Li-ion & DC Motor MOTOR PROGRAMMING INSTRUCTIONS AUTOMATE V3.2_PRGM_APRIL_2022 SOFT STOP FAVORITE POSITION Fav Position BATTERY CHECK433 MHZ BI-DIRECTIONAL Live Feedback LEVEL CONTROL SOLAR OPTION SELECTABLE SPEED BATTERY POWERED USB CHARGE (Only for Li-ion Motor) ELECTRONIC LIMIT 2 | Automate ™ Programming Instructions | Li-ion & DC Motors ROLLEASE ACMEDA SAFETY INSTRUCTIONS COMPLIANCE STATEMENT WARNING: Important safety instructions to be read before installation. Incorrect installation can lead to serious injury and will void manufacturer’s liability and warranty. WARNING: Important safety instructions to be read before installation and use. Incorrect installation or use can lead to serious injury and will void manufacturer’s liability and warranty. It is important for the safety of persons to follow the enclosed instructions. Save these instructions for future reference. • Do not expose to water, moisture, humid and damp environments or extreme temperatures. • Persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge should not be allowed to use this product. • Use or modification outside the scope of this instruction manual will void warranty. • Installation and programming to be performed by a suitably qualified installer. • Follow installation instructions. • For use with motorized shading devices. • Keep away from children. • Frequently inspect for improper operation. Do not use if repair or adjustment is necessary. • Keep clear when in operation. • Replace battery with correctly specified type. This device complies with Part 15 of the FCC Rules / Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. To satisfy FCC / IC RF exposure requirements, a separation distance of 20 cm or more should be maintained between the antenna of this device and persons during device operation. To ensure compliance, operations at closer than this distance is not recommended. Les antennes installées doivent être situées de facon à ce que la population ne puisse y être exposée à une distance de moin de 20 cm. Installer les antennes de facon à ce que le personnel ne puisse approcher à 20 cm ou moins de la position centrale de l’ antenne. La FCC des éltats-unis stipule que cet appareil doit être en tout temps éloigné d’au moins 20 cm des personnes pendant son functionnement. Do not dispose of in general waste. Please recycle batteries and damaged electrical products appropriately. ROLLEASE ACMEDA Automate ™ Programming Instructions | Li-ion & DC Motors | 3 CONTENTS 1 ASSEMBLY 4 2 RETROFIT INSTALLATION 5 3 CHARGING 5 4 P1 BUTTON FUNCTIONS 6 4.1 Motor state test 6 4.2 Motor configuration options 6 5 INITIAL SET UP 7 5.1 Pair motor with controller 7 5.2 Check motor direction 7 5.3 Set Limits 8 6 ADJUSTING LIMITS 9 6.1 Adjust upper limit 9 6.2 Adjust lower limit 9 7 CONTROLLERS AND CHANNELS 10 7.1 Using P2 Button on existing controller to add a new controller or channel 10 7.2 Using a pre-existing controller to add or delete a controller or channel 10 8 FAVORITE POSITIONING 11 8.1 Set a favorite position 11 8.2 Send shade to favorite position 11 8.3 Delete favorite position 11 9 TILT & ROLLER MODE 12 9.1 Toggle motor to Tilt Mode 12 9.2 Toggle Motor to Roller Mode 12 10 ADJUSTING SPEED 13 10.1 Increase Motor Speed 13 10.2 Decrease Motor Speed 13 11 SOFT STOP CONFIGURATION 14 11.1 Turn Soft Stop OFF 14 11.2 Turn Soft Stop ON 14 12 BATTERY CHECK FUNCTION 15 12.1 Send Shade to battery charge level 15 13 CHARGING LED 15 13.1 Turn Charging LED ON/OFF 15 14 SLEEP MODE 16 15 TROUBLE SHOOTING 16 4 | Automate ™ Programming Instructions | Li-ion & DC Motors ROLLEASE ACMEDA 1 ASSEMBLY ZERO HEAD ADAPTER ZERO HEAD ANTENNA WRAP GENERIC CROWN, DRIVE & TUBE ASSEMBLY ROLLEASE ACMEDA Automate ™ Programming Instructions | Li-ion & DC Motors | 5 3 CHARGING/POWER SUPPLY 2 RETROFIT INSTALLATION (1.1Nm & 2.0Nm MOTOR ONLY) (LI-ION 1.1Nm & 2.0Nm ONLY)(LI-ION 3.0Nm & 10.0Nm ONLY)(DC 1.1Nm & 2.0Nm ONLY) Requries a continuous 12V DC Power Source. 6 | Automate ™ Programming Instructions | Li-ion & DC Motors ROLLEASE ACMEDA 4.1 Motor state test 4.2 Motor configuration options This table desc…
Text truncated - open the document above for the full version.
Rev 1/26/2023 Rollease Acmeda Inc Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 05- 29-2023 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2AGGZ003B9ACA4C Rollease Acmeda Inc.certifies that the equipment for which authorization is sought is not“covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Applicantsignature: Applicant printed name:Jonny.Matuichuk
Rollease Acmeda Inc Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 05-29-2023 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2AGGZ003B9ACA4C Rollease Acmeda Inc.certifiesthat, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Applicant signature: Applicant printed name:Jonny.Matuichuk
Rev 1/26/2023 Rollease Acmeda Inc Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 05-29-2023 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID:2AGGZ003B9ACA4C Rollease Acmeda Inc.certifies that, as of the date of the filing of the application, we designate ourselves as the U. S. agent for service of process. Designated U.S. Agent Information: FRN: 0025043381 Name: Rollease Acmeda Inc Address: 7th Floor / 750 East Main Street,Stamford, CT 06902, USA Contact Person: Jonny.Matuichuk Tel.:2034906191 Email:[email protected] Sincerely, Jonny.Matuichuk
Rev 11/20/07 Rollease Acmeda Inc Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID:2AGGZ003B9ACA4C . Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name (Block Diagram, Schematics, Operation description) (Block Diagram, Schematics, Operation description.pdf”) The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Pursuant to DA04-1705 June 15, 2004 of the Commission’s public notice, we also request temporary confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name (Internal Photos, Test Setup Photos, User manual) (Internal Photos, Test Setup Photos, User manual.pdf”) Number of days: 180 days Sincerely, (signature) (printed name)Jonny.Matuichuk
C:\Users\jonny.matuichuk\Downloads\Certification\More\FCC IC application Form-1225 mm Motors\FCC IC application Form-1225 mm Motors\FCC POA _Letter.docx Rollease Acmeda Inc Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date: May 29,2023 SUBJECT: FCC Application for FCC ID:2AGGZ003B9ACA4C To Whom It May Concern: We, the undersigned, hereby authorize Yu Anlu at TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Regards, PrintedName: Jonny.Matuichuk Signature:
RolleaseAcmeda Inc Date:2023-05-29 To: Federal Communications Commission 7435 Oakland Mills Road Columbia MD FCC ID:2AGGZ003B9ACA4C To Whom It May Concern: This letter is to ascertain that RolleaseAcmeda Inc Product name: Tubular Motor, Model: MT01-1225-069002-S, MT01-1225-069004-S have been the units used for conducting FCC compliance testing, the SDoC part will be tested by FCC recognized test lab. If you have any question or concerns, please contact us. Sincerely, Signature Company name:RolleaseAcmeda Inc Address:7th Floor / 750 East Main Street,Stamford, CT 06902, USA E- mail:[email protected] Tel:2034906191 Printed Name:Jonny.Matuichuk
1 of 1 To whom it may concern, Letter of Declaration We, Rollease Acmeda Inc, hereby declare the models below: Model(S): MT01-1225-069002-S, MT01-1225-069004-S FCC ID: 2AGGZ003B9ACA4C IC ID: 21769-003B9ACA4C are identical in electrical and mechanical construction except for the model number, and end-cap adaptor. For the end cap adaptor, the only change is the adaptor’s profile as shown in the below table: Print name: Jonny Matuichuk Title: Product Manager Signature /Date: RA CodeDescription MT01-1225-069002-S AUTOMATE | DC 1.1Nm ARC Motor[Ø25/12V/20rpm](SKY) MT01-1225-069004-S AUTOMATE | DC 1.1Nm ARC Motor[Ø25/12V/20rpm](S45) Adaptor DC 25 Motor 25/05/2023
External Photos Documentation Manufacturer: Rollease Acmeda Inc Page 1 of 3 Product: DC 2.0Nm ARC Motor FCC ID: 2AGGZ003B9ACA4D IC: 21769-003B9ACA4D Model: MT01-1228-069004-S External Photos Documentation Manufacturer: Rollease Acmeda Inc Page 2 of 3 Product: DC 2.0Nm ARC Motor FCC ID: 2AGGZ003B9ACA4D IC: 21769-003B9ACA4D Model: MT01-1228-069004-S External Photos Documentation Manufacturer: Rollease Acmeda Inc Page 3 of 3 Product: DC 2.0Nm ARC Motor FCC ID: 2AGGZ003B9ACA4D IC: 21769-003B9ACA4D Model: MT01-1228-069004-S
External Photos Documentation Manufacturer: Rollease Acmeda Inc Page 1 of 3 Product: DC 1.1Nm ARC Motor FCC ID: 2AGGZ003B9ACA4C IC: 21769-003B9ACA4C Model: MT01-1225-069002-S External Photos Documentation Manufacturer: Rollease Acmeda Inc Page 2 of 3 Product: DC 1.1Nm ARC Motor FCC ID: 2AGGZ003B9ACA4C IC: 21769-003B9ACA4C Model: MT01-1225-069002-S External Photos Documentation Manufacturer: Rollease Acmeda Inc Page 3 of 3 Product: DC 1.1Nm ARC Motor FCC ID: 2AGGZ003B9ACA4C IC: 21769-003B9ACA4C Model: MT01-1225-069002-S
label position
Internal Photos Documentation Manufacturer: Rollease Acmeda Inc Page 1 of 7 Product: DC 1.1Nm ARC Motor FCC ID: 2AGGZ003B9ACA4C IC: 21769-003B9ACA4C Model: MT01-1225-069002-S Antenna for SRD Internal Photos Documentation Manufacturer: Rollease Acmeda Inc Page 2 of 7 Product: DC 1.1Nm ARC Motor FCC ID: 2AGGZ003B9ACA4C IC: 21769-003B9ACA4C Model: MT01-1225-069002-S Internal Photos Documentation Manufacturer: Rollease Acmeda Inc Page 3 of 7 Product: DC 1.1Nm ARC Motor FCC ID: 2AGGZ003B9ACA4C IC: 21769-003B9ACA4C Model: MT01-1225-069002-S Internal Photos Documentation Manufacturer: Rollease Acmeda Inc Page 4 of 7 Product: DC 1.1Nm ARC Motor FCC ID: 2AGGZ003B9ACA4C IC: 21769-003B9ACA4C Model: MT01-1225-069002-S Internal Photos Documentation Manufacturer: Rollease Acmeda Inc Page 5 of 7 Product: DC 1.1Nm ARC Motor FCC ID: 2AGGZ003B9ACA4C IC: 21769-003B9ACA4C Model: MT01-1225-069002-S Internal Photos Documentation Manufacturer: Rollease Acmeda Inc Page 6 of 7 Product: DC 1.1Nm ARC Motor FCC ID: 2AGGZ003B9ACA4C IC: 21769-003B9ACA4C Model: MT01-1225-069002-S Internal Photos Documentation Manufacturer: Rollease Acmeda Inc Page 7 of 7 Product: DC 1.1Nm ARC Motor FCC ID: 2AGGZ003B9ACA4C IC: 21769-003B9ACA4C Model: MT01-1225-069002-S
Internal Photos Documentation Manufacturer: Rollease Acmeda Inc Page 1 of 7 Product: DC 1.1Nm ARC Motor FCC ID: 2AGGZ003B9ACA4C IC: 21769-003B9ACA4C Model: MT01-1225-069004-S Antenna for SRD Internal Photos Documentation Manufacturer: Rollease Acmeda Inc Page 2 of 7 Product: DC 1.1Nm ARC Motor FCC ID: 2AGGZ003B9ACA4C IC: 21769-003B9ACA4C Model: MT01-1225-069004-S Internal Photos Documentation Manufacturer: Rollease Acmeda Inc Page 3 of 7 Product: DC 1.1Nm ARC Motor FCC ID: 2AGGZ003B9ACA4C IC: 21769-003B9ACA4C Model: MT01-1225-069004-S Internal Photos Documentation Manufacturer: Rollease Acmeda Inc Page 4 of 7 Product: DC 1.1Nm ARC Motor FCC ID: 2AGGZ003B9ACA4C IC: 21769-003B9ACA4C Model: MT01-1225-069004-S Internal Photos Documentation Manufacturer: Rollease Acmeda Inc Page 5 of 7 Product: DC 1.1Nm ARC Motor FCC ID: 2AGGZ003B9ACA4C IC: 21769-003B9ACA4C Model: MT01-1225-069004-S Internal Photos Documentation Manufacturer: Rollease Acmeda Inc Page 6 of 7 Product: DC 1.1Nm ARC Motor FCC ID: 2AGGZ003B9ACA4C IC: 21769-003B9ACA4C Model: MT01-1225-069004-S Internal Photos Documentation Manufacturer: Rollease Acmeda Inc Page 7 of 7 Product: DC 1.1Nm ARC Motor FCC ID: 2AGGZ003B9ACA4C IC: 21769-003B9ACA4C Model: MT01-1225-069004-S
Report No: 709502303618-00B EMC_SHA_F_R_02.06E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 1 of 2 Rev. 20.00 MPE Calculation Applicant: Rollease Acmeda Inc Address: 7th Floor / 750 East Main Street, Stamford, CT 06902, USA Product: DC 1.1Nm ARC Motor FCC ID: 2AGGZ003B9ACA4C Model No.: MT01-1225-069002-S, MT01-1225-069004-S Reference RF report # 709502303618-00A According to subpart 15.247(i)and subpart §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091) (B) Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (minutes) 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f²) 30 30–300 27.5 0.073 0.2 30 300–1,500 / / f/1500 30 1,500–100,000 / / 1.0 30 f = frequency in MHz; * = Plane-wave equivalent power density; According to §1.1310 and §2.1091 RF exposure is calculated. Calculated Formulary: Predication of MPE limit at a given distance S = PG/4πR² = power density (in appropriate units, e.g. mW/cm 2 ); P = power input to the antenna (in appropriate units, e.g., mW); G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain factor, is normally numeric gain; R = distance to the center of radiation of the antenna (appropriate units, e.g., cm); Report No: 709502303618-00B EMC_SHA_F_R_02.06E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 2 of 2 Rev. 20.00 Calculation method for 433.92MHz Per the test report included herein, for 433.92MHz According to C63.10 Annex G EIRP = pt × gt =(E × d) 2 /30 where pt is the transmitter output power in watts gt is the numeric gain of the transmitting antenna (dimensionless) E is the electric field strength in V/m d is the measurement distance in meters (m) transmitter output power for 433.92MHz Function Field strength (E): 83.404 (dBuV/m) = 0.0148 (V/m) Measurement Distance(dMeas): 3 (m) Equivalent Isotropically Radiated Power(EIRP): 0.000066W=0.066mW According to §1.1310 and §2.1091 RF exposure is calculated. Calculated Formulary: Predication of MPE limit at a given distance S = PG/4πR² = power density (in appropriate units, e.g. mW/cm 2 ); PG = 0.066mW (in appropriate units, e.g., mW); R = distance to the center of radiation of the antenna (appropriate units, e.g., cm); Calculated Data: The max power density 0.066/4πR²= 1.313*10 -5 (mW/cm 2 ) < 0.28928 (mW/cm 2 ) Result: Compliant - TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch Reviewed by: Prepared by: Tested by: _____________________ _____________________ ______________________ Hui TONG Wenqiang LU Yiquan WANG EMC Section Manager EMC Project Engineer EMC Test Engineer Date: 2023-07-03 Date: 2027-07-03 Date: 2023-07-03
Report Number: 709502303618-00A EMC_SHA_F_R_02.05E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 1 of 25 Rev. 171.00 FCC/IC- TEST REPORT Report Number : 709502303618-00A Date of Issue: June 28, 2023 Model : MT01-1225-069002-S, MT01-1225-069004-S Product Type : DC 1.1Nm ARC Motor Applicant : Rollease Acmeda Inc Address : 7th Floor / 750 East Main Street, Stamford, CT 06902, USA Production Facility : Ningbo Dooya Mechanic & Electronic Technology Co., Ltd. Address : No.168 Shengguang Road, Luotuo, Zhenhai 315202 Ningbo, : Zhejiang province People's Republic of China Test Result : ◼ Positive Negative Total pages including Appendices : 25 TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined in ISO 17025. TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch reports apply only to the specific samples tested under stated test conditions. Construction of the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch shall have no liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval. dc Report Number: 709502303618-00A EMC_SHA_F_R_02.05E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 2 of 25 Rev. 171.00 1 Table of Contents 1 Table of Contents .................................................................................................................. 2 2 Details about the Test Laboratory .......................................................................................... 3 3 Description of the Equipment Under Test .............................................................................. 4 4 Summary of Test Standards .................................................................................................. 5 5 Summary of Test Results ...................................................................................................... 6 6 General Remarks .................................................................................................................. 7 7 Systems test configuration .................................................................................................... 8 8 Test Setups ........................................................................................................................... 9 9 Test Methodology ................................................................................................................ 10 9.1 Conducted Emission ..................................................................................................... 10 9.2 Radiated Emission ........................................................................................................ 15 9.3 Bandwidth Measurement & 99% Occupied Bandwidth ................................................. 19 9.4 Deactivation Time ......................................................................................................... 21 10 Test Equipment List ............................................................................................................. 22 11 System Measurement Uncertainty ...................................................................................... 23 12 Photographs of Test Set-ups ............................................................................................ 24 13 Photographs of EUT ........................................................................................................ 25 Report Number: 709502303618-00A EMC_SHA_F_R_02.05E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 3 of 25 Rev. 171.00 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch No.16 Lane, 1951 Du Hui Road, Shanghai 201108, P.R. China FCC Registration Number: 820234 Designation Number: CN1183 IC Company Number: 25988 CAB identifier: CN0101 Telephone: +86 21 6141 0123 Fax: +86 21 6140 8600 Report Number: 709502303618-00A EMC_SHA_F_R_02.05E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 4 of 25 Rev. 171.00 3 Description of the Equipment Under Test Product: DC 1.1Nm ARC Motor Model no./HVIN: MT01-1225-069002-S, MT01-1225-069004-S FCC ID: 2AGGZ003B9ACA4C IC: 21769-003B9ACA4C Rating: DC 12V RF Transmission Frequency: 433.925 MHz No. of Operated Channel: 1 Modulation: 2GFSK Antenna Type: Line Antenna Antenna Gain: 0.5 dBi for 433.92MHz SRD Description of the EUT: The Equipment Under Test (EUT) is a DC 1.1Nm ARC Motor with SRD function. We tested it and listed the worst data in this report. Test sample no.: SHA-732453-10 The sample’s mentioned in this report is/are submitted/ supplied/ manufactured by client. The laboratory therefore assumes no responsibility for…
Text truncated - open the document above for the full version.
Manufacturer: Rollease Acmeda Inc Product: DC 1.1Nm ARC Motor FCC ID: 2AGGZ003B9ACA4C IC: 21769-003B9ACA4C ©2023 Not to be reproduced, except in its entirety, Page 1 of 2 without the Permission of TÜ V SÜ D Certification and Testing (China) Co., Ltd. Shanghai Branch PHOTOGRAPHS OF TEST SET UP Field Strength and Harmonics Test Setup Radiated Emission Setup 30MHz ~ 1GHz 1GHz ~ 4.5GHz Manufacturer: Rollease Acmeda Inc Product: DC 1.1Nm ARC Motor FCC ID: 2AGGZ003B9ACA4C IC: 21769-003B9ACA4C ©2023 Not to be reproduced, except in its entirety, Page 2 of 2 without the Permission of TÜ V SÜ D Certification and Testing (China) Co., Ltd. Shanghai Branch Conducted emission Test Setup
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |

VT Tilt Motor
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Transmitter(Push one channel remote)
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Li-ion 0.5Nm ARC Motor
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
DC 2.0Nm ARC Motor
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Li-ion 1.1Nm ARC Motor
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver