FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. AKUVOX (XIAMEN) NETWORKS CO., LTD./
  3. 2AHCR-IT88A

2AHCR-IT88AIndoor Monitor

AKUVOX (XIAMEN) NETWORKS CO., LTD.
Indoor Monitor - FCC ID 2AHCR-IT88A - AKUVOX (XIAMEN) NETWORKS CO., LTD.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Dec 21, 2022
Application Purpose
Original Equipment
Date of Application
Dec 21, 2022
Equipment Note
Indoor Monitor
Frequency Range
2402.00000000 - 2480.00000000
Company
AKUVOX (XIAMEN) NETWORKS CO., LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

AboutThisManual ThankyouforchoosingtheAkuvoxIT88seriesindoormonitor.Thismanual isintendedfortheadministratorswhoneedtoproperlyconfiguretheindoor monitor.Thismanualappliestothe88.30.110.302version,anditprovidesall theconfigurationsforthefunctionsandfeaturesoftheIT88seriesdoor phone.PleasevisittheAkuvoxforumorconsulttechnicalsupportforany newinformationorthelatestfirmware. RelatedDocumentation Youareadvisedtorefertotherelateddocumentsformoretechnical informationviathelinkbelow: https://knowledge.akuvox.com AnyChangesormodificationsnotexpresslyapprovedbytheparty responsibleforcompliancecouldvoidtheuser'sauthoritytooperatethe equipment. Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjectto thefollowingtwoconditions:(1)Thisdevicemaynotcauseharmful interference,and(2)thisdevicemustacceptanyinterferencereceived, includinginterferencethatmaycauseundesiredoperation. Note:Thisequipmenthasbeentestedandfoundtocomplywiththelimitsfor aClassBdigitaldevice,pursuanttopart15oftheFCCRules. Theselimitsaredesignedtoprovidereasonableprotectionagainstharmful interferenceinaresidentialinstallation.Thisequipmentgenerates,usesand canradiateradiofrequencyenergyand,ifnotinstalledandusedin accordancewiththeinstructions,maycauseharmfulinterferencetoradio communications.However,thereisnoguaranteethatinterferencewillnot occurinaparticularinstallation.Ifthisequipmentdoescauseharmful interferencetoradioortelevisionreception,whichcanbedeterminedby turningtheequipmentoffandon,theuserisencouragedtotrytocorrectthe interferencebyoneormoreofthefollowingmeasures: — Reorientorrelocatethereceivingantenna. —Increasetheseparationbetweentheequipmentandreceiver. —Connecttheequipmentintoanoutletonacircuitdifferentfromthatto whichthereceiverisconnected. — Consultthedealeroranexperiencedradio/TVtechnicianforhelp. FCCRadiationExposureStatement: ThisequipmentcomplieswithFCCradiationexposurelimitssetforthforan uncontrolledenvironment. Thistransmittermustnotbeco‐locatedoroperatinginconjunctionwith anyotherantennaortransmitter. Thisequipmentshouldbeinstalledandoperatedwithminimumdistance 20cmbetweentheradiator&youbody. IT88SeriesAdministratorGuide AKUVOXSMARTINTERCOMwww.akuvox.com 4 1.ProductOverview IT88seriesisanAndroidSIP-basedwithasmoothtouch-screenindoor monitor.ItcanbeconnectedwiththeAkuvoxdoorphoneforaudio/video communication,unlocking,andmonitoring.Residentscancommunicatewith visitorsviaaudio/videocall,anditsupportsunlockingthedoorremotely.Itis moreconvenientandsaferforresidentstocheckthevisitor’sidentity throughitsvideopreviewfunction.IT88Aseriesareoftenappliedto scenariossuchasvillas,apartments,andbuildings. 2.ChangeLog Thechangelogwillbeupdatedherealongwiththechangesinthenew softwareversion IT88SeriesAdministratorGuide AKUVOXSMARTINTERCOMwww.akuvox.com 5 3.IntroductiontoConfigurationMenu Status:Thissectiongivesyoubasicinformationsuchasproductinformation, NetworkInformation,andaccountinformation,etc. Account:ThissectionconcernsSIPaccount,SIPserver,proxyserver, transportprotocoltype,audio&videocodec,DTMF,sessiontimer,etc. Network:ThissectionmainlydealswithDHCP&StaticIPsetting,RTPport setting,anddevicedeployment,etc. Phone:ThissectionincludesTime&language,callfeature,dialmanagement, dataimport&export,doorlog,webrelay. Contacts:Thissectionallowstheusertoconfigurethelocalcontactlist storeinthedevice. Upgrade:ThissectioncoversFirmwareupgrade,devicereset&reboot, configurationfileauto-provisioning,PCAP. Security:ThissectionisforPasswordmodification,accountstatus&session timeoutconfiguration,aswellasservicelocationswitching. Settings:ThissectionisincludingtheRTSPD&voiceassistancesetup. Arming:Thissectioncoverstheconfigurationincluding,armingzonesetting, armingmode,disarmcode,andalarmaction. Modeselection: Discoverymode:Itisaplugandplaysconfigurationmode.Akuvoxdevices willconfigurethemselvesautomaticallywhenuserspoweronthedevices andconnectthemtothenetwork.Itissupertime-savingmodeanditwill greatlybringusersconveniencebyreducingmanualoperations.Thismode requiresnopriorconfigurationspreviouslybytheadministrator. Cloudmode:AkuvoxSmartPlusisanall-in-onemanagementsystem. AkuvoxSmartPlusisthemobileservicethatallowsaudio,video,remote IT88SeriesAdministratorGuide AKUVOXSMARTINTERCOMwww.akuvox.com 6 accesscontrolbetweensmartphonesandAkuvoxintercoms.All configurationsinthedevicewillbeissuedautomaticallyfromthecloud.If usersdecidetouseAkuvoxSmartPlus,pleasecontactAkuvoxtechnical support,andtheywillhelpyouconfiguretherelatedsettingsbeforeusing them. SDMCmode:SDMC(SIPDeviceManagementController)isasimpleand comprehensivesoftwareforbuildingmanagement.Itprovidesatopography foracommunitywhileofferingyouagraphicalconfigurationinterfaceforthe dooraccess,intercom,monitoring,alarm,etc.Itisaconvenienttoolfor propertymanagerstomanage,operate,andmaintainthecommunity. Toolselection Akuvoxhasmanyconfigurationtoolsforyoutosetupdevicesmore conveniently.Herewelistsomecommontools,pleasecontactyour administratortogetthetoolifyouneedthem. 1.SDMC:SDMCissuitableforthemanagementofAkuvoxdevicesinlarge communities,includingaccesscontrol,residentinformation,remote devicecontrol,etc. 2.AkuvoxUpgradetool:upgradeAkuvoxdevicesinbatchonaLAN(Local AreaNetwork) 3.AkuvoxPCManager:distributeallconfigurationitemsinbatchonaLAN. 4.IPscanner:itisusedtosearchAkuvoxdeviceIPaddressesonaLAN. 5.FacePro:managefacedatainbatchforthedoorphoneonaLAN. IT88SeriesAdministratorGuide AKUVOXSMARTINTERCOMwww.akuvox.com 7 4.AccesstheDevice Akuvoxindoormonitorsystemsettingscanbeeitheraccessedonthedevice directlyoronthedevicewebinterface. 4.1.DeviceStart-upNetworkSelection Akuvoxindoormonitorsystemsettingscanbeeitheraccessedonthedevice directlyoronthedevice'swebinterface.Afterthedevicebootsupinitially, youarerequiredtoselectthenetworkconnectionforthedevice.Youcan eitherselectethernetorwirelessnetworkconnectionaccordingtoyourneed. Note: PleaserefertothechapteronNetworkSetting&Otherconnection fortheconfigurationoftheEthernetandwirelessnetwork connection. 4.2.AccessingtheDeviceSettingontheDevice 4.2.1…

Text truncated - open the document above for the full version.

Cover Letter(s)

     !" #$! %% &"  !'( )*+,  %" -./+0 1+2 " , 0 3(4 " 5, 06 7('473'47 8 7 ('473'47  ,6 9:2*; 8!< =>> ?@ABCDEFGAECH $.0 III3 $ #      *.5 +,J.,  % ;6*.,  $,;,K,  L3' 26% ,66K  % 6* M," $ IL( *MN0<.  90. *.5 +,J.,   /5 ,.  < <0+ 0 "     !" #$!" O0+0M *.5 +,J0K 5, 0+.,-,<.,    !" #.% $ 99* . <.  ,.K M056- , 66 ..0+K +06.,9 . 6,<.,  - + P*, 0. *.5 +,J., " ,<6*%,9 .50 K,9,9 - 66 % <* 0.K +06.,9 . .50K0 ..0+K! 66 <.K <++,0% *. M 5, 0+.,-,<.,    !" #.% $ 99*  *+ M056- K 566 5;0 .50 K 0 0--0<. K *+ / <., ! 0" .50 *%0+K,90%" 50+0M <0+.,- .5. /0 +0  . K*MN0<. .  %0,6 - -0%0+6 M00-,.K" .5. ,< 6*%0K  M00-,.K" *+K*. . 0<.,  '3 - .50 .,$+*9 M*K0 <. - 477" I ! ! ! 7(I! 5,K * .5 +,J.,  ,K ;6,% *.,6 -*+.50+ /+,..0  .,<0 -+ .50 6,<.! ,<0+0 6 Q *+K" 6,0.RK K,9.*+0 1+,.0%  0 Q9 ,.60 90+

Cover Letter(s)

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

External Photos

EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS Port Port

Internal Photos

EXHIBIT C - EUT INTERNAL PHOTOGRAPHS Chip Chip Chip Chip Chip Chip Chip Chip Antenna

RF Exposure Info

China Certification ICT Co., Ltd (Dongguan) Report No.: CR221045835-00B Page 53 of 53 5. RF EXPOSURE EVALUATION 5.1 Applicable Standard FCC §15.247 (i) Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission's guidelines. See §1.1307(b)(1) of this chapter. 5.2 Procedure According to §1.1307(b)(3)(i) (C) Or using Table 1 and the minimum separation distance (R in meters) from the body of a nearby person for the frequency (f in MHz) at which the source operates, the ERP (watts) is no more than the calculated value prescribed for that frequency. For the exemption in Table 1 to apply, R must be at least λ/2π, where λ is the free-space operating wavelength in meters. If the ERP of a single RF source is not easily obtained, then the available maximum time-averaged power may be used in lieu of ERP if the physical dimensions of the radiating structure(s) do not exceed the electrical length of λ/4 or if the antenna gain is less than that of a half-wave dipole (1.64 linear value). Table 1 to § 1.1307(b)(3)(i)(C) - Single RF Sources Subject to Routine Environmental Evaluation RF Source frequency (MHz) Threshold ERP (watts) 0.3-1.34 1,920 R 2 . 1.34-30 3,450 R 2 /f 2 . 30-300 3.83 R 2 . 300-1,500 0.0128 R 2 f. 1,500-100,000 19.2R 2 . 5.3 Measurement Result Radio Frequency (MHz) λ/2 Π (mm) Distance (mm) Exemption ERP (mW) Maximum Conducted Power including Tune-up Tolerance (dBm) Antenna Gain (dBi) ERP MPE- Based Exemption dBm mW WiFi 2412-2462 19.80 200 768 17 3.64 18.49 70.63 Compliant BLE 2402-2480 19.88 200 768 5 3.64 6.49 4.46 Compliant BDR/EDR 2402-2480 19.88 200 768 4 3.64 5.49 3.54 Compliant Note: 1.WiFi and Bluetooth can’t transmit simultaneously. 2. The Value of Maximum Conducted Power including Tune-up Tolerance was declared by the customer. Result: The device compliant the MPE-Based Exemption at 20cm distances. ===== END OF REPORT =====

Test Report

TEST REPORT Applicant: AKUVOX (XIAMEN) NETWORKS CO., LTD. Address: 10/F, No.56 Guanri Road, Software Park II, Xiamen 361009, China FCC ID: 2AHCR-IT88A Product Name: Indoor Monitor Standard(s): 47 CFR Part 15, Subpart C(15.247) ANSI C63.10-2013 KDB 558074 D01 15.247 Meas Guidance v05r02 The above equipment has been tested and found compliant with the requirement of the relative standards by China Certification ICT Co., Ltd (Dongguan) Report Number: CR221045835-00B Date Of Issue: 2022/11/18 Reviewed By: Sun Zhong Title: Manager Test Laboratory: China Certification ICT Co., Ltd (Dongguan) No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China Tel: +86-769-82016888 China Certification ICT Co., Ltd (Dongguan) Report No.: CR221045835-00B Page 2 of 53 Test Facility The Test site used by China Certification ICT Co., Ltd (Dongguan) to collect test data is located on the No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China. The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the FCC Public Access Link (PAL) database, FCC Registration No. : 442868, the FCC Designation No. : CN1314. The lab has been recognized by Innovation, Science and Economic Development Canada to test to Canadian radio equipment requirements, the CAB identifier: CN0123. Declarations China Certification ICT Co., Ltd (Dongguan) is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with a triangle symbol “▲”. Customer model name, addresses, names, trademarks etc. are not considered data. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with an asterisk “★”. China Certification ICT Co., Ltd (Dongguan) Report No.: CR221045835-00B Page 3 of 53 CONTENTS T EST FACILITY .......................................................................................................................................... 2 DECLARATIONS .......................................................................................................................................... 2 1. GENERAL INFORMATION .................................................................................................... 5 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................... 5 1.2 DESCRIPTION OF TEST CONFIGURATION ........................................................................................... 6 1.2.2 Support Equipment List and Details .............................................................................................................. 6 1.2.3 Support Cable List and Details ...................................................................................................................... 6 1.2.4 Block Diagram of Test Setup ......................................................................................................................... 7 1.3 MEASUREMENT UNCERTAINTY .......................................................................................................... 8 2. SUMMARY OF TEST RESULTS ............................................................................................ 9 3. REQUIREMENTS AND TEST PROCEDURES .................................................................. 10 3.1 AC LINE CONDUCTED EMISSIONS .................................................................................................... 10 3.1.1 Applicable Standard ..................................................................................................................................... 10 3.1.2 EUT Setup.................................................................................................................................................... 11 3.1.3 EMI Test Receiver Setup ............................................................................................................................. 11 3.1.4 Test Procedure ............................................................................................................................................. 12 3.1.5 Corrected Amplitude & Margin Calculation ................................................................................................ 12 3.2 RADIATION SPURIOUS EMISSIONS .................................................................................................... 13 3.2.1 Applicable Standard ..................................................................................................................................... 13 3.2.2 EUT Setup.................................................................................................................................................... 13 3.2.3 EMI Test Receiver & Spectrum Analyzer Setup ......................................................................................... 14 3.2.4 Test Procedure ............................................................................................................................................. 14 3.2.5 Corrected Amplitude & Margin Calculation ................................................................................................ 14 3.3 20 DB BANDWIDTH ............................................................................................................................. 1 5 3.3.1 Applicable Standard ..................................................................................................................................... 15 3.3.2 EUT Setup...........................................................................................................…

Text truncated - open the document above for the full version.

Test Report

FreqEffiMaxFreqEffiMaxFreqEffiMax (MHz)(%%)(MHz)(%%)(MHz)(%%) 2400 41.383.64 2410 38.133.19 2420 36.822.84 2430 37.192.67 2440 36.712.44 2450 34.482.2 2460 34.942.4 2470 35.912.6 2480 33.942.52 2490 32.212.48 2500 33.062.74 Reviewed by/Date Remarks 2.4G Tester/dateLyra/20221205Wensen/20221205 Sample sender A kuvox HW Version V1.00 Prototype information Test basisnational standardNumber of samples1 pcs Test itemspassiveTesting equipmentE5071C JIELEI OTA TEST REPORT Record of test results Sample nameIT88ATest conditions22.2°C/ 43 % (dBi) (dBi) (dBi) JIELEI OTA TEST REPORT

Test Setup Photos

EXHIBIT D - TEST SETUP PHOTOGRAPHS Conducted Emissions Front View POE Conducted Emissions Side View POE Radiated Emission Below 1GHz View POE Radiated Emission Above 1GHz View POE

Contact Information

Applicant

Bo Yang
[email protected]086-0591-83057798Fax: 086-0591-83057798

Test Firm

CHINA CERTIFICATION ICT CO., LTD (DONGGUAN)Tanie Ou
[email protected]0086 0769 86858888

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from AKUVOX (XIAMEN) NETWORKS CO., LTD.

Door Phone - FCC ID 2AHCR-S535 - AKUVOX (XIAMEN) NETWORKS CO., LTD.
2AHCR-S535

Door Phone

May 27, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Access Control Terminal - FCC ID 2AHCR-A08K - AKUVOX (XIAMEN) NETWORKS CO., LTD.
2AHCR-A08K

Access Control Terminal

Apr 20, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
HyPanel Lux - FCC ID 2AHCR-RT61 - AKUVOX (XIAMEN) NETWORKS CO., LTD.
2AHCR-RT61

HyPanel Lux

Jul 07, 2024

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Indoor Monitor - FCC ID 2AHCR-S562W - AKUVOX (XIAMEN) NETWORKS CO., LTD.
2AHCR-S562W

Indoor Monitor

Mar 24, 2024

Equipment Class

DTS - Digital Transmission System
Door Phone - FCC ID 2AHCR-R29CV3 - AKUVOX (XIAMEN) NETWORKS CO., LTD.
2AHCR-R29CV3

Door Phone

Jan 04, 2024

Equipment Class

DTS - Digital Transmission System