FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ShenZhen Jumper Medical Equipment Co.,Ltd/
  3. 2ADYL-500G501G

2ADYL-500G501GPulse Oximeter

ShenZhen Jumper Medical Equipment Co.,Ltd
Pulse Oximeter - FCC ID 2ADYL-500G501G - ShenZhen Jumper Medical Equipment Co.,Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 17, 2021
Application Purpose
Original Equipment
Date of Application
Mar 17, 2021
Equipment Note
Pulse Oximeter
Frequency Range
2402.00000000 - 2480.00000000
Company
ShenZhen Jumper Medical Equipment Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

PulseOximeterJPD-500G(Bluetooth) DateofIssue:2020.11,Version:V1.1 FCCstatement ThisdevicecomplieswithPart15oftheFCCRules.Operationissubject tothefollowingtwoconditions: (1)Thisdevicemaynotcauseharmfulinterference. (2)Thisdevicemustacceptanyinterferencereceived,includinginterferencethat maycauseundesiredoperation. NOTE:Thisequipmenthasbeentestedandfoundtocomplywiththelimits foraClassBdigitaldevice,pursuanttoPart15oftheFCCRules.Theselimits aredesignedtoprovidereasonableprotectionagainstharmfulinterferencein aresidentialinstallation.Thisequipmentgenerates,usesandcanradiate radiofrequencyenergyand,ifnotinstalledandusedinaccordance withtheinstructions,maycauseharmfulinterferencetoradiocommunications. However,thereisnoguaranteethatinterferencewillnotoccurinaparticular installation.Ifthisequipmentdoescauseharmfulinterferencetoradioor televisionreception,whichcanbedeterminedbyturningtheequipmentoff andon,theserisencouragedtotrytocorrecttheinterferencebyoneormore ofthefollowingmeasures: ●Reorientorrelocatethereceivingantenna. ●Increasetheseparationbetweentheequipmentandreceiver. ●Connecttheequipmentintoanoutletonacircuitdifferentfromthatto whichthereceiverisconnected. ●Consultthedealeroranexperiencedradio/TVtechnicianforhelp. Warning:Changesormodificationstothisunitnotexpresslyapprovedbythe partyresponsibleforcompliancecouldvoidtheuser’sauthoritytooperate theequipment. Precautions  DonotattempttorepairheOximeterunlessyouareprofessionalengineers.Only professionalswithmaintenancequalificationareallowedtoperforminterior maintenanceasnecessary.  ChangethecontactpositionbetweentheOximeterprobeandthefinger periodicallyifyouaremonitoringyourSpO2levelsandpulserateformorethan2 hours.  Stopimmediatelyifyouhavebrokenskinorthebloodcirculationofyourfingeris affectedduringprolonguse.  Thisproductisnotdesignedtobeusedbynewbornbabies. Seekformedicalcareifthemeasuredvaluegoesbeyondthenormalrangeandyou aresurethattheinstrumentisnotmalfunctioning.  Thepulseoximeterusesinfraredlight(invisibletoyoureyes)tomeasureyour SpO2levels.Hence,pleasedonotstareatthelight-emittingcomponentsofthe Oximeter,asthatcouldcauseharmand/orpotentiallyblindyoureyes.  Thispulseoximeterisnotintendedtodiagnoseortreatanymedicalconditionor disease.PeoplewhoneedSpO2andpulseratemeasurementsbecauseofamedical conditionshouldnotusetheoximeterandshouldconsultwiththeirphysician.  Fordetailsaboutclinicallimitationsandcontraindications,pleasecarefullyconsult relevantmedicalliteratures. Thefollowingfactorsmayaffecttheaccuracyofthemeasurement:  TheOximeterisusedinanenvironmentinvolvinghigh-frequencydevices, suchashigh-frequencyelectricknivesandCTapparatuses.  Ambientlightintensityistoobright.Hence,pleaseavoiddirectexposureto stronglight(suchasbeamsfromoperatinglampsorsunlight)during measurement.  TheprobeoftheOximeterisplacedonthesamearmthatabloodpressure cuffarterialductorintravenousinjection.  Theusersuffersfromhypotension,severevascularatrophy,severeanemia, orlowoxygen.  Theuserisinsuddencardiacarrestorshockstate. Theuseriswearingnailpolishorartificialnails. Warnings Warning:DonotusetheOximeterinanenvironmentwithanyflammablegases, flammableanesthetic,orotherflammablesubstances. Warning:Keepunitandlanyardawayfromchildrenastheincludedlanyardmay presentanentanglementorchokinghazardtosmallchildren.Adultsupervision required;neverleavechildrenunattendedwithunitorlanyard Warning:Donotthrowthebatteriesintofire,asthatcouldcauseanexplosion. Warning:Donotattempttochargetheincludedbatteries,asthatcouldcause leakage,firedisaster,orevenexplosion.Disposetheusedbatteriesinaccordanceto thelocallawsandregulations. Warning:DonotusetheOximeterinanMRIorCTenvironment. Warning:DonotoperatetheOximeterifitiswet.Avoidmovingtheoximeterfrom acoldtoahotandhumidenvironment. Warning:InstallthebatteriesproperlybeforepoweringontheOximeterfornormal use.PleaseremovethebatteriesifyouarenotplanningtousetheOximeterfora longtime. Warning:Closethebatterycoverwhentheinstrumentisinuse. Symbols Symbol Meaning TypeBFappliedpart Caution:Pleaseseethismanual. %SpO2Symbolofoxygensaturation bpmPRSymbolofpulserate NoSpO2alarms. Bluetooth Whenendusersabandonthisproduct,theymustsend theproducttothecollectionplaceforrecycling. Consulttheinstructionsforuse. Overview Oxygensaturationisthepercentageofoxyhemoglobin(HbO2)thatiscombined withoxygenagainstallcombinablehemoglobin(Hb).Itisanimportantphysiological parameterinvolvedinrespirationandcirculation.Theoxygensaturationofarterial bloodinanormalhumanbodyis98%.Oxygensaturationisanimportantindicator oftheoxygenconditioninthehumanbody.Ingeneral,thenormalvaluesofoxygen saturationshallnotbelowerthan94%.Ifthemeasuredvalueofoxygensaturation islowerthan94%,aninsufficientsupplyofoxygenisconsidered. Thepulserateisthenumberofpulsebeatsperminute.Normally,thepulserateis consistentwiththeheartrate.Ingeneral,thepulserateofeverypeopleis60to90 beatsperminute. ThePerfusionIndex(PI)usuallyreflectsthelimbperfusionstatusofanexamined patient,andshowsthedetectionprecisionoftheinstrumentaswell;thatis, examinationcanstillbeperformedevenintheloworweakperfusioncondition.The PIofanormalhumanbodyis3%orgreater. WorkingPrinciplesandUsage Basedonfulldigitaltechnology,theFingerPulseOximeternon-invasivelymeasures theactualcontent(oxygensaturation)ofoxyhemoglobin(HbO2)inarterialblood usingtheopticaltransmittancemethod. TheFingerPulseOximetermeasuresthebloodoxygensaturationandpulserateof ahumanbodyviafingerartery.Itisapplicabletoawiderangeoffields,suchas families,hospitals(includingoperationroomsofthedepartmentsofinternal medicineandsurgery,thedepartmentofanesthesiology,thedepartmentof paediatrics,andintensivecarerooms),oxygenbars,socialmedicalcareinstitutions, andsports&health.Usethisinstrumentformeasurementbeforeoraftersports. Youarenotadvisedtousethisinstrumentduringsportsactivities.Donotuseitfor continuouscareforpatients. SchematicDiagramofDisplay SchematicDiagramofDisplay ThefollowingfigureshowstheinformationdisplayontheLEDscreenofthe Oximeterinnormaldetectionstate: Power-Onb…

Text truncated - open the document above for the full version.

External Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 4 External Photos for SZEM2101001125CR FCC ID: 2ADYL-500G501G SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 4 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 4 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 4

ID Label/Location Info

19.5mm 500G LABEL Year 2018,2019, 2020 ...... JPD-500G A0 Rev.Date: P/N: 500G_JUMPER_LABEL_001 (01)06951740538374(10)18090101000(21)8329500G83321 01069517405383741018090101000218329500G83321 (01)06951740538374 (10)18090101000 (21)8329500G83321 2019-04 Pulse Oximeter Model: JPD-500G MedPath GmbH Mies-van-der-Rohe-Strasse 8, 80807 Munich, Germany D Building,No.71,Xintian Road,Fuyong Street, Baoan,ShenzhenGuangdong,China V1.1 FCC ID:2ADYL-500G501G Label Location

Internal Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 4 Internal Photos for SZEM2101001125CR FCC ID: 2ADYL-500G501G SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 4 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 4 Antenna SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 4

RF Exposure Info

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM210100112503 Page: 1 of 6 Keny Xu EMC Laboratory Manager 1 Cover page SAR Evaluation Report Application No.: SZEM2101001125CR Applicant: Shenzhen Jumper Medical Equipment Co., Ltd. Address of Applicant: D Building, No. 71, Xintian Road, Fuyong Street, Baoan, Shenzhen, Guangdong, China Manufacturer: Shenzhen Jumper Medical Equipment Co., Ltd. Address of Manufacturer: D Building, No. 71, Xintian Road, Fuyong Street, Baoan, Shenzhen, Guangdong, China Factory: Shenzhen Jumper Medical Equipment Co., Ltd. Address of Factory: D Building, No. 71, Xintian Road, Fuyong Street, Baoan, Shenzhen, Guangdong, China Equipment Under Test (EUT): EUT Name: Pulse Oximeter Model No.: JPD-500G, JPD-501G   Please refer to section 4 of this report which indicates which model was actually tested and which were electrically identical. FCC ID: 2ADYL-500G501G Standards: 47 CFR Part 1.1307 47 CFR Part 2.1093 KDB447498D01 General RF Exposure Guidance v06 Date of Receipt: 2021-01-26 Date of Test: 2021-01-27 to 2021-02-04 Date of Issue: 2021-02-04 Test Result : Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM210100112503 Page: 2 of 6 2 Version Revision Record Version Chapter Date Modifier Remark 01 2021-02-04 Original Authorized for issue by: Edison Li /Project Engineer Eric Fu /Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM210100112503 Page: 3 of 6 3 Contents Page 1 COVER PAGE .............................................................................................................................................. 1 2 VERSION ...................................................................................................................................................... 2 3 CONTENTS .................................................................................................................................................. 3 4 GENERAL INFORMATION .......................................................................................................................... 4 4.1 GENERAL DESCRIPTION OF EUT ............................................................................................................. 4 4.2 TEST LOCATION ...................................................................................................................................... 5 4.3 TEST FACILITY ........................................................................................................................................ 5 4.4 DEVIATION FROM STANDARDS ................................................................................................................. 5 4.5 ABNORMALITIES FROM STANDARD CONDITIONS ....................................................................................... 5 4.6 OTHER INFORMATION REQUESTED BY THE CUSTOMER ............................................................................. 5 5 SAR EVALUATION ...................................................................................................................................... 6 5.1 RF EXPOSURE COMPLIANCE REQUIREMENT ............................................................................................ 6 5.1.1 Standard Requirement ..................................................................................................................... 6 5.1.2 Limits ................................................................................................................................................ 6 5.1.3 EUT RF Exposure ............................................................................................................................ 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM210100112503 Page: 4 of 6 4 General Information 4.1 General Description of EUT Power supply: DC 3V(DC 1.5V AAA battery*2) Internal Source: More than 108MHz Frequency Range: 2402MHz to 2480MHz Bluetooth Version: V4.1 Modulation Type: GFSK Number of Channels: 40 Sample Type: Portable device Antenna Type: Integral Antenna Gain: 1dBi Remark: Model No.: JPD-500G, JPD-501G Only the model JPD-500G was tested, since according to the declaration from the applicant, the electrical circuit design, layout, components used, internal wiring and functions were identical for the above models, with only difference on model No.. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM210100112503 Page: 5 of 6 4.2 Test Location All tests were performed at: SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong, China 518057 Telephone: +86 (0) 755 2601 2053 Fax: +86 (0) 755 2671 0594 No tests were sub-contracted. 4.3 Test Facility The test facility is recognized, certified, or accredited by the following organizations: • A2LA (Certificate No. 3816.01) SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01. • VCCI The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz, Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have been registered in accordance with the Regulations for Voluntary Control Measures with Registration No.: G-20026, R-14188, C-12383 and T-11153 respectively. • FCC –Designation Number: CN1178 SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized as an accredited testing laboratory. Designation Number: CN1178. Test Firm Registration Number: 406779. • Innovation, Science and Economic Development Canada SGS-CSTC Standards Tech…

Text truncated - open the document above for the full version.

Test Report

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM210100112502 Page: 1 of 48 Keny Xu EMC Laboratory Manager TEST REPORT Application No.: SZEM2101001125CR Applicant: Shenzhen Jumper Medical Equipment Co., Ltd. Address of Applicant: D Building, No. 71, Xintian Road, Fuyong Street, Baoan, Shenzhen, Guangdong, China Manufacturer: Shenzhen Jumper Medical Equipment Co., Ltd. Address of Manufacturer: D Building, No. 71, Xintian Road, Fuyong Street, Baoan, Shenzhen, Guangdong, China Factory: Shenzhen Jumper Medical Equipment Co., Ltd. Address of Factory: D Building, No. 71, Xintian Road, Fuyong Street, Baoan, Shenzhen, Guangdong, China Equipment Under Test (EUT): EUT Name: Pulse Oximeter Model No.: JPD-500G, JPD-501G   Please refer to section 2 of this report which indicates which model was actually tested and which were electrically identical. FCC ID: 2ADYL-500G501G Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2021-01-26 Date of Test: 2021-01-27 to 2021-02-04 Date of Issue: 2021-02-04 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM210100112502 Page: 2 of 48 Revision Record Version Chapter Date Modifier Remark 01 2021-02-04 Original Authorized for issue by: Edison Li/Project Engineer Eric Fu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM210100112502 Page: 3 of 48 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Peak Output Power 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.9.1 47 CFR Part 15, Subpart C 15.247(b)(3) Pass Minimum 6dB Bandwidth 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.8.1 47 CFR Part 15, Subpart C 15.247a(2) Pass Power Spectrum Density 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.10.2 47 CFR Part 15, Subpart C 15.247(e) Pass Conducted Band Edges Measurement 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.13.3.2 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.11 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.4,6.5,6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Remark: Model No.: JPD-500G, JPD-501G Only the model JPD-500G was tested, since according to the declaration from the applicant, the electrical circuit design, layout, components used, internal wiring and functions were identical for all the above models, with only difference on model No.. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM210100112502 Page: 4 of 48 3 Contents Page 1 COVER PAGE ............................................................................................................................................ 1 2 TEST SUMMARY ....................................................................................................................................... 3 3 CONTENTS ................................................................................................................................................ 4 4 GENERAL INFORMATION ........................................................................................................................ 6 4.1 DETAILS OF E.U.T. ............................................................................................................................... 6 4.2 DESCRIPTION OF SUPPORT UNITS ......................................................................................................... 6 4.3 MEASUREMENT UNCERTAINTY .............................................................................................................. 6 4.4 TEST LOCATION .................................................................................................................................... 7 4.5 TEST FACILITY ...................................................................................................................................... 7 4.6 DEVIATION FROM STANDARDS ............................................................................................................... 7 4.7 ABNORMALITIES FROM STANDARD CONDITIONS ..................................................................................... 7 5 EQUIPMENT LIST ...................................................................................................................................... 8 6 RADIO SPECTRUM TECHNICAL REQUIREMENT ............................................................................... 10 6.1 ANTENNA REQUIREMENT .................................................................................................................... 10 6.1.1 Test Requirement: ....................................................................................................................... 10 7 RADIO SPECTRUM MATTER TEST RESULTS ..................................................................................... 11 7.1 CONDUCTED PEAK OUTPUT POWER .................................................................................................... 11 7.1.1 E.U.T. Operation .......................................................................................................................... 11 7.1.2 Test Mode Description ................................................................................................................. 11 7.1.3 Test Setup Diagram ......................................…

Text truncated - open the document above for the full version.

Test Setup Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 3 Setup Photos for SZEM2101001125CR FCC ID: 2ADYL-500G501G SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 3 1 Photographs 1.1 Radiated Emissions which fall in the restricted bands Test Setup 1.2 Radiated Spurious Emissions Test Setup SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 3

Contact Information

Applicant

Tiffany Zhang(RA manager)
[email protected]86-755-26696279Fax: 86-755-26852025

Technical Contact

SGS-CSTC Standards Technical Services Co., Ltd.Keny Xu
[email protected]86-755-25328629

No.1 Workshop, M-10, Middle Section, · Shenzhen · China

Test Firm

SGS-CSTC Standards Technical Services Co., LtdDerek Yang
[email protected]+86 0135 6484 8721

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz450.00 µW
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted.

Other Applications from ShenZhen Jumper Medical Equipment Co.,Ltd

Pulse Oximeter - FCC ID 2ADYL-SPA11 - ShenZhen Jumper Medical Equipment Co.,Ltd
2ADYL-SPA11

Pulse Oximeter

May 20, 2026

Equipment Class

DTS - Digital Transmission System
Electronic Blood Pressure Monitor - FCC ID 2ADYL-JPDHA200C - ShenZhen Jumper Medical Equipment Co.,Ltd
2ADYL-JPDHA200C

Electronic Blood Pressure Monitor

May 15, 2026

Equipment Class

DTS - Digital Transmission System
Pulse Oximeter - FCC ID 2ADYL-JPD500D - ShenZhen Jumper Medical Equipment Co.,Ltd
2ADYL-JPD500D

Pulse Oximeter

Jul 30, 2024

Equipment Class

CXX - Communications Rcvr for use w/ licensed Tx and CBs
Body Fat Scale - FCC ID 2ADYL-JPD-BFS300 - ShenZhen Jumper Medical Equipment Co.,Ltd
2ADYL-JPD-BFS300

Body Fat Scale

Jul 05, 2024

Equipment Class

DTS - Digital Transmission System
Weight scale - FCC ID 2ADYL-JPD-BS300 - ShenZhen Jumper Medical Equipment Co.,Ltd
2ADYL-JPD-BS300

Weight scale

Jul 04, 2024

Equipment Class

DTS - Digital Transmission System