Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Smart IR Controller ‐ Manual Product name: Smart IR Controller Product description: this is one of the components of USUNG SmartHome System, and it must work with other SmartHome components. It can replace various remote controllers to control different infrared devices such as air conditioners, TVs, DVDs, etc. Installation& Usage: 1. Put the infrared controller in upside down position, and turn its bottom cover counterclockwisely and open it; 2. Take out the VII two AAA alkaline batteriesfromthe package, and insert the batteries properly by following the positive/negative terminal marks. 3. Aligning the notch on the bottom cover to the protrusion on top cover of the Controller, drop the cover and turn it clockwisely; 4. Place directly, or use the foam tape come up with the product package to fix, the Infrared Controller to a proper position; Illustration: Precautions: 1. Please charge the batteries with the charger come up with the product, and please DO NOT try to charge a non‐chargeable battery, as may lead to battery leakage, product damage or personal injury; 2. Please charge using the power adapter come up with the product; 3. Please do not disassemble or try to repair the product in your own will; 4. Please do not put the product under extreme conditions like high temperature or high pressure , etc.; 5. Please keep the product away from baby or child; 6. Please keep the product dry and away from humidity; 7. The product ID can be seen at the inner side of the bottom cover. You may find it when open the bottom cover by turning it counterclockwisely and you Xiamen Tongren IOT Technology Co.,Ltd. 24Hr hotline service:4008888022 Website:http://home.iusung.com Smart Home Initial Configuration and User Manual Software Login Configuration z Firstly, please follow the user manual, correctly install the Smart Gateway and other smart components, and power them on. Please make backup and memo for each device during the installation in accordance with the description of the attached ID Backup Table. z Secondly, download and install the SmartHome Suite Client Software from USUNG SmartHome System Official Website(downloading url: http://home.iusung.com/download ), or you may use a barcode scanner tool from your mobile to check out the downloading address from the 2D barcode shown below. Note: There are various 2D barcode scanner tools available for mobiles, such as Wechat. Take Wechat for example: select Discover -> choose Scan (if not available, please enable the Scan tool in the Settings) z Then, on your mobile, enter Settings Æ Wireless LAN, find the AP named like“WIMA******” z Open the client software, from the Login interface , click on the “Initial Usage Wizard”and enter the Router Configuration interface; z In Router Configuration interface, click on Confirmation button, and you will be redirect to your mobile phone’s default browser, where you can login to the Smart Gateway (with“admin”as both default username and password ); z Once logged in successfully, by following the interface requests, enter the SSID of your Home WIFI, and please write down the MAC address shown in the page that followed, which will be used in remote Controlling Settings Or by auto-scanning using Scanning Hotspot function, you may choose the SSID of your Home WIFI. z Input the password for your home WIFI; Click Save button to save the settings data. Click Return to go back to the Router Configuration interface. and then click on Return complete the settings. z After completion of the above configuration, the Smart Gateway should have joined your home WIFI. Now, if your mobile has not yet connected to your home WIFI automatically, please open the Settings Æ Wireless LAN, and connect your mobile again to your home WIFI. z Reopen your mobile client software and go back to the login interface; The client software will automatically search the Smart Gateway that joined already in your home WIFI, and display it (or them) in the login list. (This process will last for 10-60 seconds, be patient please. If it takes too long to find your WIFI, please press down the reset button at the back of the gateway for 6 seconds to reset the gateway and then you may start the configuration from the start again. z After completion of the search , please choose the gateway that you want to login and input the password for the gateway (default is the initial 8 digits of the gateway’s ID ). Login! Congratulations! You’ve finished the settings, now you can use your SmartHome System. Note: z Once completed above setting procedures, you may not change above initial settings through the gateway’s built-in WIFI network directly, unless reset the gateway. z After completion of above setting procedures, if your other family members need to control the SmartHome system by using the mobile client software through the home WIFI, they are not required to repeat above configuration but only to login with gateway password. z When using the Mobile Client Software, please keep live the connection to the wireless LAN of your home router. z If you changed the home WIFI router, you need to reset the gateway (for guidance please refer to the product manual), and repeat the configurations described in this manual. Using APP Software z Naming and Area Definition Please confirm firstly that you have correctly installed and powered on all smart components. Open the SmartHome APP software and login , in the main interface, click on My Settings. In My Settings interface, click to open the Online Device, where you see all installed smart components. The default name of a newly added device is its ID. Click on any device, in the popup menu, you can rename the device and assign an area to it.(if you have marked down the information of the device such as installation location etc. by using the suite attached ID Backup Table, you may now take advantage of it) After completion of the settings, please click on Save button on the top-right corner. z Usin…
Text truncated - open the document above for the full version.
Xiamen Tongren IOT Technology Co.,Ltd 4F-A, Block A, Huaxun Buliding, Software Park, Torch Hi-tech Zone, Xiamen, China FCC Agent Authorisation Template 22-01-2015 TUV SUD BABT TCB Octagon House, Segensworth Road, Fareham, Hampshire, PO15 5RL Dear Sir or Madam, We, (Xiamen Tongren IOT Technology Co.,Ltd.; 4F-A, Block A, Huaxun Buliding, Software Park, Torch Hi-tech Zone, Xiamen, China), hereby authorize (Shenzhen Microtest Technology Co.,Ltd;Lisa Li) to act as our agent in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. This authorization expires on (Jan. 22, 2016). Sincerely, Company Officer: Telephone Number: 0592-3929702 Email: [email protected] FCC Agent Authorisation
Xiamen Tongren IOT Technology Co.,Ltd 4F-A, Block A, Huaxun Buliding, Software Park, Torch Hi-tech Zone, Xiamen, China FCC Confidentiality Template 22-01-2015 TUV SUD BABT TCB Octagon House, Segensworth Road, Fareham, Hampshire, PO15 5RL Confidentiality Request FCC ID: 2AEEDUS-IC101 Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, (Xiamen Tongren IOT Technology Co.,Ltd.) hereby requests permanent confidential treatment of information accompanying this application as outlined below: - Block Diagram - Schematics - Operational Description (Xiamen Tongren IOT Technology Co.,Ltd) also hereby requests short-term confidential treatment of information accompanying this application as outlined below for a period of (up to 180) days: -Internal Photos -External Photos -User Manual -Test Set-up Photographs The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Yours sincerely, Company Officer: Telephone Number: 0592-3929702 Email: [email protected] FCC Confidentiality
APPENDIX-PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS Photo 1 Photo 2 Photo 3 Photo 4
3.0*1.0cm Model: US-IC101 FCC ID: 2AEEDUS-IC101
Photo 5 Photo 6 Photo 7 Photo 8 Photo 9 Photo 10 Photo 11 Photo 12 Zigbee ANT Photo 13
RF EXPOSURE TEST FCC ID: 2AEEDUS-IC101 Applied procedures / limit These devices are not exempted from compliance does not exceed the Commission’s RF exposure guidelines.Unless a device operates at substantially low power levels,with a low gain antenna(s),supporting information is generally needed to establish the various potential operating configurations and exposure conditions of a transmitter and its antenna(s) in order to determine compliance with the RF exposure guidelines. In order to demonstrate compliance with MPE requirement(see Section 2.1091),the following information is typically needed: Calculation that estimates the minimum separation distance(20 cm or more)between an antenna and persons required to satisfy power density limits defined for free space. Antenna installation and device operating instructions for installers(professional/unskilled users),and the parties responsible for ensuring compliance with the RF exposure requirement Any caution statements and/or warming labels that are necessary in order to comply with the exposure limits Any other RF exposure related issues that may affect MPE compliance. FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environmental impact of human exposure to radio-frequency(RF) radiation as specified in 1.1307(b). (A) Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842 / f 4.89 / f (900 / f)* 6 30-300 61.4 0.163 1.0 6 300-1500 F/300 6 1500-100,000 5 6 (B) Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f)* 30 30-300 27.5 0.073 0.2 30 300-1500 F/1500 30 1500-100,000 1.0 30 Note: f = frequency in MHz ; *Plane-wave equivalent power density MPE CALCULATION METHOD Calculation Method of RF Safety Distance: P :power input to the antenna in Mw EIRP :Equivalent(effective) isotropic radiated power. S :power density mW/ cm 2 G ;numeric gain of antenna relative to isotropic radiator R :distance to centre of radiation in cm FCC radio frequency exposure limits may be exceeded at distances closer than r cm from the antenna of this device EIRP=10 ( Antenna Gain+Peak Output Power/10) Note: 1. s=1.0 mW /cm 2 for limits for General Population/Uncontrolled Exposures. 2. The time averaged power over 30 minutes will be equaled Output Power. 3. The Power Density at a distance of 20cm calculated from the formula is far below the limit of 1MW/ cm 2 TEST RESULTS NOTE: (For mobile or fixed location transmitters, the maximum power density is 1.0mW/cm 2 even if the calculation indicates that the power density would be larger) PK output power (MAX) (dBm) Output power to antenna (mW) Antenna Gain (numeric) Power Density (S) (mW/ cm 2 ) Limit of Power Density (S) (mW/ cm 2 ) Result 9.51 8.93 1.585(2.0dbi) 0.0028 1 Pass
4F- T R T R A T P Note: Thi s not Xia -A, Block This Repo Origina Report Num Test Engine Reviewed B Approved & Test Date: repared B y s test report be duplica t Me amen To k A, Huax F ort Conce al Report mber: eer: By: & Authorize y: is limited to ted without FCC easurem Tongren xun Bulid Xi FCC ID: J rns: E S M B J ed By: H J S 6 a T F o the above prior written C Part ment And For n IOT Te ing, Softw amen, C 2AEED Jan. 17, 20 Equipmen Smart IR C MTI14120 Bill Chen Jason Z Hebe Le Jan. 05 - J Shenzhen 6F, Zhongba an District, S Tel: +86-755 Fax: +86-75 e client com n consent o t 15C d Te s t R echnolo ware Par hina. DUS-IC1 015 nt Type: Controller 4002RF heng e Jan. 17, 2 Microtest ao Building, Shenzhen, 5-8885 0135 55-8885 013 pany and th f Shenzhen eport ogy Co rk, Torch 01 r 2015 t Technolo , Gushu, Ba P.R.China 5 36 he product n Microtest T .,Ltd. Hi-tech Z ogy Co.,Lt ao' model only. Technology Zone, td . It may y Co.,Ltd. Report No.:MTI141204002RF Page 2 of 38 TEST RESULT CERTIFICATION Applicant’s name ................. : Xiamen Tongren IOT Technology Co.,Ltd. Address .................................. : 4F-A, Block A, Huaxun Buliding, Software Park, Torch Hi-tech Zone, Xiamen, China. Manufacture's Name ............ : Xiamen Tongren IOT Technology Co.,Ltd. Address .................................. : 4F-A, Block A, Huaxun Buliding, Software Park, Torch Hi-tech Zone, Xiamen, China. Product description Product name ............................: Smart IR Controller Model and/or type reference : US-IC101 Serial Model ...............................: N/A Standards ............................. : FCC Part15.247 Test procedure .............................ANSI C63.4-2003 Report No.:MTI141204002RF Page 3 of 38 Table of Contents Page 1 . SUMMARY OF TEST RESULTS 5 1.1 TEST FACILITY 6 1.2 MEASUREMENT UNCERTAINTY 6 2 . GENERAL INFORMATION 7 2.1 GENERAL DESCRIPTION OF EUT 7 2.2 DESCRIPTION OF TEST MODES 9 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 10 2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) 11 2.5 EQUIPMENTS LIST FOR ALL TEST ITEMS 12 3 . EMC EMISSION TEST 13 3.1 CONDUCTED EMISSION MEASUREMENT 13 3.1.1 POWER LINE CONDUCTED EMISSION LIMITS 13 3.1.2 TEST PROCEDURE 14 3.1.3 DEVIATION FROM TEST STANDARD 14 3.1.4 TEST SETUP 14 3.1.5 EUT OPERATING CONDITIONS 14 3.1.6 TEST RESULTS 15 3.2 RADIATED EMISSION MEASUREMENT 16 3.2.1 RADIATED EMISSION LIMITS 16 3.2.2 TEST PROCEDURE 17 3.2.3 DEVIATION FROM TEST STANDARD 17 3.2.4 TEST SETUP 18 3.2.5 EUT OPERATING CONDITIONS 19 3.2.6 TEST RESULTS (BETWEEN 9KHZ – 30 MHZ) 20 3.2.7 TEST RESULTS (BETWEEN 30MHZ – 1GHZ) 21 3.2.8 TEST RESULTS (ABOVE 1000 MHZ) 22 4 . POWER SPECTRAL DENSITY TEST 27 4.1 APPLIED PROCEDURES / LIMIT 27 4.1.1 TEST PROCEDURE 27 4.1.2 DEVIATION FROM STANDARD 27 4.1.3 TEST SETUP 27 4.1.4 EUT OPERATION CONDITIONS 27 4.1.5 TEST RESULTS 28 5 . BANDWIDTH TEST 30 5.1 APPLIED PROCEDURES / LIMIT 30 5.1.1 TEST PROCEDURE 30 5.1.2 DEVIATION FROM STANDARD 30 Report No.:MTI141204002RF Page 4 of 38 Table of Contents Page 5.1.3 TEST SETUP 30 5.1.4 EUT OPERATION CONDITIONS 30 5.1.5 TEST RESULTS 31 6 . PEAK OUTPUT POWER TEST 33 6.1 APPLIED PROCEDURES / LIMIT 33 6.1.1 TEST PROCEDURE 33 6.1.2 DEVIATION FROM STANDARD 33 6.1.3 TEST SETUP 33 6.1.4 EUT OPERATION CONDITIONS 33 6.1.5 TEST RESULTS 34 7 . 100 KHZ BANDWIDTH OF FREQUENCY BAND EDGE 35 7.1 DEVIATION FROM STANDARD 35 7.2 TEST SETUP 35 7.3 EUT OPERATION CONDITIONS 35 7.4 TEST RESULTS 36 8 . ANTENNA REQUIREMENT 38 8.1 STANDARD REQUIREMENT 38 8.2 EUT ANTENNA 38 Report No.:MTI141204002RF Page 5 of 38 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15 (15.247) , Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission N/A 15.247 (a)(2) 6dB Bandwidth PASS 15.247 (b) Peak Output Power PASS 15.247 (c) Radiated Spurious Emission PASS 15.247 (d) Power Spectral Density PASS 15.205 Band Edge Emission PASS 15.203 Antenna Requirement PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Report No.:MTI141204002RF Page 6 of 38 1.1 TEST FACILITY Shenzhen Toby Technology Co., Ltd. Add.: 10/F.,A Block,Jiada R&D Bldg.,No.5 Songpingshan, Road, Science&Technology Park, Shenzhen, 518057 FCC Registration No.:811562 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 No. Item Uncertainty 1 Conducted Emission Test ±1.38dB 2 RF power,conducted ±0.16dB 3 Spurious emissions,conducted ±0.21dB 4 All emissions,radiated(<1G) ±4.68dB 5 All emissions,radiated(>1G) ±4.89dB 6 Temperature ±0.5°C 7 Humidity ±2% Report No.:MTI141204002RF Page 7 of 38 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF EUT Equipment Smart IR Controller Trade Name USUNG Model Name US-IC101 Serial Model N/A Model Difference N/A Product Description The EUT is a Smart IR Controlle r Operation Frequency: 2405~2480 MHz,(Channel Number:16, Channel Frequency=2405+5(K-1), K=1,2,3...16) Modulation Type: O-QPSK Number Of Channel 16CH Antenna Designation: Please see Note 3. Output Power(Conducted): 9.51dBm (Max.) Antenna Gain (dBi) 2.0dbi Based on the application, features, or specification exhibited in User's Manual, the EUT is considered as an ITE/Computing Device. More details of EUT technical specification, please refer to the User's Manual. Channel List Please refer to the Note 2. Adapter N/A Battery DC 3V Connecting I/O Port(s) Please refer to the User's Manual Note: 1. For a more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. Report No.:MTI141204002RF Page 8 of 38 2. Channel List for 802.15.4 Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) 01 2405 05 2425 09 2445 13 2465 02 2410 06 2430 10 2450 14 2470 03 2415 07 2435 11 2455 15 2475 04 2420 08 2440 12 2460 16 2480 3. Table for Filed Antenna…
Text truncated - open the document above for the full version.
Report No.:MTI141204002RF Page 39 of 39 9. EUT TEST PHOTO Radiated Measurement Photos
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 8.90 mW |

Smart Gateway
Equipment Class
DTS - Digital Transmission SystemSmart Surveillance Camera
Equipment Class
DTS - Digital Transmission System
Smart Power Controller
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterSmart Switch Panel
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter