FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ShenZhen Jumper Medical Equipment Co.,Ltd/
  3. 2ADYL-JPD-FR409-BT

2ADYL-JPD-FR409-BTInfrared Thermometers

ShenZhen Jumper Medical Equipment Co.,Ltd
Infrared Thermometers - FCC ID 2ADYL-JPD-FR409-BT - ShenZhen Jumper Medical Equipment Co.,Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 15, 2020
Application Purpose
Original Equipment
Date of Application
Jan 15, 2020
Equipment Note
Infrared Thermometers
Frequency Range
2402.00000000 - 2480.00000000
Company
ShenZhen Jumper Medical Equipment Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

JUMPER Health User Manual version1.0 I. Download and Install JUMPER Health 1. Scan the following QR code to download and install. 2. IPhone users may search JUMPER Health in App Store to download. 3. Android phone users may search JUMPER Health in Google Play to download. Note: This APP requires phones of system version above iOS8 or above Android 3.1 to download and install; II. User Registration and Login 1. User Registration JUMPER Health users may register and login by email. When user is registering, make sure to enter the correct E-mail address. If entry error, email error will be displayed. Enter the email and click to continue to enter the verification code entry page. Login your registered email to check the verification code. If error-free, enter the user information setting page, where you must fill in the gender, user name, birthday and height. 2. User Login Upon completion of registration, the registered email will become the login account. Enter the email account and password, and click "Login". If the password is forgotten, you can retrieve the password via email. Upon completion of the first login, you can directly login again without entering the account and password. III. APP Homepage Upon successful login, you will enter the APP homepage, which will mainly display the data monitored by the user recently. Users of different genders will have different homepages. The monitored data displayed on the homepage includes the weight, BMI, FHR, Oximeter and Temperature. Click the icon in the upper left corner to switch, add, delete or edit the home users. I V. Temperature Measurement 1. Select to Measure the Temperature Click "Measure" to enter the measurement page, and select to measure the Temperature. 2. Connect the Thermometer Enter the Temperature measurement page, a pop-up will appear to remind you to initiate the Bluetooth function of mobile phone, and then the mobile phone will search for Bluetooth devices nearby. Click the Bluetooth name of the Thermometer to connect. 3. Temperature Recording Upon successful monitor connection, Body Select the body temperature mode and monitor the temperature at the appropriate location,APP will receive measuring data automatically, And according to the setting of high fever reminder, it will remind for fever, at the same time, it can display the temperature change curve according to Multiple measurements in a period. Note: The normal body temperature range slightly varies with age and gender. Generally, normal body temperature is 36°C/96.8°F~37.4°C /99.3°F, if exceed this range, please consult your doctor. 4. System Setting Click the icon "" to enter the system setting page for display units switch and fever remind. You can click "How to use" to check the instructions. V. V i e w t h e Temperature Record 1. Body temperature data will be saved automatically, Click "History" to enter the records page, where you can view the temperature record. 2. Click the "Temperature Record" to view the detailed record. 3. Click the corresponding record, and you can view the temperature data and body temperature change curve, you also can view the body temperature change condition in different days. VI. Setting 1. You can view the user's profile, health standard, system setting, APP version and logout in the setting. 2. Click "My Profile", and you can set the portrait and country, or revise the name, birthday and height; except registered email-box and gender. 3. Click "system settings", you can set the alarm range.

Users Manual

JPD-FR409-BT InfraredThermometer InstructionManual ShenzhenJumperMedicalEquipmentCo.,Ltd ManualVersion:1.0 DateofIssue:2019.8 0482 ProductInformation ProductName:InfraredThermometer Model:JPD-FR409-BT Manufacturer:ShenzhenJumperMedicalEquipmentCo.,Ltd Address:DBuilding,No.71,XintianRoad,FuyongStreet,Baoan, Shenzhen,Guangdong,China. Copyright Copyright©JumperMedical. Allrightsreserved. Statement ShenzhenJumperMedicalEquipmentCo.,Ltd.ownsandreservesallof therightscomprisedinthecopyrightofthisdocument.Nopartofthis documentmaybechanged,excerpted,copied,reproduced,orimitatedin anyformorbyanymeanswithoutthepriorconsentofShenzhenJumper MedicalEquipmentCo.,Ltd. Allstatements,information,andrecommendationsinthisdocumentare provided"ASIS"withoutwarranties,guaranteesorrepresentationsofany kind,eitherexpressorimplied.Theinformationinthisdocumentis subjecttochangewithoutnotice.ShenzhenJumperMedicalEquipment Co.,Ltd.reservestherightoffinalinterpretationofthisdocument. Introduction ThankyouforpurchasingthisInfraredThermometer.PleasereadtheUser Manualcarefullytomakesuresafeandproperuseofthisthermometer. PleasereadandfullyunderstandtheSafetyPrecautionsbeforeuse. KeeptheInstructionManualwiththisthermometerforfuture reference. Contents FCCStatement................................................................................................1 UnpackingCheck............................................................................................2 PackageContents............................................................................................2 SafetyPrecautions...........................................................................................2 Warning............................................................................................................4 Symbols...........................................................................................................5 BodyTemperatureBasics...............................................................................6 ProductDescription.........................................................................................8 Features............................................................................................................9 Productstructure...........................................................................................10 Displaydescription.......................................................................................10 Soundsandindicatorcolorinstructions.......................................................11 DisplayandOperatingInstructions..............................................................11 MeasuringEarTemperature.........................................................................18 MeasuringForeheadTemperature................................................................20 MeasuringObjectTemperature....................................................................21 ConnectingtheThermometertoanAPPApplicationofaMobilePhone.22 ReplacingBatteries.......................................................................................23 CleaningandDisinfection............................................................................24 Maintenance..................................................................................................25 Troubleshooting.............................................................................................26 Specifications................................................................................................27 SecurityClass................................................................................................28 StorageandTransportation...........................................................................28 EMCInformation-GuidanceandManufacture’sDeclaration....................29 WarrantyandAfter-SaleService..................................................................34 1 FCCStatement Thisdevicecomplieswithpart15oftheFCCRules.Operationissubject tothefollowingtwoconditions: (1)Thisdevicemaynotcauseharmfulinterference. (2)Thisdevicemustacceptanyinterferencereceived,including interferencethatmaycauseundesiredoperation. Notes: Thisequipmenthasbeentestedandfoundtocomplywiththe limitsforaClassBdigitaldevice,pursuanttopart15oftheFCCRules. Theselimitsaredesignedtoprovidereasonableprotectionagainstharmful interferenceinaresidentialinstallation.Thisequipmentgenerates,uses andcanradiateradiofrequencyenergyand,ifnotinstalledandusedin accordancewiththeinstructions,maycauseharmfulinterferencetoradio communications.However,thereisnoguaranteethatinterferencewillnot occurinaparticularinstallation.Ifthisequipmentdoescauseharmful interferencetoradioortelevisionreception,whichcanbedeterminedby turningtheequipmentoffandon,theuserisencouragedtotrytocorrect theinterferencebyoneormoreofthefollowingmeasures: ■Reorientorrelocatethereceivingantenna. ■Increasetheseparationbetweentheequipmentandreceiver. ■Connecttheequipmentintoanoutletonacircuitdifferentfromthatto whichthereceiverisconnected. ■Consultthedealeroranexperiencedradio/TVtechnicianforhelp. Caution:Anychangesormodificationstothisdevicenotexplicitly approvedbymanufacturercouldvoidyourauthoritytooperatethis equipment. 2 UnpackingCheck Pleaseopenthepackagecarefullybeforeuse,checkwhetherall accessoriesareavailableornotandwhetheranycomponentisdamaged duringtransportation,andperforminstallationandoperationfollowingthis usermanual.Incaseofanydamageoroperationproblem,pleasecontact thedealerorcontactJumperdirectly.Youwillneedthefollowing informationwhenmakingyourclaim: devicemodel,serialnumber, purchasedate,andyourcontactinformationandaddress. PackageContents No.NameQuantity 1InfraredThermometer1 2Pouch1 3Battery(AAA)2 4InstructionManual1 SafetyPrecautions Readthefollowingprecautionscarefullybeforeusingthe thermometer. Attention Takecareofthetemperatureprobelens,whichisfragile. Disposeusedbatterieswithcare.Toprotecttheenvironment,you arerecommendedtosendtheusedbatteriestoadesignat…

Text truncated - open the document above for the full version.

Cover Letter(s)

TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: FCC ID: 2ADYL-JPD-FR409-BT · To whom it may concern: Date: 2019-11-15 We, the undersigned, hereby authorize SGS-CSTC Standards Technical Services Co .. Ltd. (SGS) Shenzhen Branch and Jing Song in SGS-CSTC Standards Technical Services Co .. Ltd. (SGS) Shenzhen Branch to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with Shenzhen Jumper Medical Equipment Co., Ltd. This authorization is valid until further written notice from the applicant. Print Name: Vicky Wang Title: RA Manager Signature: On behalf of Company: Shenzhen Jumper Medical Equipment Co.,Ltd. Telephone: 86-7 55-26696279 E-mail: [email protected]

Cover Letter(s)

To: Federal Communications Commission Office of Engineering and Technology Laboratory Division 7435 Oakland Mills Rd. Columbia MD 21046 Regarding: Confidentiality Request regarding application for FCC ID: 2ADYL-JPD-FR409-BT LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commission's rules, the applicant hereby request confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic( s) Block Diagrams Operational Descriptions The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. SHORT TERM CONFIDENTIALITY Additionally, the applicant requests the following documents be held confidential for [O] days from the grant date, whichever is less. If the device is marketed within aforementioned days of the Grant Date, the applicant will notify the TCB per FCC KDB 726920 D01 Confidentiality Request Procedures. External Photos Internal Photos Test Setup Photos User manual(s) Sincerely, Print Name: Vicky Wang Title: RA Manager Signature: I.ft' d{ vJ ""j On behalf of Company: Shenzhen Jumper Medical Equipment Co.,Ltd. Telephone: 86-755-26696279 E-mail: [email protected]

External Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 4 External Photos for SZEM1911020087CR FCC ID: 2ADYL-JPD-FR409-BT SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 4 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 4 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 4

ID Label/Location Info

Model:JPD-FR409-BT (01) 06951740512800 (10) 18090101000 (21) 8329FR40983321 FCC ID:2ADYL-JPD-FR409-BT Model:JPD-FR409-BT FCC ID:2ADYL-JPD-FR409-BT (01) 06951740512800 (10) 18090101000 (21) 8329FR40983321 Label Location

Internal Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 4 Internal Photos for SZEM1911020087CR FCC ID: 2ADYL-JPD-FR409-BT SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 4 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 4 Antenna SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 4

RF Exposure Info

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191102008702 Page: 1 of 7 Keny Xu EMC Laboratory Manager 1 Cover page SAR Evaluation Report Application No.: SZEM1911020087CR Applicant: ShenZhen Jumper Medical Equipment Co., Ltd Address of Applicant: D Building, No. 71, Xintian Road, Fuyong Street, Baoan,Shenzhen, Guangdong,China 518103 Manufacturer: Shenzhen Jumper Medical Equipment Co., Ltd. Address of Manufacturer: Building D, No. 71, Xintian Road, Fuyong Street, Baoan, Shenzhen, Guangdong, P.R. China Factory: Shenzhen Jumper Medical Equipment Co., Ltd. Address of Factory: Building D, No. 71, Xintian Road, Fuyong Street, Baoan, Shenzhen, Guangdong, P.R. China Equipment Under Test (EUT): EUT Name: Infrared Thermometers Model No.: JPD-FR409-BT FCC ID: 2ADYL-JPD-FR409-BT Standards: 47 CFR Part 1.1307 47 CFR Part 2.1093 KDB447498D01 General RF Exposure Guidance v06 Date of Receipt: 2019-11-12 Date of Test: 2019-11-13 to 2019-11-20 Date of Issue: 2019-11-26 Test Result : PASS* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191102008702 Page: 2 of 7 2 Version Revision Record Version Chapter Date Modifier Remark 01 2019-11-26 Original Authorized for issue by: Damon Su /Project Engineer Eric Fu /Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191102008702 Page: 3 of 7 3 Contents Page 1 COVER PAGE .............................................................................................................................................. 1 2 VERSION ...................................................................................................................................................... 2 3 CONTENTS .................................................................................................................................................. 3 4 GENERAL INFORMATION .......................................................................................................................... 4 4.1 GENERAL DESCRIPTION OF EUT ............................................................................................................. 4 4.2 TEST LOCATION ...................................................................................................................................... 5 4.3 TEST FACILITY ........................................................................................................................................ 5 4.4 DEVIATION FROM STANDARDS ................................................................................................................. 6 4.5 ABNORMALITIES FROM STANDARD CONDITIONS ....................................................................................... 6 4.6 OTHER INFORMATION REQUESTED BY THE CUSTOMER ............................................................................. 6 5 SAR EVALUATION ...................................................................................................................................... 7 5.1 RF EXPOSURE COMPLIANCE REQUIREMENT ............................................................................................ 7 5.1.1 Standard Requirement ..................................................................................................................... 7 5.1.2 Limits ................................................................................................................................................ 7 5.1.3 EUT RF Exposure ............................................................................................................................ 7 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191102008702 Page: 4 of 7 4 General Information 4.1 General Description of EUT Power Supply: DC 3.0V by 2*AAA battery. Operation Frequency: 2402MHz to 2480MHz Bluetooth Version: V4.0 Modulation Type: GFSK Number of Channels: 40 Channel Spacing: 2MHz Antenna Type: PCB Antenna Antenna Gain: 0dBi SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191102008702 Page: 5 of 7 4.2 Test Location All tests were performed at: SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong, China 518057 Telephone: +86 (0) 755 2601 2053 Fax: +86 (0) 755 2671 0594 No tests were sub-contracted. 4.3 Test Facility The test facility is recognized, certified, or accredited by the following organizations: • A2LA (Certificate No. 3816.01) SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01. • VCCI The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz, Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have been registered in accordance with the Regulations for Voluntary Control Measures with Registration No.: G-20026, R-14188, C-12383 and T-11153 respectively. • FCC –Designation Number: CN1178 SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized as an accredited testing laboratory. Designation Number: CN1178. Test Firm Registration Number: 406779. • Innovation, Science and Economic Development Canada SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized by ISED as an accredited testing laboratory. CAB identifier: CN0006. IC#: 4620C. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191102008702 Page: 6 of 7 4.4 Deviation from Standards None. 4.5 Abnormalities from Standard Conditions None. 4.6 Other Information Requested by the Customer None. SGS-CSTC Standards Technical Services Co., …

Text truncated - open the document above for the full version.

Test Report

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191102008701 Page: 1 of 52 Keny Xu EMC Laboratory Manager TEST REPORT Application No.: SZEM1911020087CR Applicant: ShenZhen Jumper Medical Equipment Co., Ltd Address of Applicant: D Building, No. 71, Xintian Road, Fuyong Street, Baoan,Shenzhen, Guangdong,China 518103 Manufacturer: Shenzhen Jumper Medical Equipment Co., Ltd. Address of Manufacturer: Building D, No. 71, Xintian Road, Fuyong Street, Baoan, Shenzhen, Guangdong, P.R. China Factory: Shenzhen Jumper Medical Equipment Co., Ltd. Address of Factory: Building D, No. 71, Xintian Road, Fuyong Street, Baoan, Shenzhen, Guangdong, P.R. China Equipment Under Test (EUT): EUT Name: Infrared Thermometers Model No.: JPD-FR409-BT FCC ID: 2ADYL-JPD-FR409-BT Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2019-11-12 Date of Test: 2019-11-13 to 2019-11-20 Date of Issue: 2019-11-26 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191102008701 Page: 2 of 52 Revision Record Version Chapter Date Modifier Remark 01 2019-11-26 Original Authorized for issue by: Damon Su /Project Engineer Eric Fu /Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191102008701 Page: 3 of 52 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Minimum 6dB Bandwidth 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.8.1 47 CFR Part 15, Subpart C 15.247a(2) Pass Conducted Peak Output Power 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.9.1 47 CFR Part 15, Subpart C 15.247(b)(3) Pass Power Spectrum Density 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.10.2 47 CFR Part 15, Subpart C 15.247(e) Pass Conducted Band Edges Measurement 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.13.3.2 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.11 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.4,6.5,6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191102008701 Page: 4 of 52 3 Contents Page 1 COVER PAGE ............................................................................................................................................ 1 2 TEST SUMMARY ....................................................................................................................................... 3 3 CONTENTS ................................................................................................................................................ 4 4 GENERAL INFORMATION ........................................................................................................................ 6 4.1 DETAILS OF E.U.T. ............................................................................................................................... 6 4.2 DESCRIPTION OF SUPPORT UNITS ......................................................................................................... 6 4.3 MEASUREMENT UNCERTAINTY .............................................................................................................. 6 4.4 TEST LOCATION .................................................................................................................................... 7 4.5 TEST FACILITY ...................................................................................................................................... 7 4.6 DEVIATION FROM STANDARDS ............................................................................................................... 7 4.7 ABNORMALITIES FROM STANDARD CONDITIONS ..................................................................................... 7 5 EQUIPMENT LIST ...................................................................................................................................... 8 6 RADIO SPECTRUM TECHNICAL REQUIREMENT ............................................................................... 12 6.1 ANTENNA REQUIREMENT .................................................................................................................... 12 6.1.1 Test Requirement: ....................................................................................................................... 12 6.1.2 Conclusion ................................................................................................................................... 12 7 RADIO SPECTRUM MATTER TEST RESULTS ..................................................................................... 13 7.1 MINIMUM 6DB BANDWIDTH .................................................................................................................. 13 7.1.1 E.U.T. Operation .......................................................................................................................... 13 7.1.2 Test Setup Diagram ..................................................................................................................... 13 7.1.3 Measurement Procedure and Data............................................................................................. 13 7.2 CONDUCTED PEAK OUTPUT POWER .................................................................................................... 14 7.2.1 E.U.T. Operation .............…

Text truncated - open the document above for the full version.

Test Setup Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 3 Setup Photos for SZEM1911020087CR FCC ID: 2ADYL-JPD-FR409-BT SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 3 1 Photographs 1.1 Radiated Spurious Emissions Test Setup SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 3 1.2 Radiated Emissions which fall in the restricted bands

Contact Information

Applicant

Tiffany Zhang(RA manager)
[email protected]86-755-26696279Fax: 86-755-26852025

Technical Contact

SGS-CSTC Standards Technical Services Co., Ltd.Keny Xu
[email protected]86 755 25328629

No.1 Workshop, M-10, Middle Section, · Shenzhen · China

Non-Technical Contact

SGS-CSTC Standards Technical Services Co., Ltd.Jing Song
[email protected]86 755-25328659

Test Firm

SGS-CSTC Standards Technical Services Co., LtdDerek Yang
[email protected]+86 0135 6484 8721

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz600.00 µW
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted.

Other Applications from ShenZhen Jumper Medical Equipment Co.,Ltd

Pulse Oximeter - FCC ID 2ADYL-SPA11 - ShenZhen Jumper Medical Equipment Co.,Ltd
2ADYL-SPA11

Pulse Oximeter

May 20, 2026

Equipment Class

DTS - Digital Transmission System
Electronic Blood Pressure Monitor - FCC ID 2ADYL-JPDHA200C - ShenZhen Jumper Medical Equipment Co.,Ltd
2ADYL-JPDHA200C

Electronic Blood Pressure Monitor

May 15, 2026

Equipment Class

DTS - Digital Transmission System
Pulse Oximeter - FCC ID 2ADYL-JPD500D - ShenZhen Jumper Medical Equipment Co.,Ltd
2ADYL-JPD500D

Pulse Oximeter

Jul 30, 2024

Equipment Class

CXX - Communications Rcvr for use w/ licensed Tx and CBs
Body Fat Scale - FCC ID 2ADYL-JPD-BFS300 - ShenZhen Jumper Medical Equipment Co.,Ltd
2ADYL-JPD-BFS300

Body Fat Scale

Jul 05, 2024

Equipment Class

DTS - Digital Transmission System
Weight scale - FCC ID 2ADYL-JPD-BS300 - ShenZhen Jumper Medical Equipment Co.,Ltd
2ADYL-JPD-BS300

Weight scale

Jul 04, 2024

Equipment Class

DTS - Digital Transmission System