Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
AUTOMATE ™ V2 MOTOR PROGRAMMING INSTRUCTIONS SOFT STOP SOLAR OPTION FAVORITE POSITION SELECTABLE SPEED BATTERY POWERED USB CHARGEELECTRONIC LIMIT LEVEL CONTROL BATTERY CHECK433 MHZ BI-DIRECTIONAL PART NUMBERDESCRIPTION MT01-1325-069001AUTOMATE | Li-ion 1.1Nm ARC Motor [Ø25/5V/20rpm] (Skyline Short) MT01-1325-069002AUTOMATE | Li-ion 1.1Nm ARC Motor [Ø25/5V/20rpm] (Skyline) MT01-1325-069003AUTOMATE | Li-ion 1.1Nm ARC Motor [Ø25/5V/20rpm] (S45) MT01-1325-069005AUTOMATE | Li-ion 1.1Nm ARC Motor [Ø25/5V/20rpm] (S45 Short) MT01-1328-069001AUTOMATE | Li-ion 2.0Nm ARC Motor [Ø28/5V/20rpm] (Skyline) MT01-1328-069002AUTOMATE | Li-ion 2.0Nm ARC Motor [Ø28/5V/20rpm] (S45) MT01-1335-069001AUTOMATE | Li-ion 3.0Nm ARC Motor [Ø35/5V/20rpm] MT01-1345-069001AUTOMATE | Li-ion Q3.0Nm ARC Motor [Ø45/5V/20rpm] MT01-1345-069002AUTOMATE | Li-ion 10.0Nm ARC Motor [Ø45/5V/9rpm] • USE THIS DOCUMENT WITH THE FOLLOWING MOTORS: AUTOMATE V2_PRGM_JANUARY_2020 Soft StopBattery CheckUSB Charge Soft StopBattery CheckUSB Charge Soft StopBattery CheckUSB Charge 2 | Automate ™ Programming Instructions | Li-ion Tubular Motors ROLLEASE ACMEDA SAFETY INSTRUCTIONS WARNING: Important safety instructions to be read before installation. Incorrect installation can lead to serious injury and will void manufacturer’s liability and warranty. WARNING: Important safety instructions to be read before installation and use. Incorrect installation or use can lead to serious injury and will void manufacturer’s liability and warranty. It is important for the safety of persons to follow the enclosed instructions. Save these instructions for future reference. • Do not expose to water, moisture, humid and damp environments or extreme temperatures. • Persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge should not be allowed to use this product. • Use or modification outside the scope of this instruction manual will void warranty. • Installation and programming to be performed by a suitably qualified installer. • Follow installation instructions. • For use with motorized shading devices. • Keep away from children. • Frequently inspect for improper operation. Do not use if repair or adjustment is necessary. • Keep clear when in operation. • Replace battery with correctly specified type. Rollease Acmeda declares this equipment is in compliance with the essential requirements and other relevant provisions of RED Directive 2014/53/EU. Do not dispose of in general waste. Please recycle batteries and damaged electrical products appropriately. Statement Regarding FCC Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. •Consult the dealer or an experienced radio/TV technician for help. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Statement Regarding IC Compliance 1. This device complies with Industry Canada RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. -French: Leprésent appareil est conforme aux CNR d’Industrie Canada applicable aux appareils radio Exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, meme si le brouillage est susceptible d’en compromettre le fonctionnement.” CAN ICES-3 (B)/NMB-3(B) ROLLEASE ACMEDA Automate ™ Programming Instructions | Li-ion Tubular Motors | 3 CONTENTS 1 ASSEMBLY 4 2 RETROFIT INSTALLATION 5 3 CHARGING 5 4 P1 BUTTON FUNCTIONS 6 4.1 Motor state test 6 4.2 Motor configuration options 6 5 INITIAL SET UP 7 5.1 Pair motor with controller 7 5.2 Check motor direction 7 5.3 Set Limits 8 6 ADJUSTING LIMITS 9 6.1 Adjust upper limit 9 6.2 Adjust lower limit 9 7 CONTROLLERS AND CHANNELS 10 7.1 Using P2 Button on existing controller to add a new controller or channel 10 7.2 Using a pre-existing controller to add or delete a controller or channel 10 8 FAVORITE POSITIONING 11 8.1 Set a favorite position 11 8.2 Send shade to favorite position 11 8.3 Delete favorite position 11 9 TILT & ROLLER MODE 12 9.1 Toggle motor to Tilt Mode 12 9.2 Toggle Motor to Roller Mode 12 10 ADJUSTING SPEED 13 10.1 Increase Motor Speed 13 10.2 Decrease Motor Speed 13 11 SOFT STOP CONFIGURATION 14 11.1 Turn Soft Stop OFF 14 11.2 Turn Soft Stop ON 14 12 BATTERY CHECK FUNCTION …
Text truncated - open the document above for the full version.
file: declaration letter-template Page 1 of 1 To: TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Attention: From: Date: April 14, 2020 Fax No: 86 755 8828 5299 Total Page (Cover Included): 1 Project No.: Subject: Declaration letter We: Company Name Rollease Acmeda Inc Address 750 East Main Street, 7th Floor, Stamford Connecticut United States 06902 Officially notify TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch that the <<Model A>> have the same technical construction including circuit diagram, PCB Layout, components and component layout, all electrical construction and mechanical construction, with <<PRODUCT>>, <<Model B>>. The difference lies only in software of the different models. The software will not affect the radio parameters. <<Model A>>: MT01-1325-069002, MT01-1325-069003, MT01-1325-069005 <<Model B>>: MT01-1325-069001 <<Product>>: Tubular motor Applicant: Rollease Acmeda Inc 2020-04-07 ___________ __________________________________________ (Date) (Applicant’s authorized signature and company Chop)
Date (10/30/2019) TUV SUD BABT TCB Octagon House, Segensworth Road, Fareham, Hampshire, P015 .5RL Confidentiality Request FCC ID: 2AGGZMT011325069002 Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission's Rules, Rollease Acmeda Inc hereby requests permanent confidential treatment of information accompanying this application as outlined below: Schematics Bill of Materials/Parts List Block Diagrams Theory of Operation Rollease Acmeda Inc also hereby requests short-term confidential treatment of information accompanying this application as outlined below for a period of (180) days: Internal Photos External Photos User Manual Test Set-up Photographs The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Yours sincerely, Company Officer/Name: Program Manager Motorization/ Jere Gianola Telephone Number: 7202037285 Extension: Email: [email protected]
EMC_SZ_FR_20.00 E-I Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 3 External Photos Model: MT01-1325-069001 EMC_SZ_FR_20.00 E-I Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 3 EMC_SZ_FR_20.00 E-I Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 3
Label Location MT01-1325-069001 AUTOMATE | LI-ION 1.1Nm ARC Motor [Ø25/5V/20rpm] (Skyline-SHORT)
Label Location MT01-1325-069002 AUTOMATE | Li-ion 1.1Nm ARC Motor [Ø25/5V/20rpm] (Skyline)
Label Location MT01-1325-069003 AUTOMATE | LI-ION 1.1Nm ARC Motor [Ø25/5V/20rpm] (S45)
Label Location MT01-1325-069005 AUTOMATE | LI-ION 1.1Nm ARC Motor [Ø25/5V/20rpm] (S45-SHORT)
09/JAN/2020 MT01-1325-069001 | v1.3 85x35mm Product Label Box Label 0.83A MT01-1325-069001 5V DC 433.925MHz I.CL.A 10W IP2012min0.43kg Li-ion 1.1Nm ARC Motor [Ø25/1.1Nm/20rpm (Skyline-Short)] MADE IN PRC 35x35mm Li-ion 1.1Nm ARC Motor [Ø25/1.1Nm/20rpm (Skyline-Short)] 0.43kg MT01-1325-069001 CAN ICES-3 (B)/NMB-3(B) IC: 21769-MT011325002 FCC ID: 2AGGZMT011325069002 FCC ID: 2AGGZMT011325069002 IC: 21769-MT011325002 2.2Ah This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
09/JAN/2020 MT01-1325-069002 | v2.2 85x35mm Product Label Box Label 0.83A MT01-1325-069002 5V DC 433.925MHz I.CL.A 10W IP2012min0.43kg Li-ion 1.1 ARC Motor [Ø25/1.1Nm/20rpm (Skyline)] MADE IN PRC 35x35mm Li-ion 1.1 ARC Motor [Ø25/1.1Nm/20rpm (Skyline)] 0.43kg MT01-1325-069002 CAN ICES-3 (B)/NMB-3(B) IC: 21769-MT011325002 FCC ID: 2AGGZMT011325069002 FCC ID: 2AGGZMT011325069002 IC: 21769-MT011325002 2.2Ah This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
09/JAN/2020 MT01-1325-069003 | v2.2 85x35mm Product Label Box Label 0.83A MT01-1325-069003 5V DC 433.925MHz I.CL.A 10W IP2012min0.43kg Li-ion 1.1 ARC Motor [Ø25/1.1Nm/20rpm (S45)] MADE IN PRC 35x35mm Li-ion 1.1 ARC Motor [Ø25/1.1Nm/20rpm (S45)] 0.43kg MT01-1325-069003 CAN ICES-3 (B)/NMB-3(B) IC: 21769-MT011325002 FCC ID: 2AGGZMT011325069002 FCC ID: 2AGGZMT011325069002 IC: 21769-MT011325002 2.2Ah This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
10/JAN/2020 MT01-1325-069005 | v1.3 85x35mm Product Label Box Label 0.83A MT01-1325-069005 5V DC 433.925MHz I.CL.A 10W IP2012min0.43kg Li-ion 1.1 ARC Motor [Ø25/1.1Nm/20rpm (S45-Short)] MADE IN PRC 35x35mm Li-ion 1.1 ARC Motor [Ø25/1.1Nm/20rpm (S45-Short)] 0.43kg MT01-1325-069005 CAN ICES-3 (B)/NMB-3(B) IC: 21769-MT011325002 FCC ID: 2AGGZMT011325069002 FCC ID: 2AGGZMT011325069002 IC: 21769-MT011325002 2.2Ah This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
EMC_SZ_FR_20.00 E-I Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 4 Internal Photos Model: MT01-1325-069001 EMC_SZ_FR_20.00 E-I Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 4 EMC_SZ_FR_20.00 E-I Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 4 RF Antenna EMC_SZ_FR_20.00 E-I Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 4 of 4
Report Number: 68.910.19.0020.01A TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 RF exposure Estimation for MT01-1328-069001, MT01-1328-069002 Introduction MT01-1325-069001, MT01-1325-069002, MT01-1325-069003, MT01-1325-069005 (FCC ID: 2AGGZMT011325069002) is a Tubular motor operating at 433.925MHz. 1.Limit and Guidelines on Exposure to Electromagnetic Fields According to 4.3 General SAR test exclusion guidance of KDB 447498 RF Exposure, no SAR required if power is lower than the flowing threshold: The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where • f(GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation25 • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.3 is applied to determine SAR test exclusion. 2.Calculation method [(max. power of` channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 According to ANSI C63.10-2013 (9.5 Equations to calculate EIRP), Report Number: 68.910.19.0020.01A TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 For 433.925 MHz. Field Strength (EMeas):92.14 (dBuV/m) (f=433.925 MHz) Measurement Distance(dMeas):3 (m) Equivalent Isotropically Radiated Power(EIRP):0.50 (mW) Radiated Power + tune up tolerance = 0.50mW Distance = 5 mm f = 433.925MHz [0.50/5] * SQRT (0.433925) =0.07 0.07 ≤ 3.0 Therefore, excluded from SAR testing. TUV SUD China, Shenzhen Branch Reviewed by: Prepared By: John Zhi/ EMC Project Manager Mark Chen/EMC Project Engineer Date: 2020-04-03 Date: 2020-04-03
Report Number: 68.910.19.0020.01 EMC_SZ_FR_21.00 FCC Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 19 FCC/IC - TEST REPORT Report Number:68.910.19.0020.01Date of Issue:February 27, 2020 Model:MT01-1325-069001, MT01-1325-069005, MT01-1325-069002, MT01-1325-069003 Product Type:Tubular motor Applicant:Rollease Acmeda Inc Address:750 East Main Street, 7th Floor, Stamford Connecticut :United States 06902 Production Facility: Ningbo Dooya Mechanic & Electronic TechnologyCo., Ltd. Address: No.168 Shengguang Road, Luotuo, Zhenhai, Ningbo, Zhejiang province, P.R.China 315202 Test Result:nPositiveoNegative Total pages including Appendices: 19 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined in ISO 17025. TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch reports apply only to the specific samples tested under stated test conditions. Construction of the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch shall have no liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval Report Number: 68.910.19.0020.01 EMC_SZ_FR_21.00 FCC Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 19 1 Table of Contents 1Table of Contents ........................................................................................................................................................... 2 2Details about the Test Laboratory.................................................................................................................................... 3 3Description of the Equipment Under Test ........................................................................................................................ 4 4Summary of Test Standards ............................................................................................................................................ 5 5Summary of Test Results ................................................................................................................................................ 6 6General Remarks ............................................................................................................................................................ 7 7Systems test configuration .............................................................................................................................................. 8 8Test Setups ..................................................................................................................................................................... 9 9Test Methodology......................................................................................................................................................... 10 9.1Conducted Emission ............................................................................................................................................. 10 9.2Radiated Emission ................................................................................................................................................ 13 9.3Bandwidth Measurement ...................................................................................................................................... 16 9.4Deactivation Time ................................................................................................................................................ 17 10Test Equipment List...................................................................................................................................................... 18 11System Measurement Uncertainty ................................................................................................................................. 19 Report Number: 68.910.19.0020.01 EMC_SZ_FR_21.00 FCC Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 19 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China FCC Registration Number: 514049 IC Registration Number: 10320A Telephone:86 755 8828 6998 Fax:86 755 8828 5299 Report Number: 68.910.19.0020.01 EMC_SZ_FR_21.00 FCC Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. C…
Text truncated - open the document above for the full version.
Test setup photos Conduction Emission Radiated Emission Test below 1GHz Radiated Emission Test above 1GHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.925 MHz - 433.925 MHz | - |

VT Tilt Motor
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Transmitter(Push one channel remote)
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Li-ion 0.5Nm ARC Motor
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
DC 1.1Nm ARC Motor
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
DC 2.0Nm ARC Motor
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver