
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Mounting Instructions | Montageanleitung EnglishDeutsch T40FM Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45 D-64239 Darmstadt Tel. +49 6151 803-0 Fax +49 6151 803-9100 Email: [email protected] Internet: www.hbm.com Mat.: 7-2001.3276 DVS: A3276-8.0 HBM: public 02.2015 E Hottinger Baldwin Messtechnik GmbH. Subject to modifications. All product descriptions are for general information only. They are not to be understood as a guarantee of quality or durability. Änderungen vorbehalten. Alle Angaben beschreiben unsere Produkte in allgemeiner Form. Sie stellen keine Beschaffenheits- oder Haltbarkeits garantie dar. Mounting Instructions | Montageanleitung EnglishDeutsch T40FM 2A3276-8.0 HBM: publicT40FM English 1Safety information4........................................ 2Markings used11............................................ 2.1Symbols on the transducer11.................................. 2.2The marking used in this document12........................... 3Applications13.............................................. 4Structure and Mode of Operation14.......................... 5Mechanical installation19.................................... 5.1Important precautions during installation19...................... 5.2Conditions on site20.......................................... 5.3Installation orientation21...................................... 5.4Installation options21......................................... 5.4.1Installation without dismantling the antenna ring, FCC option with antenna shielding cover22..................................... 5.4.2Installation with subsequent stator mounting, Option 7, Code S23... 5.5Preparing for the rotor mounting24............................. 5.6Mounting the rotor27.......................................... 5.7Installing the stator31......................................... 5.8Mounting the rotational speed flange (rotational speed measuring system only)38.............................................. 6Electrical Connection41..................................... 6.1General information41........................................ 6.2EMC protection41............................................ 6.3Pin Assignment43............................................ 6.4Supply Voltage50............................................ T40FMA3276-8.0 HBM: public3 7Shunt signal52.............................................. 8Functionality testing53...................................... 8.1Rotor status, LED A (upper LED)54............................. 8.2Stator status, LED B (lower LED)55............................ 9Loading capacity56......................................... 10Maintenance58.............................................. 11Waste disposal and environmental protection59.............. 12Dimensions60.............................................. 12.1T40FM without speed measurement, Option 7, Code S60......... 12.1.1 T40FM 15kNm - 25kNm60................................... 12.1.2 T40FM 30kNm - 50kNm62................................... 12.1.3 T40FM 60kNm - 80kNm63................................... 12.2T40FM with speed measurement, Option 7, Code S64............ 12.2.1 T40FM 15kNm - 25kNm64................................... 12.2.2 T40FM 30kNm - 50kNm66................................... 12.2.3 T40FM 60kNm - 80kNm68................................... 12.3T40FM with rotational speed measurement and reference signal, Option 7, Code S70.......................................... 12.3.1 T40FM 15kNm - 25kNm70................................... 12.3.2 T40FM 30kNm - 50kNm72................................... 12.3.3 T40FM 60kNm - 80kNm74................................... 13Order numbers, Accessories76.............................. 14Specifications78............................................ 15Supplementary Technical Information88...................... Safety information 4A3276-8.0 HBM: publicT40FM 1Safety information FCC Compliance & Advisory Statement Important Any changes or modification not expressly approved in writing by by the party responsible for compliance could void the user’s authority to operate the device. Where specified additional components or accessories else where defined to be used with the installation of the product, they must be used in order to ensure compliance with FCC regulations. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, includ ing interference that may cause undesired operation. The FCC identifier or the unique identifier, as appropriate, must be displayed on the device. ModelMeasuring rangeFCC IDIC T40S7 15 kNm, 20 kNm, 25 kNm 2ADAT−T40S7TOS912438A−T40S7TOS9 T40S8 30 kNm, 40 kNm, 50 kNm T40S9 60 kNm, 70 kNm, 80 kNm Safety information T40FMA3276-8.0 HBM: public5 Label example with FCC ID and IC number. Model: T40S7 FCC ID: 2ADAT-T40S7TOS9 IC: 12438AT40S7TOS9 This device complies with part 15 of the FCC Rules. Opera tion is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Label Fig. 1.1Location of the label on the stator of the device Model: T40S7 FCC ID: 2ADAT-T40S7TOS9 IC: 12438AT40S7TOS9 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Fig. 1.2Example of the label Safety information 6A3276-8.0 HBM: publicT40FM This device complies with Industry Canada standard RSS210. This device complies with Industry Canada license−exempt RSS standard(s).Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any in…
Text truncated - open the document above for the full version.
Variants FCC-Certification FCC ID: 2ADAT-T40S7TOS9 IC: 12438A-T40S7TOS9 HBM: public 1 15.10.2014 © HBM Type Approval Electrical Parts Variations of mechanical parts of rotor (variations have same RF Characteristic) T40FM - Family 2 15.10.2014 HBM: public customized 15KNm 20KNm 25Nm customized 30KNm 40kNm customized 60kNm 70kNm S7 Neue Bilder mit Blechen einfügen S8 S9 ØD=293,5mm ØD=323,5mm ØD=250,5mm ØD ØD ØD 50KNm 80KNm © HBM One type will be EMC tested Description of mechanical rotor variations of one size (e.g. S7) 3 HBM: public 15.10.2014 ØD Basis elements (stator and all electrical parts on the rotor) - for each size (e.g. S7) these parts are always the same) Same RF Characteristics: •All types of one size have the same stator, same primary coil, same rotor PCB, same secondary coil on the rotor and have complete metallic housing of rotor and stator. Each size has a special matching circuit for the primary / secondary coil. Possible mechanical modifications (no influence RF characteristic): •Variations of the thickness of the strain detection zone to realize different torque ranges (e.g. 15kNm, 20kNm,...) •Variations of flanges (e.g. diameter of PCD, length, ...) to realize different mechanical interface (mountable to customers counter flange) Optional: •Magnetic speed module with a magnetic ring on the rotor and a speed sensor (with electronics) on the stator. •This part is part of the digital device and has no influence to the RF characteristic. Strain detection zone Mechanical variations (examples) Rotor PCB Stator (including primary coil, (for each size defined diameter) Secondary coil on rotor (for each size defined diameter) Flange
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7, T40S8, T40S9 140714-AU01+W01 Annex B Page 1 of 13 1 Annex B – EUT pictures 1.1 List of Pictures Picture 1: EUT left side, T40S7 ......................................................................................... 2 Picture 2: EUT right side, T40S7 ....................................................................................... 2 Picture 3: PCB rotor front side, T40S7 .............................................................................. 3 Picture 4: PCB rotor rear side, T40S7 ............................................................................... 3 Picture 5: PCB stator front side, T40S7 ............................................................................. 4 Picture 6: PCB stator rear side, T40S7 .............................................................................. 4 Picture 7: EUT left side, T40S8 ......................................................................................... 5 Picture 8: EUT right side, T40S8 ....................................................................................... 5 Picture 9: PCB rotor front side, T40S8 .............................................................................. 6 Picture 10: PCB rotor rear side, T40S8 ............................................................................. 6 Picture 11: PCB stator front side, T40S8 ........................................................................... 7 Picture 12: PCB stator rear side, T40S8 ............................................................................ 7 Picture 13: EUT left side, T40S9 ....................................................................................... 8 Picture 14: EUT right side, T40S9 ..................................................................................... 8 Picture 15: PCB rotor front side, T40S9 ............................................................................ 9 Picture 16: PCB rotor rear side, T40S9 ............................................................................. 9 Picture 17: PCB stator front side, T40S9 ........................................................................... 10 Picture 18: PCB stator rear side, T40S9 ............................................................................ 10 Picture 19: Labels, T40S7 - T40S9 .................................................................................... 11 Picture 20: Data cable termination box - front.................................................................... 12 Picture 21: Data cable termination box - right side ............................................................ 12 Picture 22: Data cable termination box - left side .............................................................. 13 Picture 23: DC power supply ............................................................................................. 13 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7, T40S8, T40S9 140714-AU01+W01 Annex B Page 2 of 13 1.2 EUT pictures - T40S7 Picture 1: EUT left side, T40S7 Picture 2: EUT right side, T40S7 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7, T40S8, T40S9 140714-AU01+W01 Annex B Page 3 of 13 Picture 3: PCB rotor front side, T40S7 Picture 4: PCB rotor rear side, T40S7 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7, T40S8, T40S9 140714-AU01+W01 Annex B Page 4 of 13 Picture 5: PCB stator front side, T40S7 Picture 6: PCB stator rear side, T40S7 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7, T40S8, T40S9 140714-AU01+W01 Annex B Page 5 of 13 1.3 EUT pictures - T40S8 Picture 7: EUT left side, T40S8 Picture 8: EUT right side, T40S8 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7, T40S8, T40S9 140714-AU01+W01 Annex B Page 6 of 13 Picture 9: PCB rotor front side, T40S8 Picture 10: PCB rotor rear side, T40S8 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7, T40S8, T40S9 140714-AU01+W01 Annex B Page 7 of 13 Picture 11: PCB stator front side, T40S8 Picture 12: PCB stator rear side, T40S8 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7, T40S8, T40S9 140714-AU01+W01 Annex B Page 8 of 13 1.4 EUT pictures - T40S9 Picture 13: EUT left side, T40S9 Picture 14: EUT right side, T40S9 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7, T40S8, T40S9 140714-AU01+W01 Annex B Page 9 of 13 Picture 15: PCB rotor front side, T40S9 Picture 16: PCB rotor rear side, T40S9 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7, T40S8, T40S9 140714-AU01+W01 Annex B Page 10 of 13 Picture 17: PCB stator front side, T40S9 Picture 18: PCB stator rear side, T40S9 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7, T40S8, T40S9 140714-AU01+W01 Annex B Page 11 of 13 1.5 EUT pictures - labels Picture 19: Labels, T40S7 - T40S9 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7, T40S8, T40S9 140714-AU01+W01 Annex B Page 12 of 13 1.6 EUT pictures - perpheral devices Picture 20: Data cable termination box - front Picture 21: Data cable termination box - right side EMV TESTHAUS GmbH Gustav-Her…
Text truncated - open the document above for the full version.
Managing Director: Andreas Hüllhorst – Chairman of the Board: Eoghan O’Lionaird Registered at Darmstadt HRB 1147 HBM: public LABEL FCC ID: 2ADAT-T40S7TOS9 IC: 12438A-T40S7TOS9 Position Managing Director: Andreas Hüllhorst – Chairman of the Board: Eoghan O’Lionaird Registered at Darmstadt HRB 1147 HBM: public Schriftgröße/n - Font size/s FCC ID bzw. CI Code min. 8 Punkte [*pt] = ~2,8 mm Stellungnahme - Statement Text min. 5 Punkte [*pt] = ~1,8 mm *DTO-Punkte / 1 pt = 0,35 27 mm Abmessungen – Dimension [mm] B = 50,0 +2 H = 21,0 +2 R = 1,0 ±0,2 Material: self-adhesive polyester security film, 60 μm Color: silver, matt coated Adhesive: Permanent adhesive Temperature range: -40 ° C to +150 ° C Characteristics: weather resistant, sea water, resistant to many solvents, weak acids and alkalis Labels for Model T40S7, T40S8, T40S9 Model: T40S7 FCC ID: 2ADAT-T40S7TOS9 IC: 12438A-T40S7TOS9 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Model: T40S8 FCC ID: 2ADAT-T40S7TOS9 IC: 12438A-T40S7TOS9 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Model: T40S9 FCC ID: 2ADAT-T40S7TOS9 IC: 12438A-T40S7TOS9 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Managing Director: Andreas Hüllhorst – Chairman of the Board: Eoghan O’Lionaird Registered at Darmstadt HRB 1147 HBM: public Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45 D-64293 Darmstadt Tel. +49 6151 803-0 Fax +49 6151 803-9100 www.hbm.com Internal Photos T40 Rotor Front Rear S7 - S9 Managing Director: Andreas Hüllhorst – Chairman of the Board: Eoghan O’Lionaird Registered at Darmstadt HRB 1147 HBM: public Stator Front S7 - S9 Rear S7 – S9
The test result refers exclusively to the tested model. This test report may not be copied or published in a part without the written authorization of the accreditation agency and/or EMV TESTHAUS GmbH Revision: 1.0 Customer: Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45 64293 Darmstadt Tel.: +49 6151-803-8030 Fax: +49 6151-803-9100 RF test report 140714-AU01+W01 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7 T40S8 T40S9 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.0 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7, T40S8, T40S9 140714-AU01+W01 Page 2 of 74 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Tel.: +49 9421 56868-0 Fax: +49 9421 56868-100 Email: [email protected] Accreditation: FCC facility registration number: 221458 Test Firm Type “2.948 listed”: Valid until 2017-04-22 Test Firm Type “accredited”: Valid until 2015-06-11 MRA US-EU, FCC designation number: DE0010 BnetzA-CAB-02/21-02/04 Valid until 2018-11-27 Industry Canada test site number: 3472A-1 Registration expiry date: 2015-10-02 Test Laboratory: EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany The technical accuracy is guaranteed through the quality management of the EMV TESTHAUS GmbH EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.0 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7, T40S8, T40S9 140714-AU01+W01 Page 3 of 74 Table of contents 1 Test regulations ................................................................................................................... 7 1.1 Summary of test results ................................................................................................ 7 2 Equipment under Test (EUT) ............................................................................................... 8 2.1 Photo documentation ................................................................................................... 9 2.2 Short description of the EUT ........................................................................................ 9 2.3 Operation mode ........................................................................................................... 9 2.4 Configuration .............................................................................................................. 10 2.5 Used cables ............................................................................................................... 10 3 AC power line conducted emissions .................................................................................. 11 3.1 Test location ............................................................................................................... 11 3.2 Test instruments ......................................................................................................... 11 3.3 Limits ......................................................................................................................... 11 3.4 Test procedure ........................................................................................................... 12 3.5 Test setup .................................................................................................................. 12 3.6 Test results - T40S7 ................................................................................................... 13 3.7 Test results - T40S8 ................................................................................................... 17 3.8 Test results - T40S9 ................................................................................................... 21 4 Radiated emission measurement (<1 GHz) ....................................................................... 25 4.1 Test Location.............................................................................................................. 25 4.2 Test instruments ......................................................................................................... 25 4.3 Limits ......................................................................................................................... 26 4.4 Test procedure ........................................................................................................... 27 4.5 Test setup .................................................................................................................. 28 4.6 Test deviation ............................................................................................................. 28 4.7 Test results - T40S7 ................................................................................................... 29 4.8 Test results - T40S8 ................................................................................................... 38 4.9 Test results - T40S9 ................................................................................................... 47 5 Radiated emission measurement (>1 GHz) ....................................................................... 56 6 Bandwidths ........................................................................................................................ 57 6.1 Test Location.............................................................................................................. 57 6.2 Test instruments ......................................................................................................... 57 6.3 Limits ......................................................................................................................... 57 6.4 Test setup .................................................................................................................. 57 6.5 Test deviation ............................................................................................................. 57 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.0 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7, T40S8, T40S9…
Text truncated - open the document above for the full version.
EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7, T40S8, T40S9 140714-AU01+W01 Annex A Page 1 of 13 1 Annex A – Test setup 1.1 List of Pictures Picture 1: T40S7 test setup radiated emission test 9kHz - 30MHz (front view) ................. 2 Picture 2: T40S7 test setup radiated emission test 9kHz - 30MHz (rear view) .................. 2 Picture 3: T40S7 test setup radiated emission test 30MHz - 1GHz, CDC ......................... 3 Picture 4: T40S7 test setup radiated emission test 30MHz - 1GHz, OATS (front view) ..... 3 Picture 5: T40S7 test setup radiated emission test 30MHz - 1GHz, OATS (rear view) ..... 4 Picture 6: T40S7 test setup with magnetic field probe ....................................................... 4 Picture 7: T40S7 test setup conducted emission test (front view) ..................................... 5 Picture 8: T40S7 test setup conducted emission test (rear view) ...................................... 5 Picture 9: T40S8 test setup radiated emission test 9kHz - 30MHz (front view) ................. 6 Picture 10: T40S8 test setup radiated emission test 9kHz - 30MHz (rear view) ................ 6 Picture 11: T40S8 test setup radiated emission test 30MHz - 1GHz, CDC ....................... 7 Picture 12: T40S8 test setup radiated emission test 30MHz - 1GHz, OATS (front view) ... 7 Picture 13: T40S8 test setup radiated emission test 30MHz - 1GHz, OATS (rear view) ... 8 Picture 14: T40S8 test setup with magnetic field probe ..................................................... 8 Picture 15: T40S8 test setup conducted emission test (front view) ................................... 9 Picture 16: T40S8 test setup conducted emission test (rear view) .................................... 9 Picture 17: T40S9 test setup radiated emission test 9kHz - 30MHz (front view) ............... 10 Picture 18: T40S9 test setup radiated emission test 9kHz - 30MHz (rear view) ................ 10 Picture 19: T40S9 test setup radiated emission test 30MHz - 1GHz, CDC ....................... 11 Picture 20: T40S9 test setup radiated emission test 30MHz - 1GHz, OATS (front view) ... 11 Picture 21: T40S9 test setup radiated emission test 30MHz - 1GHz, OATS (rear view) ... 12 Picture 22: T40S9 test setup with magnetic field probe ..................................................... 12 Picture 23: T40S9 test setup conducted emission test (front view) ................................... 13 Picture 24: T40S9 test setup conducted emission test (rear view) .................................... 13 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7, T40S8, T40S9 140714-AU01+W01 Annex A Page 2 of 13 1.2 Test setup T40S7 Picture 1: T40S7 test setup radiated emission test 9kHz - 30MHz (front view) Picture 2: T40S7 test setup radiated emission test 9kHz - 30MHz (rear view) EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7, T40S8, T40S9 140714-AU01+W01 Annex A Page 3 of 13 Picture 3: T40S7 test setup radiated emission test 30MHz - 1GHz, CDC Picture 4: T40S7 test setup radiated emission test 30MHz - 1GHz, OATS (front view) EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7, T40S8, T40S9 140714-AU01+W01 Annex A Page 4 of 13 Picture 5: T40S7 test setup radiated emission test 30MHz - 1GHz, OATS (rear view) Picture 6: T40S7 test setup with magnetic field probe EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7, T40S8, T40S9 140714-AU01+W01 Annex A Page 5 of 13 Picture 7: T40S7 test setup conducted emission test (front view) Picture 8: T40S7 test setup conducted emission test (rear view) EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7, T40S8, T40S9 140714-AU01+W01 Annex A Page 6 of 13 1.3 Test setup T40S8 Picture 9: T40S8 test setup radiated emission test 9kHz - 30MHz (front view) Picture 10: T40S8 test setup radiated emission test 9kHz - 30MHz (rear view) EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7, T40S8, T40S9 140714-AU01+W01 Annex A Page 7 of 13 Picture 11: T40S8 test setup radiated emission test 30MHz - 1GHz, CDC Picture 12: T40S8 test setup radiated emission test 30MHz - 1GHz, OATS (front view) EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7, T40S8, T40S9 140714-AU01+W01 Annex A Page 8 of 13 Picture 13: T40S8 test setup radiated emission test 30MHz - 1GHz, OATS (rear view) Picture 14: T40S8 test setup with magnetic field probe EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7, T40S8, T40S9 140714-AU01+W01 Annex A Page 9 of 13 Picture 15: T40S8 test setup conducted emission test (front view) Picture 16: T40S8 test setup conducted emission test (rear view) EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7, T40S8, T40S9 140714-AU01+W01 Annex A Page 10 of 13 1.4 Test setup T40S9 Picture 17: T40S9 test setup radiated emission test 9kHz - 30MHz (front view) Picture 18: T40S9 test setup radiated emission test 9kHz - 30MHz (rear view) EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.7 Hottinger Baldwin Messtechnik GmbH Torque meter T40S7, T40S8, T40S9 140714-AU01+W01 Annex A Page 11 of 13 Picture 19: T40S9 test setup radiated emission test 30MHz - 1GHz, CDC Picture 20: T40S9 test setup radiated emission test 30MHz - 1GHz, OATS (front view) EMV TESTHAUS GmbH Gustav-Hertz-Straß…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 1.22 MHz - 1.22 MHz | - |

TJ1S8-2K Torquemeter
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
TCAS4 Torquemeter
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
T40 Torquemeter
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
TJ1S6 Torquemeter
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
T10-S2TOS6 Torquemeter
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter