FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Nomad Goods, Inc./
  3. 2AJYRNM01216285

2AJYRNM01216285Base Station - Hub Edition Global

Nomad Goods, Inc.
Base Station - Hub Edition Global - FCC ID 2AJYRNM01216285 - Nomad Goods, Inc.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Apr 09, 2023
Application Purpose
Original Equipment
Date of Application
Apr 08, 2023
Equipment Note
Base Station - Hub Edition Global
Frequency Range
0.12700000 - 0.12700000
Company
Nomad Goods, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Base Station - Hub Edition | Global Components: AC ADAPTOR 40W (12V / 3.3A, Cable 1.5M/DC 3.5mm) convertible head 1PC, charging base 1PC; 1 Appearance and Specifications: 1.1 Product body picture: 1.2 Specifications: 1.3 Size: 165*107*46mm(charging stand) 1.3.1 Weight: g(including replaceable bull) 1.3.2 Input Plug:DC 3.5mm 1.3.3 Input Voltage:DC 12V 3.33A 1.3.4 Coil Output:Three coils, only one or two mobile phone charging at the same time Charging MODE1 BPP phone: 5W Charging MODE2 BPP phone:5W + 5W Charging MODE3 BPP phone + iPhone: 5W + 7.5W Charging MODE4 iPhone: 7.5W Charging MODE5 iPhone: 7.5W + 7.5W Charging MODE6 any phone + any phone :5W MAX + 5W MAX(When the USBA and USB C ports are loaded, the wireless charge limits the power output) 1.3.5 USB A Output:5W(5V/1A) 1.3.6 USB C Output:PD18W(5V/3A,9V/2A) Wireless charging position for air pods Wireless charging position for phones Wireless charging position for phones 1.3.7 LED indicator: 3 LEDs, Charging OR Charged: Solid White) 1.3.8 Light Sensor: Yes Two gears, according to the environmental brightness dimming LED light 2 Operating instruction: 2.1 Connect the DC plug of the AC ADAPTOR to the charging dock; 2.2 Put the coil position of the mobile phone in alignment with the coil corresponding to the charging board, and the mobile phone will enter the corresponding charging indicator state, indicating that the charging work is in progress. 2.3 The coil on the far left is reserved for charging AirPods, so it's not designed to charge a phone. 2.4 The right coil and middle coil is for charging with Mobile phone 3 Matters needing attention 1.4 Please do not put the product in a humid environment, avoid near the fire source and impact; 1.5 Do not disassemble the product without professional help; 1.6 Do not use a non-compatible switching power supply to charge。 Manufacturer Nomad Goods, Inc. 1187 Coast Village Rd. #638 Suite 1 Santa Barbara, CA 93108, United State FCC WARING This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement: This equipment complies with FCC radiation expo-sure limits set forth for an uncontrolled environment and meets the FCC radio frequency (RF) Exposure Guidelines. When using the product, keep a distance of at least 20cm from the product. RSS Statement (Canada) This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation. Science and Economic Development Cana:la·s licence-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference. including interference that may cause undesired operation of the device. This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 10cm between the radiator and your body. IC: 27646-NM01216285 Declaration de conformite avec le CNR (Canada’s) Cet appareil est conforme au Cahier des charges sur les normes radioelectriques (CNR) pour les appareils utilisables sans licence d'lndustrie Canada. L'utilisation de ce produit est soumise aux oeux conditions suivantes (1) cet appareil ne doit pas entrainer d'interferences; et (2) cet appareil doit accepter toute interference. y compris tes interferences pouvant causer un fonctionnement non souhae. l'emetteur/recepteur exempt de tcence contenu dans le present appareil est conforme aux CNR d'lnnovation. Sciences et Developpement economique Canada applicables aux appareils radio exempts cre t,cence. L·expto,tauon est autorisee aux creux concrmons su,vantes : (1) L'appareil ne doit pas produire de brouillage, (2) rappareil doit accepter tout brouillage radioetectrique subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement. L’appareil est conforme aux valeurs limites d’exposition au rayonnement fixées pour l’ic rs- 102 pour les environnements non contrôlés.Le dispositif doit être installé et fonctionner à une distance d’au moins 10 cm entre le radiateur et votre corps.

Attestation Statements

1/1 US Agent for Service of Process LETTER OF ATTESTATION TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 US Agent for Service of Process: Company Name: Nomad Goods, Inc. FRN: 0025947318 Contact Name: Tane Martin Address: 1187 Coast Village Rd. #638 Suite 1 Santa Barbara, CA 93108, United State Telephone No: (805) 403-7091 Email: [email protected] Applicant: Company name: Nomad Goods, Inc. Product Description: Base Station - Hub Edition | Global Grantee code: 2AJYR FCC ID: 2AJYRNM01216285 Contact Name: Tane Martin Address: 1187 Coast Village Rd. #638 Suite 1 Santa Barbara, CA 93108, United State Telephone No: (805) 403-7091 Email: [email protected] [Nomad Goods, Inc.] certifies that, as of the date of this filing of the application with the TCB, [Nomad Goods, Inc.] is our designated US agent for service of process for the above referenced FCC ID. [Nomad Goods, Inc.] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission related proceeding involving equipment. [Nomad Goods, Inc.] accepts, as of the date of the filing of the application, the obligation of the designated US agent for service of process for the above reference FCC ID. The US Agent for Service of Process is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. The Applicant is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. Date: 2023/04/04 Applicant’s Name: Nomad Goods. Inc. US Agent’s Name: Nomad Goods. Inc. Title: Product Manaqer Title: Product Manaqer Signature Signature

Attestation Statements

Model difference dedaraition To Whom It May Concent We Declared that the model NM01216285 and NM01290285 are the same electronic layout, circuit, construction,except the different c olor. We confirm that all information above is true, and we'I I be responsible for all the consequences. Please contact me if you have any question. Company:Nomad Goods, Inc. Address:1187 C oast Village Rd. #638 Suite 1 Santa Barbara, CA 93108, United State 乙 尸 ~ Signed by: Position :Product Manager Date:2023-03-01

External Photos

Page 1 of 2 FCC ID: 2AJYRNM01216285 IC: 27646-NM01216285 Intertek Testing Services Shanghai Address: Building 86, No. 1198 Qinzhou Road(North), Shanghai 200233, P.R. China Tel: +86 21 61278200 Fax: +86 21 54262353 EUT External Photos EUT Photo EUT Photo Page 2 of 2 FCC ID: 2AJYRNM01216285 IC: 27646-NM01216285 Intertek Testing Services Shanghai Address: Building 86, No. 1198 Qinzhou Road(North), Shanghai 200233, P.R. China Tel: +86 21 61278200 Fax: +86 21 54262353 EUT Photo EUT Photo

ID Label/Location Info

Label Location

Internal Photos

Page 1 of 3 FCC ID: 2AJYRNM01216285 IC: 27646-NM01216285 Intertek Testing Services Shanghai Address: Building 86, No. 1198 Qinzhou Road(North), Shanghai 200233, P.R. China Tel: +86 21 61278200 Fax: +86 21 54262353 EUT INTERNAL PHOTOS EUT Photo EUT Photo Page 2 of 3 FCC ID: 2AJYRNM01216285 IC: 27646-NM01216285 Intertek Testing Services Shanghai Address: Building 86, No. 1198 Qinzhou Road(North), Shanghai 200233, P.R. China Tel: +86 21 61278200 Fax: +86 21 54262353 EUT Photo EUT Photo Wireless charging coil Page 3 of 3 FCC ID: 2AJYRNM01216285 IC: 27646-NM01216285 Intertek Testing Services Shanghai Address: Building 86, No. 1198 Qinzhou Road(North), Shanghai 200233, P.R. China Tel: +86 21 61278200 Fax: +86 21 54262353 EUT Photo

RF Exposure Info

Nomad Goods, Inc. MPE ASSESSMENT REPORT Report Type: FCC MPE assessment report Model: NM01216285, NM01290285 REPORT NUMBER: 230201520SHA-003 ISSUE DATE: April 3, 2023 DOCUMENT CONTROL NUMBER: TTRFFCCMPE-01_V1 © 2018 Intertek Intertek Testing Services Shanghai Building No.86, 1198 Qinzhou Road (North) Caohejing Development Zone Shanghai 200233, China Telephone: 86 21 6127 8200 www.intertek.com TEST REPORT This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TTRFFCCMPE-01_V1© 2018 Intertek Page 2 of 13 Report no.: 230201520SHA-003 Applicant: Nomad Goods, Inc. Address of Applicant: 1187 Coast Village Rd. #638 Santa Barbara, CA 93108, United States Manufacturer: Nomad Goods, Inc. Address of Manufacturer: 1187 Coast Village Rd. #638 Santa Barbara, CA 93108, United States Factory: Zhongshan Zen Factory Ltd. Address of Factory: 6th.Industrial Area, Nanlang Town, Zhongshan City, Guangdong, China FCC ID: 2AJYRNM01216285 SUMMARY: The equipment complies with the requirements according to the following standard(s) or Specification: FCC PART 1 SECTION 1.1310 PREPARED BY: REVIEWED BY: Project Engineer Damon Ding Reviewer Wakeyou Wang Report No.: 230201520SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 3 of 13 Revision History Report No. Version Description Issued Date 230201520SHA-003 Rev. 01 Initial issue of report April 3, 2023 Report No.: 230201520SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 4 of 13 1 GENERAL INFORMATION 1.1 Description of Equipment Under Test (EUT) Product name: Base Station - Hub Edition | Global Type/Model: NM01216285, NM01290285 Description of EUT: The EUT is Base Station - Hub Edition | Global. The additional model NM01290285 is identical with the test model NM01216285 except the model number and color for marketing purpose. Rating: Input:12V/3.3A Category of EUT: Class B EUT type: Table top Floor standing Operating Frequency range: 127 kHz Type of Modulation: ASK Antenna Type: Coil antenna Sample received date: January 30, 2023 Date of test: February 10, 2023 to February 10, 2023 Report No.: 230201520SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 5 of 13 1.2 Description of Test Facility Name: Intertek Testing Services Shanghai Address: Building 86, No. 1198 Qinzhou Road (North), Shanghai 200233, P.R. China Telephone: 86 21 61278200 Telefax: 86 21 54262353 The test facility is recognized, certified, or accredited by these organizations: CNAS Accreditation Lab Registration No. CNAS L0139 FCC Accredited Lab Designation Number: CN0175 IC Registration Lab CAB identifier.: CN0014 VCCI Registration Lab Registration No.: R-14243, G-10845, C-14723, T-12252 A2LA Accreditation Lab Certificate Number: 3309.02 All tests were sub-contracted. Shenzhen UnionTrust Quality and Technology Co., Ltd. Address: Unit D/E of 9/F and 16/F, Block A, Building 6, Baoneng Science and Technology Park, Longhua District, Shenzhen, China 518109 Telephone: +86 (0) 755 2823 0888 Fax: +86 (0) 755 2823 0886 All tests were sub-contracted at Shenzhen UnionTrust Quality and Technology Co., Ltd, and conducted by Kieron Luo Reviewed and approved by Wakeyou Wang from Intertek Testing Services Shanghai. The test facility is recognized, certified, or accredited by the following organizations: CNAS-Lab Code: L9069 The measuring equipment utilized to perform the tests documented in this report has been calibrated once a year or in accordance with the manufacturer's recommendations, and is traceable under the ISO/IEC/EN 17025 to international or national standards. Equipment has been calibrated by accredited calibration laboratories. IC-Registration No.: 21600-1 Report No.: 230201520SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 6 of 13 The 3m Semi-anechoic chamber of Shenzhen UnionTrust Quality and Technology Co., Ltd. has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 21600-1. A2LA-Lab Certificate No.: 4312.01 Shenzhen UnionTrust Quality and Technology Co., Ltd. has been accredited by A2LA for technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025: 2005 General Requirements for the Competence of Testing and Calibration Laboratories and any additional program requirements in the identified field of testing. FCC Accredited Lab. Designation Number: CN1194 Test Firm Registration Number: 259480 Report No.: 230201520SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 7 of 13 2 TEST SPECIFICATIONS 2.1 Standards or specification FCC PART 1 SECTION 1.1310 KDB 680106 D01 RF Exposure Wireless Charging App v03r01 2.2 Mode of operation during the test Within this test report, EUT was tested under all modes and tested under its rating voltage and frequency. Other voltage and frequency are specified if used. The test mode is as follows: Test Mode 1: Wireless charging mode with phone (7.5W) Test Mode 2: Wireless charging mode with phone (7.5W) + Wireless charging mode with phone (7.5W) Test Mode 3: Wireless charging mode with phone (7.5W) + Wireless charging mode with Air Pods(5W) Test Mode 4: Wireless charging mode with Air…

Text truncated - open the document above for the full version.

Test Report

Nomad Goods, Inc. TEST REPORT Report Type: FCC Part 15C Model: NM01216285, NM01290285 REPORT NUMBER: 230201520SHA-002 ISSUE DATE: April 3, 2023 DOCUMENT CONTROL NUMBER: TTRF15c_V1 © 2018 Intertek Intertek Testing Services Shanghai Building No.86, 1198 Qinzhou Road (North) Caohejing Development Zone Shanghai 200233, China Telephone: 86 21 6127 8200 www.intertek.com TEST REPORT This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TTRF15b_V1 © 2018 Intertek Page 2 of 25 Report no.: 230201520SHA-002 Applicant: Nomad Goods, Inc. Address of Applicant: 1187 Coast Village Rd. #638 Santa Barbara, CA 93108, United States Manufacturer: Nomad Goods, Inc. Address of Manufacturer: 1187 Coast Village Rd. #638 Santa Barbara, CA 93108, United States Factory: Zhongshan Zen Factory Ltd. Address of Factory: 6th.Industrial Area, Nanlang Town, Zhongshan City, Guangdong, China FCC ID: 2AJYRNM01216285 SUMMARY: The equipment complies with the requirements according to the following standard(s) or Specification: 47CFR Part 15 (2019): Radio Frequency Devices (Subpart C) ANSI C63.10 (2013): American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices PREPARED BY: REVIEWED BY: Project Engineer Damon Ding Reviewer Wakeyou Wang Report No.: 230201520SHA-002 TEST REPORT TTRF15b_V1 © 2018 Intertek Page 3 of 25 Content REVISION HISTORY................................................................................................................................................ 4 MEASUREMENT RESULT SUMMARY ..................................................................................................................... 5 1 GENERAL INFORMATION ............................................................................................................................. 6 1.1 DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ..................................................................................................... 6 1.2 DESCRIPTION OF TEST FACILITY .............................................................................................................................. 7 2 TEST SPECIFICATIONS ................................................................................................................................... 9 2.1 STANDARDS OR SPECIFICATION ............................................................................................................................... 9 2.2 MODE OF OPERATION DURING THE TEST ................................................................................................................... 9 2.3 TEST SOFTWARE LIST .......................................................................................................................................... 10 2.4 TEST PERIPHERALS LIST ....................................................................................................................................... 10 2.5 SUPPORT CABLE LIST .......................................................................................................................................... 10 2.6 TEST ENVIRONMENT CONDITION: .......................................................................................................................... 10 2.7 INSTRUMENT LIST .............................................................................................................................................. 11 2.8 MEASUREMENT UNCERTAINTY ............................................................................................................................. 11 3 RADIATED EMISSIONS ............................................................................................................................... 12 3.1 LIMIT .............................................................................................................................................................. 12 3.1.1 the emissions from an intentional radiator shall not exceed the field strength levels specified in the following table .................................................................................................................................................. 12 3.2 BLOCK DIAGRAM AND TEST SET UP ........................................................................................................................ 13 3.3 MEASUREMENT PROCEDURE ............................................................................................................................... 14 3.4 TEST RESULTS OF RADIATED EMISSIONS ................................................................................................................. 15 4 POWER LINE CONDUCTED EMISSION ......................................................................................................... 18 4.1 LIMIT .............................................................................................................................................................. 18 4.1.1 Limits for conducted disturbance voltage at the mains ports of class B device .................................. 18 4.2 BLOCK DIAGRAM AND TEST SET UP ............................................…

Text truncated - open the document above for the full version.

Test Report

Manufacturer:Zhongshan Zen Factory Ltd. Address:6th.Industrial Area, Nanlang Town, Zhongshan City, Guangdong, China Type / model:AC310

Test Setup Photos

Page 1 of 2 FCC ID: 2AJYRNM01216285 Intertek Testing Services Shanghai Address: Building 86, No. 1198 Qinzhou Road(North), Shanghai 200233, P.R. China Tel: +86 21 61278200 Fax: +86 21 54262353 APPENDIX 1 PHOTOS OF TEST SETUP Radiated emission Test Setup (Below 30MHz) Radiated emission Test Setup (30 MHz~1 GHz) Page 2 of 2 FCC ID: 2AJYRNM01216285 Intertek Testing Services Shanghai Address: Building 86, No. 1198 Qinzhou Road(North), Shanghai 200233, P.R. China Tel: +86 21 61278200 Fax: +86 21 54262353 Conducted emission

Test Setup Photos

Page 1 of 3 FCC ID: 2AJYRNM01216285 Intertek Testing Services Shanghai Address: Building 86, No. 1198 Qinzhou Road(North), Shanghai 200233, P.R. China Tel: +86 21 61278200 Fax: +86 21 54262353 APPENDIX 1 PHOTOS OF TEST SETUP E-Field Strength and H-Field Strength Position A (15cm) E-Field Strength and H-Field Strength Position B (15cm) Page 2 of 3 FCC ID: 2AJYRNM01216285 Intertek Testing Services Shanghai Address: Building 86, No. 1198 Qinzhou Road(North), Shanghai 200233, P.R. China Tel: +86 21 61278200 Fax: +86 21 54262353 E-Field Strength and H-Field Strength Position C (15cm) E-Field Strength and H-Field Strength Position D (15cm) Page 3 of 3 FCC ID: 2AJYRNM01216285 Intertek Testing Services Shanghai Address: Building 86, No. 1198 Qinzhou Road(North), Shanghai 200233, P.R. China Tel: +86 21 61278200 Fax: +86 21 54262353 E-Field Strength and H-Field Strength Position E (20cm)

Contact Information

Applicant

Tane Martin(Sr. Product Manager)
[email protected]+1(805)403-7091Fax: +1(415)484-7699

Technical Contact

Shenzhen UnionTrust Quality and Technology Co., LtBilly Li
[email protected]0755-28230888

Shenzhen · China

Non-Technical Contact

Shenzhen UnionTrust Quality and Technology Co., LtBilly Li
[email protected]0755-28230888

Test Firm

Shenzhen UnionTrust Quality and Technology Co., LtGeorge Luo
[email protected]+86-755-28230888

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.127 MHz - 0.127 MHz-
Confidentiality
Long Term
Grant Notes
The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Other Applications from Nomad Goods, Inc.

Base One Max (3-in-1) with MagSafe - FCC ID 2AJYRNM01232285 - Nomad Goods, Inc.
2AJYRNM01232285

Base One Max (3-in-1) with MagSafe

Aug 26, 2023

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Charge Mount - FCC ID 2AJYRNM01091585 - Nomad Goods, Inc.
2AJYRNM01091585

Charge Mount

Feb 05, 2023

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Base One Max with MagSafe - FCC ID 2AJYRNM01172185 - Nomad Goods, Inc.
2AJYRNM01172185

Base One Max with MagSafe

Aug 28, 2022

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Base Station Compact - FCC ID 2AJYRNM01838685 - Nomad Goods, Inc.
2AJYRNM01838685

Base Station Compact

Jan 18, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Base Station Hub Edition - FCC ID 2AJYRNM30011A30 - Nomad Goods, Inc.
2AJYRNM30011A30

Base Station Hub Edition

Aug 18, 2020

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz