FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD/
  3. 2ANMU-WP21

2ANMU-WP21Smart Phone

SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD
Smart Phone - FCC ID 2ANMU-WP21 - SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Nov 19, 2022
Application Purpose
Original Equipment
Date of Application
Nov 19, 2022
Equipment Note
Smart Phone
Frequency Range
5180.00000000 - 5240.00000000
Company
SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD
Country
China

Documents & Files

Select a file to view

Users Manual

โ†—

Cover Letter(s)

โ†—
โ†—
โ†—
โ†—
โ†—
โ†—

External Photos

โ†—

ID Label/Location Info

โ†—

Internal Photos

โ†—

RF Exposure Info

โ†—
โ†—
โ†—

Test Report

โ†—
โ†—

Test Setup Photos

โ†—
โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

WP21 WP21 Sound hole Type-c MIC Light sensor Receiver Front camera Quick Charger TYPE-C Manual Warranty Card Touch screen 66 Vent holes Sound hole WP21 9800 Rear main camera Night vision Secondary display Macro camera SIM card SOS Infrared Sensor Volume + Volume - flash Fingerprint pluspower button camera key 2 SIM2 Card SIM1 Card How to insert the card How to boot How to send SMS๏ผŒMMS Language switching settings SAR Safety - In order to ensure safety during use of the product , you must strictly abide by the following rules oukitel.com oukitel.com FCC ID : 2ANMU-WP21 9 10 Schallloch Lichtsensor Berรผhrungssensitiver Bildschirm Typ-c MIC Vordere Kamera Vordere Kamera Schallloch Entlรผftungslรถcher

Cover Letter(s)

FCC_Software Configuration Control Declaration Rev1.1 SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD FCC Software Configuration Control Declaration Date: November 16, 2022 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Attn: OET Dept. Product/ Model Number: Smart Phone / WP21, WP21 Pro, WP21 S Regarding FCC Country Code Selection guidelines identified in KDB 594280D01v02r01. โ€œAll applications for equipment authorization for transmitters that can have radio parameters, or other technical parameters, reported to the Commission set by software must have an attestation indicating that no third party will have software, or configuration control, to program the device out of compliance of the technical rules under which it has been certified.โ€ We declare that no third party will have software, or configuration control, to program the device out of compliance of the technical rules under which it has been certified. Name: Gaolei Yan Date: 2022/11/16 Title: Manager Signature of applicant

Cover Letter(s)

SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Agent Authorization Company: SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Address: A2 2F BUILDING ENET NEW INDUSTRIAL PARK, DAFU INDUSTRIAL ZONE, GUANLAN, LONGHUA SHENZHEN, 518XXX China Product Name: Smart Phone Model Number(s): WP21, WP21 Pro, WP21 S Product Description: Smart Phone We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2022/11/16 Name: Gaolei Yan Title: manager Company: SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD

Cover Letter(s)

SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Family models difference declaration Product Name: Smart Phone Trade Name: OUKITEL Model Name: WP21, WP21 Pro, WP21 S Difference declaration: All the model are the same circuit and RF module, except the model name. Regards, Signature Name: Gaolei Yan Date: 2022-11-16

Cover Letter(s)

SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2022/11/16 Subject; Request for Confidentiality FCC ID:2ANMU-WP21 To Whom It May Concern, Pursuant to the provisions of the Commissionโ€™s rules Title 47 Sections ยง0.457 and ยง0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List/BOM Operational Description Tune-up Procedure FCC_Software_Security_Requirements_for_UNII_devices In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR ยง2.803 and the importation rules in Title 47 CFR ยง2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuantto KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Gaolei Yan Title: Manager Email:[email protected]

Cover Letter(s)

SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Letter of Authorization European Union Company Name: SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Address: 202, Building A2, Silicon Valley Power Intelligent Terminal Industrial Park, No. 20, Dafu Industrial Zone, Kukeng Community, Guanlan Street, Longhua District, Shenzhen, China Product Name: Smart Phone Trade Mark: OUKITEL Model Number(s): WP21, WP21 Pro, WP21 S We authorize MiCOM Labs Inc, 575 Boulder Court, Pleasanton, CA 94566, USA, to act on our behalf on all matters concerning the above named equipment. MiCOM Labs is authorized to act on our behalf and take action on the application. This shall include the following: ๏‚ท Testing ๏‚ท Notify Body Opinion (includes complete product documentation package, including Confidential information) and procedures. ๏‚ท Payment of approval fees We declare that MiCOM Labs Inc, 575 Boulder Court, Pleasanton, CA 94566, USA, is allowed to forward all information related to the approval project to the applied notified body and to the notification entities and to discuss any issues concerning the application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as of our own. ______________________________ Signature Name: Gao Lei Yan Date: 2022/11/15 Title: Manager Company: SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Email: [email protected] Phone: (+86) 18676796436

Cover Letter(s)

SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD A2 2F BUILDING ENET NEW INDUSTRIAL PARK, DAFU INDUSTRIAL ZONE, GUANLAN, LONGHUA SHENZHEN, 518XXX China Date: Nov 16, 2022 FCC ID: 2ANMU-WP21 Model Number: WP21, WP21 Pro, WP21 S To: Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21048 To Whom It May Concern, We, SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD, declare that this EUT (FCC ID: 2ANMU- WP21) will conduct FCC compliance testing, the SDOC part recognized test lab(Shenzhen NTEK Testing Technology Co., Ltd.( ShenZhen Lab.). 1/F, Building E, Fenda Science Park, Sanwei Community,Xixiang Street Baoโ€™an District, Shenzhen 518126 P.R. China) Please contact me if you have any question. Sincerely, (Signed) Name / Title: Gaolei Yan / Manager Company: SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Address: A2 2F BUILDING ENET NEW INDUSTRIAL PARK, DAFU INDUSTRIAL ZONE, GUANLAN, LONGHUA SHENZHEN, 518XXX China Phone: 0755-61156588 Fax: 0755-61156588 Email: [email protected]

External Photos

ATTACHMENT PHOTOGRAPHS OF EUT Photo 1 Photo 2 Photo 3 Photo 4 Photo 5 Photo 6 Photo 7 Photo 8 Photo 9 Photo 10

ID Label/Location Info

SIZE:40*30mm

Internal Photos

ATTACHMENT PHOTOGRAPHS OF EUT Photo 1 Photo 2 Photo 3 Photo 4 Photo 5 Photo 6 Photo 7 Photo 8 Photo 9 Photo 10 Photo 11 Photo 12 Photo 13 Photo 14 GSM/WCDMA/LTE Main ANT Photo 15 Photo 16 LTE AUX ANT BT/WIFI ANT Photo 17 NFC ANT

RF Exposure Info

Page 1 of 223 Report No.: S22092204106001 FCC SAR EVALUATION REPORT In accordance with the requirements of FCC 47 CFR Part 2(2.1093), ANSI/IEEE C95.1-1992 and IEEE Std 1528-2013 Product Name๏ผš Smart Phone Brand Name๏ผš OUKITEL Model Name๏ผš WP21 Family Model๏ผš WP21 Pro, WP21 S Report No.๏ผš S22092204106001 FCC ID๏ผš 2ANMU-WP21 Prepared for SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD A2 2F BUILDING ENET NEW INDUSTRIAL PARK, DAFU INDUSTRIAL ZONE, GUANLAN, LONGHUA SHENZHEN, 518XXX China Prepared by Shenzhen NTEK Testing Technology Co., Ltd. 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street, Bao'an District, Shenzhen 518126 P.R.China. Tel. 400-800-6106, 0755-2320 0050, 0755-2320 0090 Website: http://www.ntek.org.cn Page 2 of 223 Report No.: S22092204106001 TEST RESULT CERTIFICATION Applicantโ€™s name ................. : SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Address .................................. : A2 2F BUILDING ENET NEW INDUSTRIAL PARK, DAFU INDUSTRIAL ZONE, GUANLAN, LONGHUA SHENZHEN, 518XXX China Manufacturer's Name .......... : SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Address .................................. : A2 2F BUILDING ENET NEW INDUSTRIAL PARK, DAFU INDUSTRIAL ZONE, GUANLAN, LONGHUA SHENZHEN, 518XXX China Product description Product name ........................ : Smart Phone Brand Name ......................... : OUKITEL Model and/or type reference : WP21 Family Model : WP21 Pro, WP21 S Standards ............................. : FCC 47 CFR Part 2(2.1093) ANSI/IEEE C95.1-1992 IEEE Std 1528-2013 Published RF exposure KDB procedures This device described above has been tested by Shenzhen NTEK. In accordance with the measurement methods and procedures specified in IEEE Std 1528-2013 and KDB 865664 D01. Testing has shown that this device is capable of compliance with localized specific absorption rate (SAR) specified in FCC 47 CFR Part 2(2.1093) and ANSI/IEEE C95.1-1992. The test results in this report apply only to the tested sample of the stated device/equipment. Other similar device/equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. This report shall not be reproduced except in full, without the written approval of Shenzhen NTEK, this document may be altered or revised by Shenzhen NTEK, personal only, and shall be noted in the revision of the document. Test Sample Number ............................... : S220922041011 Date of Test Date (s) of performance of tests .............. : Oct. 18, 2022 ~ Nov. 03, 2022 Date of Issue ........................................... : Nov. 09, 2022 Test Result ............................................... : Pass Prepared By (Test Engineer) : (Jacob Chen) Approved By (Lab Manager) : (Alex Li) Page 3 of 223 Report No.: S22092204106001 โ€ป โ€ป Revision History โ€ป โ€ป REV. DESCRIPTION ISSUED DATE REMARK Rev.1.0 Initial Test Report Release Nov. 09, 2022 Jacob Chen Page 4 of 223 Report No.: S22092204106001 TABLE OF CONTENTS 1. General Information ............................................................................................ 6 1.1. RF exposure limits .................................................................................... 6 1.2. Statement of Compliance ........................................................................ 7 1.3. EUT Description ....................................................................................... 7 1.4. Test specification(s) .................................................................................. 9 1.5. Ambient Condition ................................................................................... 9 2. SAR Measurement System ................................................................................. 10 2.1. SATIMO SAR Measurement Set-up Diagram .......................................... 10 2.2. Robot ..................................................................................................... 11 2.3. E-Field Probe .......................................................................................... 12 2.3.1. E-Field Probe Calibration ................................................................. 12 2.4. SAM phantoms ...................................................................................... 13 2.4.1. Technical Data .................................................................................. 14 2.5. Device Holder ........................................................................................ 15 2.6. Test Equipment List ................................................................................ 16 3. SAR Measurement Procedures .......................................................................... 18 3.1. Power Reference ................................................................................... 18 3.2. Area scan & Zoom scan .......................................................................... 18 3.3. Description of interpolation/extrapolation scheme .............................. 20 3.4. Volumetric Scan ..................................................................................... 20 3.5. Power Drift ............................................................................................ 20 4. System Verification Procedure .......................................................................... 21 4.1. Tissue Verification ................................................................................. 21 4.1.1. Tissue Dielectric Parameter Check Results ...................................... 22 4.2. System Verification Procedure .............................................................. 23 4.2.1. System Verification Results .............................................................. 24 5. SAR Measurement variability and uncertainty .................................................. 25 5.1. SAR measurement variability ................................................................. 25 5.2. SAR measurement unโ€ฆ

Text truncated - open the document above for the full version.

RF Exposure Info

Page 131 of 223 Report No.: S22092204106001 MEASUREMENT 25 Date of measurement: 18/10/2022 A. Experimental conditions. Area Scan dx=15mm dy=15mm, h= 5.00 mm ZoomScan 5x5x7,dx=8mm dy=8mm dz=5mm Phantom Left head Device Position Cheek Band LTE band 17 Channels Middle Signal LTE (Crest factor: 1.0) ConvF 1.49 B. SAR Measurement Results Frequency (MHz) 710.000000 Relative permittivity (real part) 40.657013 Relative permittivity (imaginary part) 21.648298 Conductivity (S/m) 0.853905 Variation (%) -1.110000 SURFACE SAR VOLUME SAR Maximum location: X=-54.00, Y=-30.00 SAR Peak: 0.17 W/kg SAR 10g (W/Kg) 0.108486 SAR 1g (W/Kg) 0.138941 Page 132 of 223 Report No.: S22092204106001 Z (mm) 0.00 4.00 9.00 14.00 19.00 24.00 29.00 SAR (W/Kg) 0.1687 0.1406 0.1139 0.1001 0.0791 0.0684 0.0543 3D screen shot Hot spot position Page 133 of 223 Report No.: S22092204106001 MEASUREMENT 26 Date of measurement: 18/10/2022 A. Experimental conditions. Area Scan dx=15mm dy=15mm, h= 5.00 mm ZoomScan 5x5x7,dx=8mm dy=8mm dz=5mm Phantom Validation plane Device Position Body Band LTE band 17 Channels Middle Signal LTE (Crest factor: 1.0) ConvF 1.49 B. SAR Measurement Results Frequency (MHz) 710.000000 Relative permittivity (real part) 40.657013 Relative permittivity (imaginary part) 21.648298 Conductivity (S/m) 0.853905 Variation (%) -0.100000 SURFACE SAR VOLUME SAR Maximum location: X=17.00, Y=17.00 SAR Peak: 0.21 W/kg SAR 10g (W/Kg) 0.128132 SAR 1g (W/Kg) 0.159362 Page 134 of 223 Report No.: S22092204106001 Z (mm) 0.00 4.00 9.00 14.00 19.00 24.00 29.00 SAR (W/Kg) 0.1862 0.1673 0.1413 0.1118 0.0906 0.0745 0.0609 3D screen shot Hot spot position Page 135 of 223 Report No.: S22092204106001 14. Appendix D. Calibration Certificate Table of contents E Field Probe - SN 08/16 EPGO287 750 MHz Dipole - SN 03/15 DIP 0G750-355 835 MHz Dipole - SN 03/15 DIP 0G835-347 1800 MHz Dipole - SN 03/15 DIP 1G800-349 1900 MHz Dipole - SN 03/15 DIP 1G900-350 2450 MHz Dipole - SN 03/15 DIP 2G450-352 2600 MHz Dipole - SN 03/15 DIP 2G600-356 5000-6000 MHz Dipole - SN 13/14 WGA 33 Extended Calibration Certificate Page 136 of 223 Report No.: S22092204106001 Page 137 of 223 Report No.: S22092204106001 Page 138 of 223 Report No.: S22092204106001 Page 139 of 223 Report No.: S22092204106001 Page 140 of 223 Report No.: S22092204106001 Page 141 of 223 Report No.: S22092204106001 Page 142 of 223 Report No.: S22092204106001 Page 143 of 223 Report No.: S22092204106001 Page 144 of 223 Report No.: S22092204106001 Page 145 of 223 Report No.: S22092204106001 Page 146 of 223 Report No.: S22092204106001 Page 147 of 223 Report No.: S22092204106001 Page 148 of 223 Report No.: S22092204106001 Page 149 of 223 Report No.: S22092204106001 Page 150 of 223 Report No.: S22092204106001 Page 151 of 223 Report No.: S22092204106001 Page 152 of 223 Report No.: S22092204106001 Page 153 of 223 Report No.: S22092204106001 Page 154 of 223 Report No.: S22092204106001 Page 155 of 223 Report No.: S22092204106001 Page 156 of 223 Report No.: S22092204106001 Page 157 of 223 Report No.: S22092204106001 Page 158 of 223 Report No.: S22092204106001 Page 159 of 223 Report No.: S22092204106001 Page 160 of 223 Report No.: S22092204106001 Page 161 of 223 Report No.: S22092204106001 Page 162 of 223 Report No.: S22092204106001 Page 163 of 223 Report No.: S22092204106001 Page 164 of 223 Report No.: S22092204106001 Page 165 of 223 Report No.: S22092204106001 Page 166 of 223 Report No.: S22092204106001 Page 167 of 223 Report No.: S22092204106001 Page 168 of 223 Report No.: S22092204106001 Page 169 of 223 Report No.: S22092204106001 Page 170 of 223 Report No.: S22092204106001 Page 171 of 223 Report No.: S22092204106001 Page 172 of 223 Report No.: S22092204106001 Page 173 of 223 Report No.: S22092204106001 Page 174 of 223 Report No.: S22092204106001 Page 175 of 223 Report No.: S22092204106001 Page 176 of 223 Report No.: S22092204106001 Page 177 of 223 Report No.: S22092204106001 Page 178 of 223 Report No.: S22092204106001 Page 179 of 223 Report No.: S22092204106001 Page 180 of 223 Report No.: S22092204106001

RF Exposure Info

Page 186 of 223 Report No.: S22092204106001 Page 187 of 223 Report No.: S22092204106001 Page 188 of 223 Report No.: S22092204106001 Page 189 of 223 Report No.: S22092204106001 Page 190 of 223 Report No.: S22092204106001 Page 191 of 223 Report No.: S22092204106001 Page 192 of 223 Report No.: S22092204106001 Page 193 of 223 Report No.: S22092204106001 Page 194 of 223 Report No.: S22092204106001 Page 195 of 223 Report No.: S22092204106001 Page 196 of 223 Report No.: S22092204106001 Page 197 of 223 Report No.: S22092204106001 Page 198 of 223 Report No.: S22092204106001 Page 199 of 223 Report No.: S22092204106001 Page 200 of 223 Report No.: S22092204106001 Page 201 of 223 Report No.: S22092204106001 Page 202 of 223 Report No.: S22092204106001 Page 203 of 223 Report No.: S22092204106001 Page 204 of 223 Report No.: S22092204106001 Page 205 of 223 Report No.: S22092204106001 Page 206 of 223 Report No.: S22092204106001 Page 207 of 223 Report No.: S22092204106001 Page 208 of 223 Report No.: S22092204106001 Page 209 of 223 Report No.: S22092204106001 Page 210 of 223 Report No.: S22092204106001 Page 211 of 223 Report No.: S22092204106001 Page 212 of 223 Report No.: S22092204106001 Page 213 of 223 Report No.: S22092204106001 Page 214 of 223 Report No.: S22092204106001 Page 215 of 223 Report No.: S22092204106001 Page 216 of 223 Report No.: S22092204106001 Page 217 of 223 Report No.: S22092204106001 <Justification of the extended calibration> If dipoles are verified in return loss (<-20dB, within 20% of prior calibration for below 3GHz, and <-8dB, within 20% of prior calibration for 5GHz to 6GHz), and in impedance (within 5 ohm of prior calibration), the annual calibration is not necessary and the calibration interval can be extended. <Head 750MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -23.80 - 56.4 - Mar. 01, 2021 -23.642 0.66 56.998 0.598 Feb. 28, 2022 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data Page 218 of 223 Report No.: S22092204106001 <Head 835MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -25.44 - 54.40 - Mar. 01, 2021 -25.803 1.43 54.492 0.092 Feb. 28, 2022 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data Page 219 of 223 Report No.: S22092204106001 <Head 1800MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -28.85 - 47.90 - Mar. 01, 2021 -28.545 1.06 47.809 0.091 Feb. 28, 2022 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data Page 220 of 223 Report No.: S22092204106001 <Head 1900MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -24.79 - 50.80 - Mar. 01, 2021 -24.518 1.10 50.516 0.284 Feb. 28, 2022 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data Page 221 of 223 Report No.: S22092204106001 <Head 2450MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -23.18 - 56.30 - Mar. 01, 2021 -23.39 0.91 56.342 0.042 Feb. 28, 2022 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data Page 222 of 223 Report No.: S22092204106001 <Head 2600MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -21.15 - 52.70 - Mar. 01, 2021 -21.248 0.46 53.053 0.353 Feb. 28, 2022 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data Page 223 of 223 Report No.: S22092204106001 <Head 5200MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -9.15 - 21.17 - Mar. 01, 2021 -9.1819 0.35 21.191 0.021 Feb. 28, 2022 The return loss is <-8dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data _______________________________________END _____________________________________

Test Report

Report No.: S22092204105004 Version.1.2 Page 1 of 93 FCC RADIO TEST REPORT FCC ID: 2ANMU-WP21 Product๏ผš Smart Phone Trade Mark๏ผš OUKITEL Model Name๏ผš WP21 Family Model๏ผš WP21 Pro, WP21 S Report No.๏ผš S22092204105004 Prepared for SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD A2 2F BUILDING ENET NEW INDUSTRIAL PARK, DAFU INDUSTRIAL ZONE, GUANLAN, LONGHUA,SHENZHEN, 518XXX China Prepared by Shenzhen NTEK Testing Technology Co., Ltd. 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street Baoโ€™an District, Shenzhen 518126 P.R. China Tel. 400-800-6106, 0755-2320 0050, 0755-2320 0090 Website: http://www.ntek.org.cn Report No.: S22092204105004 Version.1.2 Page 2 of 93 TEST RESULT CERTIFICATION Applicantโ€™s name ................. : SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Address ................................. : A2 2F BUILDING ENET NEW INDUSTRIAL PARK, DAFU INDUSTRIAL ZONE, GUANLAN, LONGHUA,SHENZHEN, 518XXX China Manufacturer's Name .......... : SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Address ................................. : A2 2F BUILDING ENET NEW INDUSTRIAL PARK, DAFU INDUSTRIAL ZONE, GUANLAN, LONGHUA,SHENZHEN, 518XXX China Product description Product name ........................... : Smart Phone Model and/or type reference : WP21 Family Model ............................. : WP21 Pro, WP21 S Test sample number S220922041012 Standards ............................. : FCC Part15.407 Test procedure ............................... : ANSI C63.10-2013 and KDB 789033 D02 General UNII Test Procedures New Rules v02r01 This device described above has been tested by NTEK, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements/ the Industry Canada requirements.. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of NTEK, this document may be altered or revised by NTEK, personnel only, and shall be noted in the revision of the document. Date of Test ............................................ : Date (s) of performance of tests ............. : 13 Oct. 2022 ~ 04 Nov, 2022 Date of Issue ........................................... : 08 Nov, 2022 Test Result ............................................... : Pass Testing Engineer : (Allen Liu) Authorized Signatory : (Alex Li) Report No.: S22092204105004 Version.1.2 Page 3 of 93 Table of Contents Page 1 . SUMMARY OF TEST RESULTS 5 1.1 FACILITIES AND ACCREDITATIONS 6 1.2 MEASUREMENT UNCERTAINTY 6 2 . GENERAL INFORMATION 7 2.1 GENERAL DESCRIPTION OF EUT 7 2.2 DESCRIPTION OF TEST MODES 9 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 10 2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) 11 2.5 EQUIPMENTS LIST FOR ALL TEST ITEMS 12 3 . TEST REQUIREMENTS 14 3.1 CONDUCTED EMISSION MEASUREMENT 14 3.2 RADIATED EMISSION MEASUREMENT 17 3.3 POWER SPECTRAL DENSITY TEST 28 3.4 26DB & 99% EMISSION BANDWIDTH 31 3.5 MINIMUM 6 DB BANDWIDTH 33 3.6 MAXIMUM CONDUCTED OUTPUT POWER 35 3.7 OUT OF BAND EMISSIONS 39 3.8 SPURIOUS RF CONDUCTED EMISSIONS 41 3.9 FREQUENCY STABILITY MEASUREMENT 42 4. ANTENNA REQUIREMENT 46 4.1 STANDARD REQUIREMENT 46 4.2 EUT ANTENNA 46 5. TEST RESULTS 47 5.1 DUTY CYCLE 47 5.2 MAXIMUM CONDUCTED OUTPUT POWER 55 5.3 OCCUPIED CHANNEL BANDWIDTH 56 5.4 MAXIMUM POWER SPECTRAL DENSITY LEVEL 71 5.5 BAND EDGE 79 5.6 CONDUCTED RF SPURIOUS EMISSION 86 Report No.: S22092204105004 Version.1.2 Page 4 of 93 Revision History Report No. Version Description Issued Date S22092204105004 Rev.01 Initial issue of report 08 Nov, 2022 Report No.: S22092204105004 Version.1.2 Page 5 of 93 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15 (15.407) , Subpart E Standard Section Test Item Judgment Remark 15.207 AC Power Line Conducted Emissions PASS 15.209(a), 15.407 (b)(1) 15.407 (b)(4) 15.407 (b)(6) Spurious Radiated Emissions PASS 15.407 (a)(1) 15.407 (a)(3) 26 dB and 99% Emission Bandwidth PASS 15.407(e) Minimum 6 dB bandwidth PASS 15.407 (a)(1) 15.407 (a)(3) Maximum Conducted Output Power PASS 15.407(b)(1) 15.407(b)(4) Band Edge PASS 15.407 (a)(1) 15.407 (a)(3) Power Spectral Density PASS 15.407(b) Spurious Emissions at Antenna Terminals PASS 15.203 Antenna Requirement PASS 15.407(c) Automatically discontinue transmission PASS NOTE: (1)โ€ N/Aโ€ denotes test is not applicable in this Test Report Report No.: S22092204105004 Version.1.2 Page 6 of 93 1.1 FACILITIES AND ACCREDITATIONS FACILITIES All measurement facilities used to collect the measurement data are located at 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street, Baoโ€™an District, Shenzhen 518126 P.R. China. The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.10 and CISPR Publication 22. LABORATORY ACCREDITATIONS AND LISTINGS Site Description CNAS-Lab. : The Certificate Registration Number is L5516. IC-Registration The Certificate Registration Number is 9270A. CAB identifier:CN0074 FCC- Accredited Test Firm Registration Number: 463705. Designation Number: CN1184 A2LA-Lab. The Certificate Registration Number is 4298.01 This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiquรฉ dated 8 January 2009). Name of Firm : Shenzhen NTEK Testing Technology Co., Ltd. Site Location : 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street, Baoโ€™an District, Shenzhen 518126 P.R. China. 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement yยฑU, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 Conducted Emission Test โ€ฆ

Text truncated - open the document above for the full version.

Test Report

One stop communication RF antenna solution provider ็ฌฌ 1 ้กต Shenzhen Anwei Wireless Technology Co., Ltd Specification / ๅฎขๆˆท Customer Cloud base ่ง„ๆ ผๅž‹ๅท Specs S105 ๅฎ‰ๅจๆ–™ๅท Part Number AW006-S105-020-A0 AW006-S105-021-A0 AW006-S105-022-A0 ้ข‘ ๆฎต Frequency Band BT&2.5G WIFI:2400~2483.5MHZ 5G WIFI:5100~5800MHZ GSM850/900/1800/1900 WCDMA1/2/4/5/6/8/19 CDMA BC0 BC1 BC10 B1.2.3.4.5.7.8.12.13.17.18.19.20.25.26.28.66.71 .34.38.39.40.41 ้ขœ ่‰ฒ Color black ็‰ˆ ๆœฌ Edition REV:A1 ้”€ ๅ”ฎ Salesperson Mr.Xie ่ฎพ ่ฎก Design WUXI ็ป“ ๆž„ Structure QIN YUN LIN ็กฎ ่ฎค Confirm ๆ—ฅ ๆœŸ Date 2022/11/16 ็ญพๅญ—ๆ—ฅๆœŸ Signing Date ๅฎขๆˆท็กฎ่ฎคCustomer confirmation: ๆบๆ‰‹ๅ…ฑ่ฟ› ๅ…ฑๅˆ›ๆœชๆฅ Join hands to create the future One stop communication RF antenna solution provider ็ฌฌ 2 ้กต ็›ฎๅฝ• ไธ€ใ€ไบงๅ“่ง„ๆ ผ(Product specification) ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 3 ไบŒใ€็”ตๅ™จๆ€ง่ƒฝ(Electrical performance) ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 3 1.่ง„ๆ ผๆ ‡ๅ‡†(Specification standard) ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 3 2.ๅคฉ็บฟ็š„ๅŒน้…็”ต่ทฏ(Matching circuit) ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 3 ไธ‰ใ€ๅ‚ๆ•ฐ็š„ๆต‹่ฏ•(Parameter test) ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 4 1.ๆต‹่ฏ•็š„่ฎพ็ฝฎ(Test settings) ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 4 2.ๆต‹่ฏ•็ป“ๆžœ(Test result) ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 4 ๅ››ใ€ๆœ‰ๆบๆต‹่ฏ•็š„่ฎพ็ฝฎ(Active test setup) ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 5 1.ๆต‹่ฏ•็š„ๅœบๅœฐ(Test site) ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทโ€ฆ

Text truncated - open the document above for the full version.

Contact Information

Applicant

Gaolei Yan(Manager)
[email protected]0755-61156588Fax: 0755-61156588

Technical Contact

SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD
[email protected]

China

Test Firm

Shenzhen NTEK Testing Technology Co., Ltd.Alex Li
[email protected]+86-755-6115-9384

Technical Specifications

#Rule PartsFrequency RangePower Output
115E5.18 GHz - 5.24 GHz10.54 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router), and simultaneous transmission use conditions is 0.54W/kg, 0.39W/kg, 0.39W/kg and 1.14W/kg respectively.

Other Applications from SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD

Smart phone - FCC ID 2ANMU-C17MINI - SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD
2ANMU-C17MINI

Smart phone

Sep 18, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Smart phone - FCC ID 2ANMU-P2 - SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD
2ANMU-P2

Smart phone

Sep 01, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Tablet - FCC ID 2ANMU-RT11 - SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD
2ANMU-RT11

Tablet

Aug 19, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Smart phone - FCC ID 2ANMU-C71 - SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD
2ANMU-C71

Smart phone

Jul 01, 2026

Equipment Class

PCE - PCS Licensed Transmitter held to ear
Smart Phone - FCC ID 2ANMU-C8 - SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD
2ANMU-C8

Smart Phone

Jun 05, 2026

Equipment Class

PCE - PCS Licensed Transmitter held to ear