FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. EGLO Hong Kong Lighting Ltd/
  3. 2AEBXET4437

2AEBXET4437Remote Control

EGLO Hong Kong Lighting Ltd
Remote Control - FCC ID 2AEBXET4437 - EGLO Hong Kong Lighting Ltd
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Oct 24, 2023
Application Purpose
Original Equipment
Date of Application
Oct 09, 2023
Equipment Note
Remote Control
Frequency Range
433.92000000 - 433.92000000
Company
EGLO Hong Kong Lighting Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

DATE : 2023.9.22 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2AEBXET4437 Product Name: Remote Control Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: (List here the documents for which you are seeking confidentiality – for example ...) • Schematics • Block diagram • Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. <Signature> Name: Alex.Gu Title: engineer Company: EGLO Hong Kong Lighting Ltd

External Photos

External Photos M/N: ET4437 External Photos M/N: ET4437 External Photos M/N: ET4437

Internal Photos

Internal Photos M/N: ET4437 Internal Photos M/N: ET4437 Internal Photos M/N: ET4437

RF Exposure Info

FCC ID: 2AEBXET4437 EST Technology Co., Ltd Report No. ESTE-R2309016 Page 1 of 3 FCC RF EXPOSURE REPORT EGLO Hong Kong Lighting Ltd Remote control Model Number: ET4437 FCC ID: 2AEBXET4437 Applicant: EGLO Hong Kong Lighting Ltd Address: Rm 1803, 18/F Multifield Centre, 426 Shanghai Street, Mongkok, Kowloon, Hong Kong, China Prepared By: EST Technology Co., Ltd. Chilingxiang, Qishantou, Santun, Houjie, Dongguan, Guangdong, China Tel: 86-769-83081888-808 Report Number: ESTE-R2309016 Date of Test: Jul. 17~Sep. 05, 2023 Date of Report: Sep. 22, 2023 FCC ID: 2AEBXET4437 EST Technology Co., Ltd Report No. ESTE-R2309016 Page 2 of 3 1. Applicable Standards FCC Part 2(Section 2.1093) FCC KDB 447498 D04 Interim General RF Exposure Guidance v01 2. Exposure Evaluation of Portable or Mobile Devices Human exposure to RF emissions from portable devices (47 CFR §2.1093), as defined by the FCC, must be evaluated with respect to the FCC-adopted limits for SAR. Evaluation of mobile devices, as defined by the FCC, may also be performed with respect to SAR limits, but in such cases it is usually simpler and more cost-effective to evaluate compliance with respect to field strength or power density limits. For certain devices that are designed to be used in both mobile and portable configurations similar to those described in 47 CFR §2.1091(d)(4), such as certain desktop phones and wireless modem modules, compliance for mobile configurations is also satisfied when the same device is evaluated for SAR compliance in portable configurations. The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 300 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. FCC ID: 2AEBXET4437 EST Technology Co., Ltd Report No. ESTE-R2309016 Page 3 of 3 3. Evaluation Results Ant gain=3dBi Ant numeric gain=1.99 Field strength = 78.03dBuV/m@3m Limited=2040*f*(0.5/20)^x, x=-log(60/(2040*f*√f))= 23.17mW EIRP={ [10 (78.03 /20) /10 6 *3] 2 / (30*1 }*1000mW =0.0191mW < 23.17mW Note: 1. We choose f=0.43392GHz to calculate MPE limit as higher frequency will have lower MPE limits. 2. SAR Test Exclusion Thresholds is 23.17mW for separation distance 5mm. Therefore, SAR test is not required. End of Test Report

Test Report

FCC ID: 2AEBXET4437 EST Technology Co., Ltd Report No. ESTE-R2309015 Page 1 of 41 FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of EGLO Hong Kong Lighting Ltd Remote control Model Number: ET4437 FCC ID: 2AEBXET4437 Applicant: EGLO Hong Kong Lighting Ltd Address: Rm 1803, 18/F Multifield Centre, 426 Shanghai Street, Mongkok, Kowloon, Hong Kong, China Prepared By: EST Technology Co., Ltd. Chilingxiang, Qishantou, Santun, Houjie, Dongguan, Guangdong, China Tel: 86-769-83081888-808 Report Number: ESTE-R2309015 Date of Test: Jul. 17~Sep. 05, 2023 Date of Report: Sep. 22, 2023 FCC ID: 2AEBXET4437 EST Technology Co., Ltd Report No. ESTE-R2309015 Page 2 of 41 TABLE OF CONTENTS Description Page TEST REPORT VERIFICATION......................................................................................................................... 3 1. GENERAL INFORMATION ................................................................................................................. 5 1.1. Description of Device (EUT) ........................................................................................................... 5 1.2. Antenna Information ........................................................................................................................ 5 1.3. Information of RF Cable .................................................................................................................. 5 2. SUMMARY OF TEST ......................................................................................................................... 6 2.1. Summary of test result ...................................................................................................................... 6 2.2. Test Facilities ................................................................................................................................... 7 2.3. Measurement uncertainty ................................................................................................................. 8 2.4. Assistant equipment used for test ..................................................................................................... 8 2.5. Block Diagram ................................................................................................................................. 8 2.6. Test Mode ......................................................................................................................................... 9 2.7. Channel List ..................................................................................................................................... 9 2.8. Test Equipment List ....................................................................................................................... 10 3. DUTY CYCLE ................................................................................................................................ 12 3.1. Limit ............................................................................................................................................... 12 3.2. Test Setup ....................................................................................................................................... 12 3.3. Spectrum Analyzer Setting ............................................................................................................. 12 3.4. Test Procedure ................................................................................................................................ 12 3.5. Test Conditions ............................................................................................................................... 13 3.6. Test Result ...................................................................................................................................... 13 4. FIELD STRENGTH OF FUNDAMENTAL ............................................................................................ 15 4.1. Limit ............................................................................................................................................... 15 4.2. Test Setup ....................................................................................................................................... 16 4.3. Spectrum Analyzer Setting ............................................................................................................. 16 4.4. Test Procedure ................................................................................................................................ 16 4.5. Test Result ...................................................................................................................................... 17 5. RADIATED SPURIOUS EMISSIONS .................................................................................................. 20 5.1. Limit ............................................................................................................................................... 20 5.2. Test Setup ....................................................................................................................................... 22 5.3. Spectrum Analyzer Setting ............................................................................................................. 23 5.4. Test Procedure ................................................................................................................................ 24 5.5. Test Result ...................................................................................................................................... 25 6. 20DB BANDWIDTH ........................................................................................................................ 30 6.1. Limit ............................................................................................................................................... 30 6.2. Test Setup ...............................................................…

Text truncated - open the document above for the full version.

Test Report

Frequency: 433.92MHz Ant gain: 3dBi Modu lation: ASK KEY number: 19 standby current: 3V Antenna manufacturer: The antenna is laid out on the PCB board. PCB manufacturer information: 1. JIANG MEN CHANG MING PCB Factory BEI TOU ZUI INDUSTRIAL ZONE LI LE TOWN, LI YI RD.JIANG HAI JIANGMEN, Guangdong Sheng 529060 China model: CM-2 2. ZHUHAI JIE SUN PRICION PCB CO LTD NO 210 ANJI EAST RD CHAOTANWAN SANZAO TOWN JINWAN DISTRICT ZHUHAI, Guangdong Sheng 519040 China model:JS

Test Setup Photos

Radiated Test (Below 1GHz) Radiated Test (Above 1GHz)

Contact Information

Applicant

Alex Gu(Engineer)
[email protected]852 2783 0807Fax: 852 2783 0821

Test Firm

EST Technology Co., Ltd.Iceman Hu
[email protected]+86 0769-83081888

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term

Other Applications from EGLO Hong Kong Lighting Ltd

Remote Control - FCC ID 2AEBXET4379 - EGLO Hong Kong Lighting Ltd
2AEBXET4379

Remote Control

Oct 24, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote Control - FCC ID 2AEBXET4470 - EGLO Hong Kong Lighting Ltd
2AEBXET4470

Remote Control

Oct 24, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote Control - FCC ID 2AEBXET4271 - EGLO Hong Kong Lighting Ltd
2AEBXET4271

Remote Control

Oct 24, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote control - FCC ID 2AEBXRF-21-A - EGLO Hong Kong Lighting Ltd
2AEBXRF-21-A

Remote control

Jun 02, 2015

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter