FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Rollease Acmeda Inc/
  3. 2AGGZ003B9ACA49

2AGGZ003B9ACA49VT Tilt Motor

Rollease Acmeda Inc
VT Tilt Motor - FCC ID 2AGGZ003B9ACA49 - Rollease Acmeda Inc
Click to zoom

Application Details

Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Date of Grant
Jul 27, 2023
Application Purpose
Original Equipment
Date of Application
Jul 27, 2023
Equipment Note
VT Tilt Motor
Frequency Range
433.92000000 - 433.92000000
Company
Rollease Acmeda Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

AUTOMATE ™ CORE AND TILT MOTOR INSTRUCTIONS SOLAR OPTION FAVORITE POSITION SELECTABLE SPEED ELECTRONIC LIMIT LEVEL CONTROL 433 MHZ BI-DIRECTIONAL PART NUMBERDESCRIPTION MT01-4001-xxx002Passthrough Tilt Motor Kit MT01-4001-069003AUTOMATE | VT TILT [12V/0.6Nm/11rpm] • USE THIS DOCUMENT WITH THE FOLLOWING MOTORS: AUTOMATE_TILT_PRGM_OCT_2023 2 | Automate ™ Programming Instructions | Tilt Motors ROLLEASE ACMEDA SAFETY INSTRUCTIONS WARNING: Important safety instructions to be read before installation. Incorrect installation can lead to serious injury and will void manufacturer’s liability and warranty. CAUTION • Do not expose to moisture or extreme temperatures. • Do not allow children to play with this device. • Use or modification outside the scope of this instruction manual will void warranty. • Installation and programming to be performed by a suitably qualified installer. • For use within tubular blinds. • Ensure correct crown and drive adaptors are used for the intended system. • Keep antenna straight and clear from metal objects • Do not cut the antenna. • Use only Rollease Acmeda hardware. • Before installation, remove any unnecessary cords and disable any equipment not needed for powered operation. • Ensure torque and operating time is compatible with end application. • Do not expose the motor to water or install in humid or damp environments. • Motor is to be installed in horizontal application only. • Do not drill into motor body. • The routing of cable through walls shall be protected by isolating bushes or grommets. • Ensure power cable and aerial is clear and protected from moving parts. • If cable or power connector is damaged do not use. Important safety instructions to be read prior to operation. • It is important for the safety of persons to follow the enclosed instructions. Save these instructions for future reference. • Persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge should not be allowed to use this product. • Keep remote controls away from children. • Frequently inspect for improper operation. Do not use if repair or adjustment is necessary. • Keep motor away from acid and alkali. • Do not force the motor drive. • Keep clear when in operation. Do not dispose of in general waste. Please recycle batteries and damaged electrical products appropriately. ROLLEASE ACMEDA Automate ™ Programming Instructions | Tilt Motor s | 3 U.S. Radio Frequency FCC Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interfer ence, and (2) This device must accept any interfer ence received, including interfer ence that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable prot ection against harmful interfer ence in a residential installation. This equipment generat es, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interfer ence to radio communications. However, there is no guarantee that interfer ence will not occur in a particular installation. If this equipment does cause harmful interfer ence to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interfer ence by one or more of the following measures: • Reorient or rel ocat e the receiving antenna. • Increase the separation between the equipment and receiver . • Connect the equipment into an outlet on a circuit differ ent from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician to help. Any Changes or modifications not expressl y approved by the party responsibl e for compliance could void the user’s authority to operate the equipment. ISED RSS Warning: This device complies with Innovation, Science and Economic Development Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interfer ence, and (2) this device must accept any interfer ence, including interfer ence that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d’ISED applicables aux appareils radio exemps de licence. L’e xploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, méme si le brouillage est susceptible d’en compromettre le fonctionnement. To satisfy FCC / IC RF exposure requirements, a separation distance of 20 cm or more should be maintained between the antenna of this device and persons during device operation. To ensure compliance, operations at closer than this distance is not recommended. Les antennes installées doivent être situées de facon à ce que la population ne puisse y être exposée à une distance de moin de 20 cm. Installer les antennes de facon à ce que le personnel ne puisse approcher à 20 cm ou moins de la position centrale de l’ antenne. La FCC des éltats-unis stipule que cet appareil doit être en tout temps éloigné d’au moins 20 cm des personnes pendant son functionnement. 4 | Automate ™ Programming Instructions | Tilt Motors ROLLEASE ACMEDA CONTENTS 1 CORE TILT MOTOR ASSEMBLY 5 2 CORE TILT MOTOR WAND OPERATION 6 3 TILT MOTOR ASSEMBLY 7 4 WIRING 8 4.1 Power Options 8 5 P1 BUTTON FUNCTIONS 9 5.1 Motor state test 9 5.2 Motor configuration options 9 6 INITIAL SET UP 10 6.1 Pair motor with controller 10 6.2 Check motor direction 10 6.3 Set Limits 11 7 ADJUSTING LIMITS 12 7.1 Adjust upper limit 12 7.2 Adjust lower limit 12 8 CONTROLLERS AND CHANNELS 13 8.1 Using P2 Button on existing controller to add a new controller or channel 13 8.2 Using a pre-existing controller to add or d…

Text truncated - open the document above for the full version.

Attestation Statements

Rev 1/26/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 06-01-2023 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2AGGZ003B9ACA49 Rollease Acmeda Inc certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Applicant signature: Applicant printed name: Jonny.Matuichuk

Attestation Statements

To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 06-01-2023 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: 2AGGZ003B9ACA49 Rollease Acmeda Inc. certifies that, as of the date of the filing of the application, we designate ourselves as the U. S. agent for service of process. Designated U.S. Agent Information: FRN: 0025043381 Name: Rollease Acmeda Inc Address: 7th Floor / 750 East Main Street,Stamford, CT 06902, USA Contact Person: Jonny.Matuichuk Tel.: 2034906191 Email: [email protected] Sincerely, Jonny.Matuichuk

Attestation Statements

Rev 1/26/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 06-01-2023 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2AGGZ003B9ACA49 Rollease Acmeda Inc certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Applicant signature: Applicant printed name: Jonny.Matuichuk

Cover Letter(s)

Date: 01/06/2023 Confidentiality Request FCC ID: 2AGGZ003B9ACA49 Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, Rollease Acmeda Inc ( 7th Floor / 750 East Main Street, Stamford, CT 06902, USA) hereby requests permanent confidential treatment of information accompanying this application as outlined below: Schematics, Block Diagrams, Operation Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Yours sincerely, Company Officer: Jonny.Matuichuk Telephone Number: Email: [email protected]

Cover Letter(s)

Date: 06-01-2023 Dear Sir or Madam, We, Rollease Acmeda Inc (7th Floor / 750 East Main Street, Stamford, CT 06902, USA), hereby authorize Yu Anlu from TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151 Heng Tong Road Shanghai 201108 P.R. China to act as our agent in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. This authorization expires on 12-01-2023. Sincerely, Company Officer: Jonny.Matuichuk Telephone Number: Email: [email protected] SUBJECT: FCC Application for FCC ID: 2AGGZ003B9ACA49

Cover Letter(s)

RolleaseAcmeda Inc Date:2023-05-29 To: Federal Communications Commission 7435 Oakland Mills Road Columbia MD FCC ID:2AGGZ003B9ACA49 To Whom It May Concern: This letter is to ascertain that RolleaseAcmeda Inc Product name: VT Tilt Motor, Model: MT01-4001-069003 has been the units used for conducting FCC compliance testing, the SDoC part will be tested by FCC recognized test lab. If you have any question or concerns, please contact us. Sincerely, Signature Company name:RolleaseAcmeda Inc Address:7th Floor / 750 East Main Street,Stamford, CT 06902, USA E- mail:[email protected] Tel:2034906191 Printed Name:Jonny.Matuichuk

External Photos

External Photos Documentation Manufacturer: Rollease Acmeda Inc Page 1 of 3 Product: VT Tilt Motor FCC ID: 2AGGZ003B9ACA49 IC: 21769-003B9ACA49 Antenna for SRD External Photos Documentation Manufacturer: Rollease Acmeda Inc Page 2 of 3 Product: VT Tilt Motor FCC ID: 2AGGZ003B9ACA49 IC: 21769-003B9ACA49 External Photos Documentation Manufacturer: Rollease Acmeda Inc Page 3 of 3 Product: VT Tilt Motor FCC ID: 2AGGZ003B9ACA49 IC: 21769-003B9ACA49

Internal Photos

Internal Photos Documentation Manufacturer: Rollease Acmeda Inc Page 1 of 4 Product: VT Tilt Motor FCC ID: 2AGGZ003B9ACA49 IC: 21769-003B9ACA49 Internal Photos Documentation Manufacturer: Rollease Acmeda Inc Page 2 of 4 Product: VT Tilt Motor FCC ID: 2AGGZ003B9ACA49 IC: 21769-003B9ACA49 Internal Photos Documentation Manufacturer: Rollease Acmeda Inc Page 3 of 4 Product: VT Tilt Motor FCC ID: 2AGGZ003B9ACA49 IC: 21769-003B9ACA49 Internal Photos Documentation Manufacturer: Rollease Acmeda Inc Page 4 of 4 Product: VT Tilt Motor FCC ID: 2AGGZ003B9ACA49 IC: 21769-003B9ACA49

RF Exposure Info

Report No: 709502302446-00B EMC_SHA_F_R_02.06E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 1 of 2 Rev. 20.00 MPE Calculation Applicant: Rollease Acmeda Inc Address: 7th Floor / 750 East Main Street, Stamford, CT 06902, USA Product: VT Tilt Motor FCC ID: 2AGGZ003B9ACA49 Model No.: MT01-4001-069003 Reference RF report # 709502302446-00A According to subpart 15.247(i)and subpart §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091) (B) Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (minutes) 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f²) 30 30–300 27.5 0.073 0.2 30 300–1,500 / / f/1500 30 1,500–100,000 / / 1.0 30 f = frequency in MHz; * = Plane-wave equivalent power density; According to §1.1310 and §2.1091 RF exposure is calculated. Calculated Formulary: Predication of MPE limit at a given distance S = PG/4πR² = power density (in appropriate units, e.g. mW/cm 2 ); P = power input to the antenna (in appropriate units, e.g., mW); G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain factor, is normally numeric gain; R = distance to the center of radiation of the antenna (appropriate units, e.g., cm); Report No: 709502302446-00B EMC_SHA_F_R_02.06E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 2 of 2 Rev. 20.00 Calculation method for 433.92MHz Per the test report included herein, for 433.92MHz According to C63.10 Annex G EIRP = pt × gt =(E × d) 2 /30 where pt is the transmitter output power in watts gt is the numeric gain of the transmitting antenna (dimensionless) E is the electric field strength in V/m d is the measurement distance in meters (m) transmitter output power for 433.92MHz Function Field strength (E): 91.829 (dBuV/m) = 0.0390 (V/m) Measurement Distance(dMeas): 3 (m) Equivalent Isotropically Radiated Power(EIRP): 0.0004563W=0.4563mW According to §1.1310 and §2.1091 RF exposure is calculated. Calculated Formulary: Predication of MPE limit at a given distance S = PG/4πR² = power density (in appropriate units, e.g. mW/cm 2 ); PG = 0.4563mW (in appropriate units, e.g., mW); R = distance to the center of radiation of the antenna (appropriate units, e.g., cm); Calculated Data: The max power density 0.4563/4πR²= 9.07780*10 -5 (mW/cm 2 ) < 0.28928 (mW/cm 2 ) Result: Compliant - TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch Reviewed by: Prepared by: Tested by: _____________________ _____________________ ______________________ Hui TONG Wenqiang LU Yiquan WANG EMC Section Manager EMC Project Engineer EMC Test Engineer Date: 2023-07-04 Date: 2023-07-04 Date: 2023-07-04

Test Report

Report Number: 709502302446-00A EMC_SHA_F_R_02.05E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 1 of 20 Rev. 171.00 FCC/IC- TEST REPORT Report Number : 709502302446-00A Date of Issue: July 04, 2023 Model : MT01-4001-069003 Product Type : VT Tilt Motor Applicant : Rollease Acmeda Inc Address : 7th Floor / 750 East Main Street, Stamford, CT 06902, USA Production Facility : Ningbo Dooya Mechanic & Electronic Technology Co., Ltd. Address : No.168 Shengguang Road, Luotuo, Zhenhai 315202 Ningbo, : Zhejiang province People's Republic of China Test Result : ◼ Positive  Negative Total pages including Appendices : 20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined in ISO 17025. TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch reports apply only to the specific samples tested under stated test conditions. Construction of the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch shall have no liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval. dc Report Number: 709502302446-00A EMC_SHA_F_R_02.05E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 2 of 20 Rev. 171.00 1 Table of Contents 1 Table of Contents .................................................................................................................. 2 2 Details about the Test Laboratory ......................................................................................... 3 3 Description of the Equipment Under Test .............................................................................. 4 4 Summary of Test Standards .................................................................................................. 5 5 Summary of Test Results ...................................................................................................... 6 6 General Remarks .................................................................................................................. 7 7 Systems test configuration .................................................................................................... 8 8 Test Setups ........................................................................................................................... 9 9 Test Methodology ................................................................................................................ 10 9.1 Radiated Emission ........................................................................................................ 10 9.2 Bandwidth Measurement & 99% Occupied Bandwidth ................................................. 14 9.3 Deactivation Time ......................................................................................................... 16 10 Test Equipment List ............................................................................................................ 17 11 System Measurement Uncertainty ...................................................................................... 18 12 Photographs of Test Set-ups ........................................................................................... 19 13 Photographs of EUT ........................................................................................................ 20 Report Number: 709502302446-00A EMC_SHA_F_R_02.05E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 3 of 20 Rev. 171.00 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch No.16 Lane, 1951 Du Hui Road, Shanghai 201108, P.R. China FCC Registration Number: 820234 Designation Number: CN1183 IC Company Number: 25988 CAB identifier: CN0101 Telephone: +86 21 6141 0123 Fax: +86 21 6140 8600 Report Number: 709502302446-00A EMC_SHA_F_R_02.05E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 4 of 20 Rev. 171.00 3 Description of the Equipment Under Test Product: VT Tilt Motor Model no./HVIN: MT01-4001-069003 FCC ID: 2AGGZ003B9ACA49 IC: 21769-003B9ACA49 Rating: DC 12V RF Transmission Frequency: 433.92 MHz No. of Operated Channel: 1 Modulation: FSK Antenna Type: Line Antenna Antenna Gain: -1 dBi for 433.92MHz SRD Description of the EUT: The Equipment Under Test (EUT) is a VT Tilt Motor withSRD function. We tested it and listed the worst data in this report. Test sample no.: SHA-723326-2 The sample’s mentioned in this report is/are submitted/ supplied/ manufactured by client. The laboratory therefore assumes no responsibility for accuracy of information on the brand name, model number, origin of manufacture, consignment, antenna gain or any information supplied. Report Number: 709502302446-00A EMC_SHA_F_R_02.05E TÜV SÜD C…

Text truncated - open the document above for the full version.

Test Report

 Antenna Information To whom it may concern, Product name:VT Tilt Motor Model:MT01-4001-069003 FCC ID: 2AGGZ003B9ACA49 IC: 21769-003B9ACA49 The applicable FCC rule part of this product is § 15.231,radiated measurements are used to show compliance with FCC limits for fundamental and spurious emissions. The Antenna information as below for your reference. Antenna photo: Antenna transmission frequency: 433.92MHz Antenna type: Line antenna Antenna Gain: -1dBi Yours sincerely, Name:JonnyMatuichuk Companyname: RolleaseAcmeda Inc Address: 750 East Main Street, 7th Floor, Stamford CT 06902, USA Title: Product Manager -Motorization E‐mail: [email protected] Tel:+1 2038326756

Test Setup Photos

Manufacturer: Rollease Acmeda Inc Product: VT Tilt Motor FCC ID: 2AGGZ003B9ACA49 IC: 21769-003B9ACA49 ©2023 Not to be reproduced, except in its entirety, Page 1 of 1 without the Permission of TÜ V SÜ D Certification and Testing (China) Co., Ltd. Shanghai Branch PHOTOGRAPHS OF TEST SET UP Field Strength and Harmonics Test Setup Radiated Emission Setup 30MHz ~ 1GHz 1GHz ~ 4.5GHz

Contact Information

Applicant

Jonny Emilio Matuichuk(Product Manager - Motorization)
[email protected]2034906191Fax: 2039641503

Test Firm

TUV SUD Certification and Testing (China) Co., LtdYi Ba
[email protected]86 21 6140 0132

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term
Grant Notes
Device must be operated to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Rollease Acmeda Inc

Transmitter(Push one channel remote) - FCC ID 2AGGZ003B9ACA50 - Rollease Acmeda Inc
2AGGZ003B9ACA50

Transmitter(Push one channel remote)

Jul 26, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Li-ion 0.5Nm ARC Motor - FCC ID 2AGGZ003B9ACA51 - Rollease Acmeda Inc
2AGGZ003B9ACA51

Li-ion 0.5Nm ARC Motor

Jul 22, 2023

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
DC 1.1Nm ARC Motor - FCC ID 2AGGZ003B9ACA4C - Rollease Acmeda Inc
2AGGZ003B9ACA4C

DC 1.1Nm ARC Motor

Jul 08, 2023

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
DC 2.0Nm ARC Motor - FCC ID 2AGGZ003B9ACA4D - Rollease Acmeda Inc
2AGGZ003B9ACA4D

DC 2.0Nm ARC Motor

Jul 08, 2023

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Li-ion 1.1Nm ARC Motor - FCC ID 2AGGZ003B9ACA4A - Rollease Acmeda Inc
2AGGZ003B9ACA4A

Li-ion 1.1Nm ARC Motor

Jul 06, 2023

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver