Date (07/04/2023) To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Ref: Attestation Statements Part 2.911(d)(5)(i) and Part 2.911(d)(5)(ii) Filing Re. KDB 986446 D01 FCC ID: 2AEWY-NL69 Dear Sir or Madam, NANOGRID LIMITED certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that NANOGRID LIMITED certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment . If you have any questions, please contact us. Yours sincerely, Company Officer: Christian Yan Telephone Number: +852 94979800 Email: [email protected]
To:Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date (07/04/2023) Ref:Attestation Statements Part 2.911(d)(7)Filing FCC ID:2AEWY-NL69 NANOGRID LIMITEDcertifies that, as of the date of the filing of the application,Americas Compliance Consulting, LLC dba iCertifiisour designated U.S. agent for service of process for the above referenced FCC ID.NANOGRID LIMITEDaccepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Americas Compliance Consulting, LLC dba iCertifiaccepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: FRN: 0033399411 Name: Americas Compliance Consulting, LLC dba iCertifi Address: 1001 SW Disk Drive, Suite 250 Bend, Oregon 97702 USA Contact Person: Paul Preston Tel.: (866) 885-4575 Email: [email protected] Sincerely, U.S. agent company name: Americas Compliance Consulting, LLC dba iCertifi U.S. agent company name printed name: Paul Preston U.S. agent company name signature: [Insert applicant name] NANOGRID LIMITED (Applicantprinted name) ChristianYan (Applicantsignature)
Date (07/04/2023) TUV SUD BABT UNLIMITED TCB Octagon House, Segensworth North, Fareham, Hampshire, PO15 5RL, United Kingdom Confidentiality Request FCC ID: 2AEWY-NL69 Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, (NANOGRID LIMITED) hereby requests permanent confidential treatment of information accompanying this application as outlined below: [Common exhibits for which confidentiality is requested are: Schematics Bill of Materials/Parts List Block Diagrams Theory of Operation] (NANOGRID LIMITED) also hereby requests short-term confidential treatment of information accompanying this application as outlined below for a period of until to December 31, 2023: [Common exhibits for which short-term confidentiality is requested are: Internal Photos External Photos User Manual Test Set-up Photographs The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Yours sincerely, Company Officer: Christian Yan Telephone Number: +852 94979800 Email: [email protected]
Date: 2023-07-04 TUV SUD BABT UNLIMITED TCB Octagon House, Segensworth North, Fareham, Hampshire, PO15 5RL, United Kingdom We, NANOGRID LIMITED (Address: Room 1301, 13/F, Excel Centre, 483A Castle Peak Road, Lai Chi Kok, Kowloon, HONG KONG) Hereby declare: Product name: Nanoleaf 4D light strip FCC ID: 2AEWY-NL69 Model list for LED luminaires: Model No. Rated Voltage (VAC) Rated Power (W) LED driver LED Qty. (pcs) Length (m) NL69K111X; NL69E111X 100-240 9 VS024- 1200200HU 30 1 NL69K112X; NL69E112X 18 60 2 NL69K113X; NL69E113X 24 90 3 NL69K114X; NL69E114X 24 120 4 NL69K115X; NL69E115X 24 156 5,2 Remark: [‘X’ can be 0-9, stands for internal production code] All models are electrically identical with same Schematics, PCB Layout and RF parameter. Only difference in LED Qty and model name for marketing purpose. Yours sincerely, Company Officer: Christian Yan Telephone Number: +852 94979800 Email: [email protected]
Date: 2023-07-04 Subject: Statement of disabled Protocol by software FCC ID: 2AEWY-NL69 To Whom It May Concern: We NANOGRID LIMITED hereby declare that • Matter • Zigbee • Bluetooth mesh • Proprietary 2.4 GHz • Multiprotocol are disabled by software in the factory, this setting is not accessible and can’t active by the user or any other third-party. Yours sincerely, Company Officer: Christian Yan Telephone Number: +852 94979800 Email: [email protected]
Date: 2023-07-04 To: Federal Communications Commission 7435 Oakland Mills Road Columbia MD FCC ID: 2AEWY-NL69 To Whom It May Concern: This letter is to ascertain that NANOGRID LIMITED Product name: Nanoleaf 4D light strip , Model: NL69K111X; NL69E111X; NL69K112X; NL69E112X; NL69K113X; NL69E113X; NL69K114X; NL69E114X; NL69K115X; NL69E115X [‘X’ can be 0-9, stands for internal production code] has been the units used for conducting FCC compliance testing, the SDoC part will be tested by FCC recognized test lab. If you have any question or concerns, please contact us. Yours sincerely, Company Officer: Christian Yan Telephone Number: +852 94979800 Email: [email protected]
Details of: Controller view Remark: Details of: Controller view Remark: Details of: Accessory’s view Remark: Representative model: NL69K1150 Details of: Accessory’s view for LED Strip light Remark: Details of: Accessory’s view for LED Strip light Remark: Details of: LED driver view (VS024-1200200HU) Remark:
Nanoleaf 4D Model: NL69K1150 Input: 12V 1.7A Power: 24W FCC ID: 2AEWY-NL69 IC: 20489-NL69 Date Code: 1807 Unique ID: 2184 00:55:DA:50:21:84 CONFORMS TO UL STD 153 CERTIFIED TO CSA STD C22.2 NO 250.4 SUITABLE FOR DAMP LOCATIONS CONVIENT AUX EMPLACEMENTS HUMIDES For use with Class 2, 12V, max. 2.0A power supply À utiliser avec une alimentation de Classe 2, 12V, max. 2,0A Made In China NF082K03-52LS 5026245 1058 9705 1058 9705 30mm 20mm
Details of: Controller internal view Remark: Details of: Controller PCB view Remark: BLE and Thread Antenna BLE and Thread Module Details of: Controller PCB view Remark: Details of: Controller PCB view Remark: Details of: WIFI RF module view Remark: Details of: WIFI RF module view Remark: WIFI Antenna Location Details of: LED driver view (VS024-1200200HU) Remark: Details of: LED driver view (VS024-1200200HU) Remark:
Report Number: 68.940.23.0026.01A EMC_SZ_FR_23.03 MPE Release 2022-05-06 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 9 FCC Maximum Permissible Exposure (MPE) Report Report Number : 68.940.23.0026.01A Date of Issue: July 4, 2023 Model : NL69K111X; NL69E111X; NL69K112X; NL69E112X; NL69K113X; NL69E113X; NL69K114X; NL69E114X; NL69K115X; NL69E115X [‘X’ can be 0-9, stands for internal production code] Product Type : Nanoleaf 4D light strip Applicant : NANOGRID LIMITED Address : Room 1301, 13/F, Excel Centre, 483A Castle Peak Road, Lai Chi Kok, Kowloon, HONG KONG Production Facility : SEVECO GLOBAL LTD. Address : 2 Jianxiang St. Hanxishui Chashan Town, 523377 Dongguan, Guangdong, PEOPLE'S REPUBLIC OF CHINA Test Result : ◼ Positive Negative Total pages including Appendices : 9 Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing and certification regulation, chapter A-3.4. Report Number: 68.940.23.0026.01A EMC_SZ_FR_23.03 MPE Release 2022-05-06 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 9 1 Table of Contents 1 Table of Contents .................................................................................................................. 2 2 Details about the Test Laboratory .......................................................................................... 3 3 Description of the Equipment Under Test .............................................................................. 4 4 Test Specifications ................................................................................................................. 5 5 General Information ............................................................................................................... 6 6 RF Exposure Requirements ................................................................................................... 7 7 FCC MPE Limits .................................................................................................................... 8 8 RF Exposure Evaluation (FCC) ............................................................................................. 9 8.1 Calculation of Power Density for Single Transmission.................................................... 9 8.2 Calculation of Simultaneous Transmission ..................................................................... 9 8.3 Conclusion ...................................................................................................................... 9 Report Number: 68.940.23.0026.01A EMC_SZ_FR_23.03 MPE Release 2022-05-06 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 9 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, 518052 China FCC Designation Number: CN5009 Telephone: 86 755 8828 6998 Fax: 86 755 8828 5299 Report Number: 68.940.23.0026.01A EMC_SZ_FR_23.03 MPE Release 2022-05-06 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 4 of 9 3 Description of the Equipment Under Test Product: Nanoleaf 4D light strip Model no.: NL69K1150 FCC ID: 2AEWY-NL69 Options and accessories: NIL Ratings: 12VDC, 2A (Powered by Adapter) Adapter: Model: VS024-1200200HU Input: 100-240VAC; 50/60Hz; 0.6A Output: 12.0VDC; 2.0A RF Transmission Frequency: 2412-2462MHz for Wi-Fi 2402-2480MHz for BLE 2405-2480MHz for Thread No. of Operated Channel: 11 for Wi-Fi 40 for BLE 16 for Thread Modulation: Wi-Fi: CCK, DQPSK, DBPSK for 802.11b QPSK,BPSK for 802.11g/n BLE: GFSK Thread: QPSK Antenna Type: PCB Antenna Antenna Gain: 2.15dBi for BLE and Thread 3.46dBi for Wi-Fi Description of the EUT: The Equipment Under Test (EUT) is a Nanoleaf 4D light strip supports BLE, Thread and Wi-Fi functions. NOTE 1: The above EUT’s information is declared by manufacturer. Please refer to the specifications or user’s manual for more detailed description. Report Number: 68.940.23.0026.01A EMC_SZ_FR_23.03 MPE Release 2022-05-06 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 5 of 9 4 Test Specifications Test Standards ANSI Std C95.1-1992 Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz – 300 GHz.(IEEE Std C95.1-1991) KDB 447498 D01 General RF Exposure Guidance v06 Report Number: 68.940.23.0026.01A EMC_SZ_FR_23.03 MPE Release 2022-05-06 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 6 of 9 5 General Information Any use for advertising purposes must be granted in writing. This technical …
Text truncated - open the document above for the full version.
Report Number: 68.940.23.0026.01 EMC_SZ_FR_23.02 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 61 FCC - TEST REPORT Report Number : 68.940.23.0026.01 Date of Issue: July 5, 2023 Model : NL69K111X; NL69E111X; NL69K112X; NL69E112X; NL69K113X; NL69E113X; NL69K114X; NL69E114X; NL69K115X; NL69E115X [‘X’ can be 0-9, stands for internal production code] Product Type : Nanoleaf 4D light strip Applicant : NANOGRID LIMITED Address : Room 1301, 13/F, Excel Centre, 483A Castle Peak Road, Lai Chi Kok, Kowloon, HONG KONG Production Facility : SEVECO GLOBAL LTD. Address : 2 Jianxiang St. Hanxishui Chashan Town, 523377 Dongguan, Guangdong, PEOPLE'S REPUBLIC OF CHINA Test Result : ◼ Positive Negative Total pages including Appendices : 61 Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing and certification regulation, chapter A-3.4. Report Number: 68.940.23.0026.01 EMC_SZ_FR_23.02 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 61 1 Table of Contents 1 Table of Contents ................................................................................................................................................................. 2 2 Details about the Test Laboratory ..................................................................................................................................... 3 3 Description of the Equipment under Test ......................................................................................................................... 4 4 Summary of Test Standards ............................................................................................................................................... 5 5 Summary of Test Results ................................................................................................................................................... 6 6 General Remarks ................................................................................................................................................................. 7 7 Test Setups ........................................................................................................................................................................... 8 8 Systems test configuration ............................................................................................................................................... 10 9 Technical Requirement ......................................................................................................................................................... 11 9.1 Conducted Emission ................................................................................................................................................ 11 9.2 Conducted peak output power................................................................................................................................ 14 9.3 6dB bandwidth .......................................................................................................................................................... 16 9.4 Power spectral density ............................................................................................................................................. 23 9.5 Spurious RF conducted emissions ........................................................................................................................ 30 9.6 Band edge ................................................................................................................................................................. 50 9.7 Spurious radiated emissions for transmitter ......................................................................................................... 55 10 Test Equipment List ...................................................................................................................................................... 60 11 System Measurement Uncertainty ............................................................................................................................. 61 Report Number: 68.940.23.0026.01 EMC_SZ_FR_23.02 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 61 2 Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China FCC Registration Number: 514049 FCC Designation Number: CN5009 ISED#: 10320A CAB identifier: CN0077 Telephone: 86 755 8828 6998 Fax: 86 755 8828 5299 Report Number: 68.940.23.0026.01 EMC_SZ_FR_23.02 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 4 of 61 3 Description of the Equipment under Test Product: Nanoleaf 4D light strip Model no.: NL69K1150 FCC ID: 2AEWY-NL69 Options and acces…
Text truncated - open the document above for the full version.
Shenzhen RF sister Communication co., Ltd. 10th floor, Lingyun Building, Honglang North 2nd Road, District 67, Baoan District, Shenzhen, China Product Characteristics Model: A3 Manufacturer: Shenzhen RF sister Communication co., Ltd. 10th floor, Lingyun Building, Honglang North 2nd Road, District 67, Baoan District, Shenzhen, China Transmitter Frequency: 2400MHz~2483.5MHz Receiver Frequency: 2400MHz~2483.5MHz Antenna information: Antenna Name Model(s)/Type(s) RF Antenna Assembly Model/Part Number: A3 Manufacturer: Shenzhen RF sister Communication co., Ltd. Frequency Range: 2400MHz~2483.5MHz Connector Type/ Maximum Gain Integrated, 2.15 dBi Antenna Type/ Pattern: PCB Antenna Measurement: 17.582mm(L)*3mm(W)*0.8mm(T) Fig.1: The dimension of the PCB Antenna Fig.2: The pattern of the PCB Antenna
Shenzhen RF sister Communication co., Ltd. 10th floor, Lingyun Building, Honglang North 2nd Road, District 67, Baoan District, Shenzhen, China Product Characteristics Model: A4 Manufacturer: Shenzhen RF sister Communication co., Ltd. 10th floor, Lingyun Building, Honglang North 2nd Road, District 67, Baoan District, Shenzhen, China Transmitter Frequency: 2400MHz~2483.5MHz Receiver Frequency: 2400MHz~2483.5MHz Antenna information: Antenna Name Model(s)/Type(s) RF Antenna Assembly Model/Part Number: A4 Manufacturer: Shenzhen RF sister Communication co., Ltd. Frequency Range: 2400MHz~2483.5MHz Connector Type/ Maximum Gain Integrated, 3.46 dBi Antenna Type/ Pattern: PCB Antenna Measurement: 26.35mm(L)*6.17mm(W)*1.0mm(T) Fig.1: The dimension of the PCB Antenna Fig.2: The pattern of the PCB Antenna Shenzhen RF sister Communication co., Ltd. 10th floor, Lingyun Building, Honglang North 2nd Road, District 67, Baoan District, Shenzhen, China
Report Number: 68.940.23.0015.01 EMC_SZ_FR_23.02 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 35 FCC - TEST REPORT Report Number : 68.940.23.0015.01 Date of Issue: July 5, 2023 Model : NL69K111X; NL69E111X; NL69K112X; NL69E112X; NL69K113X; NL69E113X; NL69K114X; NL69E114X; NL69K115X; NL69E115X [‘X’ can be 0-9, stands for internal production code] Product Type : Nanoleaf 4D light strip Applicant : NANOGRID LIMITED Address : Room 1301, 13/F, Excel Centre, 483A Castle Peak Road, Lai Chi Kok, Kowloon, HONG KONG Production Facility : SEVECO GLOBAL LTD. Address : 2 Jianxiang St. Hanxishui Chashan Town, 523377 Dongguan, Guangdong, PEOPLE'S REPUBLIC OF CHINA Test Result : ◼ Positive Negative Total pages including Appendices : 35 Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing and certification regulation, chapter A-3.4. Report Number: 68.940.23.0015.01 EMC_SZ_FR_23.02 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 35 1 Table of Contents 1 Table of Contents ................................................................................................................................................................ 2 2 Details about the Test Laboratory ..................................................................................................................................... 3 3 Description of the Equipment under Test ........................................................................................................................ 4 4 Summary of Test Standards .............................................................................................................................................. 5 5 Summary of Test Results ................................................................................................................................................... 6 6 General Remarks ................................................................................................................................................................ 7 7 Test Setups .......................................................................................................................................................................... 8 8 Systems test configuration ............................................................................................................................................... 10 9 Technical Requirement .................................................................................................................................................... 11 9.1 Conducted Emission ................................................................................................................................................ 11 9.2 Conducted peak output power................................................................................................................................ 14 9.3 6dB bandwidth .......................................................................................................................................................... 17 9.4 Power spectral density ............................................................................................................................................. 20 9.5 Spurious RF conducted emissions ........................................................................................................................ 23 9.6 Band edge ................................................................................................................................................................. 29 9.7 Spurious radiated emissions for transmitter ......................................................................................................... 31 10 Test Equipment List ...................................................................................................................................................... 34 11 System Measurement Uncertainty ............................................................................................................................. 35 Report Number: 68.940.23.0015.01 EMC_SZ_FR_23.02 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 35 2 Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China FCC Registration Number: 514049 FCC Designation Number: CN5009 ISED#: 10320A CAB identifier: CN0077 Telephone: 86 755 8828 6998 Fax: 86 755 8828 5299 Report Number: 68.940.23.0015.01 EMC_SZ_FR_23.02 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 4 of 35 3 Description of the Equipment under Test Product: Nanoleaf 4D light strip Model no.: NL69K1150 FCC ID: 2AEWY-NL69 Ratings: 12VDC, 2A (Powered…
Text truncated - open the document above for the full version.
Report Number: 68.940.21.0067.01 EMC_SZ_FR_23.02 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 35 FCC - TEST REPORT Report Number : 68.940.21.0067.01 Date of Issue: July 5, 2023 Model : NL69K111X; NL69E111X; NL69K112X; NL69E112X; NL69K113X; NL69E113X; NL69K114X; NL69E114X; NL69K115X; NL69E115X [‘X’ can be 0-9, stands for internal production code] Product Type : Nanoleaf 4D light strip Applicant : NANOGRID LIMITED Address : Room 1301, 13/F, Excel Centre, 483A Castle Peak Road, Lai Chi Kok, Kowloon, HONG KONG Production Facility : SEVECO GLOBAL LTD. Address : 2 Jianxiang St. Hanxishui Chashan Town, 523377 Dongguan, Guangdong, PEOPLE'S REPUBLIC OF CHINA Test Result : ◼ Positive Negative Total pages including Appendices : 35 Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing and certification regulation, chapter A-3.4. Report Number: 68.940.21.0067.01 EMC_SZ_FR_23.02 FCC Release 2017-06-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 35 1 Table of Contents 1 Table of Contents ................................................................................................................................................................ 2 2 Details about the Test Laboratory ..................................................................................................................................... 3 3 Description of the Equipment under Test ........................................................................................................................ 4 4 Summary of Test Standards .............................................................................................................................................. 5 5 Summary of Test Results ................................................................................................................................................... 6 6 General Remarks ................................................................................................................................................................ 7 7 Test Setups .......................................................................................................................................................................... 8 8 Systems test configuration ............................................................................................................................................... 10 9 Technical Requirement .................................................................................................................................................... 11 9.1 Conducted Emission ........................................................................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 3 | 15C | 2.40 GHz - 2.48 GHz | 4.30 mW |

Nanoleaf Sense+ Smart Button
Equipment Class
DTS - Digital Transmission System
Nanoleaf WIFI module
Equipment Class
DTS - Digital Transmission System
Nanoleaf BLE&Thread-Matter module
Equipment Class
DTS - Digital Transmission System
Nanoleaf Esseantials Module
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Nanoleaf Essentials Light Strips
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter