Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
202, Building A2, Silicon Valley Power Intelligent Terminal Industrial Park, No. 20, Dafu Industrial Zone, Kukeng Community, Guanlan Street, Longhua District, Shenzhen China WP26 WP26 Front camera Type-C MIC Speaker Sound Hole Touch screen Receiver Light Distance 10000 81 SIM Card Ejector Power button + fingerprint key Volume + Flash + night vision light Volume - SIM card slot Camping Lights Smart Key Rear main camera Macro camera Night Vision camera SIM1 Card SIM2 Card 2 SIM2 Card oukitel.com FCC Statement Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions (1)this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. FCC/IC RF Radiation Exposure and SAR Statements The Smart Phone WP26 has been tested for body-worn Specific Absorption Rate(SAR) compliance. The FCC/IC has established detailed SAR requirements and has established that these requirements. RF Exposure Information The radio module has been evaluated under FCC Bulletin C95.1 and IEEE 1528 and found to be compliant to RF Exposure from radio frequency devices. This model meets the applicable government requirements for exposure to radio frequency waves. The highest reported SAR level for usage near the body (10mm) is 0.355 W/kg, Body transmission is 0.586W/kg at the same time.SAR level for usage near the Head is 0.746 W/kg and Head simultaneous transmission is 1.352 W/kg ,SAR level for usage near the Hotspot is 0.461 W/kg and Hotspot simultaneous transmission is 0.586 W/kg
SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD 2.911 (d)(5)(i) Equipment Type Attestation v1.2 Section 2.911(d)(5)(i) Certification – Equipment Type Company name: SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Address: A2 2F BUILDING ENET NEW INDUSTRIAL PARK, DAFU INDUSTRIAL ZONE, GUANLAN, LONGHUA SHENZHEN, 518XXX China Product Name: Smart Phone FCC ID: 2ANMU-WP26SPU Model(s): WP26, WP26 S,WP26 Pro,WP26 Ultra 2.911(d)(5)(i) Equipment Type We, [SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD] (“the applicant”) certify that the equipment for which authorization is sought through certification is not: Prohibited from receiving an equipment authorization pursuant to § 2.903; of the FCC rules. Identified as an equipment type in the “Covered List” NOTE 1 Yours sincerely, Name: Date: 2023.5.4 Title and Company name: Gaolei Yan/ Manager NOTE 1 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
(SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD) U.S. Agent Designation for Service of Process (Applicant and U.S. Agent are Separate Parties) TO: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 ATTENTION: FCC Certification – Section 2.911(d)(7) Information Designated U.S. Agent Company Name: Baihetian Innovative Solutions FRN: 0033401605 Contact Name: Kenneth Young Street Address: 6837 Chase Rd City/Province/Zip: Dearborn, MI 48126 Telephone No: 313-395-3113 Email: [email protected] This letter is to confirm that we (“the Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. U.S. Agent Signature: Date: Feb 20, 2023 Signed by (Printed Name/Title): Kenneth Young/ Manager The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of a ny Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant Company name: SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Grantee Code: 2ANMU FCC ID: 2ANMU-WP26SPU Contact Name: Gaolei Yan Street Address: A2 2F BUILDING ENET NEW INDUSTRIAL PARK, DAFU INDUSTRIAL ZONE, GUANLAN, LONGHUA City/Province/Zip: SHENZHEN,China Telephone No: 0755-61156588 Email: [email protected] Applicant Signature: Date:2023.5.29 Signed by (Printed Name/Title): Gaolei Yan/ Manager
SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Authorization Company: SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Address: A2 2F BUILDING ENET NEW INDUSTRIAL PARK, DAFU INDUSTRIAL ZONE, GUANLAN, LONGHUA SHENZHEN, 518XXX China Product Name: Smart Phone Model Number(s): WP26, WP26 S,WP26 Pro,WP26 Ultra Product Description: Smart Phone We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2023/05/24 Name: Gaolei Yan Title: Manager Company: SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD
SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Subject; Request for Confidentiality FCC ID: 2ANMU-WP26SPU Date: 2023/05/24 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description BOM Tune-up Procedure software security requirement In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuantto KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Gaolei Yan Title: Manager
SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Model Difference 2023/05/24 EUT NAME: Smart Phone FCC ID: FCC ID: 2ANMU-WP26SPU MODEL : WP26, WP26 S,WP26 Pro,WP26 Ultra All the model are the same circuit and RF module, except model names. Sincerely Client’s signature Client’s name / title : Gaolei Yan / manager Contact information / address: A2 2F BUILDING ENET NEW INDUSTRIAL PARK, DAFU INDUSTRIAL ZONE, GUANLAN, LONGHUA SHENZHEN, 518XXX China
External Photos
Size:40*20mm Smart Phone FCC ID: 2ANMU-WP26SPU This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Label location
Internal Photos Antenna BT/WIFI Main Antenna 2G/3G/4G DIV Antenna 2G/3G/4G NFC Antenna
No.:BCTC/RF-EMC-005 Page 1 of 259 Edition:A.4 FCC SAR TEST REPORT Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC2304811624-8E Applicant: SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Product Name: Smart Phone Model/Type Ref.: WP26 Tested Date: 2023-04-07 to 2023-05-17 Issued Date: 2023-05-22 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 2 of 259 Edition:A.4 FCC ID: 2ANMU-WP26SPU The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen BCTC Testing Co., Ltd, this report can’t be reproduced except in full. The tested sample(s) and the sample information are provided by the client. Product Name: Smart Phone Trademark: OUKITEL Model/Type Ref.: WP26 WP26 S, WP26 Pro, WP26 Ultra Applicant: SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Address: A2 2F BUILDING ENET NEW INDUSTRIAL PARK, DAFU INDUSTRIAL ZONE, GUANLAN, LONGHUA SHENZHEN, 518XXX China Manufacturer: SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD Address: A2 2F BUILDING ENET NEW INDUSTRIAL PARK, DAFU INDUSTRIAL ZONE, GUANLAN, LONGHUA SHENZHEN, 518XXX China Prepared By: Shenzhen BCTC Testing Co., Ltd. Address: 1-2/F., Building B, Pengzhou Industrial Park, No.158, Fuyuan 1st Road, Zhancheng, Fuhai Subdistrict, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: 2023-04-07 Sample tested Date: 2023-04-07 to 2023-05-17 Issue Date: 2023-05-22 SAR Max. Values is: 0.746 W/kg (1g) for Head 0.355 W/kg (1g) for Body 0.461 W/kg (1g) for Hotspot Test Standards: IEEE Std C95.1, 2019/ IEEE Std 1528™-2013/FCC Part 2.1093 Test Results: PASS Remark: This is SAR test report Tested by: Approved by: Hubery Cai/Project Handler Zero Zhou/Reviewer Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 3 of 259 Edition:A.4 Table Of Content Test Report Declaration Page 1. Version .................................................................................................................. 5 2. Test Standards ...................................................................................................... 6 3. Test Summary ....................................................................................................... 7 4. SAR Limits............................................................................................................. 8 5. Measurement Uncertainty ..................................................................................... 9 6. Product Information and Test Setup .................................................................... 10 6.1 Product Information ............................................................................................... 10 6.2 Test Setup Configuration ....................................................................................... 13 6.3 Support Equipment ................................................................................................ 13 6.4 Test Environment .................................................................................................. 13 7. Test Facility and Test Instrument Used ............................................................... 14 7.1 Test Facility ........................................................................................................... 14 7.2 Test Instrument Used ............................................................................................ 14 8. Specific Absorption Rate (SAR) .......................................................................... 16 8.1 Introduction ............................................................................................................ 16 8.2 SAR Definition ....................................................................................................... 16 9. SAR Measurement System ................................................................................. 17 9.1 The Measurement System ..................................................................................... 17 9.2 Probe ..................................................................................................................... 17 9.3 Probe Calibration Process ..................................................................................... 19 9.4 Phantom ................................................................................................................ 20 9.5 Device Holder ........................................................................................................ 20 10. Tissue Simulating Liquids .................................................................................... 21 10.1 Composition of Tissue Simulating Liquid ............................................................. 21 10.2 Limit ..................................................................................................................... 22 10.3 Tissue Calibration Result ..................................................................................... 23 11. System Check ..................................................................................................... 24 11.1 Purpose of System Performance Check .............................................................. 24 11.2 System Setup ...................................................................................................... 24 11.3 Validation Results ................................................................................................ 25 12. EUT Testing Position ........................................................................................... 26 12.1 Define Two Imaginary Lines on the Handset ....................................................... 26 12.2 Cheek Position .................................................................................................... 27 12.3 Tilted Position ...................................................................................................... 27 12.4 Body Position .....…
Text truncated - open the document above for the full version.
Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 81 of 259 Edition:A.4 15.2 SAR Test Graph Results SAR plots for the highest measured SAR in each exposure configuration, wireless mode and frequency band combination according to FCC KDB 865664 D02 Plot 1 A. Experimental conditions. Probe SN 25/22 EPGO373 ConvF 3.01 Area Scan dx=8mm dy=8mm, Adaptative 1 max Zoom Scan 7x7x8,dx=5mm dy=5mm dz=5mm Phantom Right head Device Position Cheek Band GSM850 Channels Middle Signal TDMA (Crest factor: 8.0) B. Permitivity Frequency (MHz) 836.600 Relative permitivity (real part) 40.702 Relative permitivity (imaginary part) 19.384 Conductivity (S/m) 0.923 C. SAR Surface and Volume SURFACE SAR VOLUME SAR Maximum location: X=-47.00, Y=-42.00 ; SAR Peak: 0.15 W/kg D. SAR 1g & 10g SAR 10g (W/Kg) 0.089 SAR 1g (W/Kg) 0.120 Variation (%) -2.240 Horizontal validation criteria: minimum distance (mm) -- Vertical validation criteria: SAR ratio M2/M1 (%) -- Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 82 of 259 Edition:A.4 E. Z Axis Scan Z (mm) 0.00 4.00 8.00 12.00 16.00 SAR (W/Kg) 0.226 0.124 0.097 0.086 0.068 F. 3D Image 3D screen shot Hot spot position Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 83 of 259 Edition:A.4 Plot 2 A. Experimental conditions. Probe SN 25/22 EPGO373 ConvF 3.01 Area Scan surf_sam_plan.txt Zoom Scan 7x7x8,dx=5mm dy=5mm dz=5mm Phantom Validation plane Device Position Body Band GPRS850_4TX Channels Middle Signal Custom (Crest factor: 2.0) B. Permitivity Frequency (MHz) 836.600 Relative permitivity (real part) 40.702 Relative permitivity (imaginary part) 19.384 Conductivity (S/m) 0.923 C. SAR Surface and Volume SURFACE SAR VOLUME SAR Maximum location: X=-7.00, Y=15.00 ; SAR Peak: 0.38 W/kg D. SAR 1g & 10g SAR 10g (W/Kg) 0.163 SAR 1g (W/Kg) 0.257 Variation (%) 1.830 Horizontal validation criteria: minimum distance (mm) -- Vertical validation criteria: SAR ratio M2/M1 (%) -- E. Z Axis Scan Z (mm) 0.00 4.00 8.00 12.00 16.00 SAR (W/Kg) 0.610 0.271 0.177 0.142 0.094 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 84 of 259 Edition:A.4 F. 3D Image 3D screen shot Hot spot position Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 85 of 259 Edition:A.4 Plot 3 A. Experimental conditions. Probe SN 25/22 EPGO373 ConvF 3.27 Area Scan dx=8mm dy=8mm, Adaptative 1 max Zoom Scan 7x7x8,dx=5mm dy=5mm dz=5mm Phantom Right head Device Position Tilt Band GSM1900 Channels Middle Signal TDMA (Crest factor: 8.0) B. Permitivity Frequency (MHz) 1880.000 Relative permitivity (real part) 40.662 Relative permitivity (imaginary part) 13.408 Conductivity (S/m) 1.394 C. SAR Surface and Volume SURFACE SAR VOLUME SAR Maximum location: X=-10.00, Y=30.00 ; SAR Peak: 0.94 W/kg D. SAR 1g & 10g SAR 10g (W/Kg) 0.201 SAR 1g (W/Kg) 0.445 Variation (%) -1.530 Horizontal validation criteria: minimum distance (mm) -- Vertical validation criteria: SAR ratio M2/M1 (%) -- E. Z Axis Scan Z (mm) 0.00 4.00 8.00 12.00 16.00 SAR (W/Kg) 0.939 0.481 0.231 0.108 0.053 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 86 of 259 Edition:A.4 F. 3D Image 3D screen shot Hot spot position Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 87 of 259 Edition:A.4 Plot 4 A. Experimental conditions. Probe SN 25/22 EPGO373 ConvF 3.27 Area Scan surf_sam_plan.txt Zoom Scan 7x7x8,dx=5mm dy=5mm dz=5mm Phantom Validation plane Device Position Body Band GPRS1900_4TX Channels Low Signal Custom (Crest factor: 2.0) B. Permitivity Frequency (MHz) 1850.200 Relative permitivity (real part) 40.689 Relative permitivity (imaginary part) 13.629 Conductivity (S/m) 1.386 C. SAR Surface and Volume SURFACE SAR VOLUME SAR Maximum location: X=23.00, Y=-18.00 ; SAR Peak: 0.45 W/kg D. SAR 1g & 10g SAR 10g (W/Kg) 0.126 SAR 1g (W/Kg) 0.242 Variation (%) -0.090 Horizontal validation criteria: minimum distance (mm) -- Vertical validation criteria: SAR ratio M2/M1 (%) -- E. Z Axis Scan Z (mm) 0.00 4.00 8.00 12.00 16.00 SAR (W/Kg) 0.449 0.257 0.141 0.077 0.042 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 88 of 259 Edition:A.4 F. 3D Image 3D screen shot Hot spot position Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 89 of 259 Edition:A.4 Plot 5 A. Experimental conditions. Probe SN 25/22 EPGO373 ConvF 3.27 Area Scan surf_sam_plan.txt Zoom Scan 7x7x8,dx=5mm dy=5mm dz=5mm Phantom Validation plane Device Position Body Band GPRS1900_4TX Channels Low Signal Custom (Crest factor: 2.0) B. Permitivity Frequency (MHz) 1850.200 Relative permitivity (real part) 40.689 Relative permitivity (imaginary part) 13.629 Conductivity (S/m) 1.386 C. SAR Surface and Volume SURFACE SAR VOLUME SAR Maximum location: X=15.00, Y=9.00 ; SAR Peak: 0.63 W/kg D. SAR 1g & 10g SAR 10g (W/Kg) 0.165 SAR 1g (W/Kg) 0.323 Variation (%) 0.090 Horizontal validation criteria: minimum distance (mm) -- Vertical validation criteria: SAR ratio M2/M1 (%) -- E. Z Axis Scan Z (mm) 0.00 4.00 8.00 12.00 16.00 SAR (W/Kg) 0.628 0.340 0.177 0.094 0.053 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 90 of 259 Edition:A.4 F. 3D Image 3D screen shot Hot spot position Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 91 of 259 Edition:A.4 Plot 6 A. Experimental conditions. Probe SN 25/22 EPGO373 ConvF 3.27 Area Scan dx=8mm dy=8mm, Adaptative 1 max Zoom Scan 7x7x8,dx=5mm dy=5mm dz=5mm Phantom Right head Device Position Cheek Band WCDMA1900 Channels High Signal WCDMA (Crest factor: 1.0) B. Permitivity Frequency (MHz) 1907.600 Relative permitivity (real part) 40.605 Relative permitivity (imaginary part) 13.210 Conductivity (S/m) 1.409 C. SAR Surface and Volume SURFACE SAR VOLUME SAR Maximum location: X=-16.00, Y=30.00 ; SAR Peak: 1.13 W/kg D. SAR 1g & 10g SAR 10g (W/Kg) 0.292 SAR 1g (W/Kg) 0.581 Variation (%) -0.070 Horizontal validation criteria: minimum distance (mm) -- Vertical validation criteria: SAR ratio M2/M1 (%) -- E. Z Axis Scan Z (mm) 0.00 4.00 8.00 12.00 16.00 SAR (W/Kg) 1.127 0.614 0.319 0.164 0.088 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 92 of 259 Edition:A.4 F. 3D Ima…
Text truncated - open the document above for the full version.
Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 150 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 151 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 152 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 153 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 154 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 155 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 156 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 157 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 158 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 159 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 160 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 161 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 162 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 163 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 164 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 165 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 166 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 167 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 168 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 169 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 170 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 171 of 259 Edition:A.4
Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 172 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 173 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 174 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 175 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 176 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 177 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 178 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 179 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 180 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 181 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 182 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 183 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 184 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 185 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 186 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 187 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 188 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 189 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 190 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 191 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 192 of 259 Edition:A.4
Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 193 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 194 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 195 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 196 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 197 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 198 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 199 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 200 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 201 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 202 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 203 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 204 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 205 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 206 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 207 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 208 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 209 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 210 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 211 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 212 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 213 of 259 Edition:A.4
Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 214 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 215 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 216 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 217 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 218 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 219 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 220 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 221 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 222 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 223 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 224 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 225 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 226 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 227 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 228 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 229 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 230 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 231 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 232 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 233 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 234 of 259 Edition:A.4
Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 235 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 236 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 237 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 238 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 239 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 240 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 241 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 242 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 243 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 244 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 245 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 246 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 247 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 248 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 249 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 250 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 251 of 259 Edition:A.4 Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 252 of 259 Edition:A.4 17. EUT Photographs EUT Front View EUT Back View Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 253 of 259 Edition:A.4 Antenna View Antenna information Antenna Support Band WWAN GSM 850+WCDMA Band 5+LTE Band 5/12/17 TRX DIV GSM 1900+WCDMA Band 2/4+LTE Band 2/4/7 TRX BT/WIFI BT+2.4G WIFI+5G WIFI WIFI/BT Antenna WWAN Antenna DIV Antenna Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 254 of 259 Edition:A.4 18. EUT Test Setup Photographs Head mode Exposure Conditions Left Cheek Left Tilt Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 255 of 259 Edition:A.4 Right Cheek Right Tilt Report No:BCTC2304811624-8E No.:BCTC/RF-EMC-005 Page 256 of 259 Edition:A.4 Body mode Exposure Conditions Test distance: 10mm Front…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 28 | 27 | 706.5 MHz - 713.5 MHz | 90.00 mW | 4M52W7D | 0.0018521 ppm |

Smart phone
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Smart phone
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Tablet
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Smart phone
Equipment Class
PCE - PCS Licensed Transmitter held to ear
Smart Phone
Equipment Class
PCE - PCS Licensed Transmitter held to ear