PulseOximeter JPD-500F DateofIssue:2020.11,Version:V1.1 FCCStatement ThisdevicecomplieswithPart15oftheFCCRulesOperationissubject tothefollowingtwoconditions: (1)thisdevicemaynotcauseharmfulinterference. (2)thisdevicemustacceptanyinterferencereceived,includinginterferencethat maycauseundesiredoperation. NOTE:Thisequipmenthasbeentestedandfoundtocomplywiththelimits foraClassBdigitaldevice,pursuanttoPart15oftheFCCRules.Theselimits aredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresid entialinstallation.Thisequipmentgenerates,usesandcanradiate radiofrequencyenergyand,ifnotinstalledandusedinaccordance withtheinstructions,maycauseharmfulinterferencetoradiocommunications. However,thereisnoguaranteethatinterferencewillnotoccurinaparticular installation.Ifthisequipmentdoescauseharmfulinterferencetoradioor televisionreception,whichcanbedeterminedbyturningtheequipmentoff andon,theuserisencouragedtotrytocorrecttheinterferencebyoneormore ofthefollowingmeasures: ●Reorientorrelocatethereceivingantenna. ●Increasetheseparationbetweentheequipmentandreceiver. ●Connecttheequipmentintoanoutletonacircuitdifferentfromthatto whichthereceiverisconnected. ●Consultthedealeroranexperiencedradio/TVtechnicianforhelp. Warning:Changesormodificationstothisunitnotexpresslyapprovedbythe partyresponsibleforcompliancecouldvoidtheuser’sauthoritytooperate theequipment. Precautions DonotattempttomaintaintheOximeterunlessyouareprofessional engineers.Onlyprofessionalswithmaintenancequalificationareallowedto performinteriormaintenanceasnecessary. PeriodicallychangethecontactpositionbetweentheOximeterprobeandthe fingerforameasurementthatlastsalongtime.Adjustthepositionofthe probebeforethemeasurementlaststwohours,andchecktheintegrityofskin, thebloodcirculationconditionofthefingeraswellasthepositionofthe finger. Thisproductisnotapplicabletotheexaminationofnewbornbabies. Seekformedicalcareintimeifthemeasuredvaluegoesbeyondthenormal rangewhileyouaresurethattheinstrumentdoesnotmalfunction. Donotdirectlyexposeyoureyestolight-emittingcomponentsofthe Oximeter,asthatcouldcauseharmtoyoureyes. Fordetailsaboutclinicallimitationsandcontraindications,pleasecarefully consultrelevantmedicalliteratures. Thefollowingfactorsmaycausedisturbancetooraffecttheaccuracyof examination: ◆ Thisproductisusedinanenvironmentinvolvinghigh-frequencydevices, suchashigh-frequencyelectricknivesandCTapparatuses. ◆TheprobeoftheOximeterisplacedonthesamebodypartorlimbaswith bloodpressurecuffarterialductorintravenousinjection. ◆ Theusersuffersfromhypotension,severevascularatrophy,severeanemia, orlowoxygen. ◆ Theuserisinsuddencardiacarrestorshockstate. ◆Thefingerwithnailpolishorafakefingernailmaycausewrongreadingsof pulseoxygensaturation. Warnings Warning:DonotusetheOximeterinanenvironmentwithanyinflammablegases, inflammableanesthetic,orotherinflammablesubstances. Warning:Donotattempttochargeanycommondrybattery,asthatcouldcauseleakage, firedisaster,orevenexplosion.Disposeofexhaustedbatteriesinaccordancewith environmentprotectionregulations. Warning:DonotusetheOximeterinanMRIorCTenvironment. Warning:DonotoperatetheOximeterwhenitisdampwithoverfloworwatervapor condensation.AvoidmovingtheOximeterfromanexcessively-coldenvironmenttoa high-temperaturemoistenvironment. ProductAccessories 1.Onehangingrope; 2.storagebag; 3.TwoAAAbatteries 4.Oneusermanual 5.OneJUMPERHealth(app)usermanual SymbolConventions SymbolDescription BF-typeapplicationpart Caution:Pleaseseethismanual. %SpO2 Symbolofoxygensaturation bpmPR Symbolofpulserate NoSPO2alarms. Consulttheinstructionsforuse. IP22 Thedegreeofprotectionagainstharmfulingressofwaterand particulatematter Whenendusersabandonthisproduct,theymustsendtheproductto thecollectionplaceforrecycling. CEMark:TheProductsystemconformstoessentialrequirementsof theMedicalDeviceDirective93/42/EEC. Overview Oxygensaturationisthepercentageofoxyhemoglobin(HbO2)thatiscombinedwith oxygenagainstallcombinablehemoglobin(Hb).Itisanimportantphysiological parameterinvolvedinrespirationandcirculation.Theoxygensaturationofarterialblood inanormalhumanbodyis98%.Oxygensaturationisanimportantindicatoroftheoxygen conditioninthehumanbody.Ingeneral,thenormalvaluesofoxygensaturationshallnot belowerthan94%.Ifthemeasuredvalueofoxygensaturationislowerthan94%,an insufficientsupplyofoxygenisconsidered. Thepulserateisthenumberofpulsebeatsperminute.Normally,thepulserateis consistentwiththeheartrate.Ingeneral,thepulserateofeverypeopleis60to90beats perminute. ThePerfusionIndex(PI)usuallyreflectsthelimbperfusionstatusofanexaminedpatient, andshowsthedetectionprecisionoftheinstrumentaswell;thatis,examinationcanstill beperformedevenintheloworweakperfusioncondition.ThePIofanormalhumanbody is0.3%orgreater. WorkingPrinciples,ExpectedUsage,andApplicableScope Basedonfulldigitaltechnology,theFingerPulseOximeternon-invasivelymeasuresthe actualcontent(oxygensaturation)ofoxyhemoglobin(HbO2)inarterialbloodusingthe opticaltransmittancemethod. TheFingerPulseOximetermeasuresthebloodoxygensaturationandpulserateofa humanbodyviafingerartery.Itisapplicabletoawiderangeoffields,suchasfamilies, clinics.Usethisinstrumentformeasurementbeforeoraftersports.Youarenotadvisedto usethisinstrumentduringsportsactivities.Donotuseitforcontinuouscareforpatients. AppearanceofStructure ScreenDisplay ThefollowingfigureshowstheinformationdisplayontheOLEDscreenoftheOximeter innormaldetectionstate: Note:Batterypowerindicationandbluetoothsymbolwillalternatelydisplayed. Power-OnButton/FunctionalButtonOperations AfterpoweringontheOximeter,holdthepower-onButton/functionalbuttonforaboutone second.TheOximetershowsaparametersettinginterface.Pressorholdthe power-on/functionalbuttontoperformcorrespondingoperations.Holdittosetanitem,or pressittoswitchanoption.Pressmeansnomorethan0.5seconds,whileHoldmeans morethan0.5seconds. AlertSoundSetting Holdthepower-onbutton/functionalbuttonwhiletheOximeterisinpowered-onstate. Parametersettinginterface1isdisplayed,asshowninthefollowingfigure.Move"*"to thecorrespondingoption,…
Text truncated - open the document above for the full version.
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 5 External Photos for SZEM2012012267CR FCC ID: 2ADYL-500F501F SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 5 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 5 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 5 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 5 of 5
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 4 Internal Photos for SZEM2012012267CR FCC ID: 2ADYL-500F501F SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 4 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 4 Antenna SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 4
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201226702 Page: 1 of 6 Keny Xu EMC Laboratory Manager 1 Cover page SAR Evaluation Report Application No.: SZEM2012012267CR Applicant: Shenzhen Jumper Medical Equipment Co., Ltd. Address of Applicant: D Building, No. 71, Xintian Road, Fuyong Street, Baoan, Shenzhen, Guangdong, China Manufacturer: Shenzhen Jumper Medical Equipment Co., Ltd. Address of Manufacturer: D Building, No. 71, Xintian Road, Fuyong Street, Baoan, Shenzhen, Guangdong, China Factory: Shenzhen Jumper Medical Equipment Co., Ltd. Address of Factory: D Building, No. 71, Xintian Road, Fuyong Street, Baoan, Shenzhen, Guangdong, China Equipment Under Test (EUT): EUT Name: Pulse Oximeter Model No.: JPD-500F, JPD-501F Please refer to section 4 of this report which indicates which model was actually tested and which were electrically identical. FCC ID: 2ADYL-500F501F Standards: 47 CFR Part 1.1307 47 CFR Part 2.1093 KDB447498D01 General RF Exposure Guidance v06 Date of Receipt: 2020-12-01 Date of Test: 2020-12-01 to 2020-12-14 Date of Issue: 2020-12-14 Test Result : Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201226702 Page: 2 of 6 2 Version Revision Record Version Chapter Date Modifier Remark 01 2020-12-14 Original Authorized for issue by: Damon Su/Project Engineer Eric Fu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201226702 Page: 3 of 6 3 Contents Page 1 COVER PAGE .............................................................................................................................................. 1 2 VERSION ...................................................................................................................................................... 2 3 CONTENTS .................................................................................................................................................. 3 4 GENERAL INFORMATION .......................................................................................................................... 4 4.1 GENERAL DESCRIPTION OF EUT ............................................................................................................. 4 4.2 TEST LOCATION ...................................................................................................................................... 5 4.3 TEST FACILITY ........................................................................................................................................ 5 4.4 DEVIATION FROM STANDARDS ................................................................................................................. 5 4.5 ABNORMALITIES FROM STANDARD CONDITIONS ....................................................................................... 5 4.6 OTHER INFORMATION REQUESTED BY THE CUSTOMER ............................................................................. 5 5 SAR EVALUATION ...................................................................................................................................... 6 5.1 RF EXPOSURE COMPLIANCE REQUIREMENT ............................................................................................ 6 5.1.1 Standard Requirement ..................................................................................................................... 6 5.1.2 Limits ................................................................................................................................................ 6 5.1.3 EUT RF Exposure ............................................................................................................................ 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201226702 Page: 4 of 6 4 General Information 4.1 General Description of EUT Rated voltage: DC 3V Test voltage: DC 3V Battery: DC 3V by 2*AAA battery Operation Frequency: 2402MHz to 2480MHz Bluetooth Version: V4.1 Modulation Type: GFSK Number of Channels: 40 Channel Spacing: 2MHz Antenna Type: PCB Antenna Antenna Gain: 0dBi Remark: Model No.: JPD-500F, JPD-501F Only the model JPD-501F was tested, since according to the declaration from the applicant, the electrical circuit design, layout, components used, internal wiring and functions were identical for all the above models, with only difference on color, appearance and packaging. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201226702 Page: 5 of 6 4.2 Test Location All tests were performed at: SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong, China 518057 Telephone: +86 (0) 755 2601 2053 Fax: +86 (0) 755 2671 0594 No tests were sub-contracted. 4.3 Test Facility The test facility is recognized, certified, or accredited by the following organizations: • A2LA (Certificate No. 3816.01) SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01. • VCCI The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz, Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have been registered in accordance with the Regulations for Voluntary Control Measures with Registration No.: G-20026, R-14188, C-12383 and T-11153 respectively. • FCC –Designation Number: CN1178 SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized as an accredited testing laboratory. Designation Number: CN1178. Test Firm Registration Number: 406779. • Innovation, Science and Economic Development Canada SGS-…
Text truncated - open the document above for the full version.
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201226701 Page: 1 of 49 Keny Xu EMC Laboratory Manager TEST REPORT Application No.: SZEM2012012267CR Applicant: Shenzhen Jumper Medical Equipment Co., Ltd. Address of Applicant: D Building, No. 71, Xintian Road, Fuyong Street, Baoan, Shenzhen, Guangdong, China Manufacturer: Shenzhen Jumper Medical Equipment Co., Ltd. Address of Manufacturer: D Building, No. 71, Xintian Road, Fuyong Street, Baoan, Shenzhen, Guangdong, China Factory: Shenzhen Jumper Medical Equipment Co., Ltd. Address of Factory: D Building, No. 71, Xintian Road, Fuyong Street, Baoan, Shenzhen, Guangdong, China Equipment Under Test (EUT): EUT Name: Pulse Oximeter Model No.: JPD-500F, JPD-501F Please refer to section 2 of this report which indicates which model was actually tested and which were electrically identical. FCC ID: 2ADYL-500F501F Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2020-12-01 Date of Test: 2020-12-01 to 2020-12-14 Date of Issue: 2020-12-14 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201226701 Page: 2 of 49 Revision Record Version Chapter Date Modifier Remark 01 2020-12-14 Original Authorized for issue by: Damon Su/Project Engineer Eric Fu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201226701 Page: 3 of 49 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Peak Output Power 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.9.1 47 CFR Part 15, Subpart C 15.247(b)(3) Pass Minimum 6dB Bandwidth 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.8.1 47 CFR Part 15, Subpart C 15.247a(2) Pass Power Spectrum Density 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.10.2 47 CFR Part 15, Subpart C 15.247(e) Pass Conducted Band Edges Measurement 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.13.3.2 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.11 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.4,6.5,6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Remark: Model No.: JPD-500F, JPD-501F Only the model JPD-501F was tested, since according to the declaration from the applicant, the electrical circuit design, layout, components used, internal wiring and functions were identical for all the above models, with only difference on color, appearance and packaging. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM201201226701 Page: 4 of 49 3 Contents Page 1 COVER PAGE ............................................................................................................................................ 1 2 TEST SUMMARY ....................................................................................................................................... 3 3 CONTENTS ................................................................................................................................................ 4 4 GENERAL INFORMATION ........................................................................................................................ 6 4.1 DETAILS OF E.U.T. ............................................................................................................................... 6 4.2 DESCRIPTION OF SUPPORT UNITS ......................................................................................................... 6 4.3 MEASUREMENT UNCERTAINTY .............................................................................................................. 6 4.4 TEST LOCATION .................................................................................................................................... 7 4.5 TEST FACILITY ...................................................................................................................................... 7 4.6 DEVIATION FROM STANDARDS ............................................................................................................... 7 4.7 ABNORMALITIES FROM STANDARD CONDITIONS ..................................................................................... 7 5 EQUIPMENT LIST ...................................................................................................................................... 8 6 RADIO SPECTRUM TECHNICAL REQUIREMENT ............................................................................... 11 6.1 ANTENNA REQUIREMENT .................................................................................................................... 11 6.1.1 Test Requirement: ....................................................................................................................... 11 7 RADIO SPECTRUM MATTER TEST RESULTS ..................................................................................... 12 7.1 CONDUCTED PEAK OUTPUT POWER .................................................................................................... 12 7.1.1 E.U.T. Operation .......................................................................................................................... 12 7.1.2 Test Mode Description ................................................................................................................. 12 7.1.3 Test Setup Diagram .................…
Text truncated - open the document above for the full version.
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 3 Setup Photos for SZEM2012012267CR FCC ID: 2ADYL-500F501F SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 3 1 Photographs Radiated Emissions which fall in the restricted bands SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 3 Radiated Spurious Emissions
No.1 Workshop, M-10, Middle Section, · Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 100.00 µW |

Pulse Oximeter
Equipment Class
DTS - Digital Transmission System
Electronic Blood Pressure Monitor
Equipment Class
DTS - Digital Transmission System
Pulse Oximeter
Equipment Class
CXX - Communications Rcvr for use w/ licensed Tx and CBs
Body Fat Scale
Equipment Class
DTS - Digital Transmission System
Weight scale
Equipment Class