Pulse OximeterSPA11 Date of Issue: 2024.03, Version: V3.0 FCC Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. RF warning statement: The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction. FCC ID:2ADYL-SPA11 Precautions Do not attempt to maintain the Oximeter unless you are professional engineers. Only professionals with maintenance qualification are allowed to perform interior maintenance as necessary. Periodically change the contact position between the Oximeter probe and the finger for a measurement. Adjust the position of the probe before the measurement, and check the integrity of skin, blood circulation condition of the finger as well as the position of the finger. This product is not applicable to the examination of newborn babies. Seek for medical care in time if the measured value goes beyond the normal range while you are sure that the instrument does not malfunction. Do not directly expose your eyes to light-emitting components of the Oximeter, as that could cause harm toyour eyes. Do not expose the device to lint, dust, light(including sunlight), pets, pests, or children, etc. This pulse oximeter is not intended to diagnose or treat any medical condition or disease. People who need SpO2 and pulse rate measurements because of a medical condition shouldnot use the oximeter andshould consult with theirphysician. ◆ Do not self diagnose andtreat based on measurement results, please always consult a doctor. For details about clinical limitations and contraindications, please carefully consult relevant medical literatures. It needs more than half an hour to warm or cool from the minimum /maximum storage temperature between uses until it is ready for intended use. Please note the effects of degraded sensors that can degrade performance or cause other problems. The patient is an intended operator. The lay operator or lay responsible organization should contact the manufacturer or manufacturer's representative on the followingissues: ◆Assistance in settingup, using, or maintainingthe equipment or system when needed. ◆ To report unexpected operation or events. The followingfactors may cause disturbance toor affect the accuracy of examination: ◆This product is used in an environment involving high-frequency devices, such as high-frequency electric knives andCT apparatuses. ◆ The probe of the Oximeter is placed on the same body part or limb as with blood pressure cuff arterial duct or intravenous injection. ◆ The user suffers from hypotension, severe vascular atrophy, severe anemia, or low oxygen. ◆The user is in sudden cardiac arrest or shock state. ◆ The finger with nail polish or a fake fingernail may cause wrong readings of pulse oxygen saturation. ◆Please note the effects of degraded sensors that can degrade performance or cause other problems. Do not combine old andnew batteries, different brands batteries for using. Uncomfortable or painful feeling may appear if using the device ceaselessly,especially for the microcirculation barrier patient. It is recommended that the sensor should not be applied to the same finger for over 2 hours. The person who is allergic to silicon rubber can not use this device. Note:The device has no side-effects if administered correctly and residual risk is acceptable. Warnings Warning:Do not use the Oximeter in an environment with any inflammable gases, inflammable anesthetic, or other inflammable substances. Warning:Do not attempt to charge any common dry battery, as that could cause leakage, fire disaster, or even explosion. Dispose of exhausted batteries in accordance with environment protection regulations. Warning:Do not use the Oximeter in an MRI or CT environment. Warning:Do not operate the Oximeter when it is damp with overflow or water vapor condensation.Avoid movingthe Oximeter from an excessively-cold environment toa high-temperature moist environment. Warning:No modification of this equipment is allowed for safety. Warning:Do not use accessories and detachable parts not specified or authorized by manufacturer.Otherwise, it may cause damage to the unit or danger to the user or patients. Warning:Keep unit and lanyard away from children as the included lanyard may present an entanglement or choking hazard to small children. Adult supervision required; never leave children unattended with unit or lanyard. Warning:Do not throw the batteries into fire, as that could cause anexplosion. Warning:Close the battery cover…
Text truncated - open the document above for the full version.
ShenzhenJumperMedicalEquipmentCo.,Ltd. CoveredEquipmentCertificationAttestationLetter 2026/4/22 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA ATTN.:ReviewingEngineer FCCID:2ADYL-SPA11 ShenzhenJumperMedicalEquipmentCo.,Ltd.(“theapplicant”)certifiesthatthe equipmentforwhichauthorizationissoughtisnot“covered”equipmentprohibitedfrom receivinganequipmentauthorizationpursuanttosection2.903oftheFCCrules. Note:Iftheequipmentforwhichtheapplicantseeksauthorizationisproducedby anyoftheentitiesidentifiedonthecurrentCoveredList,theapplicantshould includeanexplanationonwhytheequipmentisnot“covered”equipment. ShenzhenJumperMedicalEquipmentCo.,Ltd.(“theapplicant”)certifiesthat,asofthe dateofthefilingoftheapplication,theapplicantisnotidentifiedontheCoveredList (asaspecificallynamedentityoranyofitssubsidiariesoraffiliates)asanentity producing“covered”equipment. ShenzhenJumperMedicalEquipmentCo.,Ltd.(“theapplicant”)certifiesthatthe equipmentforwhichauthorizationissoughtdoesnotincludecybersecurityoranti- virussoftwareproducedorprovidedbyKasperskyLab,Inc.oranyofitssuccessors andassignees,includingequipmentwithintegratedKasperskyLab,Inc.(oranyofits successorsandassignees)cybersecurityoranti-virussoftwarepursuanttoDA-24- 886andKDB986446D01CoveredEquipmentGuidancesectionB(2a). Signed: Printedname:Tiffany Zhang Title:Manager CompanyName:ShenzhenJumperMedical EquipmentCo.,Ltd. Date:2026/4/22
* the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. SC6047052 U.S. Agent Designation for Service of Process - Certification Attestation Letter 4/22/2026 TO: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 ATTN.: Reviewing Engineer FCC ID: 2ADYL-SPA11 FRN of applicant: 0024203473 Per section 2.911(d)(7) of the FCC rules, Shenzhen Jumper Medical Equipment Co.,Ltd FRN: 0024203473(“the applicant”) certifies that the equipment for which authorization is sought is designated to the following U.S. agent* for service of process: Company Name: Global Product Services and Consultation LLC FCC Registration Number (FRN): 0033406703 Physical U.S. Company Address: 328 W Palm Ave. Monrovia, CA91016 Contact Person: Michael Chan Tel: +1 626 366 4358 Agent Email Address: [email protected] The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Agent Signed (if different from Applicant): Signed: Printed name: Tiffany Zhang Title: RA Manager Company Name: Shenzhen Jumper Medical Equipment Co.,Ltd Date: 4/22/2026 Signed: Printed name: Michael Chan Title: Technical Director Company Name: Global Product Services and Consultation LLC Date: 4/22/2026
DATE:2026/4/22 FederalCommunicationsCommission Authorization&EvaluationDivision 7345OaklandMillsRoad Columbia,Maryland21046 AuthoritytoActasAgent Onourbehalf,IappointBlueAsiaofTechnicalServices(Shenzhen)Co.,LtdAnd BuildingC,No.107,ShihuanRoad,ShiyanSub-District,BaoanDistrict,Shenzhen, GuangdongProvince,China(NameofAgentcompanynameandaddress)toactasour agentinthepreparationofthisapplicationforequipmentcertification.Icertifythat submitteddocumentsproperlydescribethedeviceorsystemforwhichequipment certificationissought.Ialsocertifythateachunitmanufactured,importedormarketed,as definedintheFederalCommunicationsCommission’sregulationswillhaveaffixedtoita labelidenticaltothatsubmittedforapprovalwiththisapplication. Forinstanceswhereourauthorizedagentsignstheapplicationforcertificationonour behalf,Iacknowledgethatallresponsibilityforcomplyingwiththetermsandconditions forcertification,stillresideswithShenzhenJumperMedicalEquipmentCo.,Ltd.AndDBuilding, No.71,XintianRoad,FuyongStreet,Baoan,Shenzhen,Guangdong,China518103 (ApplicantName andaddress) <Signature> Name :TiffanyZhang Title:Manager Company:ShenzhenJumperMedicalEquipmentCo.,Ltd.
Date:2026/4/22 FederalCommunicationsCommission Authorization&EvaluationDivision 7345OaklandMillsRoad Columbia,Maryland21046 RE:LETTEROFAGENTAUTHORIZATION ToWhomItMayConcern: We,theundersigned,herebyauthorizeComplianceTesting,LLCtoactonourbehalfinallmatters relatingtoapplicationforequipmentauthorization,includingthesigningofalldocumentsrelatingto thesematters. Wealsoherebycertifythatnopartytotheapplicationauthorizedhereunderissubjecttothedenialof benefits,includingFCCbenefits,pursuanttoSection5301oftheAnti-DrugAbuseActof1988,21 U.S.C.853(a). Sincerely, <Signature> Name:TiffanyZhang Title:Manager Company:ShenzhenJumperMedicalEquipmentCo.,Ltd.
DATE2026/4/20 EquipmentAutorisationDivision FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 FCCID:2ADYL-SPA11 ProductName:PulseOximeter RequestforConfidentiality PursuanttoSections0.457and0.459ofthecommission’srules,weherebyrequestthat thefollowingdocumentsbeheldconfidential: (Listherethedocumentsforwhichyouareseekingconfidentiality–forexample...) Schematics Blockdiagram Operationdescription Thesematerialscontaintradesecretsandproprietaryinformationandarenot customarilyreleasedtothepublic.Thepublicdisclosureofthisinformationmightbe harmfultothecompanyandprovideunjustifiedbenefitstoourcompetitors. <Signature> Name:TiffanyZhang Title : Manager Company:ShenzhenJumperMedicalEquipmentCo.,Ltd.
ProductName:PulseOximeter
FCCID:2ADYL-SPA11
ProductName:PulseOximeter
Website:www.cblueasia.com Tel:+86-755-23059481 Email:[email protected] ThetestreportiseffectiveonlywithbothsignatureandspecializedstampandTheresult(s)showninthisreportreferonlytothesample(s)tested.Without writtenapprovalofBlueAsia,thisreportcan ’ tbereproducedexceptinfull.Theresultsdescribedinthisreportdonotrepresentthequalityorcharacteristicsofthe sampledbatch,nordotheyrepresentanysimilaroridenticalproductsthatarenotexplicitlystated. RFExposure Applicant:ShenzhenJumperMedicalEquipmentCo.,Ltd. Address: DBuilding,No.71,XintianRoad,FuyongStreet, Baoan,Shenzhen,Guangdong,China518103 ProductName:PulseOximeter BrandMark:N/A Model:SPA11 FCCID:2ADYL-SPA11 ReportNumber:BLA-EMC-202602-A6103 DateofReceipt:Feb.9,2026 DateofTest:Feb.9,2026toMar.20,2026 TestStandard: 47CFRPart15,Part1.1307 47CFRPart15,Part2.1093 KDB447498D04GeneralRFExposureGuidancev01 TestResult:Pass Compiledby:Reviewby:Approvedby: IssuedDate:Mar.20,2026 BlueAsiaTechnicalServices(Shenzhen)Co.,Ltd Address:No.41,SouthofBeihuanRoad,ShangwuCommunity,Shiyan Subdistrict,Bao'anDistrict,Shenzhen,Guangdong,China ReportNo.:BLA-EMC-202602-A6103 Page 2 of 7 BlueAsiaTechnicalServices(Shenzhen)Co.,Ltd Tel:+86-755-23059481 Email:[email protected] Version:v1.2 TableofContents 1Generalinformation................................................................................................................................................4 1.1Generalinformation..........................................................................................................................................4 1.2GeneraldescriptionofEUT..............................................................................................................................4 2Laboratoryandaccreditations..............................................................................................................................5 3RFExposureComplianceRequirement...............................................................................................................6 3.1StandardRequirement.....................................................................................................................................6 3.2Limits................................................................................................................................................................6 3.3Result...............................................................................................................................................................7 ReportNo.:BLA-EMC-202602-A6103 Page 3 of 7 BlueAsiaTechnicalServices(Shenzhen)Co.,Ltd Tel:+86-755-23059481 Email:[email protected] Version:v1.2 ReviseRecord VersionNo.DateDescription 01Mar.20,2026Original ReportNo.:BLA-EMC-202602-A6103 Page 4 of 7 BlueAsiaTechnicalServices(Shenzhen)Co.,Ltd Tel:+86-755-23059481 Email:[email protected] Version:v1.2 1Generalinformation 1.1Generalinformation ApplicantShenzhenJumperMedicalEquipmentCo.,Ltd. Address DBuilding,No.71,XintianRoad,FuyongStreet,Baoan,Shenzhen, Guangdong,China518103 ManufacturerShenzhenJumperMedicalEquipmentCo.,Ltd. Address DBuilding,No.71,XintianRoad,FuyongStreet,Baoan,Shenzhen, Guangdong,China518103 FactoryShenzhenJumperMedicalEquipmentCo.,Ltd. Address DBuilding,No.71,XintianRoad,FuyongStreet,Baoan,Shenzhen, Guangdong,China518103 1.2GeneraldescriptionofEUT ProductnamePulseOximeter Modelno.SPA11 SeriesmodelN/A OperationFrequency:2402MHz-2480MHz ModulationType:GFSK Ratedata:1Mbps ChannelSpacing:2MHz NumberofChannels:40 AntennaType:PCBantenna AntennaGain:0.18dBi(Providedbycustomer) Powersupplyoradapter information DC3Vbybattery HardwareVersionV0.0.1 SoftwareVersionV2.12 Note:Foramoredetaileddescription,pleaserefertoSpecificationorUser’sManualsuppliedby theapplicantand/ormanufacturer. ReportNo.:BLA-EMC-202602-A6103 Page 5 of 7 BlueAsiaTechnicalServices(Shenzhen)Co.,Ltd Tel:+86-755-23059481 Email:[email protected] Version:v1.2 2Laboratoryandaccreditations Thetestfacilityisrecognized,certified,oraccreditedbythefollowingorganizations: Companyname: BlueAsiaTechnicalServices(Shenzhen)Co.,Ltd. Address: No.41,SouthofBeihuanRoad,ShangwuCommunity,ShiyanSubdistrict,Bao’an District,Shenzhen,Guangdong,China CNASaccreditedNo.:L9788 A2LACert.No.:5071.01 FCCDesignationNo.:CN1252 ISEDCABidentifierNo.:CN0028 Telephone:+86-755-28682673 FAX:+86-755-28682673 ReportNo.:BLA-EMC-202602-A6103 Page 6 of 7 BlueAsiaTechnicalServices(Shenzhen)Co.,Ltd Tel:+86-755-23059481 Email:[email protected] Version:v1.2 3RFExposureComplianceRequirement 3.1StandardRequirement Accordingto447498D04InterimGeneralRFExposureGuidancev01 StandaloneSARtestexclusionconsiderations UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures,standalone1-gheador bodyand10-gextremitySARevaluationforgeneralpopulationexposureconditions,bymeasurement ornumericalsimulation,isnotrequiredwhenthecorrespondingSARExclusionThreshold condition,listedbelow,issatisfied. 3.2Limits ReportNo.:BLA-EMC-202602-A6103 Page 7 of 7 BlueAsiaTechnicalServices(Shenzhen)Co.,Ltd Tel:+86-755-23059481 Email:[email protected] Version:v1.2 3.3Result EIRP=ptxgt=(EXd) 2 /30 Where: pt=transmitteroutputpowerinwatts, gt=numericgainofthetransmittingantenna(unitless), E=electricfieldstrengthinV/m, d=measurementdistanceinmeters(m) Spot=(EXd) 2 /30xgt Separationdistance=0.5cm Antgain=0.18dBi ForBLE(Worst): MaxOutputpower=-0.146dBm@2402MHz EIRP=-0.146dBm+0.18dBi=0.034dBm=1.008mW<2.788mW ERP=0.034-2.15=-2.116dBm ComplywithRFexposureexemptionlimit. ----ENDOFREPORT---- Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,theresult(s)showninthisreportrefer onlytothesample(s)tested.WithoutwrittenapprovalofBlueAsia,thisreportcan’tbereproducedexceptinfull.
Website:www.cblueasia.com Tel:+86-755-23059481 Email:[email protected] ThetestreportiseffectiveonlywithbothsignatureandspecializedstampandTheresult(s)showninthisreportreferonlytothesample(s)tested.Without writtenapprovalofBlueAsia,thisreportcan ’ tbereproducedexceptinfull.Theresultsdescribedinthisreportdonotrepresentthequalityorcharacteristicsofthe sampledbatch,nordotheyrepresentanysimilaroridenticalproductsthatarenotexplicitlystated. TestReport Applicant:ShenzhenJumperMedicalEquipmentCo.,Ltd. Address: DBuilding,No.71,XintianRoad,FuyongStreet, Baoan,Shenzhen,Guangdong,China518103 ProductName:PulseOximeter BrandMark:N/A Model:SPA11 FCCID:2ADYL-SPA11 ReportNumber:BLA-EMC-202602-A6102 DateofReceipt:Feb.9,2026 DateofTest:Feb.9,2026toMar.20,2026 TestStandard:47CFRPart15,SubpartC15.247 TestResult:Pass Compiledby:Reviewby:Approvedby: IssuedDate:Mar.20,2026 BlueAsiaTechnicalServices(Shenzhen)Co.,Ltd. Address:No.41,SouthofBeihuanRoad,ShangwuCommunity,ShiyanSubdistrict,Bao’ anDistrict,Shenzhen,Guangdong,China ReportNo.:BLA-EMC-202602-A6102 Page 2 of 57 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 TableofContents 1Generalinformation................................................................................................................................................4 1.1Generalinformation..........................................................................................................................................4 1.2GeneraldescriptionofEUT..............................................................................................................................4 2Testsummary..........................................................................................................................................................5 3TestConfiguration..................................................................................................................................................6 3.1Testmode.........................................................................................................................................................6 3.2OperationFrequencyeachofchannel.............................................................................................................7 3.3Testchannel.....................................................................................................................................................7 3.4Auxiliaryequipment..........................................................................................................................................7 3.5Testenvironment..............................................................................................................................................7 4Laboratoryinformation..........................................................................................................................................8 4.1Laboratoryandaccreditations..........................................................................................................................8 4.2Measurementuncertainty.................................................................................................................................8 5Testequipment........................................................................................................................................................9 6Testresult..............................................................................................................................................................11 6.1Antennarequirement......................................................................................................................................11 6.2ConductedpeakoutputPower.......................................................................................................................12 6.3Minimum6dBbandwidth................................................................................................................................14 6.4Powerspectrumdensity.................................................................................................................................15 6.5ConductedBandEdgesMeasurement..........................................................................................................16 6.6Conductedspuriousemissions......................................................................................................................18 6.7Radiatedspuriousemissions.........................................................................................................................20 6.8Radiatedemissionswhichfallintherestrictedbands...................................................................................33 7AppendixA............................................................................................................................................................40 AppendixB:photographsoftestsetup......................................................................................................................56 AppendixC:photographsofEUT................................................................................................................................57 ReportNo.:BLA-EMC-202602-A6102 Page 3 of 57 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 ReviseRecord VersionNo.DateDescription 01Mar.20,2026Original ReportNo.:BLA-EMC-202602-A6102 Page 4 of 57 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 1Generalinformation 1.1Generalinformation ApplicantShenzhenJumperMedicalEquipmentCo.,Ltd. Address DBuilding,No.71,XintianRoad,FuyongStreet,Baoan,Shenzhen, Guangdong,China518103 ManufacturerShenzhenJumperMedicalEquipmentCo.,Ltd. Address DBuilding,No.71,XintianRoad,FuyongStreet,Baoan,Shenzhen,…
Text truncated - open the document above for the full version.
ReportNo.:BLA-EMC-202602-A6102 Page 31 of 57 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 [Testmode:TXHighchannel];[Polarity:Horizontal] TestResult:Pass ReportNo.:BLA-EMC-202602-A6102 Page 32 of 57 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 [Testmode:TXHighchannel];[Polarity:Vertical] TestResult:Pass ReportNo.:BLA-EMC-202602-A6102 Page 33 of 57 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 6.8Radiatedemissionswhichfallintherestrictedbands TestStandard47CFRPart15,SubpartC15.247(d) TestMethod ANSI C63.10-2020+Cor.1-2023+C63.10a-2024+ErratatoC63.10a-2024 Clause6.3,6.5,6.6,11.12.1 TestMode(Pre-Scan)TX TestMode(FinalTest)TX 6.8.1Limit Frequency(MHz) Field strength(microvolts/meter) Measurement distance(meters) 0.009-0.4902400/F(kHz)300 0.490-1.70524000/F(kHz)30 1.705-30.03030 30-881003 88-2161503 216-9602003 Above9605003 Remark:TheemissionlimitsshownintheabovetablearebasedonmeasurementsemployingaCISPR quasi-peakdetectorexceptforthefrequencybands9-90kHz,110-490kHzandabove1000MHz.Radiated emissionlimitsinthesethreebandsarebasedonmeasurementsemployinganaveragedetector,thepeakfield strengthofanyemissionshallnotexceedthemaximumpermittedaveragelimitsspecifiedabovebymorethan20 dBunderanyconditionofmodulation. ReportNo.:BLA-EMC-202602-A6102 Page 34 of 57 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 6.8.2Testsetup Below1GHz: 30MHz-1GHz: Above1GHz: ReportNo.:BLA-EMC-202602-A6102 Page 35 of 57 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 6.8.3Procedure a)Forbelow1GHz,theEUTwasplacedonthetopofarotatingtable0.8metersabovethegroundat a3or10metersemi-anechoicchamber.Thetablewasrotated360degreestodeterminethe positionofthehighestradiation. b)Forabove1GHz,theEUTwasplacedonthetopofarotatingtable1.5metersabovethegroundat a3meterfully-anechoicchamber.Thetablewasrotated360degreestodeterminethepositionof thehighestradiation. c)TheEUTwasset3or10metersawayfromtheinterference-receivingantenna,whichwasmounted onthetopofavariable-heightantennatower. d)Theantennaheightisvariedfromonemetertofourmetersabovethegroundtodeterminethe maximumvalueofthefieldstrength.Bothhorizontalandverticalpolarizationsoftheantennaare settomakethemeasurement. e)Foreachsuspectedemission,theEUTwasarrangedtoitsworstcaseandthentheantennawas tunedtoheightsfrom1meterto4meters(forthetestfrequencyofbelow30MHz,theantennawas tunedtoheights1meter)andtherotatabletablewasturnedfrom0degreesto360degreestofind themaximumreading. f)Thetest-receiversystemwassettoPeakDetectFunctionandSpecifiedBandwidthwithMaximum HoldMode. g)IftheemissionleveloftheEUTinpeakmodewas10dBlowerthanthelimitspecified,thentesting couldbestoppedandthepeakvaluesoftheEUTwouldbereported.Otherwisetheemissionsthat didnothave10dBmarginwouldbere-testedonebyoneusingpeak,quasi-peakoraverage methodasspecifiedandthenreportedinadatasheet. h)TesttheEUTinthelowestchannel,themiddlechannel,thehighestchannel. i)TheradiationmeasurementsareperformedinX,Y,ZaxispositioningforTransmittingmode,and foundtheXaxispositioningwhichitistheworstcase. j)Repeataboveproceduresuntilallfrequenciesmeasuredwascomplete. Note1:Level(dBuV)=Reading(dBuV)+Factor(dB/m) Note2:Forfrequenciesabove1GHz,thefieldstrengthlimitsarebasedonaveragelimits.However,thepeakfield strengthofanyemissionshallnotexceedthemaximumpermittedaveragelimitsspecifiedabovebymorethan20 dBunderanyconditionofmodulation.Fortheemissionswhosepeaklevelislowerthantheaveragelimit,only thepeakmeasurementisshowninthereport. ReportNo.:BLA-EMC-202602-A6102 Page 36 of 57 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 6.8.4Testdata [Testmode:TXlowchannel];[Polarity:Horizontal] TestResult:Pass ReportNo.:BLA-EMC-202602-A6102 Page 37 of 57 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 [Testmode:TXlowchannel];[Polarity:Vertical] TestResult:Pass ReportNo.:BLA-EMC-202602-A6102 Page 38 of 57 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 [Testmode:TXHighchannel];[Polarity:Horizontal] TestResult:Pass ReportNo.:BLA-EMC-202602-A6102 Page 39 of 57 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 [Testmode:TXHighchannel];[Polarity:Vertical] TestResult:Pass ReportNo.:BLA-EMC-202602-A6102 Page 40 of 57 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 7AppendixA 7.1.1MaximumConductedOutputPower ConditionModeFrequency(MHz)AntennaConductedPower(dBm)Limit(dBm)Verdict NVNTBLE2402Ant1-0.14630Pass NVNTBLE2442Ant1-0.83730Pass NVNTBLE2480Ant1-1.54930Pass ReportNo.:BLA-EMC-202602-A6102 Page 41 of 57 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 PowerNVNTBLE2402MHzAnt1 PowerNVNTBLE2442MHzAnt1 ReportNo.:BLA-EMC-202602-A6102 Page 42 of 57 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 PowerNVNTBLE2480MHzAnt1 ReportNo.:BLA-EMC-202602-A6102 Page 43 of 57 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Version:v1.3 7.1.2-6dBBandwidth ConditionModeFrequency (MHz) Antenna-6dBBandwidth (MHz) Limit-6dBBandwidth (MHz) Verdict NVNTBLE2402Ant10.7580.5Pass NVNTBLE2442Ant10.7170.5Pass NVNTBLE2480Ant10.7560.5Pass -6dBBandwidthNVNTBLE2402MHzAnt1 ReportNo.:BLA-EMC-202602-A6102 Page 44 of 57 BlueAsia…
Text truncated - open the document above for the full version.
深圳市飞敏科技有限公司 ShenZhen City FeiMin Technology CO.,LTD. Tel: 86-0755-23035723 Fax: 86-0755-23036702 E-mail: [email protected] www.fmant.cn - 1 - 飞敏科技OTA 天线数据报告 1.样机型号: 板载蓝牙 日期:2018.10.31 1.1测试项目: 驻波比 增益 效率 方向图 2.Test Result 2.1 Test conditions Test Environment Conditions: Relative Humindity: 15....75% Temperature: +10°C to +30°C Voltage of the EUT: N/A 2.2 Test Results lists 天 线 无 源 数 据 深圳市飞敏科技有限公司 ShenZhen City FeiMin Technology CO.,LTD. Tel: 86-0755-2303…
Text truncated - open the document above for the full version.
328 W Palm Ave., Monrovia, CA 91016, United States · Monrovia, California, 91016
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 967.00 µW |

Electronic Blood Pressure Monitor
Equipment Class
DTS - Digital Transmission System
Pulse Oximeter
Equipment Class
CXX - Communications Rcvr for use w/ licensed Tx and CBs
Body Fat Scale
Equipment Class
DTS - Digital Transmission System
Weight scale
Equipment Class
DTS - Digital Transmission System
Electronic Blood Pressure Monitor
Equipment Class
DTS - Digital Transmission System