FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Swimmersive Co./
  3. 2APZQ-ZYGO

2APZQ-ZYGOUnderwater communication radio

Swimmersive Co.
Underwater communication radio - FCC ID 2APZQ-ZYGO - Swimmersive Co.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jun 04, 2020
Application Purpose
Original Equipment
Date of Application
Jun 04, 2020
Equipment Note
Underwater communication radio
Frequency Range
2402.00000000 - 2479.00000000
Company
Swimmersive Co.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

LIMITED WARRANTY Term: Zygo is warranted to be free from defects in materials or workmanship as provided below for 1 year from the date of purchase. Terms: Pursuant to this Limited Warranty, Zygo will, at its option, (i) repair the product using new or refurbished parts or (ii) replace the product with a new or refurbished product. For purposes of this Limited Warranty, “refurbished” means a product or part that has been returned to its original specifica- tions. In the event of a defect, these are your exclusive remedies. This Limited Warranty only covers product issues caused by defects in material or workmanship during ordinary consumer use and in accordance with specifications provided by Zygo, it does not cover product issues caused by any other reason, including but not limited to product issues due to the following: (i) cosmetic damage, such as scratches, nicks or paint damage, (ii) damage caused by accident, abuse, misuse, flood, fire or other acts of nature or external causes, (iii) damage caused by service performed by anyone who is not an authorized service provider of Zygo; (iv) damage to a product that has been modi- fied or altered without the written permission of Zygo, (v) damage to a product that has broken its waterproof seal, or (vi) any other misuse. In addition, Zygo reserves the right to refuse warranty claims against products or services that are obtained and/ or used in contravention of the laws of any country in which Zygo is used and/or purchased. THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES EXPRESS, IMPLIED, OR STATUTORY, INCLUDING ANY LIABILITY ARISING UNDER ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, STATUTORY OR OTHERWISE. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, WHICH MAY VARY FROM STATE TO STATE. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ANY IMPLIED WARRANTY OR CONDITION OF MERCHANTABI- LITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. IN NO EVENT SHALL ZYGO BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, WHETH- ER RESULTING FROM THE USE, MISUSE OR INABILITY TO USE THIS PRODUCT OR FROM DEFECTS IN THE PRODUCT. SOME STATES DO NOT ALLOW THE EXCLUSION OF INCIDEN- TAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITA- TIONS MAY NOT APPLY TO YOU. COPYRIGHT & TRADEMARK INFORMATION © Swimmersive Co. 2017 dba Zygo are trademarked. All other company and product names mentioned may be trademarks of their respective companies. Mention of third-party products is for informational purposes only and does not constitute an endorsement or recommendation. Zygo assumes no responsibili- ty with regard to the performance of products mentioned. SERVICE To obtain warranty service, call Zygo for shipping instructions and a return material authorization (RMA) tracking number. Securely pack the device and a copy of the original sales receipt, gift receipt, packing list and/or other valid proof of purchase (including purchaser receipt and/or gift receipt) which is required as the proof of purchase for warranty repairs. CUSTOMER SUPPORT US: +1-818-445-2293, 7 days, 6am-6pm PST UK: +44-0743-745-5790, 7 days, 6am-6pm GMT Email [email protected] Visit shopzygo.com for additional support COMPANY ADDRESS 16854 Mooncrest Dr. Encino, CA 91436 SAFETY INFORMATION This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. This device complies with Part 15 of the FCC rules and with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploita- tion est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communi- cations. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. Your device is a radio transmitter and receiver. It is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission of the U.S. Government. The FCC has established criteria for the amount of radio frequency energy various products may produce depending on their intended usage. This product has been evaluated and found to comply with the FCC’s exposure criteria. For body worn operation, the FCC RF exposure guidelines were also met when used with the accessories supplied or designed for this product. Use of other accessories may not ensure compliance with FCC RF exposure guidelines and should be avoided. Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this device. This device must not be co-located with other transmitters. The installer of this radio equipme…

Text truncated - open the document above for the full version.

Cover Letter(s)

TCB_F_10.01, Rev. 3, Effective 2018-09-24 Page 1 of 5 TÜV SÜD America, Inc. 10 Centennial Drive, Peabody, MA 01960, USA TCB FORM 731 Section 1: Applicant Information Applicant’s complete, legal business name: Applicant’s FCC Registration Number (FRN): Swimmersive Co. 0027573781 Address Line 1: 16854 Mooncrest Dr. Address Line 2: City: State: Country: Zip/Postal Code: Encino CA USA 91436 Applicant Contact Name: Sheera Goren (Must be the same as the FCC Grantee Contact listed in the FCC database. The name in the FCC Database will be listed on the Grant.) https://apps.fcc.gov/oetcf/eas/reports/GranteeSearch.cfm Title: Phone #: (818) 445-2293 Fax #: Email: [email protected] Section 2: FCC ID Information Grantee Code: Equipment Product Code (14 Characters Maximum): 2APZQ -ZYGO Section 3: Application Contact: (If different from Section 1). The original Grant and Invoice as well as all questions regarding the application will be sent to this contact. Company Name: Contact Name: Title: Address Line 1: Address Line 2: City: State: Country: Zip/Postal Code: Phone #: Fax #: Email: Section 4: Main Test Lab Used for Data Measurements: (If different from Section 3) Company Name: Professional Testing (EMI) Inc. FCC Registered Test Lab Number: 459644 Section 5: Confidentiality Request: Does this application include a request for Short-Term confidentiality for any portion(s) of the data contained in this application pursuant to KDB 726920 D01? SHORT-TERM request: YES NO If YES specify release date (MM/DD/YYYY): Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR 0.459 of the Commission Rules? PERMANENT request: YES NO Section 6: Grant Deferral Does the applicant request that the Commission defer grant of this application pursuant to 47 CFR § 0.457(d)(1)(ii)? YES NO If so, specify the requested grant deferral date (MM/DD/YYYY format): TCB_F_10.01, Rev. 3, Effective 2018-09-24 Page 2 of 5 TÜV SÜD America, Inc. 10 Centennial Drive, Peabody, MA 01960, USA Section 7: Is this application for software defined radio authorization? YES NO Section 8: Is there a KDB inquiry associated with this application? YES NO If so, enter the inquiry tracking number: Section 9: Modular Approval Request: Is this application for modular approval? YES NO (if YES complete below) Modular Type: Single Modular Approval Split Modular Approval Limited Single Modular Approval Limited Split Modular Approval If yes, please include a cover letter addressing the modular approval requirements of KDB 996369 Section 10: Description of Product as it is marketed: (NOTE: This text will appear below the equipment classes on the grant) Underwater communication radio Section 11: Application Purpose Type of Application Requested: (check one box only) Original Equipment Change in identification of presently authorized equipment: Original FCC ID: Grant Date: MM/DD/YYYY Class II permissive change or modification of presently authorized equipment Class III permissive change to software defined radio NOTE: This may only be filed for applications pertaining to Software Defined Radio. Section 12: Is the equipment in this application: (a) a composite device subject to more than one type of equipment authorization? YES NO (b) part of a system that operates with, or is marketed with, another device that requires an equipment authorization? YES NO If (b) above is checked YES, answer (c) below, otherwise proceed to Section 13. (c) The related application: has been granted under the FCC ID listed i. FCC ID: is in the process of being filed under the FCC ID listed ii. FCC ID: is pending with the FCC under the FCC ID listed iii. FCC ID: has a mix of pending and granted statuses under the FCC ID(s) listed below iv. FCC ID: TCB_F_10.01, Rev. 3, Effective 2018-09-24 Page 3 of 5 TÜV SÜD America, Inc. 10 Centennial Drive, Peabody, MA 01960, USA Section 13: Equipment Specifications: where applicable Radio Type [e.g. LTE, WiFi, BTLE] Frequency Range [MHz] Rated RF Output Power in Watts [W] Frequency Tolerance [%, Hz, ppm] (please list units used) Emission Designator (see 47 CFR 2.201 & 2.202) FCC Rule Part [e.g. 15C] Equipment Class (3 characters max) [e.g. DTS] Low Frequency High Frequency VHF 175.5 215.0 0.0191 2006 Hz 200KG1D 15C DWM BT 2402 2479 0.0104 1M23G1D 15C DSS Section 14: Equipment Authorization Waiver: Is there an equipment authorization waiver associated with this application? YES NO If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? YES NO TCB_F_10.01, Rev. 3, Effective 2018-09-24 Page 4 of 5 TÜV SÜD America, Inc. 10 Centennial Drive, Peabody, MA 01960, USA Section 15: Read each certification carefully before answering and signing this application WILLFUL FALSE STATEMENTS MADE ON THIS FORM ARE PUNISHABLE BY FINE AND.OR IMPRISONMENT (U.S. CODE, TITLE 18, SECTION 1001) AND/OR REVOCATION OF ANY STATION LICENSE OR CONTRUCTION PERMIT (U.S. CODE, TITLE 47, SECTION 312(a)(1)), AND/OR FORFEITURE (U.S. TITLE 47, SECTION 503). 1. SECTION 5301 (ANTI-DRUG ABUSE) CERTIFICATION: The applicant must certify that neither the applicant nor any party to the application is subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002 (b) for the definition of a “party” for these purposes. Does the applicant or authorized agent so certify? YES NO 2. APPLICANT /AGENT CERTIFICATION: I certify that I am authorized to sign this application. All of the statements herein and the exhibits attached hereto, are true and correct to the best of my knowledge and belief. In accepting a Grant of Equipment Authorization issued by the TCB as a result of the representations made in this application, the applicant is responsible for …

Text truncated - open the document above for the full version.

Cover Letter(s)

Authorization April 15, 2020 TUV SUD America Inc. 10 Centennial Drive Peabody, MA 01960, USA FCC ID: 2APZQ- ZYGO IC ID: 23961- ZYGO Dear Sir or Madam, We, Swimmersive Co., hereby authorize Eric Lifsey of Professional Testing (EMI) Inc. to act as our agent in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. Yours sincerely, Name: H. Stephen Berger Title: Authorized Agent

Cover Letter(s)

May 29, 2018 Swimmersive Co. 16854 Mooncrest Dr. Encino, CA 91436 To Whom It May Concern: Please be advised that Swimmersive Co. authorizes TEM Consulting and its president, H. Stephen Berger, to act on our behalf in regulatory matters, until otherwise notified. Thank you for your attention to this matter. Sincerely, Sheera Goren CEO Swimmersive Co. Sheera Goren CEO

Cover Letter(s)

Request for Confidentiality Date: __05/14/20___ Subject: Confidentiality Request for: ____FCC ID: 2APZQ- ZYGO and IC ID: 23961- ZYGO ______ Pursuant to FCC 47 CRF 0.457(d) and 0.459 and IC RSP-100, Section 9.4, the applicant requests that a part of the subject FCC application be held confidential. T ype of Confidentiality RequestedExhibit Short Term PermanentBlock Diagrams Short Term External Photos Short Term Permanent* 1 Internal Photos Short Term PermanentOperation Description/Theory of Operation Short Term PermanentParts List & Placement/BOM Short Term PermanentTune-Up Procedure Short Term PermanentSchematics Short Term Test Setup Photos Short Term Permanent* 1 User’s Manual Swimmersive Co. has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify our TCB in the event information regarding the product or the product is made available to the public. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Our TCB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. 1 - The asterisked items (*) require further information to be provided to our TCB before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 and the specific Document link for D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. NOTE for Industry Canada Applications: IC currently only distinguishes Permanent Confidentiality exhibits as shown above. Short Term confidentiality is not considered applicable to IC applications. Sincerely, By: __________________________ __H. Stephen Berger_______ (Signature/Title) (Print name)

External Photos

21303 External Photos Page 1 of 3 Side 1 of 6 Side 2 Side 3 Side 4 Side 5 Side 6 of 6 ***

ID Label/Location Info

Label & Label Location FCC ID: 2APZQ- ZYGO Description: Zygo Underwater Communication Radio Model Name: Zygo Model Number: ZY100 Swimmersive Co. 16854 Mooncrest DR Encino, CA 91436 By TEM Consulting, LP 140 River Rd. Georgetown, TX 78628 February 2020 Figure 1 – Zygo Coach’s Unit showing label and label location

Internal Photos

21303 Internal Photos Page 1 of 2 Side 1 of 2 (Shield removed. VHF antenna connected.) Side 2 of 2 ***

RF Exposure Info

RF Exposure Analysis Revision 1 FCC ID 2APZQ- ZYGO Description: Zygo Underwater Communication Radio Model Name: Zygo Model Number: ZY100 Swimmersive Co. 16854 Mooncrest DR Encino, CA 91436 By TEM Consulting, LP 140 River Rd. Georgetown, TX 78628 April 2020 TYPE CERTIFICATION Table of Contents Introduction ................................................................................................................................... 2 Product Description ...................................................................................................................... 2 Zygo Radios .................................................................................................................................. 2 FCC Requirements ........................................................................................................................ 2 ISED Canada Requirements ......................................................................................................... 3 Product Analysis ........................................................................................................................... 4 Bluetooth Radio ........................................................................................................................ 4 Low Frequency Radio ............................................................................................................... 4 Simultaneous Transmission ...................................................................................................... 4 Conclusion .................................................................................................................................... 4 Introduction This memo evaluates the Zygo system coach’s unit for RF exposure testing exclusion to the FCC USA and ISED Canada Requirements. Product Description The Swimmersive Zygo is a communication system for swimmers and swimming coaches. The Zygo system has 2 components. A transmitter to stream music to swimmers or for a coach to talk to his swimmers, called the Zygo Coach’s Unit. A headset, that only receives, worn by the swimmers, called the Zygo Headset. It’s primary use is to stream music to swimmers as they work out. It also allows a coach to give instructions to swimmers as they work out. When coach’s use the unit to give instructions the unit operates push-to-talk (PTT) and the Bluetooth link is not active. In this mode the unit is handheld. The Zygo transmitter operates in the 174-216 MHz and 2.4 GHz ISM bands. The unit is battery powered. Zygo Radios The Zygo system coach’s unit has two radios, a Bluetooth radio, operating in the 2.4 GHz ISM band, and the low frequency transmitter to the headset, that operates in the 174-216 MHz band. The Bluetooth channel with the highest measured power is the low channel at 2402 MHz with a measured power of 11.0 mW (10.4 dBm). The low frequency radio channel with the highest measured power is its low channel at 176 MHz with a measured power of 67.3 mW (18.3 dBm). When used by a swimming coach the low frequency radio is a push-to-talk device. The low frequency radio has a duty cycle of transmission for 3.4 mS followed by a 1.0 mS off time. This calculates to a duty cycle of 5.3 dB. FCC Requirements FCC KDB 447498 D01 V06 section 4.3 gives SAR test exclusion guidance: 4.3. General SAR test exclusion guidance 4.3.1. Standalone SAR test exclusion considerations .... a) For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] ꞏ [√f (GHz)] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR,30 where  f(GHz) is the RF channel transmit frequency in GHz  Power and distance are rounded to the nearest mW and mm before calculation31  The result is rounded to one decimal place for comparison  The values 3.0 and 7.5 are referred to as numeric thresholds in step b) below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm, and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 4.1 f) is applied to determine SAR test exclusion. b) For 100 MHz to 6 GHz and test separation distances > 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following (also illustrated in Appendix B): 1) {[Power allowed at numeric threshold for 50 mm in step a)] + [(test separation distance – 50 mm)ꞏ(f(MHz)/150)]} mW, for 100 MHz to 1500 MHz 2) {[Power allowed at numeric threshold for 50 mm in step a)] + [(test separation distance – 50 mm)ꞏ10]} mW, for > 1500 MHz and ≤ 6 GHz The formula can be used to calculate the maximum allowable power. The power of interest is the source-based time-averaged maximum conducted output power of the RF channel. The formula for the maximum allowable power, based on the guidance of section 4.3 in the KDB, is: 푃ൌ푇∙퐷/√푓  P is the source based time-averaged maximum conducted output power in mW  T is the numeric thresholds of 3.0 and 7.5  D is the minimum separation distance in m  f is the RF channel transmit frequency in GHz For the highest frequency used, 2.48 GHz:  for a numeric threshold of 3.0 the maximum power is 9.6 mW  for a numeric threshold of 7.5 the maximum power is 23.8 mW ISED Canada Requirements Canadian regulation for RF exposure are contained in Spectrum Management and Telecommunications Radio Standards Specification RSS-102 Issue 5, March 2015, Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands). Section 2.5.1, Exemption Limits for Routine Evaluation – SAR Evaluation, provides the following exclusion limits: The values listed are for a 1 gram tissue value. If a device is worn on a limb and subject to the 10 gram value the values in the table are multiplied by 2.5: For limb-worn devices where th…

Text truncated - open the document above for the full version.

Test Report

Project 21303-15 Swimmersive Co. dba Zygo Zygo ZY100 Wireless Certification Report Bluetooth Section Prepared for: Swimmersive 16854 Mooncrest Dr Encino, CA 91436 By Professional Testing (EMI), Inc. 1601 North A.W. Grimes Blvd., Suite B Round Rock, Texas 78665 29 Apr 2020 Reviewed by Written by Shakil Murad Lead EMC Engineer Eric Lifsey EMC Engineer Swimmersive – Zygo ZY100 – Bluetooth Section 21303 Professional Testing (EMI) Inc. Page 2 of 41 Revision History Revision Number Description Date Draft 01 Draft for review. 17 Mar 2020 Draft 02 Added antenna gain supplied by client. Corrected duplicate plots. 29 Apr 2020 Draft 03 Corrected mislabeled plots. Added receiver radiated spurious 29 Apr 2020 Final 01 29 Apr 2020 Final 02 12 May 2020 Final 03 Correct top frequency in power table. 22 May 2020 Final 04 Added band edge measurements in hopping mode. 3 Jun 2020 Errata: Any reference to Coach applies to the model ZY100. Swimmersive – Zygo ZY100 – Bluetooth Section 21303 Professional Testing (EMI) Inc. Page 3 of 41 Table of Contents Revision History ............................................................................................................................................................. 2 Compliance Certificate .................................................................................................................................................. 5 1.0 Introduction .......................................................................................................................................................... 6 1.1 Scope ............................................................................................................................................................... 6 1.2 EUT Description ............................................................................................................................................. 6 1.3 EUT Operation ................................................................................................................................................ 6 1.4 Modifications to Equipment ............................................................................................................................ 6 1.5 Test Site .......................................................................................................................................................... 6 1.6 Radiated Measurements .................................................................................................................................. 7 1.7 Applicable Documents and Clauses ................................................................................................................ 7 2.0 Fundamental Power ............................................................................................................................................. 8 2.1 Test Procedure ................................................................................................................................................ 8 2.2 Test Criteria .................................................................................................................................................... 8 2.3 Test Results, Peak Power ................................................................................................................................ 8 2.3.1 Unmodulated ......................................................................................................................................... 8 2.3.2 Modulations: .......................................................................................................................................... 9 2.4 Test Results, Duty Cycle ............................................................................................................................... 10 3.0 Hopping ............................................................................................................................................................. 12 3.1 Test Procedure .............................................................................................................................................. 12 3.2 Test Criteria .................................................................................................................................................. 12 3.3 Test Results ................................................................................................................................................... 12 3.1 Test Results, Timing ..................................................................................................................................... 13 3.2 Test Results, Channel Separation .................................................................................................................. 14 4.0 Occupied Bandwidth .......................................................................................................................................... 15 4.1 Test Procedure .............................................................................................................................................. 15 4.2 Test Criteria .................................................................................................................................................. 15 4.3 Test Results ................................................................................................................................................... 15 4.3.1 Bandwidth Plots, Modulation 1 ........................................................................................................... 16 4.3.2 Bandwidth Plots, Modulation 2 ........................................................................................................... 17 4.3.3 Bandwidth Plots, Modulation 3 ........................................................................................................... 18 5.0 Band Edge .......................................…

Text truncated - open the document above for the full version.

Test Setup Photos

21303 External Photos Page 1 of 4 Emissions Front < 1 GHz Emissions Back < 1 GHz Emissions Front > 1 GHz Emissions Front > 1 GHz Emissions 18-25 GHz Conducted Antenna Port Measurements Timing Measurements Stability ***

Contact Information

Applicant

Sheera Goren(CEO)
[email protected]8184452293Fax: 8189056678

Test Firm

Professional Testing (EMI), Inc.Larry Finn
[email protected]512-244-3371Fax: 512-244-1846

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz10.40 mW
Confidentiality
Long Term
Grant Notes
Power listed is Conducted.

Other Applications from Swimmersive Co.

Underwater Communication Radio Headset - FCC ID 2APZQ-ZYGO2H - Swimmersive Co.
2APZQ-ZYGO2H

Underwater Communication Radio Headset

Sep 10, 2024

Equipment Class

DWM - Part 15 Wireless Microphone
Underwater Communication Radio - FCC ID 2APZQ-ZYGO2T - Swimmersive Co.
2APZQ-ZYGO2T

Underwater Communication Radio

Sep 10, 2024

Equipment Class

DTS - Digital Transmission System
Headset system for coaching swimmers - FCC ID 2APZQ-ZYGOV2 - Swimmersive Co.
2APZQ-ZYGOV2

Headset system for coaching swimmers

Oct 02, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter