FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Rollease Acmeda Inc/
  3. 2AGGZ003B9ACA56

2AGGZ003B9ACA565CH Remote Control

Rollease Acmeda Inc
5CH Remote Control - FCC ID 2AGGZ003B9ACA56 - Rollease Acmeda Inc
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jul 03, 2023
Application Purpose
Original Equipment
Date of Application
Jul 03, 2023
Equipment Note
5CH Remote Control
Frequency Range
433.92000000 - 433.92000000
Company
Rollease Acmeda Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

ID Label/Location Info

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

MT02-0101-069011 5CH Remote Control 01 Remote Controller Buttons 1. The transmitter should not be exposed to moisture or impact, so as not to affect its life. 2. During use, when the remote control distance is significantly shorter or less sensitive, please check whether the battery needs to be replaced. 3. When the voltage is too low, orange LED will flicker during operation, indicating to replace the battery. 4. Please properly dispose of used batteries according to the local garbage classification and recycling policy. 04 Instruction a. Prohibit Dual-key Operation ①Press “Prg” x10s, LED flickers trice ②Repeat the above, dual-key operation activated Note: When dual-key operation prohibited, these programming setting function are not allowed b. Number of Channels Setting Press”CH-” & “CH+” together for 3s, LED flickers trice, short press”CH-” or “CH+”, then short press “Stop”,LED flickers twice. Note: When all LEDs are lit, that is channel 0 (All channels move together). C. For other operations, please refer to the motor operation instruction FCC Compliance This device complies with Part 15 of the FCC Rules / Innovation, Science and EconomicDevelopment Canada’s licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. L’émetteur/récepteur exempt de licencecontenu dans le présentappareilestconforme aux CNR d’Innovation, Sciences et Développementéconomique Canada applicables aux appareils radio exempts de licence. L’exploitationestautorisée aux deux conditions suivantes : (1) L’appareil ne doit pas produire de brouillage; (2) L’appareil doit accepter tout brouillageradioélectriquesubi, mêmesi le brouillageest susceptible d’encompromettre le fonctionnement. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help.

Attestation Statements

Rev 1/26/2023 Rollease Acmeda Inc Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 06-29-2023 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2AGGZ003B9ACA56 Rollease Acmeda Inc. certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Applicant signature: Applicant printed name: Jonny.Matuichuk

Attestation Statements

Rollease Acmeda Inc Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 06-29-2023 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2AGGZ003B9ACA56 Rollease Acmeda Inc. certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Applicant signature: Applicant printed name: Jonny.Matuichuk

Attestation Statements

Rev 1/26/2023 Rollease Acmeda Inc Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 06-29-2023 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: 2AGGZ003B9ACA56 Rollease Acmeda Inc. certifies that, as of the date of the filing of the application, we designate ourselves as the U.S. agent for service of process. Designated U.S. Agent Information: FRN: 0025043381 Name: Rollease Acmeda Inc Address: 7th Floor / 750 East Main Street,Stamford, CT 06902, USA Contact Person: Jonny.Matuichuk Tel.: 2034906191 Email: [email protected] Sincerely, Jonny.Matuichuk

Cover Letter(s)

Rev 11/20/07 Rollease Acmeda Inc Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: 2AGGZ003B9ACA56 . Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name (Block Diagram, Schematics, Operation description) (Block Diagram, Schematics, Operation description.pdf”) The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Pursuant to DA04-1705 June 15, 2004 of the Commission’s public notice, we also request temporary confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name (Internal Photos, Test Setup Photos, User manual) (Internal Photos, Test Setup Photos, User manual.pdf”) Number of days: 180 days Sincerely, (signature) (printed name) Jonny.Matuichuk

Cover Letter(s)

C:\Users\xu-jx\Desktop\back up\Project\2023\Zhejiang Jiecang Linear Motion Technology Co., Ltd\709502303930-00\FCC POA _Letter.docx Rollease Acmeda Inc Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date: June 29,2023 SUBJECT: FCC Application for FCC ID: 2AGGZ003B9ACA56 To Whom It May Concern: We, the undersigned, hereby authorize Yu Anlu at TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Regards, Printed Name: Jonny.Matuichuk Signature:

Internal Photos

Internal Photos Documentation Applicant: Rollease Acmeda Inc Page 1 of 4 Product: 5CH Remote Control FCC ID: 2AGGZ003B9ACA56 IC:21769-003B9ACA56 Internal Photos Documentation Applicant: Rollease Acmeda Inc Page 2 of 4 Product: 5CH Remote Control FCC ID: 2AGGZ003B9ACA56 IC:21769-003B9ACA56 Antenna for 433.92MHz Internal Photos Documentation Applicant: Rollease Acmeda Inc Page 3 of 4 Product: 5CH Remote Control FCC ID: 2AGGZ003B9ACA56 IC:21769-003B9ACA56 Internal Photos Documentation Applicant: Rollease Acmeda Inc Page 4 of 4 Product: 5CH Remote Control FCC ID: 2AGGZ003B9ACA56 IC:21769-003B9ACA56

RF Exposure Info

Report No: 709502303930-00B EMC_SHA_F_R_02.06E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 1 of 2 Rev. 171.00 RF Exposure Estimation 1. Introduction Applicant: Rollease Acmeda Inc Address: 7th Floor / 750 East Main Street, Stamford, CT 06902, USA Product: 5CH Remote Control FCC ID: 2AGGZ003B9ACA56 Model No.: MT02-0101-069011 Reference RF report # 709502303930-00A 2. B.2 Blanket 1 mW Blanket Exemption According to KDB 447498 D04, the 1 mW Blanket Exemption of § 1.1307(b)(3)(i)(A) applies for single fixed, mobile, and portable RF sources with available maximum time-averaged power of no more than 1 mW, regardless of separation distance. The 1 mW blanket exemption applies at separation distances less than 0.5 cm, including where there is no separation. This exemption shall not be used in conjunction with other exemption criteria other than those for multiple RF sources in paragraph § 1.1307(b)(3)(ii)(A). The 1 mW exemption is independent of service type and covers the full range of 100 kHz to 100 GHz, but it shall not be used in conjunction with other exemption criteria or in devices with higher-power transmitters operating in the same time-averaging period. Exposure from such higher-power transmitters would invalidate the underlying assumption that exposure from the lower-power transmitter is the only contributor to SAR in the relevant volume of tissue. 3. RF Exposure Evaluation Per the test report included herein, for 433.92MHz According to C63.10 Annex G EIRP = pt × gt =( E × d) 2 /30, so pt=( E × d) 2 /30* gt where pt is the transmitter output power in watts gt is the numeric gain of the transmitting antenna (dimensionless) E is the electric field strength in V/m d is the measurement distance in meters (m) transmitter output power for 433.92MHz Function Field strength (E): 71.99 (dBuV/m) = 0.0040 (V/m) Measurement distance (D): 3 (m) Antenna Gain, typical (dBi): -17.4275 Numerical gain of the transmit antenna (gt): 0.02 Transmitter output power (TP): 0.000262(W) Transmitter output power (TP): 0.262(mW) Report No: 709502303930-00B EMC_SHA_F_R_02.06E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 2 of 2 Rev. 171.00 We used the maximum ERP/EIRP to perform RF exposure exemption evaluation. Evaluation method Exempt Limit (mW) Verdict ◼ Blanket 1 mW Blanket Exemption 1mW Yes  MPE-based Exemption (ERP) 7mW (ERP) N/A  SAR-based Exemption (Pth) 3060mW N/A So, the device is qualified for SAR test exemption, the exemption report is in lieu of the SAR report. - TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch Reviewed by: Prepared by: Tested by: _____________________ _____________________ ______________________ Hui TONG Jiaxi XU Cheng Huali EMC Section Manager EMC Project Engineer EMC Test Engineer Date: June 30, 2023 Date: June 30, 2023 Date: June 30, 2023 -------------------------------------------------------End of Test Report--------------------------------------------------------------------

Test Report

Report Number: 709502303930-00A EMC_SHA_F_R_02.05E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 1 of 19 Rev. 171.00 FCC/IC TEST REPORT Report Number : 709502303930-00A Date of Issue: June 30, 2023 Model : MT02-0101-069011 Product Type : 5CH Remote Control Applicant : Rollease Acmeda Inc Address : 7th Floor / 750 East Main Street, Stamford, CT 06902, USA Production Facility : ZHEJIANG JIECANG LINEAR MOTION TECHNOLOGY CO., LTD Address : No.19 XinTao Road, Provincial High Tech Park, XINCHANG ZHEJIANG 312500 China. Test Result : ◼ Positive  Negative Total pages including Appendices : 19 TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined in ISO 17025. TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch reports apply only to the specific samples tested under stated test conditions. Construction of the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch shall have no liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval. dc Report Number: 709502303930-00A EMC_SHA_F_R_02.05E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 2 of 19 Rev. 171.00 1 Table of Contents 1 Table of Contents ................................................................................................................................................................... 2 2 Details about the Test Laboratory .......................................................................................................................................... 3 3 Description of the Equipment Under Test ............................................................................................................................. 4 4 Summary of Test Standards ................................................................................................................................................... 5 5 Summary of Test Results ....................................................................................................................................................... 6 6 General Remarks .................................................................................................................................................................... 7 7 Systems test configuration ..................................................................................................................................................... 8 8 Test Setups ............................................................................................................................................................................. 9 9 Test Methodology ................................................................................................................................................................ 10 9.1 Radiated Emission ....................................................................................................................................................... 10 9.2 Bandwidth Measurement ............................................................................................................................................ 15 9.3 Deactivation Time ....................................................................................................................................................... 17 10 Test Equipment List ............................................................................................................................................................. 18 11 System Measurement Uncertainty ....................................................................................................................................... 19 Report Number: 709502303930-00A EMC_SHA_F_R_02.05E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 3 of 19 Rev. 171.00 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch No.16 Lane, 1951 Du Hui Road, Shanghai 201108, P.R. China Test Firm FCC Registration Number: Designation number: 820234 CN1183 IC Company Number: CAB identifier: 25988 CN0101 Telephone: +86 21 6141 0123 Fax: +86 21 6140 8600 Report Number: 709502303930-00A EMC_SHA_F_R_02.05E TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch 3-13, No.151, Heng Tong Road, Shanghai, 200070, P.R. China Phone: +86 21 61410123, Fax:+86 21 61408600 Page 4 of 19 Rev. 171.00 3 Description of the Equipment Under Test Product: 5CH Remote Control Model no./HVIN/PMN: MT02-0101-069011 FCC ID: IC: 2AGGZ003B9ACA56 21769-003B9ACA56 Rating: DC 3V RF Transmission Frequency: 433.92MHz Modulation: ASK Antenna Type: PCB antenna Antenna Gain: -17.4275dBi Description of the EUT: The Equipment Under Test (EUT) was a 5CH Remote Control, transmit operated at 433.92MHz. Test sample …

Text truncated - open the document above for the full version.

Test Setup Photos

Applicant: Rollease Acmeda Inc Product: 5 CH Remote Control FCC ID: 2AGGZ003B9ACA56 IC:21769-003B9ACA56 ©2023 Not to be reproduced, except in its entirety, Page 1 of 1 without the Permission of TÜ V SÜ D Certification and Testing (China) Co., Ltd. Shanghai Branch PHOTOGRAPHS OF TEST SET UP Field Strength and Harmonics Test Setup Radiated Emission Setup 30MHz ~ 1GHz 1GHz ~ 4.5GHz

Contact Information

Applicant

Jonny Emilio Matuichuk(Product Manager - Motorization)
[email protected]2034906191Fax: 2039641503

Test Firm

TUV SUD Certification and Testing (China) Co., LtdYi Ba
[email protected]86 21 6140 0132

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term

Other Applications from Rollease Acmeda Inc

VT Tilt Motor - FCC ID 2AGGZ003B9ACA49 - Rollease Acmeda Inc
2AGGZ003B9ACA49

VT Tilt Motor

Jul 27, 2023

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Transmitter(Push one channel remote) - FCC ID 2AGGZ003B9ACA50 - Rollease Acmeda Inc
2AGGZ003B9ACA50

Transmitter(Push one channel remote)

Jul 26, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Li-ion 0.5Nm ARC Motor - FCC ID 2AGGZ003B9ACA51 - Rollease Acmeda Inc
2AGGZ003B9ACA51

Li-ion 0.5Nm ARC Motor

Jul 22, 2023

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
DC 1.1Nm ARC Motor - FCC ID 2AGGZ003B9ACA4C - Rollease Acmeda Inc
2AGGZ003B9ACA4C

DC 1.1Nm ARC Motor

Jul 08, 2023

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
DC 2.0Nm ARC Motor - FCC ID 2AGGZ003B9ACA4D - Rollease Acmeda Inc
2AGGZ003B9ACA4D

DC 2.0Nm ARC Motor

Jul 08, 2023

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver