FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Xiamen Tongren IOT Technology Co.,Ltd./
  3. 2AEEDUS-SP101

2AEEDUS-SP101Smart Switch Panel

Xiamen Tongren IOT Technology Co.,Ltd.

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Apr 19, 2015
Application Purpose
Original Equipment
Date of Application
Apr 19, 2015
Equipment Note
Smart Switch Panel
Frequency Range
2405.00000000 - 2480.00000000
Company
Xiamen Tongren IOT Technology Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

SmartHome – Wireless Smart Switch Panel – Manual Product name: SmartHome – Wireless Smart Switch Panel Product description: This is one of the USUNG SmartHome System components, and must work together with other SmartHome components. It is a component that controls power ON/OFF status of certain device. Based on wireless technology and is powered by button-battery, it is very power efficient and may serve with a long standby time (the button batteries may serve up to more than 12 months). In package: switch panel x1; button battery x2, user manual x1. Installation & Usage: 1. Put the Switch Panel horizontally, and use a needle or some other tools to prod into the tiny hole to the bottom right of the button, so as to eject the battery slot; 2. Take off the insulation sheets at back of the button batteries first, and insert the batteries to the slot and push the slot back and close it tightly; 3. Use the foam tape come up with the product to stick the switch panel to a proper position; 4. Installation completes. Illustration: Precautions: 1. Please do not disassemble or try to repair the product in your own will; 2. Please do not put the product under extreme conditions like high temperature or high pressure, etc.; 3. Please install the batteries properly in correct terminal orientation; 4. Please keep the product away from baby or child; 5. Please keep the product dry and away from humidity; Smart Home Initial Configuration and User Manual Software Login Configuration z Firstly, please follow the user manual, correctly install the Smart Gateway and other smart components, and power them on. Please make backup and memo for each device during the installation in accordance with the description of the attached ID Backup Table. z Secondly, download and install the SmartHome Suite Client Software from USUNG SmartHome System Official Website(downloading url: http://home.iusung.com/download ), or you may use a barcode scanner tool from your mobile to check out the downloading address from the 2D barcode shown below. Note: There are various 2D barcode scanner tools available for mobiles, such as Wechat. Take Wechat for example: select Discover -> choose Scan (if not available, please enable the Scan tool in the Settings) z Then, on your mobile, enter Settings Æ Wireless LAN, find the AP named like“WIMA******” z Open the client software, from the Login interface , click on the “Initial Usage Wizard”and enter the Router Configuration interface; z In Router Configuration interface, click on Confirmation button, and you will be redirect to your mobile phone’s default browser, where you can login to the Smart Gateway (with“admin”as both default username and password ); z Once logged in successfully, by following the interface requests, enter the SSID of your Home WIFI, and please write down the MAC address shown in the page that followed, which will be used in remote Controlling Settings Or by auto-scanning using Scanning Hotspot function, you may choose the SSID of your Home WIFI. z Input the password for your home WIFI; „ Click Save button to save the settings data. „ Click Return to go back to the Router Configuration interface. „ and then click on Return complete the settings. z After completion of the above configuration, the Smart Gateway should have joined your home WIFI. Now, if your mobile has not yet connected to your home WIFI automatically, please open the Settings Æ Wireless LAN, and connect your mobile again to your home WIFI. z Reopen your mobile client software and go back to the login interface; The client software will automatically search the Smart Gateway that joined already in your home WIFI, and display it (or them) in the login list. (This process will last for 10-60 seconds, be patient please. If it takes too long to find your WIFI, please press down the reset button at the back of the gateway for 6 seconds to reset the gateway and then you may start the configuration from the start again. z After completion of the search , please choose the gateway that you want to login and input the password for the gateway (default is the initial 8 digits of the gateway’s ID ). Login! Congratulations! You’ve finished the settings, now you can use your SmartHome System. Note: z Once completed above setting procedures, you may not change above initial settings through the gateway’s built-in WIFI network directly, unless reset the gateway. z After completion of above setting procedures, if your other family members need to control the SmartHome system by using the mobile client software through the home WIFI, they are not required to repeat above configuration but only to login with gateway password. z When using the Mobile Client Software, please keep live the connection to the wireless LAN of your home router. z If you changed the home WIFI router, you need to reset the gateway (for guidance please refer to the product manual), and repeat the configurations described in this manual. Using APP Software z Naming and Area Definition „ Please confirm firstly that you have correctly installed and powered on all smart components. „ Open the SmartHome APP software and login , in the main interface, click on My Settings. „ In My Settings interface, click to open the Online Device, where you see all installed smart components. „ The default name of a newly added device is its ID. Click on any device, in the popup menu, you can rename the device and assign an area to it.(if you have marked down the information of the device such as installation location etc. by using the suite attached ID Backup Table, you may now take advantage of it) „ After completion of the settings, please click on Save button on the top-right corner. z Using Smart Power Controller „ Before start using, please make sure you have correctly installed the Smart Power Controller strictly following the attached Product Manual. „ Then, please go back to the home interface of the software, click on Online Devices button to enter the Onl…

Text truncated - open the document above for the full version.

Cover Letter(s)

Xiamen Tongren IOT Technology Co.,Ltd 4F-A, Block A, Huaxun Buliding, Software Park, Torch Hi-tech Zone, Xiamen, China FCC Agent Authorisation Template 22-01-2015 TUV SUD BABT TCB Octagon House, Segensworth Road, Fareham, Hampshire, PO15 5RL Dear Sir or Madam, We, (Xiamen Tongren IOT Technology Co.,Ltd.; 4F-A, Block A, Huaxun Buliding, Software Park, Torch Hi-tech Zone, Xiamen, China), hereby authorize (Shenzhen Microtest Technology Co.,Ltd;Lisa Li) to act as our agent in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. This authorization expires on (Jan. 22, 2016). Sincerely, Company Officer: Telephone Number: 0592-3929702 Email: [email protected] FCC Agent Authorisation

Cover Letter(s)

Xiamen Tongren IOT Technology Co.,Ltd 4F-A, Block A, Huaxun Buliding, Software Park, Torch Hi-tech Zone, Xiamen, China FCC Confidentiality Template 22-01-2015 TUV SUD BABT TCB Octagon House, Segensworth Road, Fareham, Hampshire, PO15 5RL Confidentiality Request FCC ID: 2AEEDUS-SP101 Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, (Xiamen Tongren IOT Technology Co.,Ltd.) hereby requests permanent confidential treatment of information accompanying this application as outlined below: - Block Diagram - Schematics - Operational Description (Xiamen Tongren IOT Technology Co.,Ltd) also hereby requests short-term confidential treatment of information accompanying this application as outlined below for a period of (up to 180) days: -Internal Photos -External Photos -User Manual -Test Set-up Photographs The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Yours sincerely, Company Officer: Telephone Number: 0592-3929702 Email: [email protected] FCC Confidentiality

External Photos

APPENDIX-PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS Photo 1 Photo 2 Photo 3 Photo 4 Photo 5 Photo 6 Photo 7

ID Label/Location Info

4.0*2.0cm Model: US‐SP101 FCC ID: 2AEEDUS‐SP101

Internal Photos

Photo 1 Photo 2 Photo 3 Photo 4 ZEGBEE ANT Photo 5

RF Exposure Info

RF EXPOSURE TEST FCC ID: 2AEEDUS-SP101 Applied procedures / limit These devices are not exempted from compliance does not exceed the Commission’s RF exposure guidelines.Unless a device operates at substantially low power levels,with a low gain antenna(s),supporting information is generally needed to establish the various potential operating configurations and exposure conditions of a transmitter and its antenna(s) in order to determine compliance with the RF exposure guidelines. In order to demonstrate compliance with MPE requirement(see Section 2.1091),the following information is typically needed: Calculation that estimates the minimum separation distance(20 cm or more)between an antenna and persons required to satisfy power density limits defined for free space. Antenna installation and device operating instructions for installers(professional/unskilled users),and the parties responsible for ensuring compliance with the RF exposure requirement Any caution statements and/or warming labels that are necessary in order to comply with the exposure limits Any other RF exposure related issues that may affect MPE compliance. FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environmental impact of human exposure to radio-frequency(RF) radiation as specified in 1.1307(b). (A) Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842 / f 4.89 / f (900 / f)* 6 30-300 61.4 0.163 1.0 6 300-1500 F/300 6 1500-100,000 5 6 (B) Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f)* 30 30-300 27.5 0.073 0.2 30 300-1500 F/1500 30 1500-100,000 1.0 30 Note: f = frequency in MHz ; *Plane-wave equivalent power density MPE CALCULATION METHOD Calculation Method of RF Safety Distance: P :power input to the antenna in Mw EIRP :Equivalent(effective) isotropic radiated power. S :power density mW/ cm 2 G ;numeric gain of antenna relative to isotropic radiator R :distance to centre of radiation in cm FCC radio frequency exposure limits may be exceeded at distances closer than r cm from the antenna of this device EIRP=10 ( Antenna Gain+Peak Output Power/10) Note: 1. s=1.0 mW /cm 2 for limits for General Population/Uncontrolled Exposures. 2. The time averaged power over 30 minutes will be equaled Output Power. 3. The Power Density at a distance of 20cm calculated from the formula is far below the limit of 1MW/ cm 2 TEST RESULTS NOTE: (For mobile or fixed location transmitters, the maximum power density is 1.0mW/cm 2 even if the calculation indicates that the power density would be larger) PK output power (MAX) (dBm) Output power to antenna (mW) Antenna Gain (numeric) Power Density (S) (mW/ cm 2 ) Limit of Power Density (S) (mW/ cm 2 ) Result 9.45 8.81 1.585(2.0dbi) 0.0028 1 Pass

RF Exposure Info

FCC ID : 2AEEDUS-SP101 RF EXPOSURE EVALUATION METHOD SAR Test Exclusion Thresholds for 100 MHz – 6 GHz and ≤ 50 mm Approximate SAR Test Exclusion Power Thresholds at Selected Frequencies and Test Separation Distances are illustrated in the following Table. The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. FCC ID : 2AEEDUS-SP101 Maximum measured transmitter power. frequency Maximum Peak Conducted Output Power Max Antenna Gain GHz dBm dBi 2.405 9.45 2.0 Remark: The best case gain of the antenna is 2.0dBi. 2.0dBi logarithmic terms convert to numeric result is nearly 1.58 9.45dbm=8.81mW [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 8.81/5*√2.405=2.73≤3.0 Threshold at which no SAR required is 10mw and ≤ 3.0 for 1-g SAR, Separation distance is 5mm. Conclusion: No SAR is required.

Test Report

4F- T R T R A T P Note: Thi s not Xia -A, Block This Repo Origina Report Num Test Engine Reviewed B Approved & Test Date: repared B y s test report be duplica t Me amen T k A, Huax F ort Conce al Report mber: eer: By: & Authorize y: is limited to ted without FCC easurem Tongren xun Bulid Xi FCC ID: J rns: E S M B J ed By: H J S 6 a T F o the above prior written C Part ment And For n IOT Te ing, Softw amen, C 2AEED Jan. 15, 20 Equipmen Smart Swi MTI14120 Bill Chen Jason Z Hebe Le Jan. 04 - J Shenzhen 6F, Zhongba an District, S Tel: +86-755 Fax: +86-75 e client com n consent o t 15C d Te s t R echnolo ware Par hina. US-SP1 015 nt Type: tch Panel 4004RF heng e Jan. 15, 2 Microtest ao Building, Shenzhen, 5-8885 0135 55-8885 013 pany and th f Shenzhen eport ogy Co rk, Torch 101 2015 t Technolo , Gushu, Ba P.R.China 5 36 he product n Microtest T ., Ltd Hi-tech Z ogy Co.,Lt ao' model only. Technology Zone, td . It may y Co.,Ltd. Report No.:MTI141204004RF Page 2 of 39 TEST RESULT CERTIFICATION Applicant’s name ................. : Xiamen Tongren IOT Technology Co., Ltd Address .................................. : 4F-A, Block A, Huaxun Buliding, Software Park, Torch Hi-tech Zone, Xiamen, China Manufacture's Name ............ : Xiamen Tongren IOT Technology Co., Ltd Address .................................. : 4F-A, Block A, Huaxun Buliding, Software Park, Torch Hi-tech Zone, Xiamen, China Product description Product name ............................: Smart Switch Panel Model and/or type reference : US-SP101 Serial Model ...............................: N/A Standards ............................. : FCC Part15.247 Test procedure .............................ANSI C63.4-2003 Report No.:MTI141204004RF Page 3 of 39 Table of Contents Page 1 . SUMMARY OF TEST RESULTS 5 1.1 TEST FACILITY 6 1.2 MEASUREMENT UNCERTAINTY 6 2 . GENERAL INFORMATION 7 2.1 GENERAL DESCRIPTION OF EUT 7 2.2 DESCRIPTION OF TEST MODES 9 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 10 2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) 11 2.5 EQUIPMENTS LIST FOR ALL TEST ITEMS 12 3 . EMC EMISSION TEST 13 3.1 CONDUCTED EMISSION MEASUREMENT 13 3.1.1 POWER LINE CONDUCTED EMISSION LIMITS 13 3.1.2 TEST PROCEDURE 14 3.1.3 DEVIATION FROM TEST STANDARD 14 3.1.4 TEST SETUP 14 3.1.5 EUT OPERATING CONDITIONS 14 3.1.6 TEST RESULTS 15 3.2 RADIATED EMISSION MEASUREMENT 16 3.2.1 RADIATED EMISSION LIMITS 16 3.2.2 TEST PROCEDURE 17 3.2.3 DEVIATION FROM TEST STANDARD 17 3.2.4 TEST SETUP 18 3.2.5 EUT OPERATING CONDITIONS 19 3.2.6 TEST RESULTS (BETWEEN 9KHZ – 30 MHZ) 20 3.2.7 TEST RESULTS (BETWEEN 30MHZ – 1GHZ) 21 3.2.8 TEST RESULTS (ABOVE 1000 MHZ) 22 4 . POWER SPECTRAL DENSITY TEST 27 4.1 APPLIED PROCEDURES / LIMIT 27 4.1.1 TEST PROCEDURE 27 4.1.2 DEVIATION FROM STANDARD 27 4.1.3 TEST SETUP 27 4.1.4 EUT OPERATION CONDITIONS 27 4.1.5 TEST RESULTS 28 5 . BANDWIDTH TEST 30 5.1 APPLIED PROCEDURES / LIMIT 30 5.1.1 TEST PROCEDURE 30 5.1.2 DEVIATION FROM STANDARD 30 Report No.:MTI141204004RF Page 4 of 39 Table of Contents Page 5.1.3 TEST SETUP 30 5.1.4 EUT OPERATION CONDITIONS 30 5.1.5 TEST RESULTS 31 6 . PEAK OUTPUT POWER TEST 33 6.1 APPLIED PROCEDURES / LIMIT 33 6.1.1 TEST PROCEDURE 33 6.1.2 DEVIATION FROM STANDARD 33 6.1.3 TEST SETUP 33 6.1.4 EUT OPERATION CONDITIONS 33 6.1.5 TEST RESULTS 34 7 . 100 KHZ BANDWIDTH OF FREQUENCY BAND EDGE 35 7.1 DEVIATION FROM STANDARD 35 7.2 TEST SETUP 35 7.3 EUT OPERATION CONDITIONS 35 7.4 TEST RESULTS 36 8 . ANTENNA REQUIREMENT 38 8.1 STANDARD REQUIREMENT 38 8.2 EUT ANTENNA 38 Report No.:MTI141204004RF Page 5 of 39 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15 (15.247) , Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission N/A 15.247 (a)(2) 6dB Bandwidth PASS 15.247 (b) Peak Output Power PASS 15.247 (c) Radiated Spurious Emission PASS 15.247 (d) Power Spectral Density PASS 15.205 Band Edge Emission PASS 15.203 Antenna Requirement PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Report No.:MTI141204004RF Page 6 of 39 1.1 TEST FACILITY Shenzhen Toby Technology Co., Ltd. Add.: 10/F.,A Block,Jiada R&D Bldg.,No.5 Songpingshan, Road, Science&Technology Park, Shenzhen, 518057 FCC Registration No.:811562 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 No. Item Uncertainty 1 Conducted Emission Test ±1.38dB 2 RF power,conducted ±0.16dB 3 Spurious emissions,conducted ±0.21dB 4 All emissions,radiated(<1G) ±4.68dB 5 All emissions,radiated(>1G) ±4.89dB 6 Temperature ±0.5°C 7 Humidity ±2% Report No.:MTI141204004RF Page 7 of 39 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF EUT Equipment Smart Switch Panel Trade Name USUNG Model Name US-SP101 Serial Model N/A Model Difference N/A Product Description The EUT is a Smart Switch Panel Operation Frequency: 2405~2480 MHz,(Channel Number:16, Channel Frequency=2405+5(K-1), K=1,2,3...16) Modulation Type: O-QPSK Number Of Channel 16CH Antenna Designation: Please see Note 3. Output Power(Conducted): 9.45 dBm (Max.) Antenna Gain (dBi) 2.0dbi Based on the application, features, or specification exhibited in User's Manual, the EUT is considered as an ITE/Computing Device. More details of EUT technical specification, please refer to the User's Manual. Channel List Please refer to the Note 2. Adapter N/A Battery DC 3.0V Connecting I/O Port(s) Please refer to the User's Manual Note: 1. For a more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. Report No.:MTI141204004RF Page 8 of 39 2. Channel List for 802.15.4 Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) 01 2405 05 2425 09 2445 13 2465 02 2410 06 2430 10 2450 14 2470 03 2415 07 2435 11 2455 15 2475 04 2420 08 2440 12 2460 16 2480 3. Table for Filed Antenna Ant . B…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No.:MTI141204004RF Page 39 of 39 9. EUT TEST PHOTO Radiated Measurement Photos

Contact Information

Applicant

Minghui Wang(Manager)
[email protected]0592-3929702Fax: 0592-3929702

Test Firm

Shenzhen Toby Technology Co., Ltd.Justin Zhang
[email protected]0086-755-26509301Fax: 0086-755-26509195

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz8.80 mW
Confidentiality
Long Term
Grant Notes
Output power is conducted.

Other Applications from Xiamen Tongren IOT Technology Co.,Ltd.

Smart Gateway - FCC ID 2AEEDUS-G101 - Xiamen Tongren IOT Technology Co.,Ltd.
2AEEDUS-G101

Smart Gateway

May 11, 2015

Equipment Class

DTS - Digital Transmission System
2AEEDUS-SC201

Smart Surveillance Camera

May 11, 2015

Equipment Class

DTS - Digital Transmission System
Smart Power Controller - FCC ID 2AEEDUS-PC201 - Xiamen Tongren IOT Technology Co.,Ltd.
2AEEDUS-PC201

Smart Power Controller

Apr 19, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
2AEEDUS-IC101

Smart IR Controller

Apr 19, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter