s Version:V1.0 RevisionDate:2023.10 BluetoothElectronicBloodPressureMonitor HAA21UserManual 1 Product Composition The product is comprised of the host machine and the cuff of Electronic Blood Pressure Monitor. Intended use The Electronic Blood Pressure Monitor is intended to measure the systolic and diastolic blood pressure as well as the pulse rate of adult person via non-invasive oscillometric technique at medical facilities or at home. FCC ID:2ADYL-HAA21 2 ThewarningsandillustrationsshownintheUserManualenableyouto usetheproductsafelyandcorrectly,thuspreventingyouandothers frombeinginjured,specificallyasfollows: Legend,markandmeaning Warningmessage Anti-electricshockdegreeisTypeBFofthe applicationpart Whentheproductlifeexpiresandtheendusers discardtheproducts,sendthemtothedesignated collectingandseparatingplacefordisposal accordingtotherequirementsfromthelocal environmentalprotectionauthority. Consulttheinstructionsforuse. ThisproductcomplieswiththeMDD93/42/EEC requirements. IP21 Degreeofprotectionagainsttheingressofwater. Informationofmanufacturer Dateofmanufacture AuthorizedEuropeanRepresentative SafetyPrecautions 3 Avoidsmoking,eating,drinkingcaffeinateddrinksorexercisingfor30 minutesbeforetakingmeasurement. 1.Situprightinachairwithbothfeetonthefloor. 2.Removetightfittingclothingfromyourupper armalongwithanythickclothing. 3.Pullontheendofthecuffuntilitwraps securelyaroundyourupperarm.Placeyourarmon atablesothatthecuffwillbeatthesamelevelas yourheart. 4.Thecuffwillautomaticallyinflateandthemeasurementwillstart, uponpressingthe“”button. 5.Whenthemeasurementiscomplete,thecuffwillautomatically deflateandyoursystolicanddiastolicpressurevaluesandpulseratewill bedisplayed. QuickStartGuide 4 Structure ①AirJack ②UserButton ③ PowerButton ⑤VolumeSwitch ⑥USBExternalPowerSupply Interface ④MemoryButton Features Dualusersandguestmode 199Readings*2Users VoiceReminderFunction AverageofLast3Readings IrregularHeartbeatDetector Auto-offPowerSavingFeature Operatedby4AABatteries(USB5Voptional) UniversalCuff Overview 5 Display PackingList No.NameQuantity 1ElectronicBloodPressureMonitor1 2Cuff1 3DryBattery(AAA)4 4UserManual1 5ZippedCarryingBag1 6 2.1BatteryInstallation a)Openthebatterycoverasshowninthe picture. b ) Place4AAAdrybatteries.Pay attentiontothebatteryelectrode indication. 2.2Batterypowerindicationandreplacement Aftertheproductisturnedon,iflowpowersymbolappearsonthe screen,themeasurementcannotbeperformed,andthebatterymustbe replaced. Donotuseanyexpiredbattery; Iftheproductisnotusedforover3months,pleasetakeout thebatteries. 2.3USBPowerSupply USBlinecanbeconnectedforpowersupplyoftheproductwithout battery. Preparation 7 2.4Cuff Theapplicablearmcircumferencerangeofthecuffis22-36cmor 22-42cm. Connection:Inserttheairplugofcuffairtubeintoairjackofthe ElectronicBloodPressureMonitor.Figureasshownabove. 8 3.1Usermode Switchbetween“User1” 、 “User2”and“Guest”canbeprocessedin theshutdownstateoruponthemeasurementcompletion,byshortpress onthe“User”button. (Note:Intheshutdownstate,press“User”buttontoviewthe currenttimeandthecurrentuser) 3.2Year/Month/Date/Timesetting Inthe“OFF”state,enterthesettingmodebylongpressonthe “User”buttonover3s,thenenterthe“Year”settingmode. Afterenteringthe“Year”settingmode,20XXwillflashonthescreen. Pressthe“Memory”button,andthevaluewillbeincremented among2019and2039.Pressthe“User”buttonfor“Year”value confirmationandmovetothe“Month”settingmode. Afterenteringthe“Month”settingmode,1-1willflashonthescreen. Pressthe“Memory”buttonandthevaluewillbeincremented among1and12.Pressthe“User”buttonfor“Month”value confirmationandenterthe“Date”settingmode. FunctionSettingMode 9 Afterenteringthe“Date”settingmode,1-1willflashonthescreen. Pressthe“Memory”buttonandthevaluewillbeincremented among1and31.Pressthe“User”buttonfor“Date”value confirmationandenterthe“Time”settingmode. Afterenteringthe“Time”settingmode,XX:XXwillflashonthescreen. Pressthe“Memory”button,andthe“Hour”valuecanbesetting. Pressthe“User”buttonfor“Hour”valueconfirmationandenter the“Minute”settingmode.Pressthe“Memory”button,andthe “Minute”valuecanbesetting. Note: Whensettingtimevalues,continuepressingthe“Memory”button tillthecorrectvaluesarewellset.Whentheceilingvalueofacertain timesectorisreached,therelevantvalueofthesectorwillstartfromthe minimumindividually. 10 3.3Unitsetting EithermmHgorKPawillshowuponthescreen,uponenteringthe “Unit”settingmodebypressingthe“User”button(afterthe “Minute”settingmode).DisplayofmmHgindicatesthatthemmHgunit isselected;displayofKPaindicatesthatthekPaunitisselected.Unit willbeswitcheduponeverypressonthe“Memory”button.After theunitisselected,pressthe“User”buttonagaintosavetheunit setting. 3.4Talkingfunction Thetalkingfunctioncanbeturnedon/offbypressingthevoiceswitch buttonontheleftsideofthedevice.Thevoiceiconwillbedisplayed onthescreenwhenthevoiceison,andwilldisappearwhenthevoiceis off.Theswitchbuttonisshownasbelow: 11 4.1Howtousethecuff (1)Placethecuffflatonthetable,leavethehook&loopdownwards, andpasstheendofcuffthroughthemetalringtoformaloop.Thehook &loopshallpointoutwards. (2)Pullthecuffthroughtheupperarmtobemeasured,andwearthe cuffcorrectlybasedonthedownwardicon“Φ”,theairtuberunsdown theinsideofyourarm.Hookupthecuffontheupperarmaccordingto theillustration,ensurethattheloweredgeofcuffis2~3cmawayfrom theelbowjoint.Tightenthefreeedgeofcufftostickthehook&loop. CorrectMethodofUse 12 (3)Thecuffshouldbewrappedontheupperarmcomfortably,with tightspacefortwofingers.Beforemeasurement,removetightfitting clothingfromyourupperarmalongwithanythickclothing. (4)Placethelowerarmflatonthedesktop,leavingthecenterofpalm naturallyupwards,sittingupright,andensuringthecenterofcuffand theheartareatthesamelevel.Notethatthetubeofcuffcannotbe foldedorbent. Note:Ifyoucannotusetheleftarmformeasurement,pleaseusethe rightarmformeasurement.Allthemeasurementsmustbeperformedon thesamearmforcomparison. 4.2Startingmeasurement Poweronstate,afteryouwearthecuffcorrectly,the“cuffdetection icon”lightsup,thenyoucanstartthemeasurement: 13 …
Text truncated - open the document above for the full version.
Attestation Statements March 11, 2024 TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA RE: Attestation Statements Part 2.911(d)(7) request for (FCC ID:2ADYL-HAA21) ShenZhen Jumper Medical Equipment Co.,Ltd, the undersigned, hereby authorize Lucky Cowboy Global Services, LLC to act as our designated U.S. agent for service of process, ShenZhen Jumper Medical Equipment Co.,Ltd accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Lucky Cowboy Global Services, LLC accepts the responsibility to act as designated U.S. agent for service of process. Applicant Information: Company Name:ShenZhen Jumper Medical Equipment Co.,Ltd Contact Name:Tiffany Zhang Address:D Building, No. 71, Xintian Road, Fuyong Street, Baoan,Shenzhen, Guangdong,China FRN: 0024203473 Telephone No:86-755-26696279 Email:[email protected] Signature [Tiffany Zhang] U.S. Agent Information: Company Name: Lucky Cowboy Global Services, LLC Address: 2213 S. Braeswood Blvd. #12E Houston, TX 77030 USA FRN: 0033510934 Contact Name: Louie Liu Telephone No: +1 (713) 992-3369 Email: [email protected] Signature [Louie Liu]
Page 1 of 5 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Add:BuildingC,No.107,ShihuanRoad,ShiyanSub-District,BaoanDistrict,Shenzhen,GuangdongProvince,China Tel:+86-755-23059481Email:[email protected] ProductName: ElectronicBloodPressureMonitor APPENDIXB:PHOTOGRAPHSOFEUT ReportNo.:BLA-EMC-202401-A5101 Page 2 of 5 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] ReportNo.:BLA-EMC-202401-A5101 Page 3 of 5 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] ReportNo.:BLA-EMC-202401-A5101 Page 4 of 5 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] ReportNo.:BLA-EMC-202401-A5101 Page 5 of 5 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected]
Label: Location:
Page1of3 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Add:BuildingC,No.107,ShihuanRoad,ShiyanSub-District,BaoanDistrict,Shenzhen,GuangdongProvince,China Tel:+86-755-23059481Email:[email protected] ProductName: ElectronicBloodPressureMonitor APPENDIXB:PHOTOGRAPHSOFEUT ReportNo.:BLA-EMC-202401-A5101 Page2of3 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] ReportNo.:BLA-EMC-202401-A5101 Page3of3 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected]
RFExposureevaluation ProductName: ElectronicBloodPressureMonitor FCCID: 2ADYL-HAA21 TestStandard: KDB447498D04GeneralRFExposureGuidance v01 Accordingto447498D04InterimGeneralRFExposureGuidancev01 Antgain=0dBi MAXoutputpower:-2.92dBm@2402MHz ERP=-2.92+0-2.15=-5.07dBm WORSECASE: 10^-0.292=0.511mW<2.715mW ThenSARevaluationisnotrequired
Page 1 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Add:BuildingC,No.107,ShihuanRoad,ShiyanSub-District,BaoanDistrict,Shenzhen,GuangdongProvince,China Tel:+86-755-23059481Email:[email protected] TESTREPORT ProductName: ElectronicBloodPressureMonitor BrandMark: Jumper ModelNo.: HAA21 ReportNumber: BLA-EMC-202401-A5102 FCCID: 2ADYL-HAA21 DateofSampleReceipt: 2024/1/19 DateofTest: 2024/1/19to2024/3/25 DateofIssue: 2024/3/25 TestStandard: 47CFRPart15,SubpartC15.247 TestResult:Pass Preparedfor: ShenzhenJumperMedicalEquipmentCo.,Ltd. DBuilding,No.71,XintianRoad,FuyongStreet,Baoan,Shenzhen, Guangdong,China518103 Preparedby: BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. BuildingC,No.107,ShihuanRoad,ShiyanSub-District,BaoanDistrict, Shenzhen,GuangdongProvince,China TEL:+86-755-23059481 Compiledby:Reviewby: Approvedby:Date:2024/3/25 ReportNo.:BLA-EMC-202401-A5102 Page 2 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] REPORTREVISERECORD VersionNo.DateDescription 002024/3/25Original ReportNo.:BLA-EMC-202401-A5102 Page 3 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] TABLEOFCONTENTS 1TESTSUMMARY........................................................................................................................................5 2GENERALINFORMATION.........................................................................................................................6 3GENERALDESCRIPTIONOFE.U.T..........................................................................................................6 4TESTENVIRONMENT................................................................................................................................8 5TESTMODE................................................................................................................................................8 6MEASUREMENTUNCERTAINTY..............................................................................................................8 7DESCRIPTIONOFSUPPORTUNIT..........................................................................................................9 8TESTFACILITY...........................................................................................................................................9 9LABORATORYLOCATION.........................................................................................................................9 10TESTINSTRUMENTSLIST......................................................................................................................10 11CONDUCTEDEMISSIONSATACPOWERLINE(150KHZ-30MHZ).....................................................12 11.1LIMITS................................................................................................................................................................12 11.2BLOCKDIAGRAMOFTESTSETUP......................................................................................................................12 11.3PROCEDURE.......................................................................................................................................................12 11.4TESTDATA...........................................................................................................................................................14 12CONDUCTEDBANDEDGESMEASUREMENT.....................................................................................17 12.1LIMITS................................................................................................................................................................17 12.2BLOCKDIAGRAMOFTESTSETUP......................................................................................................................17 12.3TESTDATA...........................................................................................................................................................17 13RADIATEDSPURIOUSEMISSIONS........................................................................................................18 13.1LIMITS................................................................................................................................................................18 13.2BLOCKDIAGRAMOFTESTSETUP......................................................................................................................19 13.3PROCEDURE.......................................................................................................................................................19 13.4TESTDATA...........................................................................................................................................................21 14RADIATEDEMISSIONSWHICHFALLINTHERESTRICTEDBANDS.................................................30 14.1LIMITS................................................................................................................................................................30 14.2BLOCKDIAGRAMOFTESTSETUP......................................................................................................................31 14.3PROCEDURE.......................................................................................................................................................31 14.4TESTDATA...........................................................................................................................................................33 15CONDUCTEDSPURIOUSEMISSIONS...................................................................................................38 ReportNo.:BLA-EMC-202401-A5102 Page 4 of 60 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd.Tel:+86-755-23059481Email:[email protected] 15.1LIMITS............................................................................................…
Text truncated - open the document above for the full version.
深圳市飞敏科技有限公司 ShenZhen City FeiMin Technology CO.,LTD. Tel: 86-0755-23035723 Fax: 86-0755-23036702 E-mail: [email protected] www.fmant.cn - 1 - FEIMIN OTA antenna data report 1.Model: ZBY-66 Date:2023.05.30 1.1 Test Items Standing wave ratio Gain Efficiency Direction chart 2.T e st Result 2.1 Test conditions Test Environment Conditions: Relative Humindity: 15....75% Temperature: +10°C to +30°C Voltage of the EUT: N/A 2.2 Test Results lists Antenna passive data 深圳市飞敏科技有限公司 ShenZhen City FeiMin Technology CO.,LTD. Tel: 86-0755-23035723 Fax: 86-0755-23036702 E-mail: [email protected] www.fmant.cn - 2 - 2.2.1 SWR 2.2. 2 LOG MAG 深圳市飞敏科技有限公司 ShenZhen City FeiMin Technology CO.,LTD. Tel: 86-0755-23035723 Fax: 86-0755-23036702 E-mail: [email protected] www.fmant.cn - 3 - 2.2. 4 Gain and Efficiency Frequency Gain(dBi) Efficiency 2400MHz -2.1619.85 2410MHz -0.9526.5 2420MHz -0.3430.53 2430MHz -0.0433.07 2440MHz 0.18 34.44 2450MHz 0.16 34.57 2460MHz -0.0932.86 2470MHz -0.4230.59 2480MHz -0.8128.08 2490MHz -1.4923.97 2500MHz -2.2319.86 深圳市飞敏科技有限公司 ShenZhen City FeiMin Technology CO.,LTD. Tel: 86-0755-23035723 Fax: 86-0755-23036702 E-mail: [email protected] www.fmant.cn - 4 - 深圳市飞敏科技有限公司 ShenZhen City FeiMin Technology CO.,LTD. Tel: 86-0755-23035723 Fax: 86-0755-23036702 E-mail: [email protected] www.fmant.cn - 5 - 3 . Manufacturer information Applicant’s name: Shenzhen Jumper Medical Equ ipment Co., Ltd. Address: D Building, No.71, Xintian Road, Fuyong Street, Baoan, Shenzhen, Guan gdong, China 518103
ProductName: ElectronicBloodPressureMonitor RadiatedSpuriousEmissions ConductedEmissionsatACPowerLine(150kHz-30MHz)
Building C, No. 107, Shihuan Road, Shiyan Sub- · Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 820.00 µW |

Pulse Oximeter
Equipment Class
DTS - Digital Transmission System
Electronic Blood Pressure Monitor
Equipment Class
DTS - Digital Transmission System
Pulse Oximeter
Equipment Class
CXX - Communications Rcvr for use w/ licensed Tx and CBs
Body Fat Scale
Equipment Class
DTS - Digital Transmission System
Weight scale
Equipment Class
DTS - Digital Transmission System