FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Eski Inc./
  3. 2ADS4101-00070

2ADS4101-00070Clip 3

Eski Inc.
Clip 3 - FCC ID 2ADS4101-00070 - Eski Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 13, 2021
Application Purpose
Original Equipment
Date of Application
Apr 13, 2021
Equipment Note
Clip 3
Frequency Range
2402.00000000 - 2480.00000000
Company
Eski Inc.
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

CLIP 3 USER MANUAL M odel No: 101-00070 Date: 11/18/2020 Contents General Information ..................................................................................................................................... 1 User Guide .................................................................................................................................................... 2 Safety ............................................................................................................................................................ 3 1 General Information To address the employers’ concerns in the current times of pandemic, Safeteams introduced a series of “Clip” devices. Lightweight and simple wearables were specifically designed to deliver social distancing and contact tracing features. Clip 2 constitutes an upgraded version of clip 1.2. It comes with a long-lasting rechargeable battery, better precision in contact tracing and a vibration feature as an additional alert. 2 User Guide 1. Please make sure the device is sufficiently charged. 2. If is charging, please unplug the device from the charger or the charging station and put it on at your preference. Note, to work properly, the device must be on you for the entire duration of your workday. 3. Note, when violating social distancing the device will alert you with the red light and a vibration. In this event, please move to a safe distance from your closet co- worker (2 m) and the alert will stop. 4. Upon the end of your workday, please return the device to its storing place. 5. Connect the device to the charger or place it on the charging station if necessary. 6. Make sure to read the safety instructions on the next page. 3 Safety 1. Note, the device is not water resistant. 2. Do not attempt to open the device. 3. Use only the original charging station or a proper charging cable (Micro USB Type B) for charging. FCCCaution Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothe followingtwoconditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2) thisdevicemustacceptanyinterferencereceived,includinginterferencethatmay causeundesiredoperation. AnyChangesormodificationsnotexpresslyapprovedbythepartyresponsiblefor compliance couldvoidtheuser'sauthoritytooperatetheequipment. Note:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClass Bdigitaldevice,pursuanttopart15oftheFCCRules.Theselimitsaredesignedto providereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation. Thisequipmentgeneratesusesandcanradiateradiofrequencyenergyand,ifnot installedandusedinaccordancewiththeinstructions,maycauseharmfulinterference toradiocommunications.However,thereisnoguaranteethatinterferencewillnot occurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferenceto radioortelevisionreception,whichcanbedeterminedbyturningtheequipmentoff andon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthe followingmeasures: -R eorientorrelocatethereceivingantenna. -Increasetheseparationbetweentheequipmentandreceiver. -C onnecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthe receiverisconnected. -C onsultthedealeroranexperiencedradio/TVtechnicianforhelp.

Cover Letter(s)

C5266091_X8_Ed.1 Letter of Authorization Eski Inc. Company: Eski Inc. Address: 103 Rue de Louvain O, Montréal, QC H2N 1A3 Product Name: Clip 3 Model Number: 101-00070 FCC Identifier: 2AXBP101-00070 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Vladimir Grach Date: Feb.19.2021 Title: Hardware Developer Signature of applicant: 1/1

Cover Letter(s)

C5266091_X10_Ed.2 Eski Inc. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: Feb.19 .2021 Subject: Request for Confidentiality FCC ID: 2ADS4101-00070 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ______ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. 1/1 C5266091_X10_Ed.2 Sincerely, Signature: Name: Vladimir Grach Title: Hardware Developer 1/1

External Photos

External Photos FCC ID: 2ADS4101-00070

ID Label/Location Info

Label Location Model: 101-00070 FCC-ID: 2ADS4101-00070

Internal Photos

Internal Photos ANT FCC ID: 2ADS4101-00070 TLSR8251ET32 SR1020

RF Exposure Info

Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Page 1 of 37 TEST REPORT Reference No. .................... : FCC ID ................................ : Applicant ........................... : Address ............................. : Product Name ................... : Test Model. ........................ : Standards .......................... : Date of Receipt sample .... : Date of Test........................ : Date of Issue ..................... : Test Result ......................... : WTX21X03024089W 2ADS4101-00070 Eski Inc. 103 Rue de Louvain O, Montréal, QC H2N 1A3 Clip3 101-00070 FCC Part 2.1093, ANSI / IEEE C95.1 :2005+A1:2010 ANSI / IEEE C95.3 :2002(R2008) Mar.26, 2021 Mar.26, 2021 to Apr.12, 2021 Apr.13, 2021 Pass Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Testing Group (Shenzhen) Co., Ltd. Address: 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70 Bao'an District, Shenzhen, Guangdong, China Tel.: +86-755-33663308 Fax.: +86-755-33663309 Tested by: Reviewed By: Approved & Authorized By: Hubrey Cai / Project Engineer Lion Cai / RF Manager Silin Chen / Manager Reference No.: WTX21X03024089W Page 2 of 37 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn TABLE OF CONTENTS 1. General Information ................................................................................................................................................... 3 1.1 Product Description for Equipment Under Test (EUT) ......................................................................................... 3 1.2 Test Standards .................................................................................................................................................... 4 1.3 Test Methodology ................................................................................................................................................ 4 1.4 Test Facility ......................................................................................................................................................... 4 2. Summary of Test Results .......................................................................................................................................... 5 3. Specific Absorption Rate (SAR) ................................................................................................................................ 6 3.1 Introduction .......................................................................................................................................................... 6 3.2 SAR Definition ..................................................................................................................................................... 6 4. SAR Measurement System ........................................................................................................................................ 7 4.1 The Measurement System .................................................................................................................................. 7 4.2 Probe ................................................................................................................................................................... 7 4.3 Probe Calibration Process ................................................................................................................................. 10 4.4 Phantom ............................................................................................................................................................ 11 4.5 Device Holder .................................................................................................................................................... 11 4.6 Test Equipment List ........................................................................................................................................... 12 5. Tissue Simulating Liquids ....................................................................................................................................... 13 5.1 Composition of Tissue Simulating Liquid ........................................................................................................... 13 5.2 Tissue Dielectric Parameters for Head and Body Phantoms ............................................................................. 14 5.3 Tissue Calibration Result ................................................................................................................................... 15 6. SAR Measurement Evaluation ................................................................................................................................ 16 6.1 Purpose of System Performance Check ............................................................................................................ 16 6.2 System Setup .................................................................................................................................................... 16 6.3 Validation Results .............................................................................................................................................. 18 7. EUT Testing Position ............................................................................................................................................... 19 7.1 EUT Antenna Position ....................................................................................................................................... 19 7.2 EUT Testing Position ........................................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB210106023RFX TEST REPORT Compiled by: Reviewed by: Approved by: Arron Liu Bin Mei Rita Xiao / Director The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen CTB Testing Technology Co., Ltd. this report can’t be reproduced except in full. The tested sample(s) and the sample information are provided by the client. Product Name: Clip 3 FCC ID: 2ADS4101-00070 Trademark: Safeteams Model Number: 101-00070 Prepared For: Eski Inc. Address: 103 Rue de Louvain O, Montréal, QC H2N 1A3 Manufacturer: Inspi Technology Co., Ltd. Address: Room 703/726, HuaFeng Yu'An Business Building, District 45 of Ban'An , Shenzhen, China . 2nd Floor, A, building 1, Wanfeng Huafeng Chuangye Park, Heyi Shequ, Shajing street, Baoan District, Shenzhen, China . Prepared By: Shenzhen CTB Testing Technology Co., Ltd. Address: Floor 1&2, Building A, No. 26 of Xinhe Road, Xinqiao Street, Baoan District, Shenzhen, China Sample Received Date: Jan. 6, 2021 Sample tested Date: Jan. 6, 2021 to Jan. 29, 2021 Issue Date: Jan. 29, 2021 Report No.: CTB210106023RFX Test Standards FCC Part15.247 ANSI C63.10:2013 Test Results PASS Remark: This is Bluetooth radio test report. Report Tel: 4008-707-283Web: http://www.ctb-lab.netPage 1 of 37 Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB210106023RFX TABLE OF CONTENT Test Report Declaration Page 1. VERSION ...................................................................................................... 4 2. TEST SUMMARY ........................................................................................... 5 3. MEASUREMENT UNCERTAINTY .................................................................. 6 4. PRODUCT INFORMATION AND TEST SETUP ............................................... 7 4.1 Product Information ............................................................................................. 7 4.2 Test Setup Configuration ..................................................................................... 7 4.3 Support Equipment .............................................................................................. 7 4.4 Channel List ........................................................................................................ 8 4.5 Test Mode ........................................................................................................... 8 4.6 Test Environment ................................................................................................ 8 5. TEST FACILITY AND TEST INSTRUMENT USED .......................................... 9 5.1 Test Facility ......................................................................................................... 9 5.2 Test Instrument Used .......................................................................................... 9 6. AC POWER LINE CONDUCTED EMISSION ................................................... 11 6.1 Block Diagram Of Test Setup ............................................................................ 11 6.2 Limit ................................................................................................................... 11 6.3 Test procedure .................................................................................................. 11 6.4 Test Result ........................................................................................................ 13 7. RADIATED SPURIOUS EMISSION............................................................... 15 7.1 Block Diagram Of Test Setup ............................................................................ 15 7.2 Limit ................................................................................................................... 15 7.3 Test procedure .................................................................................................. 16 7.4 Test Result ........................................................................................................ 17 8. BAND EDGE AND RF COUNDUCTED SPURIOUS EMISSIONS ................... 24 8.1 Block Diagram Of Test Setup ............................................................................ 24 8.2 Limit ................................................................................................................... 24 8.3 Test procedure .................................................................................................. 24 8.4 Test Result ........................................................................................................ 25 9. COUDUCTED OUTPUT POWER .................................................................. 27 9.1 Block Diagram Of Test Setup ............................................................................ 27 Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 37 Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB210106023RFX 9.2 Limit ................................................................................................................... 27 9.3 Test procedure .................................................................................................. 27 9.4 Test Result ........................................................................................................ 28 10. 6DB OCCUPIED BANDWIDTH ..................................................................... 30 10.1 Block Diagram Of Test Setup .......................................................................... 30 10.2 Limit ................................................................................................................. 30 10.3 Test procedure ................................................................................................ 30 10.4 Test Result ...................................................................................................... 30 11. P…

Text truncated - open the document above for the full version.

Test Setup Photos

Radiated Emission Below 1G A bove 1G FCC ID: 2ADS4101-00070 Conducted Emission

Contact Information

Applicant

GACEMI Merwan(Hardware development Team Lead)
[email protected]1(514)-510-5777-261Fax: 1(514)-510-5777-261

Technical Contact

Shenzhen CTB Testing Technology Co., Ltd.Simon Lee
[email protected](86) 13662574496

Shenzhen · China

Non-Technical Contact

Shenzhen CTB Testing Technology Co., Ltd.Simon Lee
[email protected](86) 13662574496

Test Firm

Shenzhen CTB Testing Technology Co., Ltd.Rita Xiao
[email protected]86-13538218145

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz10.01 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. For body operation, this device has been tested and meets FCC RF exposure guidelines when used at a minimum distance of 0mm from the body. The highest reported SAR for body use condition is 0.17 W/kg.

Other Applications from Eski Inc.

NOVA Plus LUXX Plus - FCC ID 2ADS4-LUXXPLUS - Eski Inc.
2ADS4-LUXXPLUS

NOVA Plus LUXX Plus

Apr 16, 2024

Equipment Class

UWB - Ultra Wideband Transmitter
WaveNode (Node RF) - FCC ID 2ADS4-WAVENODE - Eski Inc.
2ADS4-WAVENODE

WaveNode (Node RF)

Oct 20, 2022

Equipment Class

DTS - Digital Transmission System
BLUETOOTH TRANSMITTER / RECEIVER - FCC ID 2ADS4HUB2 - Eski Inc.
2ADS4HUB2

BLUETOOTH TRANSMITTER / RECEIVER

Feb 02, 2020

Equipment Class

DTS - Digital Transmission System
Bluetooth transmitter that controls luminous objects wirelessly from dMX signals - FCC ID 2ADS4BRO1 - Eski Inc.
2ADS4BRO1

Bluetooth transmitter that controls luminous objects wirelessly from dMX signals

Dec 14, 2015

Equipment Class

DTS - Digital Transmission System