FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Interthings Technology Co., Ltd./
  3. 2AQ7B-PF326

2AQ7B-PF326Digital Frame

Shenzhen Interthings Technology Co., Ltd.
Digital Frame - FCC ID 2AQ7B-PF326 - Shenzhen Interthings Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 20, 2026
Application Purpose
Original Equipment
Equipment Note
Digital Frame
Frequency Range
2412.00000000 - 2462.00000000
Company
Shenzhen Interthings Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 PF326QA DigitalPhotoFrameUserManual 2 TABLEOFCONTENTS FrameOverview_________________________________________________________________________3 Gettingstarted__________________________________________________________________________4 Frameoapp__________________________________________________________________________4 Frameoquicksetup______________________________________________________________________5 StartusingFrameo_______________________________________________________________________5 Connectinganewfriend____________________________________________________________5 NavigatingyourFrameo___________________________________________________________________6 Thequickmenu___________________________________________________________________6 Slideshowactions__________________________________________________________________7 Fullscreencalendar________________________________________________________________9 Settings________________________________________________________________________________9 Myframe________________________________________________________________________9 Managephotos__________________________________________________________________10 Myfriends______________________________________________________________________12 Display_________________________________________________________________________13 Slideshow_______________________________________________________________________13 Calendar________________________________________________________________________15 Calendardetailssettings___________________________________________________________16 Wi-Fi___________________________________________________________________________17 Notifications_____________________________________________________________________17 BackupandRestore_______________________________________________________________18 Help___________________________________________________________________________19 About__________________________________________________________________________20 Privacy________________________________________________________________________________20 Support_______________________________________________________________________________20 Warranty,Compliance,SupportandSafetyinformation________________________________________21 3 FrameOverview 1.PowerButton ●Pressthepowerbuttontopowerontheframe,theLEDlightwillbeonwiththesystem. ●Whentheframeoappison,pressthepowerbuttononcetoturnoffLEDlighton,pressitagain toturnthelighton. ●Holdthepowerbuttonforabout2secondstogetPowerOptionsMenu.Toavoidanypossible damagetotheframe,pleasedonotunplugthepoweradapterfromtheframewhilethedevice ison. 2.RESET 3.TFCardSlot TFcardscanbeusedtoimportphotostotheframe.PhotoscanalsobeexportedtoaTFcardfrom theframeotomakeabackupormovetoacomputer,etc.Notethatphotoscannotbedisplayed directlyfromaTFcard. 4.Type-C 5.WallMountingHole 6.LEDLight Defaultonwiththesystem,userscanpressthepowerbuttontoturnon/offtheLEDlight. 7.Speaker 8.Bracket 4 Gettingstarted CongratulationsonyourbrandnewFrameophotoframe! IfyouarenewtousingFrameothenstartbyfollowingtheFrameoquicksetuporfollowthe on-screenguidewhenpoweringitonforthefirsttime. OnceyouhavesetupyourFrameoframe,youcanstartconnectingittoyourfriendsandfamily. Frameoapp Tosendphotostoyourframe,usetheFrameoappforiOSorAndroid. Scancodetofindtheapp Videotutorials Checkoutour“FrameoTutorials”playlistonYouTubewith informativevideoswhereweguideyouonhowtogetstartedusing Frameo.Scanthecodetotherightorusethelinktofindtheplaylist. bit.ly/3zKtxWX 5 Frameoquicksetup Whenstartingyourframeforthefirsttime,youwillneedtosetuptheframe. ● Selectalanguage.ThiswillbethelanguageusedontheFrameo. ●ConnectyourframetotheinternetbyconnectingittoWi-Fi. ●Verifyorcorrectthedateandtime. ●Frameomayaskyoutoupdatetothelatestversion.Itisrecommendedtoupdateyour framebeforecontinuingifaskedto. ● Enteryourname,andthelocationwhereyouhaveplacedyourframe,e.g.“JohnDoe”and “Livingroom”,“Kitchen”or“Office”.Finally,setthetimezoneifnotalreadycorrect. StartusingFrameo ThenextstepistoconnectFrameowithyourfriendsandfamilybyprovidingthemwithacode fromyourframe. Ifyouwanttobeabletosendphotostotheframeyourself,startbydownloadingtheappforiOS orAndroidonAppStoreorGooglePlay.Thenusethecodetoconnectyourframeandappas describedbelow. Connectinganewfriend MakesurethatyourfriendhasdownloadedandinstalledtheFrameoapp. Clicktheaddfriendicononyourframe.Adialogwillappearshowingaconnectioncode, whichisvalidfor12hours. Nowsharethiscodeinwhateverfashionyouprefere.g.SMS,E-Mail,IM,phonecall,toyour friend. OnceyourfriendshaveaddedthecodeintheirFrameoapp,theywillautomaticallyappearon yourframeandbeabletosendyouphotos. ReadchapterChangeoptionsforafriendtoallowconnectedfriendstoretrieveandsharethe connectioncodeviathesmartphoneapp.IfaconnectedfriendissubscribedtoFrameo + ,youcan alsoallowthemtoviewandmanagetheframe’scontentorperformabackupofyourmediaand settings. 6 NavigatingyourFrameo Swipeleftorrighttogothroughyourphotos. Thequickmenu Toaccessthequickmenu,simplytaponceonthescreen. Inthemenuyouwillfindthemostusedfeatures. Wi-Fi OpensWi-Fimenu.AlsodisplaysthenameofthecurrentWi-Fiyouareconnectedto,ifany. Albumselector Aquickmenutoselectwhatalbumtoplayormanageyouralbums. Powermenu OpensthePowermenu. Mycalendar Opensthefull-screencalendar,whereyoucanswitchbetweendifferentviews,addfriendsor acalendar,andaccessaquickguidetohelpyougetstartedusingthecalendaronyourframe. Myphotos OpensAllphotos. Addfriend Thiswillgenerateacodethatyoucansharewithyourfriendsandfamilysotheycanconnectand sendphotostoyourframe. Settings OpenstheSettings. Addtoalbum 7 Addsthephotocurrentlybeingdisplayedtoanalbumofchoice. Adjustphoto Allowsyoutoadjustthepositionofthephotointheframeforanevenbetterfit.Hereyoucanalso usetorotateyourphoto,andyoucanusetoeditthecaptiononimportedphotos.For receivingphotos,pleaseaskthesendertoeditthecaptionintheFrameoapp. Fillframeoptionisthedefault.Thephotoisscaledsothatitfillsthewholescreen.Itwillbe centeredaroundwhatisselectedasthemostimportantpart.Seethefirstpict…

Text truncated - open the document above for the full version.

RF Exposure Info

ReportNo.EDG2607060229E00102RPage1of7Ver.1.0 $二维码$ TESTREPORT ProductName:DigitalFrame ModelNumber: PF326,ONNDTFRM10-WHT, ONNDTFRM10-BLK,36025939-BLK, 36025939-WHT,36025939 FCCID:2AQ7B-PF326 Preparedfor:ShenzhenInterthingsTechnologyCo.,Ltd. Address:701,Building1,LechuanghuiBuilding,No.1211 GuanguangRoad,LonghuaDistrict,Shenzhen,China Preparedby:EMTEK(DONGGUAN)CO.,LTD. Address:1&2/F.,Building2,ZoneA,ZhongdaMarine BiotechnologyResearchandDevelopmentBase,No.9, XinchengAvenue,SongshanhuHigh-technology IndustrialDevelopmentZone,Dongguan,Guangdong, China TEL:+86-0769-22807078 FAX:+86-0769-22807079 ReportNumber:EDG2607060229E00102R Dateofsamplereceipt:July06,2026 Date(s)ofTests:July06,2026toAugust09,2026 Dateofissue:August10,2026 $二维码$ ReportNo.EDG2607060229E00102RPage2of7Ver.1.0 TableofContents 1.TESTRESULTCERTIFICATION...............................................................................................................................................3 2.EUTSPECIFICATION.................................................................................................................................................................5 3.TESTREQUIREMENT:...............................................................................................................................................................6 RFEXPOSUREEVALUATION...................................................................................................................................................6 4.MEASUREMENTRESULT.........................................................................................................................................................7 ReportNo.EDG2607060229E00102RPage3of7Ver.1.0 1.TESTRESULTCERTIFICATION Applicant:ShenzhenInterthingsTechnologyCo.,Ltd. Address: 701,Building1,LechuanghuiBuilding,No.1211GuanguangRoad,Longhua District,Shenzhen,China Manufacturer:YIBINYINGTONGINTELLIGENTTECHNOLOGYCO.,LTD. Address: Bldg19,IndustrialInnovationBaseInfrastructureProject(PhaseI),No.7West GangyuanRd,GuoxingAve,LingangETZ,Yibin,Sichuan,China Factory:YIBINYINGTONGINTELLIGENTTECHNOLOGYCO.,LTD. Address: Bldg19,IndustrialInnovationBaseInfrastructureProject(PhaseI),No.7West GangyuanRd,GuoxingAve,LingangETZ,Yibin,Sichuan,China EUT:DigitalFrame ModelName: PF326,ONNDTFRM10-WHT,ONNDTFRM10-BLK,36025939-BLK, 36025939-WHT,36025939 Trademark:N/A MeasurementProcedureUsed: APPLICABLESTANDARDS STANDARDTESTRESULT §15.247(i),§2.1091 PASS TheaboveequipmentwastestedbyEMTEK(DONGGUAN)CO.,LTD.Thetestdata,dataevaluation,test procedures,andequipmentconfigurationsshowninthisreportweremadeinaccordancewiththeprocedures giveninANSIC63.10(2020)andtheenergyemittedbythesampleEUTtestedasdescribedinthisreportisin compliancewiththerequirementsofFCCRules FCC§15.247(i),§2.1091 . Thetestresultsofthisreportrelateonlytothetestedsampleidentifiedinthisreport DateofTest:July06,2026toAugust09,2026 Preparedby: JessicaZhang/Editor Reviewer: WarrenDeng/Supervisor Approve&AuthorizedSigner: SamLv/Manager ReportNo.EDG2607060229E00102RPage4of7Ver.1.0 ModifiedHistory VersionReportNo.RevisionDateSummary EDG2607060229E00102R/OriginalReport ReportNo.EDG2607060229E00102RPage5of7Ver.1.0 2. EUTSpecification CharacteristicsDescription Product:DigitalFrame ModelNumber: PF326,ONNDTFRM10-WHT,ONNDTFRM10-BLK,36025939-BLK, 36025939-WHT,36025939 (Note:Thesemodelsarethesame,exceptforthemodelnumberand color;PF326wasselectedforfulltest.) Sample:E2607060229-01 DeviceType: 2.4GWIFI DataRate: 802.11b 802.11g 802.11n(20MHzchannelbandwidth) 802.11n(40MHzchannelbandwidth) 802.11ax(20MHzchannelbandwidth) 802.11ax(40MHzchannelbandwidth) Modulation: DSSSwithDBPSK/DQPSK/CCKfor802.11b; OFDMwithBPSK/QPSK/16QAM/64QAMfor802.11g/n; OFDMwithBPSK/QPSK/16QAM/64QAM/256QAM/1024QAMfor802.11ax; OperatingFrequency Range(s): 2412-2462MHzfor802.11b/g/n(HT20)/ax(HE20); 2422-2452MHzfor802.11n(HT40)/ax(HE40); NumberofChannels: 11channelsfor802.11b/g/n(HT20)/ax(HE20); 7Channelsfor802.11n(HT40)/ax(HE40); TransmitPowerMax: 12.26dBm(0.016827W) AntennaType:FPCAntenna AntennaGain: 2.2dBi PowerSupply: DC5Vfromadapter Adapter:Model:YTY-12F-0105100US INPUT:100-240V~50/60Hz0.3AMax Output:5V ⎓ 2000mA Evaluationapplied:MPEEvaluation SAREvaluation ReportNo.EDG2607060229E00102RPage6of7Ver.1.0 3. TestRequirement: RFEXPOSUREEVALUATION AccordingtoFCC1.1310:Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironment impactofhumanexposuretoradiofrequency(RF)Radiationasspecifiedin§1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) Power Density(mW/cm 2 ) Average Time (A)LimitsforOccupational/ControlExposures 300-1500----F/3006 1500-100000----56 (B)LimitsforGeneralPopulation/UncontrolExposures 300-1500----F/15006 1500-100000----130 Friistransmissionformula:Pd=(Pout*G)\(4*pi*R2) Where Pd=PowerdensityinmW/cm 2 Pout=outputpowertoantennainmW G=Numericgainoftheantennarelativetoisotropicantenna Pi=3.1416 R=distancebetweenobservationpointandcenteroftheradiatorin20cm PdthelimitofMPE,1mW/cm 2 .Ifweknowthemaximumgainofthendtotalpowerinputtotheantenna,through thecalculation,wewillknowthedistancewheretheMPElimitisreached. ReportNo.EDG2607060229E00102RPage7of7Ver.1.0 4. MeasurementResult Antennagain: 2.4G:2.2dBi Channel Freq. (MHz) modulation conducted power Tune-up power (dBm) MaxAntenna Evaluation result Power density Limits (dBm) tune-uppowerGain (mW/cm2)(mW/cm2) (dBm)(mW)(dBi)Numeric 2412 11B 12.0212±11319.9532.221.6670.00661 243711.4711±11215.8492.221.6670.00531 246212.2612±11319.9532.221.6670.00661 2412 11G 11.1011±11215.8492.221.6670.00531 243710.4210±11112.5892.221.6670.00421 246210.3810±11112.5892.221.6670.00421 2412 11N20SISO 10.4910±11112.5892.221.6670.00421 243710.1110±11112.5892.221.6670.00421 246210.3310±11112.5892.221.6670.00421 2422 11N40SISO 11.0511±11215.8492.221.6670.00531 243710.7110±11112.5892.221.6670.00421 245210.8111±11215.8492.221.6670.00531 2412 11AX20SISO 10.7510±11112.5892.221.6670.00421 24379.769±11010…

Text truncated - open the document above for the full version.

Test Setup Photos

ReportNo.EDG2607060229E001Page1of2Ver.1.0 FCCID:2AQ7B-PF326 ReportNo.EDG2607060229E001Page2of2Ver.1.0

Test Report

ReportNo.EDG2607060229E00101RPage86of110Ver.1.0 11AX40SISO-Ant1-2437-1000~26500-PASS 11AX40SISO-Ant1-2452-0~Reference-PASS ReportNo.EDG2607060229E00101RPage87of110Ver.1.0 11AX40SISO-Ant1-2452-30~1000-PASS 11AX40SISO-Ant1-2452-1000~26500-PASS ReportNo.EDG2607060229E00101RPage88of110Ver.1.0 TestModeAntennaChNameFrequency[MHz]RefLevel[dBm]Result[dBm]Limit[dBm]Verdict 11BAnt1Low24122.84-35.23≤-27.16PASS 11BAnt1High24623.51-48.17≤-26.49PASS 11GAnt1Low24120.68-36.41≤-29.33PASS 11GAnt1High2462-2.15-48.64≤-32.15PASS 11N20SISOAnt1Low2412-0.36-37.47≤-30.36PASS 11N20SISOAnt1High2462-1.38-48.26≤-31.38PASS 11N40SISOAnt1Low2422-2.89-35.62≤-32.89PASS 11N40SISOAnt1High2452-2.37-42.79≤-32.37PASS 11AX20SISOAnt1Low24120.22-30.33≤-29.78PASS 11AX20SISOAnt1High24620.31-48.42≤-29.69PASS 11AX40SISOAnt1Low2422-2.69-37.76≤-32.69PASS 11AX40SISOAnt1High2452-2.86-44.88≤-32.86PASS ReportNo.EDG2607060229E00101RPage89of110Ver.1.0 11B-Ant1-2412-PASS 11B-Ant1-2462-PASS ReportNo.EDG2607060229E00101RPage90of110Ver.1.0 11G-Ant1-2412-PASS 11G-Ant1-2462-PASS ReportNo.EDG2607060229E00101RPage91of110Ver.1.0 11N20SISO-Ant1-2412-PASS 11N20SISO-Ant1-2462-PASS ReportNo.EDG2607060229E00101RPage92of110Ver.1.0 11N40SISO-Ant1-2422-PASS 11N40SISO-Ant1-2452-PASS ReportNo.EDG2607060229E00101RPage93of110Ver.1.0 11AX20SISO-Ant1-2412-PASS 11AX20SISO-Ant1-2462-PASS ReportNo.EDG2607060229E00101RPage94of110Ver.1.0 11AX40SISO-Ant1-2422-PASS 11AX40SISO-Ant1-2452-PASS ReportNo.EDG2607060229E00101RPage95of110Ver.1.0 8.6RADIATEDSPURIOUSEMISSION 8.6.1ApplicableStandard AccordingtoFCCPart15.247(d),15.205,15.209andKDB558074D0115.247MeasGuidancev05r02 AccordingtoICRSS-GenandRSS-247 8.6.2ConformanceLimit AccordingtoFCCPart15.247(d):radiatedemissionswhichfallintherestrictedbands,asdefinedin §15.205(a),mustalsocomplywiththeradiatedemissionlimitsspecifiedin§15.209(a)(see§15.205(c)). AccordingtoFCCPart15.205,Restrictedbands MHzMHzMHzGHz 0.090-0.11016.42-16.423399.9-4104.5-5.15 10.495-0.50516.69475-16.69525608-6145.35-5.46 2.1735-2.190516.80425-16.80475960-12407.25-7.75 4.125-4.12825.5-25.671300-14278.025-8.5 4.17725-4.1777537.5-38.251435-1626.59.0-9.2 4.20725-4.2077573-74.61645.5-1646.59.3-9.5 6.215-6.21874.8-75.21660-171010.6-12.7 6.26775-6.26825123-1382200-230014.47-14.5 8.291-8.294149.9-150.052310-239015.35-16.2 8.362-8.366156.52475-156.525252483.5-250017.7-21.4 8.37625-8.38675156.7-156.92690-290022.01-23.12 8.41425-8.41475162.0125-167.173260-326723.6-24.0 12.29-12.293167.72-173.23332-333931.2-31.8 12.51975-12.52025240-2853345.8-335836.43-36.5 12.57675-12.57725322-335.43600-4400(2) 13.36-13.41 AccordingtoFCCPart15.205thelevelofanytransmitterspuriousemissioninRestrictedbandsshallnot exceedtheleveloftheemissionspecifiedinthefollowingtable Restricted Frequency(MHz) FieldStrength(μV/m)FieldStrength (dBμV/m) Measurement Distance 0.009-0.4902400/F(KHz)20log(uV/m)300 0.490-1.70524000/F(KHz)20log(uV/m)30 1.705-303029.530 30-88100403 88-21615043.53 216-960200463 Above960500543 8.6.3TestConfiguration Testaccordingtoclause6.2radiofrequencytestsetup 8.6.4TestProcedure ThistestisrequiredforanyspuriousemissionthatfallsinaRestrictedBand,asdefinedinSection15.205. ItmustbeperformedwiththehighestgainofeachtypeofantennaproposedforusewiththeEUT.Use thefollowingspectrumanalyzersettings: ForAbove1GHz: TheEUTwasplacedonaturntablewhichis1.5mabovegroundplane. MaximumprocedurewasperformedonthehighestemissionstoensureEUTcompliance. Span=wideenoughtofullycapturetheemissionbeingmeasured RBW=1MHz VBWRBW Sweep=auto Detectorfunction=peak Trace=maxhold ReportNo.EDG2607060229E00101RPage96of110Ver.1.0 ForBelow1GHz: TheEUTwasplacedonaturntablewhichis0.8mabovegroundplane. MaximumprocedurewasperformedonthehighestemissionstoensureEUTcompliance. Span=wideenoughtofullycapturetheemissionbeingmeasured RBW=100kHzfor VBW  RBW Sweep=auto Detectorfunction=peak Trace=maxhold ForBelow30MHz: TheEUTwasplacedonaturntablewhichis0.8mabovegroundplane. MaximumprocedurewasperformedonthehighestemissionstoensureEUTcompliance. Span=wideenoughtofullycapturetheemissionbeingmeasured RBW=9kHz VBW  RBW Sweep=auto Detectorfunction=peak Trace=maxhold ForBelow150KHz: TheEUTwasplacedonaturntablewhichis0.8mabovegroundplane. MaximumprocedurewasperformedonthehighestemissionstoensureEUTcompliance. Span=wideenoughtofullycapturetheemissionbeingmeasured RBW=200Hz VBW  RBW Sweep=auto Detectorfunction=peak Trace=maxhold FollowtheguidelinesinANSIC63.10withrespecttomaximizingtheemissionbyrotatingtheEUT, measuringtheemissionwhiletheEUTissituatedinthreeorthogonalplanes(ifappropriate),adjustingthe measurementantennaheightandpolarization,etc.Apre-ampandahighpassfilterarerequiredforthis test,inordertoprovidethemeasuringsystemwithsufficientsensitivity.Allowthetracetostabilize. Thepeakreadingoftheemission,afterbeingcorrectedbytheantennafactor,cableloss,pre-ampgain, etc.,isthepeakfieldstrength,whichmustcomplywiththelimit.Submitthisdata. NowsettheVBWto10Hz,whilemaintainingalloftheotherinstrumentsettings.Thispeaklevel,once corrected,mustcomplywiththelimit.Ifthedwelltimeperchannelofthehoppingsignalislessthan100 ms,thenthereadingobtainedwiththe10HzVBWmaybefurtheradjustedbya“dutycyclecorrection factor”,derivedfrom20log(dwelltime/100ms),inanefforttodemonstratecompliancewiththelimit. Submitthisdata. Repeataboveproceduresuntilallfrequencymeasuredwascomplete. 8.6.5TestResults Temperature: 26C RelativeHumidity: 54  ATMPressure:1011mbar SpuriousEmissionbelow30MHz(9KHzto30MHz) Freq. (MHz) Ant.Pol. Emission Level(dBuV/m) Limit3m(dBuV/m)Over(dB) H/VPKAVPKAVPKAV ---------------- Note:theamplitudeofspuriousemissionthatisattenuatedbymorethan20dBbelowthepermissible limithasnoneedtobereported. Distanceextrapolationfactor=40log(Specificdistance/testdistance)(dB); Limitline=Specificlimits(dBuV)+distanceextrapolationfactor ReportNo.EDG2607060229E00101RPage97of110Ver.1.0 SpuriousEmissionAbove1GHz(1GHzto25GHz) Alltheantenna(Antenna1)andmodes(802.11b/g/n/ax)havebeentestedandtheworst(Antenna1, 802.11b)resultrecordedwasreportasbelow: Testmode:802.11bFrequency:…

Text truncated - open the document above for the full version.

Test Report

ReportNo.EDG2607060229E00101RPage76of110Ver.1.0 11N40SISO-Ant1-2437-0~Reference-PASS 11N40SISO-Ant1-2437-30~1000-PASS ReportNo.EDG2607060229E00101RPage77of110Ver.1.0 11N40SISO-Ant1-2437-1000~26500-PASS 11N40SISO-Ant1-2452-0~Reference-PASS ReportNo.EDG2607060229E00101RPage78of110Ver.1.0 11N40SISO-Ant1-2452-30~1000-PASS 11N40SISO-Ant1-2452-1000~26500-PASS ReportNo.EDG2607060229E00101RPage79of110Ver.1.0 11AX20SISO-Ant1-2412-0~Reference-PASS 11AX20SISO-Ant1-2412-30~1000-PASS ReportNo.EDG2607060229E00101RPage80of110Ver.1.0 11AX20SISO-Ant1-2412-1000~26500-PASS 11AX20SISO-Ant1-2437-0~Reference-PASS ReportNo.EDG2607060229E00101RPage81of110Ver.1.0 11AX20SISO-Ant1-2437-30~1000-PASS 11AX20SISO-Ant1-2437-1000~26500-PASS ReportNo.EDG2607060229E00101RPage82of110Ver.1.0 11AX20SISO-Ant1-2462-0~Reference-PASS 11AX20SISO-Ant1-2462-30~1000-PASS ReportNo.EDG2607060229E00101RPage83of110Ver.1.0 11AX20SISO-Ant1-2462-1000~26500-PASS 11AX40SISO-Ant1-2422-0~Reference-PASS ReportNo.EDG2607060229E00101RPage84of110Ver.1.0 11AX40SISO-Ant1-2422-30~1000-PASS 11AX40SISO-Ant1-2422-1000~26500-PASS ReportNo.EDG2607060229E00101RPage85of110Ver.1.0 11AX40SISO-Ant1-2437-0~Reference-PASS 11AX40SISO-Ant1-2437-30~1000-PASS

Test Report

ReportNo.EDG2607060229E00101RPage56of110Ver.1.0 11AX20SISO-Ant1-2412-PASS 11AX20SISO-Ant1-2437-PASS ReportNo.EDG2607060229E00101RPage57of110Ver.1.0 11AX20SISO-Ant1-2462-PASS 11AX40SISO-Ant1-2422-PASS ReportNo.EDG2607060229E00101RPage58of110Ver.1.0 11AX40SISO-Ant1-2437-PASS 11AX40SISO-Ant1-2452-PASS ReportNo.EDG2607060229E00101RPage59of110Ver.1.0 8.5UNWANTEDEMISSIONSINNON-RESTRICTEDFREQUENCYBANDS 8.5.1ApplicableStandard AccordingtoFCCPart15.247(d)andKDB558074D0115.247MeasGuidancev05r02 AccordingtoRSS-2476.6 8.5.2ConformanceLimit AccordingtoFCCPart15.247(d): Inany100kHzbandwidthoutsidethefrequencybandinwhichthespreadspectrumordigitally modulateddeviceisoperating,theRFpowerthatisproducedshallbeatleast20dBbelowthatinthe100 kHzbandwidthwithinthebandthatcontainsthehighestlevelofthedesiredpower,basedoneitheranRF conductedoraradiatedmeasurement,providedthatthetransmitterdemonstratescompliancewiththe peakconductedpowerlimits.Ifthetransmittercomplieswiththeconductedpowerlimitsbasedontheuse ofroot-mean-squareaveragingoveratimeinterval,aspermittedundersection5.4(d),theattenuation requiredshallbe30dBinsteadof20dB.Attenuationbelowthegeneralfieldstrengthlimitsspecified inRSS-Genisnotrequired. 8.5.3TestConfiguration Testaccordingtoclause6.1radiofrequencytestsetup 8.5.4TestProcedure Thetransmitteroutput(antennaport)wasconnectedtothespectrumanalyzer Referencelevelmeasurement Establishareferencelevelbyusingthefollowingprocedure: SetinstrumentcenterfrequencytoDTSchannelcenterfrequency. Setthespanto≥1.5timestheDTSbandwidth. SettheRBW=100kHz. SettheVBW≥3xRBW. SetDetector=peak. SetSweeptime=autocouple. SetTracemode=maxhold. Allowtracetofullystabilize. UsethepeakmarkerfunctiontodeterminethemaximumPSDlevel. NotethatthechannelfoundtocontainthemaximumPSDlevelcanbeusedtoestablishthereference level. Band-edgemeasurement Usethefollowingspectrumanalyzersettings: Span=wideenoughtocapturethepeakleveloftheemissionoperatingonthechannelclosesttothe band-edge,aswellasanymodulationproductswhichfalloutsideoftheauthorizedbandofoperation SetRBW  1%ofthespan=100kHzSetVBW  3xRBW SetSweep=autoSetDetectorfunction=peakSetTrace=maxhold Allowthetracetostabilize.Setthemarkerontheemissionatthebandedge,oronthehighest modulationproductoutsideoftheband,ifthislevelisgreaterthanthatatthebandedge.Enablethe marker-deltafunction,thenusethemarker-to-peakfunctiontomovethemarkertothepeakofthein-band emission.Themarker-deltavaluenowdisplayedmustcomplywiththelimitspecifiedinthisSection. Emissionlevelmeasurement Setthecenterfrequencyandspantoencompassfrequencyrangetobemeasured. SettheRBW=100kHz. SettheVBW=300kHz. SetDetector=peak Sweeptime=autocouple. Tracemode=maxhold. Allowtracetofullystabilize. Usethepeakmarkerfunctiontodeterminethemaximumamplitudelevel. Ensurethattheamplitudeofallunwantedemissionsoutsideoftheauthorizedfrequencyband(excluding restrictedfrequencybands)areattenuatedbyatleasttheminimumrequirements.Reportthethree highestemissionsrelativetothelimit. ReportNo.EDG2607060229E00101RPage60of110Ver.1.0 8.5.5TestResults Temperature: 25 ̊ C RelativeHumidity: 45  ATMPressure:1011mbar Note:N/A TestModeAntennaFrequency[MHz] FreqRange [Mhz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict 11BAnt124120~Reference2.282.28---PASS 11BAnt1241230~10002.28-60.85≤-27.72PASS 11BAnt124121000~265002.28-37.14≤-27.72PASS 11BAnt124370~Reference0.880.88---PASS 11BAnt1243730~10000.88-60.92≤-29.12PASS 11BAnt124371000~265000.88-36.19≤-29.12PASS 11BAnt124620~Reference2.322.32---PASS 11BAnt1246230~10002.32-61.27≤-27.68PASS 11BAnt124621000~265002.32-35.75≤-27.68PASS 11GAnt124120~Reference-0.96-0.96---PASS 11GAnt1241230~1000-0.96-61.51≤-30.96PASS 11GAnt124121000~26500-0.96-50.51≤-30.96PASS 11GAnt124370~Reference-2.91-2.91---PASS 11GAnt1243730~1000-2.91-62.03≤-32.91PASS 11GAnt124371000~26500-2.91-49.68≤-32.91PASS 11GAnt124620~Reference-2.40-2.40---PASS 11GAnt1246230~1000-2.40-60.64≤-32.4PASS 11GAnt124621000~26500-2.40-47.65≤-32.4PASS 11N20SISOAnt124120~Reference-0.54-0.54---PASS 11N20SISOAnt1241230~1000-0.54-61.91≤-30.54PASS 11N20SISOAnt124121000~26500-0.54-50.75≤-30.54PASS 11N20SISOAnt124370~Reference-0.94-0.94---PASS 11N20SISOAnt1243730~1000-0.94-61.65≤-30.94PASS 11N20SISOAnt124371000~26500-0.94-50.81≤-30.94PASS 11N20SISOAnt124620~Reference-0.11-0.11---PASS 11N20SISOAnt1246230~1000-0.11-62.01≤-30.11PASS 11N20SISOAnt124621000~26500-0.11-48.88≤-30.11PASS 11N40SISOAnt124220~Reference-6.03-6.03---PASS 11N40SISOAnt1242230~1000-6.03-61.81≤-36.03PASS 11N40SISOAnt124221000~26500-6.03-51.18≤-36.03PASS 11N40SISOAnt124370~Reference-5.35-5.35---PASS 11N40SISOAnt1243730~1000-5.35-61.04≤-35.35PASS 11N40SISOAnt124371000~26500-5.35-50.8≤-35.35PASS 11N40SISOAnt124520~Reference-3.57-3.57---PASS 11N40SISOAnt1245230~1000-3.57-62.37≤-33.57PASS 11N40SISOAnt124521000~26500-3.57-50.81≤-33.57PASS 11AX20SISOAnt124120~Reference-3.57-3.57---PASS 11AX20SISOAnt1241230~1000-3.57-62.08≤-33.57PASS 11AX20SISOAnt124121000~26500-3.57-51.03≤-33.57PASS 11AX20SISOAnt124370~Reference-3.56-3.56---PASS 11AX20SISOAnt1243730~1000-3.56-61.48≤-33.56PASS 11AX20SISOAnt124371000~26500-3.56-49.53≤-33.56PASS 11AX20SISOAnt124620~Reference-2.68-2.68---PASS 11AX20SISOAnt1246230~1000-2.68-62.08≤-32.68PASS 11AX20SISOAnt124621000~26500-2.68-50.67≤-32.68PASS 11AX40SISOAnt124220~Reference-5.76-5.76---PASS 11AX40SISOAnt1242230~1000-5.76-62.21≤-35.76PASS 11AX40SISOAnt124221000~26500-5.76-50.65≤-35.76PASS 11AX40SISOAnt124370~Reference-6.28-6.28---PASS 11AX40SISOAnt1243730~1000-6.28-61.46≤-36.28PASS ReportNo.EDG2607060229E00101RPage61of110Ver.1.0 11AX40SISOAnt124371000~26500-6.28-50.82≤-36.28PASS 11AX40SISOAnt124520~Reference-3.64-3.64---PASS 11AX40SISOAnt1245230~1000-3.64-61.92≤-33.64PASS 11AX40SISOAnt124521000~26500-3.64-51.11≤-33.64PASS 11B-Ant1-2412-0~Reference-PASS 11B-Ant1-2412-30~1000-PASS ReportNo.EDG2607060229E00101RPage62of110Ver.1.0 11B-Ant1-2412-1000~26500-PASS 11B-Ant1-2437-0~Reference-PASS ReportNo.EDG2607060229E00101RPage63of110Ver.1.0 11B-Ant1-2437-30~1000-PASS 11B-Ant1-2437-1000~26500-PASS ReportNo.EDG2607060…

Text truncated - open the document above for the full version.

Test Report

ReportNo.EDG2607060229E00101RPage36of110Ver.1.0 11AX20SISO-Ant1-2462 11AX40SISO-Ant1-2422 ReportNo.EDG2607060229E00101RPage37of110Ver.1.0 11AX40SISO-Ant1-2437 11AX40SISO-Ant1-2452 ReportNo.EDG2607060229E00101RPage38of110Ver.1.0 8.3MAXIMUMPEAKCONDUCTEDOUTPUTPOWER 8.3.1ApplicableStandard AccordingtoFCCPart15.247(b)(3)andKDB558074D0115.247MeasGuidancev05r02 AccordingtoRSS-2476.3.2andRSS-Gen6.12 8.3.2ConformanceLimit Themaximumconductedoutputpoweroftheintentionalradiatorforsystemsusingdigitalmodulationin the2400-2483.5MHzbandsshallnotexceed:1Watt(30dBm). 8.3.3TestConfiguration Testaccordingtoclause6.1radiofrequencytestsetup 8.3.4TestProcedure a)Setspantoatleast1.5timestheOBW. b)SetRBW=1-5%oftheOBW,nottoexceed1MHz. c)SetVBW≥3xRBW. d)Numberofpointsinsweep≥2×span/RBW.(Thisgivesbin-to-binspacing≤RBW/2,sothat narrowbandsignalsarenotlostbetweenfrequencybins.) e)Sweeptime=auto. f)Detector=RMS(i.e.,poweraveraging),ifavailable.Otherwise,usesampledetectormode. g)Iftransmitdutycycle<98%,useasweeptriggerwiththelevelsettoenabletriggeringonlyonfull powerpulses.Thetransmittershalloperateatmaximumpowercontrollevelfortheentiredurationof everysweep.IftheEUTtransmitscontinuously(i.e.,withnooffintervals)oratdutycycle≥98%,andif eachtransmissionisentirelyatthemaximumpowercontrollevel,thenthetriggershallbesetto“free run”. h)Traceaverageatleast100tracesinpoweraveraging(i.e.,RMS)mode. i)ComputepowerbyintegratingthespectrumacrosstheOBWofthesignalusingtheinstrument’sband powermeasurementfunction,withbandlimitssetequaltotheOBWbandedges.Iftheinstrumentdoes nothaveabandpowerfunction,sumthespectrumlevels(inpowerunits)atintervalsequaltotheRBW extendingacrosstheentireOBWofthespectrum. AccordingtoFCCPart15.247(b)(4): Conductedoutputpowerlimitspecifiedinparagraph(b)ofthissectionisbasedontheuseofantennas withdirectionalgainsthatdonotexceed6dBi.Iftransmittingantennasofdirectionalgaingreaterthan6 dBiareused,theconductedoutputpowerfromtheintentionalradiatorshallbereducedbelowthestated valuesinparagraphs(b)(3)ofthissection,asappropriate,bytheamountindBthatthedirectionalgainof theantennaexceeds6dBi. Note:IfantennaGainexceeds6dBi,thenOutputpowerLimit=30-(Gain-6) 8.3.5TestResults Temperature: 25 ̊C RelativeHumidity: 45  ATMPressure:1011mbar Note:N/A ReportNo.EDG2607060229E00101RPage39of110Ver.1.0 Test Mode Anten na Frequen cy[MHz] Average power [dBm] Duty Cycle [%] DC Factor [dBm] Result [dBm] Limit [dBm] Gain [dBi] EIRP [dBm] EIRP Limit [dBm] Verdict 11BAnt1241211.9798.790.0512.02≤30.002.2214.24≤36.00PASS 11BAnt1243711.4198.630.0611.47≤30.002.2213.69≤36.00PASS 11BAnt1246212.26100.000.0012.26≤30.002.2214.48≤36.00PASS 11GAnt1241210.7792.690.3311.10≤30.002.2213.32≤36.00PASS 11GAnt1243710.0792.270.3510.42≤30.002.2212.64≤36.00PASS 11GAnt1246210.0592.690.3310.38≤30.002.2212.6≤36.00PASS 11N20 SISO Ant1241210.49100.000.0010.49≤30.002.2212.71≤36.00PASS 11N20 SISO Ant124379.7692.200.3510.11≤30.002.2212.33≤36.00PASS 11N20 SISO Ant124629.9691.750.3710.33≤30.002.2212.55≤36.00PASS 11N40 SISO Ant1242210.3284.550.7311.05≤30.002.2213.27≤36.00PASS 11N40 SISO Ant1243710.0385.450.6810.71≤30.002.2212.93≤36.00PASS 11N40 SISO Ant1245210.1285.320.6910.81≤30.002.2213.03≤36.00PASS 11AX2 0SISO Ant1241210.2789.570.4810.75≤30.002.2212.97≤36.00PASS 11AX2 0SISO Ant124379.3190.060.459.76≤30.002.2211.98≤36.00PASS 11AX2 0SISO Ant124629.8390.120.4510.28≤30.002.2212.5≤36.00PASS 11AX4 0SISO Ant124229.9981.720.8810.87≤30.002.2213.09≤36.00PASS 11AX4 0SISO Ant124379.6282.420.8410.46≤30.002.2212.68≤36.00PASS 11AX4 0SISO Ant124529.8281.720.8810.70≤30.002.2212.92≤36.00PASS ReportNo.EDG2607060229E00101RPage40of110Ver.1.0 11B-Ant1-2412-PASS 11B-Ant1-2437-PASS ReportNo.EDG2607060229E00101RPage41of110Ver.1.0 11B-Ant1-2462-PASS 11G-Ant1-2412-PASS ReportNo.EDG2607060229E00101RPage42of110Ver.1.0 11G-Ant1-2437-PASS 11G-Ant1-2462-PASS ReportNo.EDG2607060229E00101RPage43of110Ver.1.0 11N20SISO-Ant1-2412-PASS 11N20SISO-Ant1-2437-PASS ReportNo.EDG2607060229E00101RPage44of110Ver.1.0 11N20SISO-Ant1-2462-PASS 11N40SISO-Ant1-2422-PASS ReportNo.EDG2607060229E00101RPage45of110Ver.1.0 11N40SISO-Ant1-2437-PASS 11N40SISO-Ant1-2452-PASS ReportNo.EDG2607060229E00101RPage46of110Ver.1.0 11AX20SISO-Ant1-2412-PASS 11AX20SISO-Ant1-2437-PASS ReportNo.EDG2607060229E00101RPage47of110Ver.1.0 11AX20SISO-Ant1-2462-PASS 11AX40SISO-Ant1-2422-PASS ReportNo.EDG2607060229E00101RPage48of110Ver.1.0 11AX40SISO-Ant1-2437-PASS 11AX40SISO-Ant1-2452-PASS ReportNo.EDG2607060229E00101RPage49of110Ver.1.0 8.4MAXIMUMPOWERSPECTRALDENSITY 8.4.1ApplicableStandard AccordingtoFCCPart15.247(e)andKDB558074D0115.247MeasGuidancev05r02 AccordingtoRSS-2476.3.1andRSS-Gen6.12 8.4.2ConformanceLimit Thetransmitterpowerspectraldensityconductedfromthetransmittertoth…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Lucy Fang(Manager)
[email protected]Fax: 86-755-21040734

Technical Contact

Global Product Services and Consultation LLCMichael Chan
[email protected]

328 W Palm Ave. · Monrovia, California, 91016 · United States

Test Firm

EMTEK (DONGGUAN) CO., LTD.Sam Lv
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz16.83 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum conducted output power. This device must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. This device supports 20 and 40 MHz modes.

Other Applications from Shenzhen Interthings Technology Co., Ltd.

Smart Two Way Security Camera - FCC ID 2AQ7B-IPC236 - Shenzhen Interthings Technology Co., Ltd.
2AQ7B-IPC236

Smart Two Way Security Camera

Aug 13, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
2AQ7B-IPB217

Smart Doorbell

Aug 03, 2026

Equipment Class

DTS - Digital Transmission System
Smart Video Doorbell - FCC ID 2AQ7B-IPB239 - Shenzhen Interthings Technology Co., Ltd.
2AQ7B-IPB239

Smart Video Doorbell

Jul 31, 2026

Equipment Class

DTS - Digital Transmission System
Smart PTZ Camera - FCC ID 2AQ7B-IPC267 - Shenzhen Interthings Technology Co., Ltd.
2AQ7B-IPC267

Smart PTZ Camera

Jul 30, 2026

Equipment Class

DTS - Digital Transmission System
Smart wall light camera - FCC ID 2AQ7B-IPL265 - Shenzhen Interthings Technology Co., Ltd.
2AQ7B-IPL265

Smart wall light camera

Jul 13, 2026

Equipment Class

DTS - Digital Transmission System