FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SACKit ApS/
  3. 2AO5W-MOVE100

2AO5W-MOVE100Bluetooth Speaker

SACKit ApS
Bluetooth Speaker - FCC ID 2AO5W-MOVE100 - SACKit ApS
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Aug 11, 2021
Application Purpose
Original Equipment
Date of Application
Aug 11, 2021
Equipment Note
Bluetooth Speaker
Frequency Range
2402.00000000 - 2480.00000000
Company
SACKit ApS
Country
Denmark

Documents & Files

Select a file to view

Users Manual

โ†—

Cover Letter(s)

โ†—
โ†—

External Photos

โ†—

ID Label/Location Info

Internal Photos

โ†—

RF Exposure Info

โ†—

Test Report

โ†—
โ†—

Test Setup Photos

โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

CTC Laboratories, Inc. 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China Tel: +86-755-27521059 Fax: +86-755-27521011 Http://www.sz-ctc.org.cn Page 1 of 3 External Photographs Page 2 of 3 Page 3 of 3

Internal Photos

CTC Laboratories, Inc. 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China Tel: +86-755-27521059 Fax: +86-755-27521011 Http://www.sz-ctc.org.cn Page 1 of 5 Internal Photographs Page 2 of 5 Page 3 of 5 Page 4 of 5 Page 5 of 5 BT ANT

RF Exposure Info

CTC Laboratories, Inc. 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China Tel: +86-755-27521059 Fax: +86-755-27521011 Http://www.sz-ctc.com.cn CTC Laboratories, Inc. 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the Peopleโ€™s Republic of China : http://yz.cnca.cn RF Exposure Evaluation FCC ID: 2AO5W-MOVE100 According to KDB447498 D01 General RF Exposure Guidance v06, Clause 4.3.1(a) EUT Specification EUT Bluetooth Speaker Model/Type reference: SACKit Move 100 Listed Model(s): SACKit Move 150, BN5K, MOVEit, MOVEit X Frequency band (Operating) BT: 2.402GHz ~ 2.480GHz BLE: 2.402GHz ~ 2.480GHz WLAN: 2.412GHz ~ 2.462GHz Others Device category Portable (<5mm separation) Mobile (>20cm separation) Fixed (>20cm separation) Others ___ Antenna diversity Single antenna Multiple antennas Tx diversity Rx diversity Tx/Rx diversity Antenna gain (Max) 3dBi Limit [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] ยท [โˆšf (GHz) ] โ‰ค 3.0 Where -f (GHz) is the RF channel transmit frequency in GHz -Power and distance are rounded to the nearest mW and mm before calculation -The test exclusions are applicable only when the minimum test separation distance is โ‰ค 50 mm, and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 4.1 f) is applied to determine SAR test exclusion. Page 2 of 2 Report No.: CTC20211221E05 CTC Laboratories, Inc. 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the Peopleโ€™s Republic of China : http://yz.cnca.cn Measurement Result: Type Channel Frequency (MHz) Max. Measured Power (dBm) Tune up Tolerance (dBm) Max. Tune up Power (dBm) Result Limit 8-DPSK 2480 -1.89 -2ยฑ1 -1 0.491 3.0 Note: 1. Calculate by Worst-case mode. 2. For a more detailed features description, please refer to the RF Test Report. **********************THE END**********************

Test Report

CTC Laboratories, Inc. 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China Tel: +86-755-27521059 Fax: +86-755-27521011 Http:// www.sz-ctc.org.cn TEST REPORT Report No. ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท: CTC20211221E04 FCC ID................................: 2AO5W-MOVE100 Applicantยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท: SACKit ApS Addressยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท: Lyngvej 1, Aalborg, 9000 Denmark Manufacturer ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท: SACKit ApS Addressยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท: Lyngvej 1, Aalborg, 9000 Denmark Product Nameยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท: Bluetooth Speaker Trade Markยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท: SACKit Model/Type referenceยทยทยทยทยทยทยทยทยทยทยทยทยท: SACKit Move 100 Listed Model(s) ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท: SACKit Move 150, BN5K, MOVEit, MOVEit X Standardยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of receipt of test sample...: Jun. 21, 2021 Date of testing.......................: Jun. 21, 2021 to Jul. 22, 2021 Date of issue.........................: Jul. 23, 2021 Result.................................: PASS Compiled by: (Printed name+signature) Jim Jiang Supervised by: (Printed name+signature) Miller Ma Approved by: (Printed name+signature) Walter Chen ่‹ฑๆ–‡ๆฃ€ๆต‹็ซ $ $Walter$ Testing Laboratory Name......: CTC Laboratories, Inc. Address...............................: 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China This test report may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product endorsement by CTC. The test results in the report only apply to the tested sample. The test report shall be invalid without all the signatures of testing engineers, reviewer and approver. Any objections must be raised to CTC within 15 days since the date when the report is received. It will not be taken into consideration beyond this limit. The test report merely correspond to the test sample. Page 2 of 86 Report No.: CTC20211221E04 CTC Laboratories, Inc. 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the Peopleโ€™s Republic of China : yz.cnca.cn Table of Contents Page 1. TEST SUMMARY ....................................................................................................................................................... 3 1.1. TEST STANDARDS .......................................................................................................................................................... 3 1.2. REPORT VERSION ......................................................................................................................................................... 3 1.3. TEST DESCRIPTION ........................................................................................................................................................ 3 1.4. TEST FACILITY .............................................................................................................................................................. 4 1.5. MEASUREMENT UNCERTAINTY ........................................................................................................................................ 4 1.6. ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 5 2. GENERAL INFORMATION .......................................................................................................................................... 6 2.1. CLIENT INFORMATION ................................................................................................................................................... 6 2.2. GENERAL DESCRIPTION OF EUT ...................................................................................................................................... 6 2.3. OPERATION STATE ........................................................................................................................................................ 7 2.4. MEASUREMENT INSTRUMENTS LIST ................................................................................................................................. 8 3. TEST ITEM AND RESULTS ........................................................................................................................................ 10 3.1. CONDUCTED EMISSION ................................................................................................................................................ 10 3.2. RADIATED EMISSION ................................................................................................................................................... 15 3.3. BAND EDGE EMISSIONS (RADIATED) .............................................................................................................................. 40 3.4. BAND EDGE AND SPURIOUS EMISSIONS (CONDUCTED) ...................................................................................................... 53 3.5. BANDWIDTH .............................................................................................................................................................. 68 3.6. CHANNEL SEPARATION................................................................................................................................................. 75 3.7. NUMBER OF HOPPING CHANNEL ................................................................................................................................... 79 3.8. DWELL TIME ....................................................................................................โ€ฆ

Text truncated - open the document above for the full version.

Test Report

Page 53 of 86 Report No.: CTC20211221E04 CTC Laboratories, Inc. 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the Peopleโ€™s Republic of China : yz.cnca.cn 3.4. Band edge and Spurious Emissions (Conducted) Limit FCC CFR Title 47 Part 15 Subpart C Section 15.247 (d): In any 100 kHz bandwidth outside the frequency band in which the spread spectrum intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement. Test Configuration Test Procedure 1. The transmitter output was connected to the spectrum analyzer through an attenuator, the path loss was compensated to the results for each measurement. 2. Set to the maximum power setting and enable the EUT transmit continuously 3. Use the following spectrum analyzer settings: RBW = 100 kHz, VBW โ‰ฅ RBW, scan up through 10 th harmonic. Sweep = auto, Detector function = peak, Trace = max hold 4. Measure and record the results in the test report. Test Mode Please refer to the clause 2.3. Test Result (1) Band edge Conducted Test Test Mode Antenna ChName Frequency (MHz) RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5 Ant1 Low 2402 -4.36 -45.79 <=-24.36 PASS High 2480 -3.53 -51.89 <=-23.53 PASS Low Hop_2402 -5.51 -56.48 -25.51 PASS High Hop_2480 -4.01 -56.35 -24.01 PASS 2DH5 Ant1 Low 2402 -4.38 -45.70 <=-24.38 PASS High 2480 -4.62 -51.16 <=-24.62 PASS Low Hop_2402 -8.64 -57.63 -28.64 PASS High Hop_2480 -5.39 -56.82 -25.39 PASS 3DH5 Ant1 Low 2402 -4.37 -45.90 <=-24.37 PASS High 2480 -3.37 -55.68 <=-23.37 PASS Low Hop_2402 -5.49 -57.44 -25.49 PASS High Hop_2480 -3.42 -57.76 -23.42 PASS Page 54 of 86 Report No.: CTC20211221E04 CTC Laboratories, Inc. 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the Peopleโ€™s Republic of China : yz.cnca.cn Test Graphs: DH5_Ant1_Low_2402 DH5_Ant1_High_2480 DH5_Ant1_Low_Hop_2402 DH5_Ant1_High_Hop_2480 Page 55 of 86 Report No.: CTC20211221E04 CTC Laboratories, Inc. 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the Peopleโ€™s Republic of China : yz.cnca.cn 2DH5_Ant1_Low_2402 2DH5_Ant1_High_2480 2DH5_Ant1_Low_Hop_2402 Page 56 of 86 Report No.: CTC20211221E04 CTC Laboratories, Inc. 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the Peopleโ€™s Republic of China : yz.cnca.cn 2DH5_Ant1_High_Hop_2480 3DH5_Ant1_Low_2402 3DH5_Ant1_High_2480 Page 57 of 86 Report No.: CTC20211221E04 CTC Laboratories, Inc. 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the Peopleโ€™s Republic of China : yz.cnca.cn 3DH5_Ant1_Low_Hop_2402 3DH5_Ant1_High_Hop_2480 Page 58 of 86 Report No.: CTC20211221E04 CTC Laboratories, Inc. 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the Peopleโ€™s Republic of China : yz.cnca.cn (2) Conducted Spurious Emissions Test Test Mode Antenna Frequency (MHz) FreqRange [MHz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5 Ant1 2402 Reference -4.45 -4.45 --- PASS 30~1000 30~1000 -71.04 <=-24.45 PASS 1000~26500 1000~26500 -46.40 <=-24.45 PASS 2441 Reference -3.72 -3.72 --- PASS 30~1000 30~1000 -70.41 <=-23.72 PASS 1000~26500 1000~26500 -46.06 <=-23.72 PASS 2480 Reference -3.33 -3.33 --- PASS 30~1000 30~1000 -69.88 <=-23.33 PASS 1000~26500 1000~26500 -45.96 <=-23.33 PASS 2DH5 Ant1 2402 Reference -4.51 -4.51 --- PASS 30~1000 30~1000 -70.93 <=-24.51 PASS 1000~26500 1000~26500 -45.81 <=-24.51 PASS 2441 Reference -3.77 -3.77 --- PASS 30~1000 30~1000 -69.61 <=-23.77 PASS 1000~26500 1000~26500 -46.39 <=-23.77 PASS 2480 Reference -3.38 -3.38 --- PASS 30~1000 30~1000 -69.98 <=-23.38 PASS 1000~26500 1000~26500 -46.88 <=-23.38 PASS 3DH5 Ant1 2402 Reference -4.46 -4.46 --- PASS 30~1000 30~1000 -70.72 <=-24.46 PASS 1000~26500 1000~26500 -46.27 <=-24.46 PASS 2441 Reference -3.81 -3.81 --- PASS 30~1000 30~1000 -70.99 <=-23.81 PASS 1000~26500 1000~26500 -46.68 <=-23.81 PASS 2480 Reference -3.33 -3.33 --- PASS 30~1000 30~1000 -70.90 <=-23.33 PASS 1000~26500 1000~26500 -46.94 <=-23.33 PASS Page 59 of 86 Report No.: CTC20211221E04 CTC Laboratories, Inc. 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the Peopleโ€™s Republic of China : yz.cnca.cn Test Graphs: DH5_Ant1_2402_0~Reference DH5_Ant1_2402_30~1000 DH5_Ant1_2402_1000~26500 DH5_Ant1_2441_0~Reference Page 60 of 86 Report No.: CTC20211221E04 CTC Laboratories, Inc. 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tโ€ฆ

Text truncated - open the document above for the full version.

Test Setup Photos

CTC Laboratories, Inc. 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China Tel: +86-755-27521059 Fax: +86-755-27521011 Http://www.sz-ctc.org.cn Page 1 of 2 Radiated Measurements 30-1000MHz Above 1GHz Page 2 of 2 Conducted Measurements

Contact Information

Applicant

Peter Rasmussen
[email protected]+4530613631Fax: N/A

Test Firm

CTC Laboratories, Inc.Totti Zhao
[email protected]+8675527521059

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz600.00 ยตW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.

Other Applications from SACKit ApS

Wireless Charging Pad - FCC ID 2AO5W-CHARGE50 - SACKit ApS
2AO5W-CHARGE50

Wireless Charging Pad

Jun 28, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Bluetooth True Wireless Headset - FCC ID 2AO5WROCK250 - SACKit ApS
2AO5WROCK250

Bluetooth True Wireless Headset

Apr 25, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Dual Wireless Charging Pad - FCC ID 2AO5W-CHARGEITDD - SACKit ApS
2AO5W-CHARGEITDD

Dual Wireless Charging Pad

Jul 22, 2020

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Wireless Charging Power Bank - FCC ID 2AO5W-CHARGEITS - SACKit ApS
2AO5W-CHARGEITS

Wireless Charging Power Bank

Jun 22, 2020

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Stand Wireless Charger - FCC ID 2AO5W-CHARGEITSD - SACKit ApS
2AO5W-CHARGEITSD

Stand Wireless Charger

Jun 20, 2020

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz