FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Royqueen Audio Technology Co., Ltd./
  3. 2ADOR-G700B

2ADOR-G700BBluetooth Speaker

Shenzhen Royqueen Audio Technology Co., Ltd.
Bluetooth Speaker - FCC ID 2ADOR-G700B - Shenzhen Royqueen Audio Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Aug 13, 2022
Application Purpose
Original Equipment
Date of Application
Aug 11, 2022
Equipment Note
Bluetooth Speaker
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Royqueen Audio Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Modeldifferencedeclarationletter DifferencesDescription WeShenzhenRoyqueenAudioTechnologyCo.,Ltd.state: Product: BluetoothSpeaker ModelName : G700B,G700 Theaboveproductwithsamecircuit,PCBlayout,electricalparts,materialsandwiring structures,thematerialsofdecorativeaccessoriesissame,Fortheproductappearance difference,thesizeisthesame,butthecoloroftheproductisdifferent Signatory Date:08-09.2022 <Signature> Name : fengyan Title : DevelopmentManager Company : ShenzhenRoyqueenAudioTechnologyCo.,Ltd. Address:The2ndFloor,ShenhuiIndustrialPark,No.1010BulongRoad,LonghuaNewDistrict Shenzhen

Cover Letter(s)

C5266091_X8_Ed.1 1/1 ShenzhenRoyqueenAudioTechnologyCo.,Ltd. LetterofAuthorization Company:ShenzhenRoyqueenAudioTechnologyCo.,Ltd. Address:The2ndFloor,ShenhuiIndustrialPark,No.1010BulongRoad,LonghuaNewDistrict Shenzhen ProductName:BluetoothSpeaker ModelNumber:G700B,G700 FCCIdentifier:2ADOR-G700B WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:fengyanDate:August9,2022 Title:DevelopmentManager Signatureofapplicant:

Cover Letter(s)

C5266091_X10_Ed.2 1/1 ShenzhenRoyqueenAudioTechnologyCo.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:August9,2022 Subject:RequestforConfidentiality FCCID:2ADOR-G700B ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality NOTE2 IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo ☐ BlockDiagram ☒☐ Schematics ☒☐ TestReportNoNo TestSetupPhotosNo ☐ User’sManual ☐ NOTE 1 ☐ InternalPhotos ☐ NOTE 1 ☐ PartsList/TuneUp ☐☐ RFExposureInfoNoNo OperationalDescription ☒☐ CoverLetter(s)NoNo SDRSoftware/SecurityInfo ☐ No NOTE1:Long-TermConfidentialitymaybepermittedunderspecialconditions(SeeII.LONG-TERM CONFIDENTIALITY,Section3ofKDB726920,uselastinforce) NOTE2:Short-TermConfidentialitycanberequestedforamaximumof180daysfromthedateofthegrant. Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. C5266091_X10_Ed.2 1/1 Incaseofshort-termConfidentiality,theapplicantrequeststheexhibitsselected abovearewithheldfrompublicviewforaperiodof______daysfromthedateofthe GrantofEquipmentAuthorizationandpriortomarketing. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. Sincerely, Name:fengyanDate:August9,2022 Title:DevelopmentManager Signatureofapplicant:

External Photos

Page1of3ReportNo.:FCS202207161 Externalphotos Photo1 Photo2 Page2of3ReportNo.:FCS202207161 Photo3 Photo4 Page3of3ReportNo.:FCS202207161 Photo5 Photo6

ID Label/Location Info

LabelandLabelLocation  FCCID:2ADOR-G700B Blackfontonawhitelabel

Internal Photos

Page1of5ReportNo.:FCS202207161 Internalphotos Photo1 Photo2 Page2of5ReportNo.:FCS202207161 Photo3 Photo4 Page3of5ReportNo.:FCS202207161 Photo5 Photo6 PCBANTENNA Page4of5ReportNo.:FCS202207161 Photo7 Photo8 Page5of5ReportNo.:FCS202207161 Photo9

RF Exposure Info

Page1of2ReportNo.:FCS202105032W02 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com FCCRFExposure EUTDescription:BluetoothSpeaker ModelNo.:G700B FCCID:2ADOR-G700B Equipmenttype:fixedequipment 1.Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactof humanexposuretoradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) F=frequencyinMHz Formula:Pd=(Pout*G)/(4*π*r 2 ) Where: Pd=powerdensityinmW/cm 2 , Pout=outputpowertoantennainmW; G=gainofantennainlinearscale, π=3.14; R=distancebetweenobservationpointandcenteroftheradiatorincm PdidthelimitofMPE,1mW/cm2.Ifweknowthemaximumgainoftheantennaandthetotal powerinputtotheantenna,throughthecalculation,wewillknowthedistancerwheretheMPE limitisreached. 2.TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleand highestchannelindividually. Page2of2ReportNo.:FCS202105032W02 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com 3.TestResultofRFExposureEvaluation Modulation Channel Freq. (MHz) Conduct edpower (dBm) Max tune-up power (mW) Antenna Gain (dBi) Antenna gainnumeric Evaluation result (mW/cm2) Power density Limits (mW/cm2) GFSK 24022.433 1.75 1.01.260.000441 2441 2.34 1.71 1.01.260.000431 2480 2.412 1.74 1.01.260.000431 Conclusion:themaxresult:0.00044≤1.0compliancewithFCC'sRFExposure.

Test Report

FCCTestReport ReportNo:FCS202207161W01 Issuedfor Applicant: ShenzhenRoyqueenAudioTechnologyCo.,Ltd. Address: The2ndFloor,ShenhuiIndustrialPark,No.1010Bulong Road,LonghuaNewDistrictShenzhen ProductName: BluetoothSpeaker BrandName: ROYQUEEN ModelName: G700B SeriesModel: G700 FCCID: 2ADOR-G700B IssuedBy:FluxComplianceServiceLaboratory Add:Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-Tech Industrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com Page 2 of47ReportNo.:FCS202207161W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com TESTRESULTCERTIFICATION Applicant’sName......................:ShenzhenRoyqueenAudioTechnologyCo.,Ltd. Address......................................: The2ndFloor,ShenhuiIndustrialPark,No.1010Bulong Road,LonghuaNewDistrictShenzhen Manufacture'sName................:ShenzhenRoyqueenAudioTechnologyCo.,Ltd. Address......................................: The2ndFloor,ShenhuiIndustrialPark,No.1010Bulong Road,LonghuaNewDistrictShenzhen ProductDescription ProductName...........................:BluetoothSpeaker BrandName ............................... :ROYQUEEN ModelName..............................:G700B SeriesModel .............................. :G700 TestStandards..........................:FCCRulesandRegulationsPart15SubpartC,Section247 TestProcedure .......................... :ANSIC63.10:2013 ThisdevicedescribedabovehasbeentestedbyFluxComplianceServiceLaboratory,thetestresults showthattheequipmentundertest(EUT)isincompliancewiththeFCCrequirements.Anditis applicableonlytothetestedsampleidentifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofFluxCompliance ServiceLaboratory,thisdocumentmaybealteredorrevisedbyFluxComplianceServiceLaboratory, personalonly,andshallbenotedintherevisionofthedocument.. DateofTest .................................. : Date(s)ofperformanceoftests . :July25,2022~July27,2022 DateofIssue.................................:July27,2022 TestResult....................................:Pass Testedby: (ScottShen) Reviewedby : (DukeQian) Approvedby: (JackWang) Page 3 of47ReportNo.:FCS202207161W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com TableofContentsPage 1.SUMMARYOFTESTRESULTS..............................................................................................6 1.1TESTFACTORY................................................................................................................7 1.2MEASUREMENTUNCERTAINTY....................................................................................7 2.GENERALINFORMATION......................................................................................................8 2.1GENERALDESCRIPTIONOFTHEEUT.........................................................................8 2.2BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED.............10 2.3DESCRIPTIONOFNECESSARYACCESSORIESANDSUPPORTUNITS................11 2.4EQUIPMENTSLIST.........................................................................................................12 3CONDUCTEDEMISSIONMEASUREMENT..........................................................................13 4.20DBBANDWIDTH...............................................................................................................17 4.1Limit..................................................................................................................................17 4.2TestProcedure.................................................................................................................17 4.3Testsetup.........................................................................................................................17 4.4Testresults.......................................................................................................................17 4.5OriginalTestData............................................................................................................18 5.CONDUCTEDOUTPUTPOWER...........................................................................................20 5.1LIMIT................................................................................................................................20 §§............................................................................................................................................20 5.3TESTSETUP...................................................................................................................20 5.5TESTRESULTS..............................................................................................................20 6NUMBEROFHOPPINGCHANNEL.......................................................................................23 6.1LIMIT................................................................................................................................23 6.2TESTPROCEDURE........................................................................................................23 5.3TESTSETUP...................................................................................................................23 6.4EUTOPERATIONCONDITIONS....................................................................................23 6.5TESTRESULTS..............................................................................................................24 7.BANDEDGEANDSPURIOUS(CONDUCTED)....................................................................25 7.1LIMIT................................................................................................................................25 7.2TESTPROCEDURE........................................................................................................25 7.3T…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of2ReportNo.:FCS202207161 Blow1GHzforradiatedemissiontestsetup Above1GHzforradiatedemissiontestsetup Page 2 of2ReportNo.:FCS202207161 Conductedemissiontestsetup

Contact Information

Applicant

feng yan(Development Manager)
[email protected]13538218145Fax: 13538218145

Technical Contact

Flux Compliance Service LaboratoryAndy yue
[email protected]86-769-27280901

Dongguan · China

Non-Technical Contact

Flux Compliance Service LaboratoryAndy yue
[email protected]86-769-27280901

Test Firm

Flux Compliance Service LaboratoryAndy Yue
[email protected]13510297284

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.75 mW
Confidentiality
Long Term
Grant Notes
Output power listed isconducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Other Applications from Shenzhen Royqueen Audio Technology Co., Ltd.

Bluetooth Speaker - FCC ID 2ADOR-G180 - Shenzhen Royqueen Audio Technology Co., Ltd.
2ADOR-G180

Bluetooth Speaker

Sep 24, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Bluetooth speaker - FCC ID 2ADORT900 - Shenzhen Royqueen Audio Technology Co., Ltd.
2ADORT900

Bluetooth speaker

Jul 28, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Bluetooth Speaker - FCC ID 2ADORT700 - Shenzhen Royqueen Audio Technology Co., Ltd.
2ADORT700

Bluetooth Speaker

Jul 14, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
SPEAKERPHONE - FCC ID 2ADORT300B - Shenzhen Royqueen Audio Technology Co., Ltd.
2ADORT300B

SPEAKERPHONE

Apr 29, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Bluetooth speaker - FCC ID 2ADORRQT600 - Shenzhen Royqueen Audio Technology Co., Ltd.
2ADORRQT600

Bluetooth speaker

Jan 14, 2015

Equipment Class

DTS - Digital Transmission System