2AMYQ-2020X580Robtic Vaccum Cleaner

Shenzhen Hua Xin Information Technology Co., Ltd
Robtic Vaccum Cleaner - FCC ID 2AMYQ-2020X580 - Shenzhen Hua Xin Information Technology Co., Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jun 26, 2020
Application Purpose
Original Equipment
Date of Application
Jun 23, 2020
Equipment Note
Robtic Vaccum Cleaner
Frequency Range
2412.00000000 - 2462.00000000
Company
Shenzhen Hua Xin Information Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ROBOTIC VACUUM CLEANER USER MANUAL (Before using this product,please read the safety instructions below and follow all the routine safety precautions) 1. Wi-Fi Setup Instru ctions 7. Pro duc t hazardous material labeling Content 3.1 Name of Parts 3.2 Products Specifications 3.3 Product feature 4.1 Attention 4.2 Remote Controller Instructions 4.3 Operating Instructions 5.1 Side B ru sh Cleaning and Repl acement 5.2 Cleaning of Dust Box and Filter 5.3 Maintenance of Water Tank Components 5.4 Maintenance of Rollin g Bru sh Components 5.5 Maintenance of Other Components 6.1 Common F aults 6.2 Repl aceable Modules 6. Com mon Faults 4. Instruc tions for Use 5. Pro duc t Maintenan ce 2.Safety Instructi ons 3.Produ ct C omponen ts 1 Wi-Fi Setup Instructions Wi-Fi Setup Instructions To perfefct the products, we keep the right of updating the APP and the software. The final interface is subject to the actual products, thank you. Scan the QR code on the device or the QR code on the right side,or manual input the QR code/Barcode to confirm the device model,turn on the “Power switch” by following APP instructions and go to the next step. Scan the QR code in Figure 1 to download and install “WeBack” APP, or download and install from other APP stores. Figure 1 Open App, directly log in if you have a “WeBack” account; if not, you can select “New User” to sign up, and click on " " after login. Figure 2 Figure 3 Figure 4 Forget Password 2 Wi-Fi Setup Instructions To perfefct the products, we keep the right of updating the APP and the software. The final interface is subject to the actual products, thank you. Wi-Fi Setup Instructions On the device management page, click the button" " (Figure 8),in the upper right corner of the device to enter the settings page(Figure 9). Figure 5 When you see the APP enter interface Figure 5,you can start using APP to control your ROBOT.Tap the device to enter the main interface of APP (Figure 5), from this interface you can choose different cleaning modes, also to check the cleaning process/status. Tap the “more” Key(Figure 6) to enter the multi-functional panel (Figure 7). Figure 6 Figure 7 Figure 8 Figure 9 Safety Instruction 3 Before using this product,please read the safety instructions below and follow all the routine safety precautions. Safety considerations of Main Body and Accessories Please read the instructions carefully and keep them for future reference. Any operation that does not conform to the instructions may cause damage to the product. Warning 01.Do not disassemble,repair or refit the product without authorization;otherwise it may damage the product or pose a hazard. 02.Do not use the product in an environment with risk of fire or explosion. 03.This product can only use the original power adapter;otherwise the product may be damaged or catch on fire. 04.Do not stand or sit on this product;doing so could damage the product or cause it to fall over. 05.When the metal part of the power plug is dusty,please wipe it with a dry cloth. 06.The power adapter is applied to a 100-240V AC voltage.Please plug into the socket properly and keep away from children. 07.Do not wash or soak the main body and electronic accessories in the water;otherwise the product may be damaged by a short circuit. 08.Do not damage,load weight on,heat,pull,or bend it. 09.During cleaning,please pay attention to the safety of toddlers and elders at home to avoid injury. (Please pay special attention to toddlers). 10.This product is for home use.Please do not use it outdoors. 11.Do not allow metal and conductive materials to come in contact with the battery;doing so may cause a short circuit. Attentions 01.Do not touch the product with wet hands;doing so may cause an electric shock. 02.Please do not place the product in places where it could easily fall,such as tables,chairs,high platforms in room,etc. 03.The product has a sophisticated design and should be protected from long-term exposure to sunlight. 04.Please do not use the product in humid environments,such as bath-rooms. 05.Please do not place the product near cigarette butts,lighters or other open fires. 06.Please clean the product after finishing charging. 07.Please turn off the power switch on the side of the robot when the product is out of service for a long time. 08. Please check carefully to see if the power adapter is connected to the socket prior to use,to avoid damage to the robot. 4 Safety Instruction 09.Before using the product,please remove all vulerable items on the floor,such as glass, lamps,and items such as wires and curtains that may entangle with the side brush and suction passages. 10.When the dust box is full,please empty it before using again. 11.Please do not use the robot to clean the construction waste. 12.The operating temperature of the product ranges from 0 degree Celsius to 40 degrees Celsius;please do not use it in a high temperature environment. 13.Before the product is scrapped,please remove the battery from the robot.When you remove the battery,please ensure that the product is not connected to a power supply. Please recycle the battery safety or environmental protection. Safety Considerationsfr Rechargeable Battery Danger 01.Always use a dedicated battery adapter to avoid leakage,heating or rupture. 02.Do not short-circuit the battery or remove the battery;doing so may cause leakage, heating or rupture. 03.Do not transport or preserve with necklaces,hairpins,and other metal objects;doing so may lead to short circuit,resulting in leakage,heating or rupture. 04.Do not burn or heat the battery;doing so may cause leakage,heating or rupture. Attention 01. If abnormal overheating is discovered during charging,stop using it immediately to avoid leakage,heating or rupture. 02. To prolong the service life of the battery,please remove the battery and place it in a cool, dry environment if it is out of service for a long time;this will avoid leakage,heating or rupture. 03. Do not soak in water or let it come into…

Text truncated - open the document above for the full version.

Attestation Statements

Page1of1 Declarationonmodeldifference We,ShenzhenHuaXinInformationTechnologyCo.,Ltd.theundersigned herebyconfirmthatthesemodelsareidentical,andallmodelshavethesame RFmoduleandAntenna,exceptcolorandmodelNo.fortradingpurpose. ProductnameTradenameFCCIDINPUTModelNo. RobticVaccum Cleaner N/A2AMYQ-2020X580 AC100-240V50/60HZ 19V/0.6A X580、X583、 X586、X580r、 simum6、 simum7、 simum8、 simum9、M1、 N1、S3、V6 Confirmedby: Client’ssignature: Client’sname/title:Supingzhan/Engineer Date2020-06-20

Cover Letter(s)

C5266091_X8_Ed.1 1/1 LetterofAuthorization ShenzhenHuaXinInformationTechnologyCo.,Ltd. Company:ShenzhenHuaXinInformationTechnologyCo.,Ltd. Address:SectionA,10/F,Block1,No.7IndustrialPark,Yulu Community,Yutang,GuangmingNew District,Shenzhen,China ProductName:RobticVaccumCleaner ModelNumber:X580 、 X583 、 X586 、 X580r 、 simum6 、 simum7 、 simum8、simum9、M1、N1、S3、V6 FCCIdentifier:2AMYQ-2020X580 WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:SupingzhanDate:2020-06-20 Title:Engineer Signatureofapplicant:

Cover Letter(s)

C5266091_X10_Ed.1 1/1 ShenzhenHuaXinInformationTechnologyCo.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:2020-06-20 Subject:RequestforConfidentiality FCCID:2AMYQ-2020X580 ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo BlockDiagram Schematics TestReportNoNo TestSetupPhotosNo User’sManual InternalPhotos PartsList/TuneUp RFExposureInfo OperationalDescription CoverLetter(s)NoNo SDRSoftware/SecurityInfoNo Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. Sincerely, Signature: Name:Supingzhan Title:Engineer

Internal Photos

FCC ID:2AMYQ-2020X580 Antenna AP6210

RF Exposure Info

ReportNo.:PTC20052502402E-FC02 Page 1 of 7 FCCTESTREPORT FCCID:2AMYQ-2020X580 Product: RobticVaccumCleaner ModelName: X580 Additionalmodel : X583、X586、X580r、simum6、simum7、simum8、 simum9、M1、N1、S3、V6 Brand N/A ReportNo.: PTC20052502402E-FC02 Preparedfor ShenzhenHuaXinInformationTechnologyCo.,Ltd. SectionA,10/F,Block1,No.7IndustrialPark,YuluCommunity,Yutang,GuangmingNew District,Shenzhen,China Preparedby PreciseTesting&CertificationCo.,Ltd Building1,No.6,TongxinRoad,DongchengStreet,Dongguan,Guangdong,China ReportNo.:PTC20052502402E-FC02 Page 2 of 7 TESTRESULTCERTIFICATION Applicant’sname: ShenzhenHuaXinInformationTechnologyCo.,Ltd. Address: SectionA,10/F,Block1,No.7IndustrialPark,Yulu Community,Yutang,GuangmingNewDistrict,Shenzhen,China Manufacture'sname: ShenzhenHuaXinInformationTechnologyCo.,Ltd. Address: SectionA,10/F,Block1,No.7IndustrialPark,Yulu Community,Yutang,GuangmingNewDistrict,Shenzhen,China Productname:RobticVaccumCleaner Modelname: X580 Additionalmode: X583 、 X586 、 X580r 、 simum6 、 simum7 、 simum8 、 simum9 、 M1 、 N1 、 S3 、 V6 TestprocedureKDB447498D01GeneralRFExposureGuidancev05 TestDate: May28,2020toJun11,2020 DateofIssue: Jun11,2020 TestResult:Pass ThisdevicedescribedabovehasbeentestedbyPTS,andthetestresultsshowthatthe equipmentundertest(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlyto thetestedsampleidentifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofPTS,thisdocument maybealteredorrevisedbyPTS,personalonly,andshallbenotedintherevisionofthedocument. TestEngineer: LeoYang/Engineer TechnicalManager: ChrisDu/Manager ReportNo.:PTC20052502402E-FC02 Page 3 of 7 Contents Page 2TESTSUMMARY................................................................................................................................................4 3GENERALINFORMATION...............................................................................................................................5 3.1GENERALDESCRIPTIONOFE.U.T..........................................................................................................5 4RFEXPOSURE...................................................................................................................................................6 4.1REQUIREMENTS........................................................................................................................................6 4.2THEPROCEDURES/LIMIT.........................................................................................................................6 4.3MPECALCULATIONMETHOD..................................................................................................................7 4.4TESTRESULT............................................................................................................................................7 ReportNo.:PTC20052502402E-FC02 Page 4 of 7 2TestSummary TestItemsTestRequirementResult MaximumPermissibleExposure (ExposureofHumanstoRFFields) 1.1307(b)(1)PASS Remark: N/A:NotApplicable ReportNo.:PTC20052502402E-FC02 Page 5 of 7 3GeneralInformation 3.1GeneralDescriptionofE.U.T. ProductName : RobticVaccumCleaner ModelName : X580 Additionalmodel X583、X586、X580r、simum6、simum7、simum8、simum9、M1、 N1、S3、V6 ModelDescription : (X580isthemaintestmodel,othermodelsandmaintestmodelshavedifferent appearancecolors,othersarethesame) BluetoothVersion :N/A Specification : 802.11b/g/nHT20/40 Operatingfrequency : 2412-2462MHzfor802.11b/g;/n(HT20) 2422-2452MHzfor802.11n(HT40); TypeofModulation : DSSSwithDBPSK/DQPSK/CCKfor802.11b; OFDMwithBPSK/QPSK/16QAM/64QAMfor802.11g/n; Antennainstallation: :PCBantenna AntennaGain: :3dbi Powersupply :AC120V/60Hz Adapter : AC100-240V50/60HZ19V/0.6A(14.4V2500mAh,battery) ReportNo.:PTC20052502402E-FC02 Page 6 of 7 4RFExposure TestRequirement :FCCPart1.1307(b)(1) EvaluationMethod :FCCPart2.1091 4.1Requirements Systemsoperatingundertheprovisionsofthissectionshallbeoperatedinamannerthatensuresthat thepublicisnotexposedtoradiofrequencyenergylevelsinexcesslimitformaximumpermissible exposure.Inaccordancewith47CFRFCCPart2SubpartJ,section2.1091thisdevicehasbeen definedasamobiledevicewherebyadistanceof0.2mnormallycanbemaintainedbetweentheuser andthedevice. 4.2Theprocedures/limit (A)LimitsforOccupational/ControlledExposure FrequencyRangeElectricFieldMagneticFieldPowerDensity(S)AveragingTime 0.3-3.06141.63(100)*6 3.0-301842/f4.89/f(900/f)*6 30-30061.40.1631.06 300-1500F/3006 1500-100,00056 (B)LimitsforGeneralPopulation/UncontrolledExposure FrequencyRangeElectricFieldMagneticFieldPowerDensity(S)AveragingTime 0.3-1.346141.63(100)*30 1.34-30824/f2.19/f(180/f)*30 30-30027.50.0730.230 300-1500F/150030 1500-100,0001.030 Note:f=frequencyinMHz;*Plane-waveequivalentpowerdensity ReportNo.:PTC20052502402E-FC02 Page 7 of 7 4.3MPECalculationMethod E(V/m) = d GP30 PowerDensity:Pd(W/m²) = 377 2 E E = Electricfield(V/m) P=PeakRFoutputpower(W) G = EUTAntennanumericgain(numeric) d=Separationdistancebetweenradiatorandhumanbody(m) Theformulacanbechangedto Pd = 2 377 30 d GP   FromthepeakEUTRFoutputpower,theminimummobileseparationdistance,d=0.2m,aswellas thegainoftheusedantenna,theRFpowerdensitycanbeobtained 4.4TestResult Item Antenna Gain (numeric) Max.Peak OutputPower (dBm) PeakOutput Power(mW) PowerDensity (mW/cm2) LimitofPower Density (mW/cm2) Result WIFI218.0663.970.02541Pass ******THEENDREPORT******

Test Report

Page 1 of 67 FCCTESTREPORT FCCID:2AMYQ-2020X580 Product: RobticVaccumCleaner ModelName: X580 Additionalmode: X583、X586、X580r、simum6、simum7、simum8、simum9、M1、 N1、S3、V6 Brand N/A ReportNo.: PTC20052502402E-FC01 Preparedfor ShenzhenHuaXinInformationTechnologyCo.,Ltd. SectionA,10/F,Block1,No.7IndustrialPark,YuluCommunity,Yutang,GuangmingNew District,Shenzhen,China Preparedby PreciseTesting&CertificationCo.,Ltd Building1,No.6,TongxinRoad,DongchengStreet,Dongguan,Guangdong,China ReportNo.:PTC20052502402E-FC01 Page 2 of 67 1TESTRESULTCERTIFICATION Applicant’sname: ShenzhenHuaXinInformationTechnologyCo.,Ltd. Address: SectionA,10/F,Block1,No.7IndustrialPark,Yulu Community,Yutang,GuangmingNewDistrict,Shenzhen,China Manufacture's name : ShenzhenHuaXinInformationTechnologyCo.,Ltd. Address : SectionA,10/F,Block1,No.7IndustrialPark,Yulu Community,Yutang,GuangmingNewDistrict,Shenzhen,China Productname : RobticVaccumCleaner Modelname :X580 Additionalmode: X583、X586、X580r、simum6、simum7、simum8、simum9、M1、N1、S3、 V6 Standards : FCCCFR47Part15Section15.247 Testprocedure : ANSIC63.10:2013 TestDate: May28,2020toJun11,2020 DateofIssue: Jun11,2020 TestResult:Pass ThisdevicedescribedabovehasbeentestedbyPTC,andthetestresultsshowthattheequipmentunder test(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofPTC,thisdocumentmaybe alteredorrevisedbyPTC,personalonly,andshallbenotedintherevisionofthedocument. TestEngineer: LeoYang/Engineer TechnicalManager: ChrisDu/Manager ReportNo.:PTC20052502402E-FC01 Page 3 of 67 Contents Page 1TESTRESULTCERTIFICATION................................................................................................................................2 2TESTSUMMARY...........................................................................................................................................................5 3GENERALINFORMATION..........................................................................................................................................6 3.1GENERALDESCRIPTIONOFE.U.T.....................................................................................................................6 3.2CHANNELLIST......................................................................................................................................................7 3.3TESTSITE...........................................................................................................................................................10 4EQUIPMENTDURINGTEST.....................................................................................................................................11 4.1EQUIPMENTSLIST..............................................................................................................................................11 4.2MEASUREMENTUNCERTAINTY..........................................................................................................................13 4.3DESCRIPTIONOFSUPPORTUNITS....................................................................................................................14 5CONDUCTEDEMISSION...........................................................................................................................................15 5.1E.U.T.OPERATION............................................................................................................................................15 5.2EUTSETUP........................................................................................................................................................15 5.3TESTSET-UP(BLOCKDIAGRAMOFCONFIGURATION)..................................................................................16 5.4MEASUREMENTPROCEDURE............................................................................................................................16 5.5CONDUCTEDEMISSIONLIMIT............................................................................................................................16 5.6MEASUREMENTDESCRIPTION...........................................................................................................................16 5.7CONDUCTEDEMISSIONTESTRESULT..............................................................................................................16 6RADIATEDSPURIOUSEMISSIONS.......................................................................................................................19 6.1EUTOPERATION...............................................................................................................................................19 6.2TESTSETUP.......................................................................................................................................................20 6.3SPECTRUMANALYZERSETUP...........................................................................................................................21 6.4TESTPROCEDURE.............................................................................................................................................22 6.5SUMMARYOFTESTRESULTS...........................................................................................................................23 7CONDUCTEDSPURIOUSEMISSION.....................................................................................................................30 7.1TESTPROCEDURE.............................................................................................................................................30 7.2TESTRESULT.....................................................................................................................................................30 8BANDEDGEMEASUREMENT................................................................................................................................33 ReportNo.:PTC…

Text truncated - open the document above for the full version.

Test Setup Photos

Conducted Emissions Radiated Spurious Emissions From 30MHz-1000MHz Model: X580 TestfrequencyfromAbove1GHz

Contact Information

Applicant

Suping Zhan
[email protected]+86-13516823366Fax: 0086-755-26665266

Technical Contact

Shenzhen Hua Xin Information Technology Co., LtdSuping zhan
[email protected]13516823366

Shenzhen · China

Test Firm

Precise Testing & Certification Co., LTD.Chris Du
[email protected]+86-769-38808222

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz64.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Other Applications from Shenzhen Hua Xin Information Technology Co., Ltd

Robotic vacuum cleaner - FCC ID 2AMYQ-2026G300 - Shenzhen Hua Xin Information Technology Co., Ltd
2AMYQ-2026G300

Robotic vacuum cleaner

Apr 01, 2026

Equipment Class

DTS - Digital Transmission System
Robotic vacuum cleaner - FCC ID 2AMYQ-2025G580 - Shenzhen Hua Xin Information Technology Co., Ltd
2AMYQ-2025G580

Robotic vacuum cleaner

Dec 12, 2025

Equipment Class

DTS - Digital Transmission System
Robotic Vacuum Cleaner - FCC ID 2AMYQ-202012GD580 - Shenzhen Hua Xin Information Technology Co., Ltd
2AMYQ-202012GD580

Robotic Vacuum Cleaner

Jan 28, 2021

Equipment Class

DTS - Digital Transmission System
Robotic Vacuum Cleaner - FCC ID 2AMYQ-202012GD500 - Shenzhen Hua Xin Information Technology Co., Ltd
2AMYQ-202012GD500

Robotic Vacuum Cleaner

Jan 25, 2021

Equipment Class

DTS - Digital Transmission System
Robotic Vacuum Cleaner - FCC ID 2AMYQ-202012K100 - Shenzhen Hua Xin Information Technology Co., Ltd
2AMYQ-202012K100

Robotic Vacuum Cleaner

Jan 02, 2021

Equipment Class

DTS - Digital Transmission System