FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shanghai Imilab Technology Co.,Ltd./
  3. 2APA9-CMSXJ115A

2APA9-CMSXJ115AIMILAB EC6 Panorama

Shanghai Imilab Technology Co.,Ltd.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 03, 2024
Application Purpose
Original Equipment
Date of Application
Sep 03, 2024
Equipment Note
IMILAB EC6 Panorama
Frequency Range
2412.00000000 - 2462.00000000
Company
Shanghai Imilab Technology Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

ShanghaiImilabTechnologyCo.,Ltd. Room001A,Floor11,Block1,No.588ZixingRoad,MinhangDistrict,Shanghai,China FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:Aug.26,2024 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2APA9-CMSXJ115A FRN:0027364421 [ShanghaiImilabTechnologyCo.,Ltd.](“theapplicant”)certifiesthattheequipmentforwhich authorizationissoughtisnot“covered”equipmentprohibitedfromreceivinganequipment authorizationpursuanttosection2.903oftheFCCrules. Sincerely, (Applicantsignature) (yansiyang)

Attestation Statements

Shanghai Imilab Technology Co., Ltd. Room 001A, Floor 11, Block 1, No. 588 Zixing Road, Minhang District, Shanghai, China Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Aug. 26, 2024 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2APA9-CMSXJ115A FRN: 0027364421 [Shanghai Imilab Technology Co., Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (yan siyang)

Attestation Statements

[ShanghaiImilabTechnologyCo.,Ltd.] [Room001A,Floor11,Block1,No.588ZixingRoad,MinhangDistrict] [Shanghai] [China] Date:Aug.26,2024 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 FCCID:2APA9-CMSXJ115A USAgent–AttestationStatement/Part2.911(d)(7) [ShanghaiImilabTechnologyCo.,Ltd.]certifies,thatasof[Aug.26,2024],wehavedesignated FCCUSAgent,LLCtoacceptserviceofprocessonourbehalfforFCCID:2APA9-CMSXJ115A. [ShanghaiImilabTechnologyCo.,Ltd.],acceptstomaintainanagentofserviceofprocessinthe UnitedStatesfornolessthanoneyearaftereitherthegranteehaspermanentlyterminatedall marketingandimportationoftheapplicableequipmentwithintheU.S.,ortheconclusionofany Commission-relatedadministrativeorjudicialproceedinginvolvingtheequipment,whicheveris later. FCCUSAgent,LLC,acceptsasofthedateofthefilingofthisapplication,theobligationofbeing thedesignatedagentforthepurposeofacceptingserviceofprocessonbehalfof[Shanghai ImilabTechnologyCo.,Ltd.]forFCCID:2APA9-CMSXJ115A. DesignatedAgentInformation: CompanyName:FCCUSAgent,LLC FRN:0033402884 Address:3722IllinoisAvenue,SaintCharles,IL,60174,USA ContactPerson:TimPayne Phone:708-571-3148 Email:[email protected] Sincerely, Company:[ShanghaiImilabTechnologyCo., Ltd.] FRN:0027364421 DesignatedAgent:FCCUSAgent,LLC CompanyRepresentative:[yansiyang] Tel:+86-021-54201111 Email:[email protected] DesignatedAgentRepresentative:TimPayne Signature:Signature:

Cover Letter(s)

ShanghaiImilabTechnologyCo.,Ltd. Room001A,Floor11,Block1,No.588ZixingRoad,MinhangDistrict,Shanghai,China OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:Aug.26,2024 Subject;RequestforConfidentiality FCCID:2APA9-CMSXJ115A ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram OperationalDescription PartsList Tune-upProcedure Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:yansiyang Title:GeneralManager

Cover Letter(s)

Shanghai Imilab Technology Co., Ltd. Room 001A, Floor 11, Block 1, No. 588 Zixing Road, Minhang District, Shanghai, China Letter of Authorization Company: Shanghai Imilab Technology Co., Ltd. Address: Room 001A, Floor 11, Block 1, No. 588 Zixing Road, Minhang District, Shanghai, China Product Name: IMILAB EC6 Panorama Model Number(s): CMSXJ115A Product Description: IMILAB EC6 Panorama We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: Aug. 26, 2024 Name: yan siyang Title: General Manager Company: Shanghai Imilab Technology Co., Ltd.

ID Label/Location Info

FCC ID Label Location 40mm*20mm

RF Exposure Info

Page 1 of 10 RF Exposure Report Report No.: AGC05877240702FH01 FCC ID : 2APA9-CMSXJ115A APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : IMILAB EC6 Panorama BRAND NAME : imilab, MODEL NAME : CMSXJ115A APPLICANT : Shanghai Imilab Technology Co., Ltd. DATE OF ISSUE : Aug. 26, 2024 STANDARD(S) : FCC Part 2 Subpart J §2.1091 REPORT VERSION : V1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd Report No.: AGC05877240702FH01 Page 2 of 10 Report Revise Record Report Version Revise Time Issued Date Valid Version Notes V1.0 / Aug. 26, 2024 Valid Initial Release Report No.: AGC05877240702FH01 Page 3 of 10 Table of Contents 1. General Information ........................................................................................................................................ 4 2. Product Information ........................................................................................................................................ 5 2.1 Product Technical Description ................................................................................................................... 5 3. Test Environment ............................................................................................................................................ 6 3.1 Address Of The Test Laboratory ............................................................................................................... 6 3.2 Test Facility ................................................................................................................................................ 6 3.3 Environmental Conditions ......................................................................................................................... 7 4. Portable Device Evaluation Method and Limit ............................................................................................. 8 5. Mobile Device Evaluation Method and Limit ................................................................................................ 9 6. Measurement Results ................................................................................................................................... 10 7. Measurement Evaluation .............................................................................................................................. 10 Report No.: AGC05877240702FH01 Page 4 of 10 1. General Information Applicant Shanghai Imilab Technology Co., Ltd. Address Room 001A, Floor 11, Block 1, No. 588 Zixing Road, Minhang District, Shanghai, China Manufacturer Shanghai Imilab Technology Co., Ltd. Address Room 001A, Floor 11, Block 1, No. 588 Zixing Road, Minhang District, Shanghai, China Factory N/A Address N/A Product Designation IMILAB EC6 Panorama Brand Name imilab, Test Model CMSXJ115A Series Model(s) N/A Difference Description N/A Date of receipt of test item Jul. 23, 2024 Date of Test Jul. 23, 2024 - Aug. 26, 2024 Deviation from Standard No any deviation from the test method Condition of Test Sample Normal Test Result Pass Test Report Form No AGCER-FCC-RF Exposure-V1 Note: The test results of this report relate only to the tested sample identified in this report. Prepared By Cici Li (Project Engineer) Aug. 26, 2024 Reviewed By Calvin Liu (Reviewer) Aug. 26, 2024 Approved By Max Zhang (Authorized Officer) Aug. 26, 2024 Report No.: AGC05877240702FH01 Page 5 of 10 2. Product Information 2.1 Product Technical Description Frequency Band (Operating) WLAN: 2.412GHz ~ 2.462GHz WLAN: 5.18GHz ~ 5.32GHz / 5.50GHz ~ 5.70GHz WLAN: 5.745GHz ~ 5825GHz Bluetooth: 2.402GHz ~ 2.480GHz Other: Hardware Version LSAM113C1-1 Software Version 5.3.1_0501 Modulation Type 802.11b:(DQPSK, DBPSK, CCK) DSSS 802.11g/n:(64-QAM,16-QAM, QPSK, BPSK) OFDM 802.11ax:(1024-QAM,256-QAM,64-QAM,16-QAM,QPSK,BPSK)OFDMA Device Category Portable (<20cm separation) Mobile (>20cm separation) Others: Antenna Diversity Single antenna Multiple antennas Tx diversity Rx diversity Tx/Rx diversity Antenna Designation PCB Antenna Antenna Gain 1.5dBi Minimum Assessment Distance 20cm Evaluation Applied MPE Evaluation SAR Evaluation Report No.: AGC05877240702FH01 Page 6 of 10 3. Test Environment 3.1 Address Of The Test Laboratory Laboratory: Attestation of Global Compliance (Shenzhen) Co., Ltd. Address: 1-2/F, Building 19, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China 3.2 Test Facility The test facility is recognized, certified, or accredited by the following organizations: CNAS-Lab Code: L5488 Attestation of Global Compliance (Shenzhen) Co., Ltd. has been assessed and proved to follow CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC17025: 2017 General Requirements for the Competence of Testing and Calibration Laboratories.) A2LA-Lab Cert. No.: 5054.02 Attestation of Global Compliance (Shenzhen) Co., Ltd. EMC Laboratory has been accredited by A2LA for technical competence in the field of electrical testing, and proved to follow ISO/IEC 17025: 2017 General Requirements for the Competence of Testing and Calibration Laboratories and any additional program requirements in the identified field of testing. FCC-Registration No.: 975832 Attestation of Global Compliance (Shenzhen) Co., Ltd. EMC Laboratory has been registered and fully described in a report filed with the FCC (Federal Communications Commission). The acceptance letter from the FCC is maintained in our files with Registration 975832. IC-Registration No.: 24842(CAB identifier: CN0063) Attestation of Global Compliance (Shenzhen) Co., Ltd. EMC Laboratory has been registered and fully described in a report filed with the Certification and Engineering Bureau of Industry Canada. The acceptance letter from the IC is maintained in our files with Registration 24842. Report No.: AGC05877240702FH01 Page 7 of 10 3.3 Environmental Conditions Normal Conditions Temperature range (°C) 15 - 35 Relative humidity range 20 % -…

Text truncated - open the document above for the full version.

Test Report

Shanghai Chuangmi Technology Co.,Ltd. Shanghai Chuangmi Technology Co., Ltd. Integral Antenna Part Description ManufacturerKunshan Yunzhihong Electronic Technology Co. LTD.Description:CM0359-W03-00 Manufacturer Address:No.399, Jujin Road, Zhangpu Town, Kunshan City, Jiangsu Province Product Name: IMI IPC115 ACE1,WIFI AntennaProject:IPC115 Antenna type:Built in antenna PCB+cable Part No.:5022AA013622 Attachments: □ Specification □ Drawing □ Sample □ RoHS Report □ CPK Report □ FAI Report □ Reliability Report □ RoHS Questionnaire □ QC Flow Chart □ Material Verification Sheet □ Packing Content □ Safety Report * ROHS VendorDesignCheck Approval: Technology CheckMechanicalHardwareID Sourcing SoftwareKeypartEngineering SQE Project ManagerProduct ManagerCustomer Final CheckQuality PlanningRohs Status ■ RoHS □ No n-RoHS Approval condition □ Approved □ Reject Approval condition □ Conditional Approved Conditions: □ Temporary ApprovedLimited________Pcs for purchasing Approval byRD Leader(Technology Director) Quality Director * Audit by Technology Director or Qunality director on the conditions of special approval Distribute □ IQC □ hardware □ ME □ Software □ Components □ ID □ Vendor □ Customer □ outsoucing □ Engineering □ SQE □ Others ________ Shanghai Chuangmi Technology Co., Ltd. Content 1 COVER 2 DIRECTORY 3 SPEC 4Full size measurement report 5 Antenna Performance Report 6 Antenna test configuation Full Dimensions Report VendorMaterialpcb+cablePart No. 5022AA013622 Tool NumberCav. NumberUnit Comments CHUANG MI Model N/A Part Name IMI IPC115ACE1, WIFI Antenna N/A N/A Date 2024.06.28 ReversionA0 Measured Dimensions% Tolerance UsedDispositionAcceptance variance D I M . # DIMENSION D R A W I N G Z O N E + TOL.- TOL. N O T E SAMPLE 1SAMPLE 2SAMPLE 3SAMPLE 4SAMPLE 5UPPERLOWER 0 % - 2 5 % 2 5 % - 5 0 % 5 0 % - 7 5 % 7 5 % - 1 0 0 % 1 0 0 % + R e - M e a s u r e A c c e p t F i x T o o l A c c e p t W i t h V a r i a n c e DIMENSION+ TOL.- TOL. 1 50.00A30.30 0.30 50.2050.1949.8649.9850.0967%47%X 2 18.00B20.30 0.30 18.0318.2217.8618.1818.0673%47%X 3 49.00A52.00 2.00 50.0050.0049.0048.0050.0050%50%X 4 1.13B50.100.101.161.181.111.121.1450%20%XX 5 0.80C20.100.100.830.850.830.820.8660%0%X 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 INCHESMILLIMETERS Reliability test report Customer Chuangmi Written By WENFENG Orig. Date 2024/6/29 Part Number 5022AA013622 Revised By lanxuehua Revised Date 2024/6/29 Description1 IMI IPC115ACE1, WIFI Antenna Approved By panxinpu Approved Date 2024/6/29 Test date:2024/6/28The experimental code:2024062802 The experimental method:Salt spray testThe experimental standard:Box test sample The name of the5022AA013622 The thicknes s of thecoati ng NIAU The materialPCB+CABLE Appearance before experiment okQuantity5 PCS Experimental conditions The experimental time:20024/4/16,15:00 ~20024/4/18,15:00 Spray time:48 hoursMoisturizing time:48 hours Laboratory temperature:35°C±2°CPressure drum temperature:46°C±2°C Laboratory relative humidity:65%-75 % Atmospheric pressure:101-02KPA NACL concentration:5%±0.5%PH:6.5-7.2(neutral) The experiment described Post-experiment appearance Appearance normal, no obvious corrosion phenomenon Appearance after removal of corrosion products Appearance of the normal The experimental results OK note Approved by the :maruiguoaudit:sunnyTesting personne:tangyinglong Antenna Performance Report Customer Chuangmi Written By WENFENG Orig. Date 2024/6/29 Part Number 5022AA013622 Revised By Xuehua Lan Revised Date 2024/6/29 Description1 IMI IPC115ACE1, WIFI Antenna Approved By Sinfo Pan Approved date 2024/6/29 Antenna Test Configuation Customer Chuangmi Written By WENFENG Orig. Date 2024/6/29 Part Number 5022AA013622 Revised By Xuehua Lan Revised Date 2024/6/29 Description1 IMI IPC115ACE1, WIFI Antenna Approved By Sinfo Pan Approved date 2024/6/29

Test Report

Page 1 of 88 FCC Test Report Report No.: AGC05877240702FR01 FCC ID : 2APA9-CMSXJ115A APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : IMILAB EC6 Panorama BRAND NAME : imilab, MODEL NAME : CMSXJ115A APPLICANT : Shanghai Imilab Technology Co., Ltd. DATE OF ISSUE : Aug. 26, 2024 STANDARD(S) : FCC Part 15 Subpart C §15.247 REPORT VERSION : V1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd Report No.: AGC05877240702FR01 Page 2 of 88 Report Revise Record Report Version Revise Time Issued Date Valid Version Notes V1.0 / Aug. 26, 2024 Valid Initial Release Report No.: AGC05877240702FR01 Page 3 of 88 Table of Contents 1. General Information ........................................................................................................................................ 5 2. Product Information ........................................................................................................................................ 6 2.1 Product Technical Description ................................................................................................................... 6 2.2 Table of Carrier Frequency ........................................................................................................................ 7 2.3 IEEE 802.11n Modulation Scheme ........................................................................................................... 8 2.4 Related Submittal(S) / Grant (S) ............................................................................................................... 9 2.5 Test Methodology ...................................................................................................................................... 9 2.6 Special Accessories .................................................................................................................................. 9 2.7 Equipment Modifications ........................................................................................................................... 9 2.8 Antenna Requirement................................................................................................................................ 9 2.9 Description of Test Software ................................................................................................................... 10 3. Test Environment .......................................................................................................................................... 11 3.1 Address of The Test Laboratory .............................................................................................................. 11 3.2 Test Facility .............................................................................................................................................. 11 3.3 Environmental Conditions ....................................................................................................................... 12 3.4 Measurement Uncertainty ....................................................................................................................... 12 3.5 List of Equipment Used ........................................................................................................................... 13 4.System Test Configuration ............................................................................................................................ 15 4.1 EUT Configuration ................................................................................................................................... 15 4.2 EUT Exercise ........................................................................................................................................... 15 4.3 Configuration of Tested System .............................................................................................................. 15 4.4 Equipment Used in Tested System ......................................................................................................... 15 4.5 Summary of Test Results ........................................................................................................................ 16 5. Description of Test Modes ........................................................................................................................... 17 6. Duty Cycle Measurement ............................................................................................................................. 18 7. RF Output Power Measurement .................................................................................................................. 20 7.1 Provisions Applicable .............................................................................................................................. 20 7.2 Measurement Procedure ......................................................................................................................... 20 7.3 Measurement Setup (Block Diagram of Configuration) .......................................................................... 20 7.4 Measurement Result ............................................................................................................................... 21 8. 6dB Bandwidth Measurement ...................................................................................................................... 22 8.1 Provisions Applicable .............................................................................................................................. 22 8.2 Measurement Procedure ......................................................................................................................... 22 8.3 Measurement Setup (Block Diagram of Configuration) .......................................................................... 22 8.4 Measurement Result ............................................................................................................................... 23 9. Power S…

Text truncated - open the document above for the full version.

Test Report

Report No.: AGC05877240702FR01 Page 69 of 88 Band Edge Emission Test Results for Restricted Bands EUT Name IMILAB EC6 Panorama Model Name CMSXJ115A Temperature 24.7°C Relative Humidity 58 % Pressure 960hPa Test Voltage Normal Voltage Test Mode Mode 1 Antenna Polarity Vertical Test Graph for Peak Measurement Test Graph for Average Measurement RESULT: Pass Report No.: AGC05877240702FR01 Page 70 of 88 Band Edge Emission Test Results for Restricted Bands EUT Name IMILAB EC6 Panorama Model Name CMSXJ115A Temperature 24.7°C Relative Humidity 58 % Pressure 960hPa Test Voltage Normal Voltage Test Mode Mode 3 Antenna Polarity Horizontal Test Graph for Peak Measurement Test Graph for Average Measurement RESULT: Pass Report No.: AGC05877240702FR01 Page 71 of 88 Band Edge Emission Test Results for Restricted Bands EUT Name IMILAB EC6 Panorama Model Name CMSXJ115A Temperature 24.7°C Relative Humidity 58 % Pressure 960hPa Test Voltage Normal Voltage Test Mode Mode 3 Antenna Polarity Vertical Test Graph for Peak Measurement Test Graph for Average Measurement RESULT: Pass Report No.: AGC05877240702FR01 Page 72 of 88 Band Edge Emission Test Results for Restricted Bands EUT Name IMILAB EC6 Panorama Model Name CMSXJ115A Temperature 24.7°C Relative Humidity 58 % Pressure 960hPa Test Voltage Normal Voltage Test Mode Mode 4 Antenna Polarity Horizontal Test Graph for Peak Measurement Test Graph for Average Measurement RESULT: Pass Report No.: AGC05877240702FR01 Page 73 of 88 Band Edge Emission Test Results for Restricted Bands EUT Name IMILAB EC6 Panorama Model Name CMSXJ115A Temperature 24.7°C Relative Humidity 58 % Pressure 960hPa Test Voltage Normal Voltage Test Mode Mode 4 Antenna Polarity Vertical Test Graph for Peak Measurement Test Graph for Average Measurement RESULT: Pass Report No.: AGC05877240702FR01 Page 74 of 88 Band Edge Emission Test Results for Restricted Bands EUT Name IMILAB EC6 Panorama Model Name CMSXJ115A Temperature 24.7°C Relative Humidity 58 % Pressure 960hPa Test Voltage Normal Voltage Test Mode Mode 6 Antenna Polarity Horizontal Test Graph for Peak Measurement Test Graph for Average Measurement RESULT: Pass Report No.: AGC05877240702FR01 Page 75 of 88 Band Edge Emission Test Results for Restricted Bands EUT Name IMILAB EC6 Panorama Model Name CMSXJ115A Temperature 24.7°C Relative Humidity 58 % Pressure 960hPa Test Voltage Normal Voltage Test Mode Mode 6 Antenna Polarity Vertical Test Graph for Peak Measurement Test Graph for Average Measurement RESULT: Pass Report No.: AGC05877240702FR01 Page 76 of 88 Band Edge Emission Test Results for Restricted Bands EUT Name IMILAB EC6 Panorama Model Name CMSXJ115A Temperature 24.7°C Relative Humidity 58 % Pressure 960hPa Test Voltage Normal Voltage Test Mode Mode 7 Antenna Polarity Horizontal Test Graph for Peak Measurement Test Graph for Average Measurement RESULT: Pass Report No.: AGC05877240702FR01 Page 77 of 88 Band Edge Emission Test Results for Restricted Bands EUT Name IMILAB EC6 Panorama Model Name CMSXJ115A Temperature 24.7°C Relative Humidity 58 % Pressure 960hPa Test Voltage Normal Voltage Test Mode Mode 7 Antenna Polarity Vertical Test Graph for Peak Measurement Test Graph for Average Measurement RESULT: Pass Report No.: AGC05877240702FR01 Page 78 of 88 Band Edge Emission Test Results for Restricted Bands EUT Name IMILAB EC6 Panorama Model Name CMSXJ115A Temperature 24.7°C Relative Humidity 58 % Pressure 960hPa Test Voltage Normal Voltage Test Mode Mode 9 Antenna Polarity Horizontal Test Graph for Peak Measurement Test Graph for Average Measurement RESULT: Pass Report No.: AGC05877240702FR01 Page 79 of 88 Band Edge Emission Test Results for Restricted Bands EUT Name IMILAB EC6 Panorama Model Name CMSXJ115A Temperature 24.7°C Relative Humidity 58 % Pressure 960hPa Test Voltage Normal Voltage Test Mode Mode 9 Antenna Polarity Vertical Test Graph for Peak Measurement Test Graph for Average Measurement RESULT: Pass Report No.: AGC05877240702FR01 Page 80 of 88 Band Edge Emission Test Results for Restricted Bands EUT Name IMILAB EC6 Panorama Model Name CMSXJ115A Temperature 24.7°C Relative Humidity 58 % Pressure 960hPa Test Voltage Normal Voltage Test Mode Mode 10 Antenna Polarity Horizontal Test Graph for Peak Measurement Test Graph for Average Measurement RESULT: Pass Report No.: AGC05877240702FR01 Page 81 of 88 Band Edge Emission Test Results for Restricted Bands EUT Name IMILAB EC6 Panorama Model Name CMSXJ115A Temperature 24.7°C Relative Humidity 58 % Pressure 960hPa Test Voltage Normal Voltage Test Mode Mode 10 Antenna Polarity Vertical Test Graph for Peak Measurement Test Graph for Average Measurement RESULT: Pass Report No.: AGC05877240702FR01 Page 82 of 88 Band Edge Emission Test Results for Restricted Bands EUT Name IMILAB EC6 Panorama Model Name CMSXJ115A Temperature 24.7°C Relative Humidity 58 % Pressure 960hPa Test Voltage Normal Voltage Test Mode Mode 12 Antenna Polarity Horizontal Test Graph for Peak Measurement Test Graph for Average Measurement RESULT: Pass Report No.: AGC05877240702FR01 Page 83 of 88 Band Edge Emission Test Results for Restricted Bands EUT Name IMILAB EC6 Panorama Model Name CMSXJ115A Temperature 24.7°C Relative Humidity 58 % Pressure 960hPa Test Voltage Normal Voltage Test Mode Mode 12 Antenna Polarity Vertical Test Graph for Peak Measurement Test Graph for Average Measurement RESULT: Pass Note: The factor had been edited in the “Input Correction” of the Spectrum Analyzer. Report No.: AGC05877240702FR01 Page 84 of 88 12. AC Power Line Conducted Emission 12.1 Measurement Limits Frequency Maximum RF Line Voltage Q.P (dBμV) Average (dBμV) 150kHz~500kHz 66-56 56-46 500kHz~5MHz 56 46 5MHz~30MHz 60 50 Note: 1. The lower limit shall apply at the transition frequency. 2. The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz. 12.2 Block Diagram of Line Conducted Emission Test Report No.: AGC05877240702FR01 Page 85 of 88 12.3 Preliminary Procedure of Line Conducted Emiss…

Text truncated - open the document above for the full version.

Contact Information

Applicant

yan siyang
[email protected]+86-021-54201111Fax: -

Technical Contact

Shanghai Imilab Technology Co.,Ltd.
[email protected]

China

Test Firm

Attestation of Global Compliance (Shenzhen) Co., LDoris Li
[email protected]+86-755-25234088

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz80.20 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Other Applications from Shanghai Imilab Technology Co.,Ltd.

WiFi Smart Camera - FCC ID 2APA9-A331D - Shanghai Imilab Technology Co.,Ltd.
2APA9-A331D

WiFi Smart Camera

Aug 12, 2026

Equipment Class

DTS - Digital Transmission System
IMILAB C21 - FCC ID 2APA9-CMSXJ56F - Shanghai Imilab Technology Co.,Ltd.
2APA9-CMSXJ56F

IMILAB C21

Nov 19, 2023

Equipment Class

DTS - Digital Transmission System
IMILAB Doorbell Hub - FCC ID 2APA9-CMSXJ33B - Shanghai Imilab Technology Co.,Ltd.
2APA9-CMSXJ33B

IMILAB Doorbell Hub

Apr 28, 2022

Equipment Class

DTS - Digital Transmission System
IMILAB Video Doorbell - FCC ID 2APA9-CMSXJ33A - Shanghai Imilab Technology Co.,Ltd.
2APA9-CMSXJ33A

IMILAB Video Doorbell

Apr 24, 2022

Equipment Class

DTS - Digital Transmission System
IMILAB EC5 Floodlight Camera - FCC ID 2APA9-CMSXJ55A - Shanghai Imilab Technology Co.,Ltd.
2APA9-CMSXJ55A

IMILAB EC5 Floodlight Camera

Apr 13, 2022

Equipment Class

DTS - Digital Transmission System