  2. Shenzhen Interthings Technology Co., Ltd./
  3. 2AQ7B-IPC236

2AQ7B-IPC236Smart Two Way Security Camera

Shenzhen Interthings Technology Co., Ltd.
Smart Two Way Security Camera - FCC ID 2AQ7B-IPC236 - Shenzhen Interthings Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Aug 13, 2026
Application Purpose
Original Equipment
Equipment Note
Smart Two Way Security Camera
Frequency Range
5180.00000000 - 5240.00000000
Company
Shenzhen Interthings Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

QUICK START GUIDE HUVIPC223 Read me before use! Keep manual and all relevant information for future reference. Description of the camera 1. LCD display 2. Camera lens 3. Call out button (video call to app holder) 4. Hang up the video call 5. Microphone 6. Manually adjustable bracket 7. Reset button 8. Micro SD card slot 9. USB-C power supply interface About the camera 1. Power on the camera To power on the camera, use a 5V (1A~2A) adapter (not included) to connect camera with supplied power cable. The LCD will turn on and camera with a voice prompt, which means camera is ready for connection. 2. Micro SD card To save the events into local storage, the camera needs a 8GB~256GB (Class 10 or higher) micro SD card. Please format the card before using. 3. Reset If the device is not able to be connected to the app, you may need to reset the camera. Hold and press the reset button for 5 seconds, the camera will be restarted and you will hear the “welcome” voice announcement, which means the reset is succeed and the camera is ready to connect. 4. Installation the camera Connect the camera with App to check the signal before mounting the camera. Installation the camera: Setup with the App 1. Download and Install the app: Download and install the HALOWatch app by scanning the QR code for the Apple Store or Google Play Store. HALOWATCH Check that you have a strong Wi-Fi signal (at least two bars) where the smart camera is to be installed. 2. Account Registration: Open the app and register a new account or log in to an existing account. 3. Add Camera: Navigate to the Home Page within the app. Locate and select "Add Camera" then go through preparation instructions to power on your camera properly. 4. Bluetooth Access: Follow the on-screen instructions to enable Bluetooth access, which is required for device discovery. Do not skip this step. Ensure Bluetooth access is enabled as instructed, allowing the app to discover the device via BLE. 5. Connect to Wi-Fi: The app will automatically scan for nearby 2.4 GHz &5 GHz Wi-Fi routers. Note: This camera supports both 2.4GHz and 5GHz Wi-Fi. 6. Input Wi-Fi Credentials: Enter the password for your selected Wi-Fi network. Click "Next" to initiate connection. Wait a few seconds for the device to connect to the internet. You'll hear a notification sound from the device indicating successful progress. 7. Live view and app support Hear and talk to the camera with the app. If you have any questions or suggestions, find the support icon as following to chat or e-mail with us. FCC Statement Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Attestation Statements

ShenzhenInterthingsTechnologyCo.,Ltd. 701,Building1,LechuanghuiBuilding,No.1211GuanguangRoad,Longhua District,Shenzhen,China FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 Date:August5,2026 U.S.AgentDesignation {ShenzhenInterthingsTechnologyCo.,Ltd.}acknowledgestheirconsentforthefollowingcontactlocatedin theUnitedStatestoactastheiragentforserviceofprocessfortheequipmentforwhichauthorizationissought (FCCID:2AQ7B-IPC236): NameandcompanyofU.S.agent:BridgeportAdvisoryLLC PhysicalU.S.addressofagent:3330W38THPL,CHICAGO,IL60632,UnitedStates FRNofU.S.agent:0037566148 EmailaddressofU.S.agent:[email protected] ContactNO.:(708)680-6688 BridgeportAdvisoryLLCacknowledgestheirobligationtoacceptserviceofprocessonbehalfof{Shenzhen InterthingsTechnologyCo.,Ltd.}. {ShenzhenInterthingsTechnologyCo.,Ltd.}withtheFRN[0037109725]acceptsitsobligationtomaintainan agentforserviceofprocessintheUnitedStatesfornolessthanoneyearaftereitherthegranteehas permanentlyterminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S.,orthe conclusionofanyCommission-relatedadministrativeorjudicialproceedinginvolvingtheequipment,whicheveris later. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirementslistedunder§ 2.911(d)(7). TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB 986446D01. Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,thegranteeisobligatedtonotify theFCCwithin30daysviathegrantingTCB. Sincerely, Signature LucyFang Manager ShenzhenInterthingsTechnologyCo.,Ltd. Signature MrYongLiu ManagingMember BridgeportAdvisoryLLC 4 8 _ [ m o d e l ] U S _ A g e n t _ 2 . 9 1 1 ( d ) ( 7 ) - U , V 0 5

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2AQ7B-IPC236 IPC236, HUVIPC223E We, Applicant Company Name: Shenzhen Interthings Technology Co., Ltd. Address: 701, Building 1, Lechuanghui Building, No. 1211 Guanguang Road, Longhua District, Shenzhen, China Phone: +86-18820953014 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. This includes the cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc. or any of ist successors and assignees. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2026-08-05 Signature Date Name / Title: Lucy Fang / Manager Company: Shenzhen Interthings Technology Co., Ltd. Address: 701, Building 1, Lechuanghui Building, No. 1211 Guanguang Road, Longhua District, Shenzhen, China Phone: +86-18820953014 Fax: N/A E-Mail: [email protected]

Attestation Statements

Due Diligence Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern FCC ID Model name 2AQ7B-IPC236 IPC236, HUVIPC223E Pursuant to KDB 986446 D01 Covered Equipment Guidance the evaluation of the product above shows compliance for the following reasons: Compliance Evaluation process Results Inherent compliance The chipset(s) used is not capable of running the cybersecurity and/or anti-virus software Compliance The memory used does not allow the running the cybersecurity and/or anti-virus software Compliance The storage capacity does not allow the running the cybersecurity and/or anti-virus software Compliance The operating system used is not capable of running the cybersecurity and/or anti-virus software Compliance No inherent compliance Based on software bill of material Based on scan for running software on the device Based on filesystem scan for cybersecurity and/or anti-virus software The equipment for which authorization is sought complies with the rules and fulfils the requirements as detailed in the above mentioned KDB. Evaluation performed by Company Name: Shenzhen Huaxia Testing Technology Co., Ltd Contact Name: Yoyo Zhou Address: 1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District, Shenzhen, China Phone: +86-755-26648642 Email: [email protected] Signature: Date: 2026-08-11

Cover Letter(s)

Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2AQ7B-IPC236 IPC236, HUVIPC223E For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Part List • the Tune up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2026-08-05 Signature Date Name / Title: Lucy Fang / Manager Company: Shenzhen Interthings Technology Co., Ltd. Address: 701, Building 1, Lechuanghui Building, No. 1211 Guanguang Road, Longhua District, Shenzhen, China Phone: +86-18820953014 Fax: N/A E-Mail: [email protected]

Cover Letter(s)

ShenzhenInterthingsTechnologyCo.,Ltd. ModelConfirmationLetter Theirelectricalcircuitdesign,layout,componentsusedandinternalwiringareidentical, Onlythemadelnameweredifferent We, Shenzhen Interthings Technology Co.,Ltd. certify the product: Smart Two Way Security Camera Model No.: IPC236, HUVIPC223E FCC ID:2AQ7B-IPC236 . Signiture: GranteeContact:LucyFang CompanyName:ShenzhenInterthingsTechnologyCo.,Ltd. Date:August5,2026

External Photos

ReportNo.:CQASZ20260300611E Photographs-EUTConstructionalDetails ReportNo.:CQASZ20260300611E ReportNo.:CQASZ20260300611E ReportNo.:CQASZ20260300611E

Internal Photos

ReportNo.:CQASZ20260300611E Photographs-EUTConstructionalDetails ReportNo.:CQASZ20260300611E ReportNo.:CQASZ20260300611E ReportNo.:CQASZ20260300611E

RF Exposure Info

SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD 102A,102B,Building2,ShanghenglangNewIndustrialZone,ShanghenglangCommunity, DalangStreet,LonghuaDistrict,Shenzhen,Guangdong,People’sRepublicofChina,518000 Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V06 ReportTemplateRevisionDate:2026-01-30 RFExposureEvaluationReport Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonlyto thesample(s)tested.WithoutwrittenapprovalofCQA,thisreportcan’tbereproducedexceptinfull. ReportNo.:CQASZ20260300611E-04 Applicant:ShenzhenInterthingsTechnologyCo.,Ltd. AddressofApplicant:701,Building1,LechuanghuiBuilding,No.1211GuanguangRoad,Longhua District,Shenzhen,China EquipmentUnderTest(EUT): EUTName:SmartTwoWaySecurityCamera ModelNo.:IPC236,HUVIPC223E TestModelNo.:IPC236 BrandName:N/A FCCID:2AQ7B-IPC236 Standards: 47CFRPart1.1307 47CFRPart1.1310 KDB447498D01GeneralRFExposureGuidancev06 DateofReceipt:2026-06-16 DateofTest:2026-06-16to2026-06-30 DateofIssue:2026-8-11 TestResult:PASS* *Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove TestedBy: (LewisZhou) ReviewedBy: (TimoLei) ApprovedBy: (JackAi) SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260300611E-04 Page:2of10 1Version RevisionHistoryOfReport ReportNo.Version Description IssueDate CQASZ20260300611E-04Rev.01 Initialreport 2026-8-11 SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260300611E-04 Page:3of10 2Contents Page 1VERSION............................................................................................................................................................................2 2CONTENTS........................................................................................................................................................................3 ..................................................................................................................................................................................................3 3GENERALINFORMATION..............................................................................................................................................4 3.1CLIENTINFORMATION...................................................................................................................................................4 3.2GENERALDESCRIPTIONOFEUT...................................................................................................................................4 3.3GENERALDESCRIPTIONOFBLE...................................................................................................................................5 3.4GENERALDESCRIPTIONOF2.4GWIFICLASSIC...........................................................................................................5 3.5GENERALDESCRIPTIONOF5GWIFICLASSIC..............................................................................................................5 4MPEEVALUATION...........................................................................................................................................................7 4.1RFEXPOSURECOMPLIANCEREQUIREMENT.................................................................................................................7 4.1.1Limits....................................................................................................................................................................7 4.1.2TestProcedure...................................................................................................................................................7 4.1.3EUTRFExposure..............................................................................................................................................8 SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260300611E-04 Page:4of10 3GeneralInformation 3.1ClientInformation Applicant:ShenzhenInterthingsTechnologyCo.,Ltd. AddressofApplicant: 701,Building1,LechuanghuiBuilding,No.1211GuanguangRoad, LonghuaDistrict,Shenzhen,China Manufacturer: ShenzhenInterthingsTechnologyCo.,Ltd. AddressofManufacturer: 701,Building1,LechuanghuiBuilding,No.1211GuanguangRoad, LonghuaDistrict,Shenzhen,China Factory:ShenzhenInterthingsTechnologyCo.,Ltd. AddressofFactory:701,Building1,LechuanghuiBuilding,No.1211GuanguangRoad, LonghuaDistrict,Shenzhen,China 3.2GeneralDescriptionofEUT ProductName: SmartTwoWaySecurityCamera ModelNo.: IPC236,HUVIPC223E TestModelNo.: IPC236 TradeMark: N/A SoftwareVersion: V1.0 HardwareVersion: V1.0 EUTPowerSupply: PowerbyadapterDC5V SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260300611E-04 Page:5of10 3.3GeneralDescriptionofBLE OperationFrequency: 2402MHz~2480MHz BluetoothVersion: BluetoothSpec5.0 ModulationTechnique: FrequencyHoppingSpreadSpectrum(FHSS) ModulationType: GFSK NumberofChannel: 40 TransferRate:1Mbps/2Mbps SampleType: MobilePortableFixLocation AntennaType: FPCantenna AntennaGain: 1.96dBi 3.4GeneralDescriptionof2.4GWIFIClassic OperationFrequency:IEEE802.11b/g/n(HT20):2412MHzto2462MHz IEEE802.11n(HT40):2422MHzto2452MHz TypeofModulation: 802.11b:DSSS(CCK/QPSK/BPSK) 802.11g:OFDM(BPSK/QPSK/16QAM/64QAM) 802.11n:OFDM(64QAM,16QAM,QPSK,BPSK) NumberofChannel: IEEE802.11b/g,IEEE802.11nHT20:11Channels IEEE802.11nHT40:7Channels ChannelSeparation: 5MHz TransferRate: 802.11b:1M/2M/5.5M/11Mbps 802.11g:6M/9M/12M/18M/24M/36M/48M/54Mbps 802.11n:7.2M/14.4M/21.7M/28.9M/43.3M/57.8M/65M/72.2Mbps SampleType: MobilePortable AntennaType: FPCantenna AntennaGain: 1.96dBi 3.5GeneralDescriptionof5GWIFIClassic OperationFrequency: IEEE802.11a/n/ac(20M):5150MHz~5250MHz IEEE802.11n/ac(40M):5150MHz~5250MHz IEEE802.11n/ac(80M):5150MHz~5250MHz IEEE802.11a/n/ac(20M):5250MHz~5350MHz IEEE802.11n/ac(40M):5250MHz~5350MHz IEEE802.11n/ac(80M):5250MHz~5350MHz IEEE802.11a/n/ac(20M):5470MHz~5725MHz IEEE802.11n/ac(40M):5470MHz~5725MHz IEEE802.11n/ac(80M):5470MHz~5725MHz IEEE802.11a/n/ac(20M):5725MHz~5850MHz IEE…

Text truncated - open the document above for the full version.

Test Report

深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址: 深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 承认书 SPECIFICATIONFORAPPROVAL 审批/Approval客户批准/CustomerApproval 制作 PreparedBy 审核 CheckedBy 批准 ApprovalBy 审核 CheckedBy 批准 ApprovalBy 签章 Signature 黄宗宝夏承磊陈华明 日期 Date 2026.03.032026.03.032026.03.03 修订履历/ChangeLog 版本 Version 修订内容 ChangeDescription 责任人 PersoninCharge 核准 ApprovalBy 日期 Date 客户名称 CustomerName 盈通 客户项目名Customer ProjectName IPC236 顺达成项目名 SDCProjectName IPC236 客户编码 CustomerP/N 顺达成料号 SDCP/N WF714B-0812L-110 频段 Band WIFI 版本号 Version A0 设计人信息/DesignerInformation 射频工程师 RFEngineer 伍文载 研发主管 R&DDiretor 夏承磊 结构工程师 MEEngineer 黄宗宝 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址: 深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 目录/Catalogue 序号 No. 项目 Item 页码 PageNo. 1 图纸或实物图片 DrawingorProductImage 3 2 尺寸测量报告 DimensionsTestReport 4 3 射频性能测试报告 RFPerformanceTestReport 5-8 4 可靠性测试报告 ReliabilityTestReport1 9 5 包装文件 PackageDocument 10 6 环境有害物质管控一览表 RoHSControllistforSample 11 7 安装事宜或其它 InstallWizard orOther 11 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址: 深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 产品图纸或实物图片 DrawingorProductImage D E S C R I P T I O N N O Q ' T Y 2 1 3 1 R E M A R K 1 1 0 C a b l e ? 0 . 8 1 C a b l e B l a c k , 5 0 Ω F P C - 黑 油 黑 字 半 对 半 基 材 , 做 抗 氧 化 处 理 3 M 9 4 7 1 背 胶 F P C 6 5 4 3 2 1 A B X X . X . . X X . X X X . X C H E C K E D ± 1 . 0 D R A W I N G ± 0 . 1 ± 0 . 5 A P P R O V E D ± 3 . 0 ± 5 F I L E : S H E E T : P A R T N A M E : R E V A 0 U N I T m / m C U S T O M E R : 1 / 1 6 5 4 C D E 3 2 2 0 2 6 . 0 3 . 0 3 A 0 F R E V D A T E N e w I s s u e G D E S C R I P T I O N 1 深 圳 市 顺 达 成 科 技 有 限 公 司 W F 7 1 4 B - 0 8 1 2 L - 1 1 0 S D C P / N O : W I F I 天 线 ( I P C 2 3 6 ) F P C 丝 印 ( S D C F 5 4 3 A W F ) + 0 . 8 1 黑 色 线 + I P E X 2 左 L = 1 1 0 m m - - 4 8 . 6 8 * 7 . 9 盈 通 端 子 I P E X 2 1 符 学 荣 李 瑶 娜 李 瑶 娜 注 : 6 0 m m 以 内 的 线 材 , 若 无 客 户 要 求 则 默 认 端 子 头 朝 下  S D C F 5 4 3 A W F   深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址: 深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 样品尺寸测量报告 SampleDimensionsTestReport 测试日期 TestDate 2026.03.03 样品数量 SampleQty. 3 测试人 Inspector 许燕芳 尺寸编号 DimensionNo. 标准 Standard 样品1 Sample1 样品2 Sample2 样品3 Sample3 Pass/NG ①长度48.68±0.2mm48.6848.748.75 Pass ②宽度7.9±0.2mm7.98.07.9 Pass ③厚度0.1±0.03mm0.10.101 Pass ④线长110±2mm110111110 Pass 最终结论 Conclusion PASS 测试人&日期 Inspector&Date 许燕芳2026.03.03 批准&日期 Approval&Date 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址: 深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 射频性能测量报告 RFPerformanceTestReport 天线测试设备简介 AntennaTestEquipmentIntroduction 测试天线输入特性使用AgilentE5071CandAgilent5062A矢量网络分析仪;辐射特性利用 广屏三维近场暗室进行测试,并分别使用8960E5515和AgilentE4438C进行了分析。暗房的测试坐 标如下: TestofantennainputcharacteristicsusingAgilentE5071CandAgilent5062Avectornetwork analyzer;Theradiationpatternoftheantennaaretestedusingtheguangping3DnearfieldAnechoicChamber, andtheinstrumentisusedtoagilent8960E5515andAgilentE4438C.Thetestcoordinatesofthedarkroomare asfollows: 1.S11参数测量/S11Parameter-VSWR 使用一根50Ω同轴电缆连接到天线,然后该电缆连接到网络分析仪测量S11参数,被测量产品远离金属至少 20厘米。 MeasuringMethodisa50 Ω coaxialcableisconnectedtotheantenna.Thenthiscableisconnectedtoanetworkanalyzerto measuretheS11parameter,Keepingthisfixtureawayfrommetalatleast20cm. 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址: 深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 S11Parameter-VSWR 2.天线匹配网络/ AntennaMatchingNetwork 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址: 深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 3.Gain&Efficiency 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址: 深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址: 深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 4.WIFIOTA 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址: 深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 可靠性测试报告 ReliabilityTestReport 测试日期 TestDate 2026.03.03 样品数量 SampleQty. 3 测试人 Inspector 许燕芳 测试项目 TestItem 要求 Requirement 试验设备 testing equipment 样品1 Sample1 样品2 Sample2 样品3 Sample3 判定 PASS/NG 高温存储 在+85°C条件下暴露 24H,恢复2H后进行测 试 恒温恒湿箱OKOKOKPass 低温存储 在-40°C条件下暴露 24H,恢复2H后进行测 试 恒温恒湿箱OKOKOKPass 高温工作 在+60°C条件下通电工 作24H 恒温恒湿箱OKOKOKPass 低温工作 在-20°C条件下通电工 作24H 恒温恒湿箱OKOKOKPass 盐雾试验 (5士0.5)%氯化钠、 pH值为6.5~7.2,实验 箱温度(35±2)°C □24H☑48H 盐雾试验机OKOKOKPass 连接器铆压拉 拔力 1.13线径≥10N 0.81线径≥8N RG174≥60N RG178≥50N 推拉力计≥10N≥10N≥10NPass 最终结论 Conclusion Pass 测试人&日 期 Inspector& Date 许燕芳2026.03.03 批准&日期 Approval&D ate 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址: 深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址: 深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 安装事宜或其它 InstallWizardorOther 安装过程: 取1PCS产品,用手撕下FPC背面的离型纸,然后将FPC定位孔位置与外壳定位孔位置(定位筋 位或定位线)对齐,平整的贴附与外壳上,具体位置如下图所示: 安装过程注意事项: □粘贴天线后保证FPC完整贴附于外壳; □定位孔与外壳定位柱位置对齐; □FPC边缘与外壳边缘对齐; □带端子天线在将端子扣合到主板PCBA端时请首先对齐端子,然后垂直扣合; □拆卸天线端子时需使用工具(如专用撬棍)垂直翘起端子,不可直接拽线拆卸 深圳市顺达成科技有限公司 SHUNDACHENGTECHNOLOGYCO.,LTD 公司地址: 深圳市宝安区福永镇重庆路新福工业园B5栋4楼电话:0755-27211658传真:0755-29485750 产品ROHS证书

Test Report

CQASZ20260300611E-03 Appendix A1: Emission Bandwidth Test Result TestMode Freq (MHz) 26db EBW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11A 5180 20.16 5169.84 5190.00 --- --- 5200 19.56 5190.12 5209.68 --- --- 5240 19.88 5230.08 5249.96 --- --- 5745 20.20 5734.88 5755.08 --- --- 5785 19.68 5775.20 5794.88 --- --- 5825 19.80 5815.00 5834.80 --- --- 11N20SISO 5180 20.20 5169.96 5190.16 --- --- 5200 20.16 5189.76 5209.92 --- --- 5240 20.04 5229.96 5250.00 --- --- 5745 20.20 5734.88 5755.08 --- --- 5785 20.16 5774.96 5795.12 --- --- 5825 19.88 5814.96 5834.84 --- --- 11N40SISO 5190 41.20 5169.28 5210.48 --- --- 5230 40.80 5209.68 5250.48 --- --- 5755 40.16 5734.76 5774.92 --- --- 5795 40.56 5774.60 5815.16 --- --- 11AC20SISO 5180 20.28 5169.76 5190.04 --- --- 5200 20.20 5189.84 5210.04 --- --- 5240 20.20 5229.96 5250.16 --- --- 5745 20.32 5734.80 5755.12 --- --- 5785 20.12 5774.80 5794.92 --- --- 5825 20.24 5814.72 5834.96 --- --- 11AC40SISO 5190 40.56 5169.60 5210.16 --- --- 5230 40.88 5209.36 5250.24 --- --- 5755 40.24 5734.76 5775.00 --- --- 5795 40.64 5774.52 5815.16 --- --- 11AC80SISO 5210 80.80 5169.20 5250.00 --- --- 5775 80.16 5735.00 5815.16 --- --- Test Graphs 11A_Ant1_5180 11A_Ant1_5200 11A_Ant1_5240 11A_Ant1_5745 11A_Ant1_5785 11A_Ant1_5825 11N20SISO_Ant1_5180 11N20SISO_Ant1_5200 11N20SISO_Ant1_5240 11N20SISO_Ant1_5745 11N20SISO_Ant1_5785 11N20SISO_Ant1_5825 11N40SISO_Ant1_5190 11N40SISO_Ant1_5230 11N40SISO_Ant1_5755 11N40SISO_Ant1_5795 11AC20SISO_Ant1_5180 11AC20SISO_Ant1_5200 11AC20SISO_Ant1_5240 11AC20SISO_Ant1_5745 11AC20SISO_Ant1_5785 11AC20SISO_Ant1_5825 11AC40SISO_Ant1_5190 11AC40SISO_Ant1_5230 11AC40SISO_Ant1_5755 11AC40SISO_Ant1_5795 11AC80SISO_Ant1_5210 11AC80SISO_Ant1_5775 Appendix A2: Occupied channel bandwidth Test Result TestMode Freq (MHz) OCB [MHz] Limit[MHz] Verdict 11A 5180 16.983 --- --- 5200 17.223 --- --- 5240 16.903 --- --- 5745 16.823 --- --- 5785 16.903 --- --- 5825 16.983 --- --- 11N20SISO 5180 17.982 --- --- 5200 17.862 --- --- 5240 17.902 --- --- 5745 17.942 --- --- 5785 17.862 --- --- 5825 17.902 --- --- 11N40SISO 5190 35.964 --- --- 5230 36.044 --- --- 5755 36.124 --- --- 5795 35.964 --- --- 11AC20SISO 5180 18.062 --- --- 5200 17.942 --- --- 5240 17.902 --- --- 5745 18.102 --- --- 5785 17.902 --- --- 5825 17.942 --- --- 11AC40SISO 5190 35.884 --- --- 5230 36.124 --- --- 5755 36.284 --- --- 5795 36.204 --- --- 11AC80SISO 5210 75.764 --- --- 5775 75.285 --- --- Test Graphs 11A_Ant1_5180 11A_Ant1_5200 11A_Ant1_5240 11A_Ant1_5745 11A_Ant1_5785 11A_Ant1_5825 11N20SISO_Ant1_5180 11N20SISO_Ant1_5200 11N20SISO_Ant1_5240 11N20SISO_Ant1_5745 11N20SISO_Ant1_5785 11N20SISO_Ant1_5825 11N40SISO_Ant1_5190 11N40SISO_Ant1_5230 11N40SISO_Ant1_5755 11N40SISO_Ant1_5795 11AC20SISO_Ant1_5180 11AC20SISO_Ant1_5200 11AC20SISO_Ant1_5240 11AC20SISO_Ant1_5745 11AC20SISO_Ant1_5785 11AC20SISO_Ant1_5825 11AC40SISO_Ant1_5190 11AC40SISO_Ant1_5230 11AC40SISO_Ant1_5755 11AC40SISO_Ant1_5795 11AC80SISO_Ant1_5210 11AC80SISO_Ant1_5775 Appendix A3: Min emission bandwidth Test Result B4 TestMode Freq (MHz) 6db EBW [MHz] Limit[MHz] Verdict 11A 5745 15.44 0.5 PASS 5785 13.88 0.5 PASS 5825 16.36 0.5 PASS 11N20SISO 5745 15.04 0.5 PASS 5785 15.76 0.5 PASS 5825 15.12 0.5 PASS 11N40SISO 5755 35.04 0.5 PASS 5795 35.12 0.5 PASS 11AC20SISO 5745 15.12 0.5 PASS 5785 15.12 0.5 PASS 5825 15.00 0.5 PASS 11AC40SISO 5755 35.12 0.5 PASS 5795 35.12 0.5 PASS 11AC80SISO 5775 75.20 0.5 PASS Test Graphs B4 11A_Ant1_5745 11A_Ant1_5785 11A_Ant1_5825 11N20SISO_Ant1_5745 11N20SISO_Ant1_5785 11N20SISO_Ant1_5825 11N40SISO_Ant1_5755 11N40SISO_Ant1_5795 11AC20SISO_Ant1_5745 11AC20SISO_Ant1_5785 11AC20SISO_Ant1_5825 11AC40SISO_Ant1_5755 11AC40SISO_Ant1_5795 11AC80SISO_Ant1_5775 Appendix B: Duty Cycle Test Result TestMode Freq (MHz) Transmission Duration [ms] Transmission Period [ms] Duty Cycle [%] Limit Verdict 11A 5180 1.38 1.42 97.18 --- --- 5200 1.39 1.43 97.20 --- --- 5240 1.38 1.42 97.18 --- --- 5745 1.38 1.42 97.18 --- --- 5785 1.38 1.43 96.50 --- --- 5825 1.38 1.43 96.50 --- --- 11N20SISO 5180 1.29 1.34 96.27 --- --- 5200 1.29 1.33 96.99 --- --- 5240 1.29 1.33 96.99 --- --- 5745 1.29 1.34 96.27 --- --- 5785 1.29 1.34 96.27 --- --- 5825 1.29 1.34 96.27 --- --- 11N40SISO 5190 0.64 0.68 94.12 --- --- 5230 0.64 0.69 92.75 --- --- 5755 0.64 0.69 92.75 --- --- 5795 0.64 0.69 92.75 --- --- 11AC20SISO 5180 1.30 1.35 96.30 --- --- 5200 1.30 1.35 96.30 --- --- 5240 1.30 1.35 96.30 --- --- 5745 1.31 1.35 97.04 --- --- 5785 1.31 1.35 97.04 --- --- 5825 1.31 1.35 97.04 --- --- 11AC40SISO 5190 0.65 0.69 94.20 --- --- 5230 0.64 0.69 92.75 --- --- 5755 0.65 0.69 94.20 --- --- 5795 0.64 0.69 92.75 --- --- 11AC80SISO 5210 0.33 0.37 89.19 --- --- 5775 0.32 0.37 86.49 --- --- Test Graphs 11A_Ant1_5180 11A_Ant1_5200 11A_Ant1_5240 11A_Ant1_5745 11A_Ant1_5785 11A_Ant1_5825 11N20SISO_Ant1_5180 11N20SISO_Ant1_5200 11N20SISO_Ant1_5240 11N20SISO_Ant1_5745 11N20SISO_Ant1_5785 11N20SISO_Ant1_5825 11N40SISO_Ant1_5190 11N40SISO_Ant1_5230 11N40SISO_Ant1_5755 11N40SISO_Ant1_5795 11AC20SISO_Ant1_5180 11AC20SISO_Ant1_5200 11AC20SISO_Ant1_5240 11AC20SISO_Ant1_5745 11AC20SISO_Ant1_5785 11AC20SISO_Ant1_5825 11AC40SISO_Ant1_5190 11AC40SISO_Ant1_5230 11AC40SISO_Ant1_5755 11AC40SISO_Ant1_5795 11AC80SISO_Ant1_5210 11AC80SISO_Ant1_5775 Appendix C: Maximum conducted output power Test Result Channel Power Test Mode Antenna Freq (MHz) Set Power Channel Powert [dBm] Duty Cycle [%] DC Factor [dBm] Result [dBm] Limit [dBm] Gain [dBi] EIRP [dBm] EIRP Limit [dBm] Verdict 11A Ant1 5180 --- 10.11 97.18 0.12 10.23 ≤23.98 2.78 13.01 --- PASS 5200 --- 9.27 97.20 0.12 9.39 ≤23.98 2.78 12.17 --- PASS 5240 --- 8.74 97.18 0.12 8.86 ≤23.98 2.78 11.64 --- PASS 5745 --- 7.89 97.18 0.12 8.01 ≤30.00 2.78 10.79 --- PASS 5785 --- 7.98 96.50 0.15 8.13 ≤30.00 2.78 10.91 --- PASS 5825 --- 7.70 96.50 0.15 7.85 ≤30.00 2.78 10.63 --- PASS 11N20SI SO Ant1 5180 --- 9.83 96.27 0.17 10.00 ≤23.98 2.78 12.78 --- PASS 5200 --- 9.08 96.99 0.13 9.21 ≤23.98 2.78 11.99 --- PASS 5240 --- 8.63 96.99 0…

Text truncated - open the document above for the full version.

Test Report

11N40SISO_Ant1_5230 11N40SISO_Ant1_5755 11N40SISO_Ant1_5795 11AC20SISO_Ant1_5180 11AC20SISO_Ant1_5200 11AC20SISO_Ant1_5240 11AC20SISO_Ant1_5745 11AC20SISO_Ant1_5785 11AC20SISO_Ant1_5825 11AC40SISO_Ant1_5190 11AC40SISO_Ant1_5230 11AC40SISO_Ant1_5755 11AC40SISO_Ant1_5795 11AC80SISO_Ant1_5210 11AC80SISO_Ant1_5775 Appendix D: Maximum power spectral density Test Result TestMode Freq (MHz) Result [dBm/MHz] Limit[dBm/MHz] Verdict 11A 5180 -0.16 ≤11.00 PASS 5200 -0.72 ≤11.00 PASS 5240 -1.05 ≤11.00 PASS 5745 -5.33 ≤30.00 PASS 5785 -4.87 ≤30.00 PASS 5825 -5.22 ≤30.00 PASS 11N20SISO 5180 -0.60 ≤11.00 PASS 5200 -1.33 ≤11.00 PASS 5240 -1.57 ≤11.00 PASS 5745 -5.75 ≤30.00 PASS 5785 -5.28 ≤30.00 PASS 5825 -5.74 ≤30.00 PASS 11N40SISO 5190 -3.38 ≤11.00 PASS 5230 -4.15 ≤11.00 PASS 5755 -7.39 ≤30.00 PASS 5795 -7.83 ≤30.00 PASS 11AC20SISO 5180 -0.80 ≤11.00 PASS 5200 -1.09 ≤11.00 PASS 5240 -2.37 ≤11.00 PASS 5745 -5.64 ≤30.00 PASS 5785 -5.19 ≤30.00 PASS 5825 -5.79 ≤30.00 PASS 11AC40SISO 5190 -3.41 ≤11.00 PASS 5230 -4.72 ≤11.00 PASS 5755 -7.34 ≤30.00 PASS 5795 -8.01 ≤30.00 PASS 11AC80SISO 5210 -6.55 ≤11.00 PASS 5775 -11.31 ≤30.00 PASS Note:1.The Result and Limit Unit is dBm/500 kHz in the band 5.725−5.85 GHz. 2.The Duty Cycle Factor and RBW Factor is compensated in the graph. Test Graphs 11A_Ant1_5180 11A_Ant1_5200 11A_Ant1_5240 11A_Ant1_5745 11A_Ant1_5785 11A_Ant1_5825 11N20SISO_Ant1_5180 11N20SISO_Ant1_5200 11N20SISO_Ant1_5240 11N20SISO_Ant1_5745 11N20SISO_Ant1_5785 11N20SISO_Ant1_5825 11N40SISO_Ant1_5190 11N40SISO_Ant1_5230 11N40SISO_Ant1_5755 11N40SISO_Ant1_5795 11AC20SISO_Ant1_5180 11AC20SISO_Ant1_5200 11AC20SISO_Ant1_5240 11AC20SISO_Ant1_5745 11AC20SISO_Ant1_5785 11AC20SISO_Ant1_5825 11AC40SISO_Ant1_5190 11AC40SISO_Ant1_5230 11AC40SISO_Ant1_5755 11AC40SISO_Ant1_5795 11AC80SISO_Ant1_5210 11AC80SISO_Ant1_5775 Appendix E: Band edge measurements Test Result B1 TestMode ChName Freq(MHz) Result[dBm] Limit[dBm] Verdict 11A Low 5180 -48.58 ≤-27 PASS High 5240 -50.4 ≤…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Lucy Fang(Manager)
[email protected]Fax: 86-755-21040734

Technical Contact

Bridgeport Advisory LLCYong Liu
[email protected]

3330 W 38TH PL, CHICAGO, · Illinois, 60632 · United States

Test Firm

Shenzhen Huaxia Testing Technology Co., LtdJack Ai
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115E5.18 GHz - 5.24 GHz10.50 mW
215E5.75 GHz - 5.83 GHz7.70 mW
Confidentiality
Long Term
Grant Notes
Power listed is maximum average conducted output power. The device supports 20 MHz, 40 MHz and 80 MHz bandwidth modes as described in this filing. The product must be installed such that its antenna(s) can provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing. Device also contains 2.4GHz WLAN and BLE transmitters.

Other Applications from Shenzhen Interthings Technology Co., Ltd.

Digital Frame - FCC ID 2AQ7B-PF326 - Shenzhen Interthings Technology Co., Ltd.
2AQ7B-PF326

Digital Frame

Aug 20, 2026

Equipment Class

DTS - Digital Transmission System
2AQ7B-IPB217

Smart Doorbell

Aug 03, 2026

Equipment Class

DTS - Digital Transmission System
Smart Video Doorbell - FCC ID 2AQ7B-IPB239 - Shenzhen Interthings Technology Co., Ltd.
2AQ7B-IPB239

Smart Video Doorbell

Jul 31, 2026

Equipment Class

DTS - Digital Transmission System
Smart PTZ Camera - FCC ID 2AQ7B-IPC267 - Shenzhen Interthings Technology Co., Ltd.
2AQ7B-IPC267

Smart PTZ Camera

Jul 30, 2026

Equipment Class

DTS - Digital Transmission System
Smart wall light camera - FCC ID 2AQ7B-IPL265 - Shenzhen Interthings Technology Co., Ltd.
2AQ7B-IPL265

Smart wall light camera

Jul 13, 2026

Equipment Class