49 9194 7262-0 Telefax: +49 9194 7262-199 Mail: [email protected] Web: http://www.emcc.de ANNEX 3 TO TEST REPORT # EMCC-040197.1EB, 2021-03-11 PHOTOGRAPHS OF ANCILLARY EQUIPMENT EQUIPMENT UNDER TEST: Trade Name: Torque meter Type, Serial Number(s): 7HA.03, 201040001 Application: Low Power Transceiver FCC ID: 2ADAT-TJ1S8-2K Manufacturer: Hottinger Brüel & Kjaer GmbH Address: Im Tiefen See 45 64293 Darmstadt GERMANY Phone: +49 6151 803 8346 E-Mail: [email protected] RELEVANT STANDARD(S) : 47 CFR § 15.203, § 15.207, § 15.209, § 15.225 MEASUREMENT PROCEDURE: ANSI C63.10-2013 ILLUSTRATION LIST ANNEX 3 Photograph A3-1: Channel 1 Axon system control unit #36807, front 2 Photograph A3-2: Channel 1 Axon system control unit #36807, label 2 Photograph A3-3: Channel 1 Axon system control unit #36807, back 3 Photograph A3-4: Channel 2 Axon system control unit #41106, front 3 Photograph A3-5: Channel 2 Axon system control unit #41106, label 4 Photograph A3-6: Channel 2 Axon system control unit #41106, back 4 Photograph A3-7: Stator unit JX-SR70TL, # 38235 5 Photograph A3-8: Power supply TRIO-PS/1AC/24DC/5, label 5 Photograph A3-9: Power supply TRIO-PS/1AC/24DC/5, front 6 Photograph A3-10: Power supply TRIO-PS/1AC/24DC/5, back 6 Photograph A3-11: Signal and power cable 7 Photograph A3-12: Signal and power cable, detailed view of ferrites (Wuerth 742 711 31) 7 Photograph A3-13: Equipment for frequency stability tests 8 Photograph A3-14: Rotor unit #41385 8 Photograph A3-15: Dummy magnetic loop antenna with stator unit 9 Annex 3 to Test Report # EMCC-040197.1EB Page 2 of 9 Issue Date: 2021-03-11 Test on Hottinger Brüel & Kjaer GmbH 7HA.03 to 47 CFR § 15.203, § 15.207, § 15.209, § 15.225 © EMCCons DR. RAŠEK GmbH & Co. KG 040197.1EB Photograph A3-1: Channel 1 Axon system control unit #36807, front Photograph A3-2: Channel 1 Axon system control unit #36807, label Annex 3 to Test Report # EMCC-040197.1EB Page 3 of 9 Issue Date: 2021-03-11 Test on Hottinger Brüel & Kjaer GmbH 7HA.03 to 47 CFR § 15.203, § 15.207, § 15.209, § 15.225 © EMCCons DR. RAŠEK GmbH & Co. KG 040197.1EB Photograph A3-3: Channel 1 Axon system control unit #36807, back Photograph A3-4: Channel 2 Axon system control unit #41106, front Annex 3 to Test Report # EMCC-040197.1EB Page 4 of 9 Issue Date: 2021-03-11 Test on Hottinger Brüel & Kjaer GmbH 7HA.03 to 47 CFR § 15.203, § 15.207, § 15.209, § 15.225 © EMCCons DR. RAŠEK GmbH & Co. KG 040197.1EB Photograph A3-5: Channel 2 Axon system control unit #41106, label Photograph A3-6: Channel 2 Axon system control unit #41106, back Annex 3 to Test Report # EMCC-040197.1EB Page 5 of 9 Issue Date: 2021-03-11 Test on Hottinger Brüel & Kjaer GmbH 7HA.03 to 47 CFR § 15.203, § 15.207, § 15.209, § 15.225 © EMCCons DR. RAŠEK GmbH & Co. KG 040197.1EB Photograph A3-7: Stator unit JX-SR70TL, # 38235 Photograph A3-8: Power supply TRIO-PS/1AC/24DC/5, label Annex 3 to Test Report # EMCC-040197.1EB Page 6 of 9 Issue Date: 2021-03-11 Test on Hottinger Brüel & Kjaer GmbH 7HA.03 to 47 CFR § 15.203, § 15.207, § 15.209, § 15.225 © EMCCons DR. RAŠEK GmbH & Co. KG 040197.1EB Photograph A3-9: Power supply TRIO-PS/1AC/24DC/5, front Photograph A3-10: Power supply TRIO-PS/1AC/24DC/5, back Annex 3 to Test Report # EMCC-040197.1EB Page 7 of 9 Issue Date: 2021-03-11 Test on Hottinger Brüel & Kjaer GmbH 7HA.03 to 47 CFR § 15.203, § 15.207, § 15.209, § 15.225 © EMCCons DR. RAŠEK GmbH & Co. KG 040197.1EB Photograph A3-11: Signal and power cable Photograph A3-12: Signal and power cable, detailed view of ferrites (Wuerth 742 711 31) Annex 3 to Test Report # EMCC-040197.1EB Page 8 of 9 Issue Date: 2021-03-11 Test on Hottinger Brüel & Kjaer GmbH 7HA.03 to 47 CFR § 15.203, § 15.207, § 15.209, § 15.225 © EMCCons DR. RAŠEK GmbH & Co. KG 040197.1EB Photograph A3-13: Equipment for frequency stability tests Photograph A3-14: Rotor unit #41385 Annex 3 to Test Report # EMCC-040197.1EB Page 9 of 9 Issue Date: 2021-03-11 Test on Hottinger Brüel & Kjaer GmbH 7HA.03 to 47 CFR § 15.203, § 15.207, § 15.209, § 15.225 © EMCCons DR. RAŠEK GmbH & Co. KG 040197.1EB Photograph A3-15: Dummy magnetic loop antenna with stator unit

Test Report

tl EMtrE. trR. RAÉEK PAGE 1 OF 29 TEST REPORT # EMCC-O4OL97.1EC, 2021-03-11 EQUIPMENT UNDERTEST: Trade Name: Type: Serial Number(s): Equipment Class: FCC ID: Manufacturer: Address: Name: Phone: E-Mail: RELEVANT STANDARD(S): MEASU REMENT PROCEDU RE: TEST REPORT PREPARED BY: Dominik Krüger EMCCons DR. RASEK GmbH & Co. KG Boelwiese 8 9L320 Ebermannstadt Germany Phone: +49 9194 7262-332 Fax: +4991947262-199 E-Mail: [email protected] Tested: Torque meter 7H4.03 20L040001 Low Power Transceiver 2ADAT-TJ158-2K Hottinger Brüel & Kjaer GmbH lm Tiefen See 45 64293 Darmstadt GERMANY Alexander Ehrhard +49 6I5L 803 8346 alexa nder.ehrha rd@h bkworld.com 47 CFR s 1_5.203, s 1_5.207, S 15.209 ANSt C63.1_0-2013 Approved: Dominik Krüger Reinhard Sauerschell 040197.1EC ..:.tJj% ,^' lff flío*r.s -'lÃì¡' t-\- Deutsch€ -'%rí¡,ì'N \È7 Alkreditierungsstelle ùPl-12067€1€4 EMCCons on. nlser GmbH & Co. KG Boelwiese 8 91320 Ebermannstadt Germany Telephone: +499L947262-0 Telefax +4991947262-199 Mail: [email protected] Web: http://www.emcc.de Test Report # EMCC-040197.1EC Page 2 of 29 Issue Date: 2021-03-11 Test on Hottinger Brüel & Kjaer GmbH 7HA.03 to 47 CFR § 15.203, § 15.207, § 15.209 © EMCCons DR. RAŠEK GmbH & Co. KG 040197.1EC CONTENTS PAGE 0 REVISION HISTORY 3 1 GENERAL INFORMATION 4 Purpose 4 1.1 Limits and Reservations 4 1.2 Test Laboratory 4 1.3 Customer 4 1.4 Manufacturer 5 1.5 Dates and Test Location 5 1.6 Ordering Information 5 1.7 Climatic Conditions 5 1.8 2 PRODUCT DESCRIPTION 6 Equipment under Test (EUT) 6 2.1 Intended Use 7 2.2 EUT Peripherals/Simulators 7 2.3 Mode of operation during testing and test setup 7 2.4 Modifications required for compliance 7 2.5 3 TEST RESULTS SUMMARY 8 4 ANTENNA REQUIREMENT 9 Regulation 9 4.1 Test Procedures 9 4.2 Test Result 9 4.3 5 AC POWER LINE CONDUCTED EMISSIONS 10 Regulation 10 5.1 Test Procedures 10 5.2 Test Setup 11 5.3 5.3.1 Detailed Test Data 12 Test Result 13 5.4 6 RADIATED EMISSIONS 9 KHZ – 30 MHZ 14 Regulation 14 6.1 Test Procedures 16 6.2 Test Site Correlation for H Field Measurement in Semi-Anechoic Chamber (SAC) 17 6.3 Calculation of Field Strength Limits 17 6.4 Field Strength Calculation 17 6.5 Test Setup 18 6.6 6.6.1 Detailed Test Data 19 Test Result 20 6.7 7 RADIATED EMISSIONS 30 MHZ – 1 GHZ 21 Regulation 21 7.1 Test Procedures 23 7.2 Calculation of Field Strength Limits 24 7.3 Field Strength Calculation 24 7.4 Test Setup 25 7.5 7.5.1 Detailed Test Data 26 Test Result 26 7.6 8 TEST INSTRUMENTS 27 9 MEASUREMENT UNCERTAINTY 28 10 LIST OF ANNEXES 29 Test Report # EMCC-040197.1EC Page 3 of 29 Issue Date: 2021-03-11 Test on Hottinger Brüel & Kjaer GmbH 7HA.03 to 47 CFR § 15.203, § 15.207, § 15.209 © EMCCons DR. RAŠEK GmbH & Co. KG 040197.1EC 0 REVISION HISTORY Project number Issue date Chapter Description 040197.1EC 2021-03-11 n.a. Initial issue Test Report # EMCC-040197.1EC Page 4 of 29 Issue Date: 2021-03-11 Test on Hottinger Brüel & Kjaer GmbH 7HA.03 to 47 CFR § 15.203, § 15.207, § 15.209 © EMCCons DR. RAŠEK GmbH & Co. KG 040197.1EC 1 GENERAL INFORMATION Purpose 1.1 The purpose of this report is to show compliance with the 47 CFR § 15.203, § 15.207, § 15.209 requirements applicable to intentional radiators. Limits and Reservations 1.2 The test results in this report apply only to the particular equipment under test (EUT) as declared in this report. This test report shall not be reproduced except in full without the written permission of EMCCons DR. RAŠEK GmbH & Co. KG. Document(s) and/or information, which were provided by the customer, can affect the validity of results. Test Laboratory 1.3 Test Laboratory: E…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Michael Korner
[email protected]+49 6151 803Fax: +49 6151 8039100

Test Firm

Dekra Testing and Certification S.r.l.Francesco Boschiero
[email protected]+39 0445 367702Fax: +39 0445 367702

Technical Specifications

#Rule PartsFrequency RangePower Output
315C13.56 MHz - 13.56 MHz-
Confidentiality
Long Term
Grant Notes
A specific ferrite VITROPERM® 500 F, Type: T60006-L2063-W517, Number of turns: 3, must be attached to signal and supply connector to the port of the stator unit, type JX-SR70T. The distance to the connector should be approximately 40 cm. Further a ferrite Würth 742 711 31 must be attached next to the connector of the Axon control unit.

Other Applications from Hottinger Bruel & Kjaer GmbH

TCAS4 Torquemeter - FCC ID 2ADAT-TCAS4 - Hottinger Bruel & Kjaer GmbH
2ADAT-TCAS4

TCAS4 Torquemeter

Nov 04, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
T40 Torquemeter - FCC ID 2ADAT-T40S0TOS1 - Hottinger Bruel & Kjaer GmbH
2ADAT-T40S0TOS1

T40 Torquemeter

Dec 13, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
TJ1S6 Torquemeter - FCC ID 2ADAT-TJ1S6 - Hottinger Bruel & Kjaer GmbH
2ADAT-TJ1S6

TJ1S6 Torquemeter

Jun 11, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
T10-S2TOS6 Torquemeter - FCC ID 2ADAT-T10S2TOS6 - Hottinger Bruel & Kjaer GmbH
2ADAT-T10S2TOS6

T10-S2TOS6 Torquemeter

Feb 18, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
T40-S7TOS9 Torquemeter - FCC ID 2ADAT-T40S7TOS9 - Hottinger Bruel & Kjaer GmbH
2ADAT-T40S7TOS9

T40-S7TOS9 Torquemeter

Jan 27, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter