FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SACKit ApS/
  3. 2AO5W-CHARGEITDD

2AO5W-CHARGEITDDDual Wireless Charging Pad

SACKit ApS
Dual Wireless Charging Pad - FCC ID 2AO5W-CHARGEITDD - SACKit ApS
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Jul 22, 2020
Application Purpose
Original Equipment
Date of Application
Jul 22, 2020
Equipment Note
Dual Wireless Charging Pad
Frequency Range
0.11000000 - 0.20500000
Company
SACKit ApS
Country
Denmark

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

80*100mm 1:1 无线充电器说明书 FD17 ST10 / 128gFSC认证哑粉纸 四色印刷 装骑马钉 2020.7.7 1.0 CHARGEit Dual Dock QUICK START GUIDE Danish designWireless fast charging LED indicator Dual wireless charging QUICK START GUIDE (DK) medfølger ikke) Vi anbefaler QC3.0 output 9V/3A - nalitet af CHARGEit Dual Dock. Brug af en QC1.0/QC2.0 adapter kan resultere i en overophedet enhed og kan skabe defekter i produktet. Ved opladning af ved brug af en QC1.0/QC2.0 adapter. QC3.0 adaptere kan nemt købes på diverse Brug CHARGEit Dual Dock Brugermanual Advarsel: Læs brugsanvisningen før du tager produktet i brug. Hent bruger manual online på følgende link: sackit.dk/support. Her kan du downloade bru- - Plug CHARGEit Dual Dock to a power supply with the supplied USB-C cable (adaptor not included) Choose the correct adaptor f or CHARGEit Dual Dock of CHARGEit Dual Dock. We recommend QC3.0 output 9V/3A SACKit recommends that you choose a QC3.0 adaptor t o achieve the best two devices at once require more power than what a QC1.0/QC2.0 adapter can deliver. SACKit will not be responsible for any issues or safety hazards arising fr om the use of a QC1.0/QC2.0 adaptor. QC3.0 adaptors can be purchased on various websites. Use CHARGEit Dual Dock You can charge up to two devices wirelessly with CHARGEit Dual Dock by placing your units on the X’s if the units supports wireless charging. User manual Warning: Read the user manual thoroughly before using the product. Download user manual online at: sackit.eu/support. Please download the user manual and QUICK START GUIDE (UK) QUICK START GUIDE (NO) (adapter f ølger ikke med) SACKit anbefaler QC3.0 output 9V/3A SACKit anbefaler a t du velger en QC3.0-adapter f or å sikre stabiliteten og QC2.0-adapter kan levere. SACKit vil ikke være ansvarlig for funksjonsfeil Bruk CHARGEit Dual Dock - Bruksanvisning Advarsel: L es bruksanvisningen før du tar i bruk produktet. Hent bruksanvisning online på følgende lenke: sackit.no/support. Her kan du QUICK START GUIDE (DE) Schließen Sie CHARGEit Dual Dock über das mitgelieferte USB-C Kabel an Str om an (ein Akku wird nicht mitgeliefert). Dock Möglichkeiten zur Auswahl: SACKit emphielt QC3.0 Output 9V/3A es zur Überhitzungen führen oder andere Defekte am CHARGEit Dual Dock Sicherheitsrisiken, die durch den Gebrauch eine QC1.0/QC2.0 Akkus entstanden Anwendung Laden Sie Ihren CHARGEit Dual Dock auf, indem Sie Ihr Handy auf dem X plat- Gebrauchsanleitung Achtung: Produkt in Gebrauch nehmen. Laden Sie die Gebrauchsanleitung für den späte- ren Gebrauch herunter: sackit.dk/support. Anleitungen un verschiedene Sicherheitshinweise. SACKit ApS Lyngvej 1 9000 Aalborg Denmark FCC WARNING This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be installed and operated with minimum distance between 20cm the radiator your body: Use only the supplied antenna. FCC ID: Warning: Changes or modifications to this unit not expressly approved by the part responsible for compliance could void the user’s authority to operate the equipment

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Letter of Authorization < SACKit ApS > Company: SACKit ApS Address: Lyngvej 1,DK-9000 Aalborg,Denmark Product Name: Dual Wireless Charging Pad Model Number: CHARGEit Stand Dock FCC Identifier: 2AO5W-CHARGEITDD We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Peter Rasmussen Date: 7/21/20 Title: Manager Signature of applicant:

Cover Letter(s)

C5266091_X10_Ed.2 1/1 < SACKit ApS > Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 7/21/20 Subject: Request for Confidentiality FCC ID: 2AO5W-CHARGEITDD To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long‐Term Confidentiality may be permitted under special conditions (See II. LONG‐TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short‐Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ______ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name: Peter Rasmussen Title: Manager

External Photos

- Page 1 of 4 - Report No.: MTi20041324-5E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China APPENDIX 1: EUT PHOTO Photo 1 (For model CHAGREit Dual Dock) Photo 2 - Page 2 of 4 - Report No.: MTi20041324-5E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 3 Photo 4 - Page 3 of 4 - Report No.: MTi20041324-5E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 5 Photo 6 - Page 4 of 4 - Report No.: MTi20041324-5E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 7 ----END OF REPORT----

ID Label/Location Info

39.50 mm i t ® Dual Wireless Charging Pad CHARGEit Dual Dock lnput:5V/3A,9V/3A,12V/2.5A Output:SW/7.SW/lOW X 2 � FCC ID: 2AOSW-CHARGEITDD Made in Chin EE g · �£

Internal Photos

- Page 1 of 2 - Report No.: MTi20041324-5E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China APPENDIX 1: EUT PHOTO Photo 1 (For model CHAGREit Dual Dock) Photo 2 Coil Antenna - Page 2 of 2 - Report No.: MTi20041324-5E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 3 Photo 4 ----END OF REPORT----

RF Exposure Info

This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen Microtest Co., Ltd. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China EXPOSURE REPORT FCC ID: 2AO5W-CHARGEITDD Date of issue: July 24, 2020 Report Number: MTi20041324-5E2 Sample Description: Dual Wireless Charging Pad Model(s): CHARGEit Dual Dock Applicant: SACKit ApS Address: Lyngvej 1, DK-9000 Aalborg, Denmark Date of Test: June 22, 2020 – July 10, 2020 Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 9 - Report No.: MTi20041324-5E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Test Result Certification Applicant’s name: SACKit ApS Address: Lyngvej 1, DK-9000 Aalborg, Denmark Manufacture's name: Shenzhen Powerqi Technology Co., Ltd. Address: 2nd&3rd Floor, Building A4, Block A, Fangxing Science & Tech. Park, No. 13 of BaoNan Road, Longgang District, Shenzhen, China Product name: Dual Wireless Charging Pad Trademark: SACKit Model name: CHARGEit Dual Dock Standard: FCC CFR 47 PART 1 , 1.1310 RF Exposure Procedures: KDB 680106 D01 RF Exposure Wireless Charging App v03 This device described above has been tested by Shenzhen Microtest Co., Ltd. and the test results show that the equipment under test (EUT) compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. Tested by: Danny Xu July 10, 2020 Reviewed by: Leo Su July 24, 2020 Approved by: Tom Xue July 24, 2020 - Page 3 of 9 - Report No.: MTi20041324-5E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China 1 General Information 1.1 Description of EUT Product name: Dual Wireless Charging Pad Brand name: SACKit Model name: CHARGEit Dual Dock Series model: N/A Deference in serial model: N/A Operation frequency: 110–205 kHz Operational mode: Wireless charging Modulation type: ASK Antenna type: Coil Antenna Power source: DC 9V from adapter AC 120V/60Hz Battery: N/A Adapter information: N/A 1.2 Ancillary equipment list Equipment Model S/N Manufacturer Adapter HW-090200CH0 / Huizhou BYD Electronics Co., Ltd. Load 1 / / / Load 2 / / / 1.3 Measurement uncertainty Measurement Uncertainty for a Level of Confidence of 95 %, U=2xUc(y) Radiated emission(150kHz~30MHz) ± 2.5 dB Radiated emission(30MHz~1GHz) ± 4.2 dB Radiated emission (above 1GHz) ± 4.3 dB Temperature ±1 degree Humidity ± 5 % - Page 4 of 9 - Report No.: MTi20041324-5E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China 2 Testing site Test Site Shenzhen Microtest Co., Ltd Test Site Location No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China FCC Registration No.: 448573 - Page 5 of 9 - Report No.: MTi20041324-5E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China 3 List of test equipment Equipment No. Equipment Name Manufacturer Model Serial No. Calibration date Due date MTI-E068 Broadband Field Meter Narda Safety Test Solutions GmbH NBM- 520 D-1699 2019/07/13 2020/07/12 MTI-E069 Probe E-Field Narda Safety Test Solutions EF0691 H-0571 2019/07/13 2020/07/12 - Page 6 of 9 - Report No.: MTi20041324-5E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China 4 Test Results 4.4 Maximum permissible exposure 4.4.1 Limit Frequency range(MHz) Electric field strength(V/m) Magnetic field strength(A/m) Power density(mW/cm2) Averaging time(minutes) (A) Limits for Occupational/Controlled Exposure 0.3-3.0 614 1.63 *100 6 3.0-30 1842/f 4.89/f *900/f 2 6 30-300 61.4 0.163 1.0 6 6 300-1500 f/300 6 1500-100000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3-1.34 614 1.63 *100 30 1.34-30 824/f 2.19/f *180/f 2 30 30-300 27.5 0.073 0.2 30 300-1500 f/1500 30 1500-100000 1 30 f = frequency in MHz * = Plane-wave equivalent power density 4.4.2 Test Procedures E and H-field measurements should be made with the center of the probe at a distance of 15 cm surrounding the device and 20 cm above the top surface of the primary/client pair. These measurements should be repeated for three different client battery levels, 1%, 50%, and 99%. Record the test results. KDB 680106 D01 RF Exposure Wireless Charging App v03: (1) Power transfer frequency is less than 1MHz. (2) Output power from each primary coil is less than or equal to 15 watts. (3) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils. (4) Client device is placed directly in contact with the transmitter. (5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). (6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. - Page 7 of 9 - Report No.: MTi20041324-5E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://ww…

Text truncated - open the document above for the full version.

Test Report

This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen Microtest Co., Ltd. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Test Report FCC ID:2AO5W-CHARGEITDD Date of issue: July 24, 2020 Report number: MTi20041324-5E1 Sample description: Dual Wireless Charging Pad Model(s): CHARGEit Dual Dock Applicant: SACKit ApS Address: Lyngvej 1, DK-9000 Aalborg, Denmark Date of test: June 22, 2020 – July 10, 2020 Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 25 - Report No.: MTi20041324-5E1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Table of Contents 1 GENERAL INFORMATION ................................................................................................................................. 4 1.1 FEATURE OF EQUIPMENT UNDER TEST (EUT) ................................................................................................................... 4 1.2 TEST MODE .............................................................................................................................................................. 4 1.3 EUT TEST SETUP ....................................................................................................................................................... 5 1.4 ANCILLARY EQUIPMENT .............................................................................................................................................. 5 2 SUMMARY OF TEST RESULT ............................................................................................................................. 6 2.1 OPERATION CHANNEL LIST ........................................................................................................................................... 6 2.2 TEST CHANNEL .......................................................................................................................................................... 6 3 TEST FACILITIES AND ACCREDITATIONS ............................................................................................................ 7 3.1 TEST LABORATORY ..................................................................................................................................................... 7 3.2 ENVIRONMENTAL CONDITIONS ..................................................................................................................................... 7 3.3 MEASUREMENT UNCERTAINTY ...................................................................................................................................... 7 3.4 TEST SOFTWARE ........................................................................................................................................................ 7 4 LIST OF TEST EQUIPMENT ................................................................................................................................ 8 5 TEST RESULTS .................................................................................................................................................. 9 5.1 ANTENNA REQUIREMENT ............................................................................................................................................ 9 5.1.1 Standard requirement ................................................................................................................................. 9 5.1.2 EUT Antenna ............................................................................................................................................... 9 5.2 CONDUCTED EMISSION ............................................................................................................................................. 10 5.2.1 Limits ......................................................................................................................................................... 10 5.2.2 Test Procedures ......................................................................................................................................... 10 5.2.3 Test Setup .................................................................................................................................................. 10 5.2.4 Test Result ................................................................................................................................................. 10 5.3 RADIATED EMISSION ................................................................................................................................................. 15 5.3.1 Limits ......................................................................................................................................................... 15 5.3.2 Test Procedures ......................................................................................................................................... 16 5.3.3 Test Setup .................................................................................................................................................. 17 5.3.4 Test Result ................................................................................................................................................. 17 5.4 OCCUPIED BANDWIDTH ............................................................................................................................................ 21 5.4.1 Test method ............................................................................................................................................... 21 5.4.2 Test result .................…

Text truncated - open the document above for the full version.

Test Setup Photos

Model: CHAGREit Dual Dock Radiated emission Conducted emission

Contact Information

Applicant

Peter Rasmussen
[email protected]+4530613631Fax: N/A

Technical Contact

Shenzhen Microtest Co., LtdSmith Chen
[email protected]86-755 88850135

Shenzhen · China

Test Firm

Shenzhen Microtest Co., Ltd.Selby Liao
[email protected]0755-88850135-1193

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.11 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from SACKit ApS

Bluetooth Speaker - FCC ID 2AO5W-MOVE100 - SACKit ApS
2AO5W-MOVE100

Bluetooth Speaker

Aug 11, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Wireless Charging Pad - FCC ID 2AO5W-CHARGE50 - SACKit ApS
2AO5W-CHARGE50

Wireless Charging Pad

Jun 28, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Bluetooth True Wireless Headset - FCC ID 2AO5WROCK250 - SACKit ApS
2AO5WROCK250

Bluetooth True Wireless Headset

Apr 25, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Wireless Charging Power Bank - FCC ID 2AO5W-CHARGEITS - SACKit ApS
2AO5W-CHARGEITS

Wireless Charging Power Bank

Jun 22, 2020

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Stand Wireless Charger - FCC ID 2AO5W-CHARGEITSD - SACKit ApS
2AO5W-CHARGEITSD

Stand Wireless Charger

Jun 20, 2020

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz