Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Scan the QR code for app download Scan the QR code for more languages KINGSMITH Trifold Water Rowing Machine WM10 User Manual Please read the user manual carefully before using the product. Keep it properly for future reference. Position to paste the nameplate Thank you for choosing the KINGSMITH Trifold Water Rowing Machine (hereinafter referred to as "the equipment", "the product", etc) . It is a speed training product. To ensure that you fully understand and use the product correctly, please read the following instructions carefully before use. DANGER - TO REDUCE THE RISK OF ELECTRICAL SHOCK: Always unplug the equipment from the electrical outlet immediately after using and before cleaning. WARNING - TO REDUCE THE RISK OF BURNS, FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS: 1) Equipment should never be left unattended when not in use, and before putting on or taking off parts. 2) Inspect the product for any signs of wear and tear prior to use. If you find any damage, contact customer service immediately. Do not use the product until the issue is resolved. 3) This equipment is only to be used by healthy and able-bodied adults. Close supervision is necessary when this equipment is used by, on, or near children, invalids, or disabled persons. 4) The equipment is intended for consumer and residential use only. Do not use it in a commercial or light- commercial setting or outdoors or medical treatment purpose. Do not use attachments not recommended by the manufacturer. 5) Never operate this equipment if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Contact customer service for examination and repair. 6) Do not carry this equipment by the supply cord or use cord as a handle. 7) Keep the cord away from heated sources. 8) Do not use attachments not recommended by the manufacturer. 9) Disconnect all power before servicing the product. 10) Do not operate where aerosol (spray) products are being used or where oxygen is being administered. 11) To disconnect, remove the plug from the outlet. 12) Connect this equipment to a properly grounded outlet only. 13) If you feel uncomfortable, please stop exercising immediately and consult a doctor to avoid damage to your health. 14) Ensure there is a distance of at least 4.92 feet (1.5 m) behind the equipment and a distance of at least 23.62 in. (600 mm) on other sides. 15) Wear appropriate athletic clothing to use the equipment and exercise according to your own condition. Do not exercise barefoot or in socks only. 16) Do not wear loose or dangling clothing while using the product. 17) Do not operate electrically powered equipment in damp or wet locations. 18) Do not stand or step on the head of the equipment. 19) Keep children away. Do not use this equipment with, near or around pets. 20) The elderly, children, and pregnant women Must use this product with caution. Please consult a doctor and obtain relevant guidance before using this equipment. 21) Do not fold this equipment when the power is on. Otherwise, it may affect the service life of the product and lead to other safety hazards. 22) Store the equipment as instructed in the manual for safety. 23) Do not exceed the maximum specified user weight. 24) Avoid exposing this equipment to direct sunlight. Keep it in a cool and dry place. 25) For optimal performance and stability, use the equipment on a level solid surface and ensure there are no obstructions underneath it. 26) The product is for ages 14 and up, single use only. 27) The safety level of the equipment can be maintained only if it's examined regularly for damage and repaired. 28) Replace defective components immediately and/or keep the equipment out of use until repair. 29) Our company is not liable for any personal injuries or property losses caused by improper use of this product. We reserve the right to update, revise, or terminate the user manual and related instructions without prior notice. Contents Product Introduction Operation and Adjustment Care and Maintenance Trademark and Legal Declaration Compliance Statement 01 05 12 13 14 Unpack the product and ensure all items are present. If anything is missing, please contact the seller. Product Introduction Product name Model Rated input Track Track length Nominal capacity Actual capacity Paddle Max user weight Net weight Operating temperature Power Adapter Input Output Trifold Water Rowing Machine RMWM10F 9.0V 1.0A Dual track 49.21 inches 1250 mm 25 L 15 L 4 blades 330 lb / 150 kg 79 lb / 36 kg 5~50 °C 100-240V~ 50/60Hz 0.6A MAX 9.0V 1.0A Unfolded size Folded size Class Age range Max resistance Resistance type Resistance range 81.49×18.89×22.83 inches 2070 mm×480 mm×580 mm 28.8×18.8×20.8 inches 735 mm×480 mm×580 mm For consumer use only 14 years and above 500 N Water & magnetic dual resistance Water resistance (5 levels) Magnetic resistance (32 levels) User manual×1 Water pump×1 Rowing machine×1 01 Packing List 02 Tech Specs Power adapter×1 Seat Folding handle Wheel Folded state Foot pad Grip bar 03 Part Names Unfolded state Phone holder Knob panel Pedal Fixed knob Rowing handle Foot strap Water filling nozzle Water tank Track Power socket Distance: 8.8 kmFat burn: 8.8 kcal Number of strokes: 88 Pace: 38 s/ 500 m 04 Knob Panel Functions Calories km km/h Time Distance Bluetooth Carousel indicator Speed Stroke rate Number of strokes Strokes/min 500m pace Resistance Stroke rate: 88 strokes/minResistance: 8 levelsCurrent speed: 8.8 km/h Workout time: 38 s Water Resistance Level 3 3 3 3 3 3 3 3 5 5 5 5 5 5 5 5 1 16 24 32 1 16 24 32 1 16 24 32 1 16 24 32 25 25 25 25 29 29 29 29 25 25 25 25 29 29 29 29 48.4 lb / 22 kg 55 lb / 25 kg 61.6 lb / 28 kg 72.6 lb / 33 kg 61.6 lb / 28 kg 70.4 lb / 32 kg 77 lb / 35 kg 83.6 lb / 38 kg 77 lb / 35 kg 83.6 lb / 38 kg 90.2 lb / 41 kg 99 lb / 45 kg 88 lb / 40 kg 96.8 lb / 44 kg 103.4 lb / 57 kg 110 lb / 50 kg Casual Fitness Casual Fitness Casual Fitness Body Shaping Casual Fitness Body Sha…
Text truncated - open the document above for the full version.
App Add Tel. E-m Dat FED Aut 743 Colu De a Ou r FCC supp by m Sin c Sign Ch e Qua plicant:Beijin dress: Floor :+86 010-8 3 mail:liwenso e: 2024-10- DERAL CO thorization a 5 Oakland M umbia, MD ar Sir or Ma r product:Tr C ID: 2AR portsBLE1M manufacture cerely Yours nature: engxiang Gu ality manag ng Kingsmit 4, Building 3680970 ng@kingsm -21 OMMUNICA and Evaluat Mills Road D 21046 adam, rifold Wate RDB-RMWM Mfunction er in the sof s, u er th Technolo 25, Area 18 mith.com.cn ATIONS C tion Divisio Atte er Rowing M10F, for m s, The other ftware, the e ogy Co., Ltd 8, ABP Park, COMMISSIO on estation le Machine, m marketing p r functions, end user has , Fengtai, Be ONS etter model: RM purpose, thi bands and s no capabil eijing, China WM10F, s product o n modes was lity to activ a nly disabled to vate it. o use
Applica Address Tel.:+8 E-mail: Date: 20 FEDE R Authori 7435 O Colum b Ref: A t FCC I D Beijin g sought i pursuan Sincer e Signatu Cheng x Quality ant:Beijing K s: Floor 4, B 6 010-8368 liwensong@ 024-10-21 RAL COMM ization and akland Mil l bia, MD 210 ttestation St D:2ARDB-R g Kingsmith is not “cove nt to section ely Yours, ure: xiangGu y manager Kingsmith T Building 25 80970 @kingsmith MUNICATI Evaluation ls Road 046 tatements C RMWM10F h Technolo ered” equip n 2.903 of th Technology , Area 18, A h.com.cn Att IONS COM Division FR 47 §2.9 F ogy Co., Ltd pment prohib he FCC rule y Co., Ltd ABP Park, F testation L MMISSIONS 11(d)(5)(i) dcertifies th bited from r es. Fengtai, Bei C Letter S Filing hat the equip receiving an ijing, China CFR 47 §2.91 pment for w n equipmen a 1(d)(5)(i) Atte which author nt authorizat estation Letter rization is tion r
Applica Address Tel.:+8 E-mail: Date: 20 FEDE R Authori 7435 O Colum b Ref: A t FCC I D Beijing the app l Sincer e Signatu Cheng x Quality ant:Beijing K s: Floor 4, B 6 010-8368 liwensong@ 024-10-21 RAL COMM ization and akland Mil l bia, MD 210 ttestation St D:2ARDB-R Kingsmith licant is not ely Yours, ure: xiang Gu y manager Kingsmith T Building 25 80970 @kingsmith MUNICATI Evaluation ls Road 046 tatements C RMWM10F Technolog t identified Technology , Area 18, A h.com.cn Att IONS COM Division FR 47 §2.9 F gy Co., Ltd c on the Cov y Co., Ltd ABP Park, F testation L MMISSIONS 11(d)(5)(ii) certifies tha vered List as Fengtai, Bei CF Letter S ) Filing at as of the d s an entity p ijing, China FR 47 §2.911 date of the f producing “c a (d)(5)(ii) Atte filing of the covered” eq estation Letter application quipment. r n,
U.S. AGENT LETTER OF ATTESTATION Date: 2024-10-21 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(7) Filing FCC ID: 2ARDB-RMWM10F Beijing Kingsmith Technology Co., Ltd certifies that, as of the date of the filing of the application, KINGSMITH TECHNOLOGY CORPORATION is our designated U.S. agent for service of process for the above referenced FCC ID. Beijing Kingsmith Technology Co., Ltd (“the Applicant”) accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. KINGSMITH TECHNOLOGY CORPORATION accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: KINGSMITH TECHNOLOGY CORPORATION Address: 5900 BALCONES DR STE 100AUSTIN TX 78731-4298 FRN: 0036203354 Tel.:+1 888-292-4009 Email: [email protected] Signed by (printed name): Signature: Applicant: Beijing Kingsmith Technology Co., Ltd Address: Floor 4, Building 25, Area 18, ABP Park, Fengtai, Beijing, China FRN: 0027877125 Tel: +86 010-83680970 Email: [email protected] Signed by (printed name): Chengxiang Gu Signature:
Applicant: Beijing Kingsmith Technology Co.,Ltd Address: Floor 4, Building 25, Area 18, ABP Park, Fengtai, Beijing, China Tel.: +86 010-83680970 E-mail: [email protected] QA-FR-170-B 7/29/2014 FCC Authorization Date: 2024-10-21 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We, Beijing Kingsmith Technology Co.,Ltd the undersigned, hereby authorizes Bay Area Compliance Laboratories Corp. (Shenzhen) to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corp. (Shenzhen) on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Signature: Chengxiang Gu Quality manager
Applicant: Beijing Kingsmith Technology Co.,Ltd Address: Floor 4, Building 25, Area 18, ABP Park, Fengtai, Beijing, China Tel.: +86 010-83680970 E-mail: [email protected] FCC Confidential Authorization Date: 2024-10-21 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2ARDB-RMWM10F In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Beijing Kingsmith Technology Co.,Ltd hereby requests long-term confidential treatment of information accompanying this application as outlined below: • Block Diagram • Schematics • Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely Yours, Signature: Chengxiang Gu Quality manager
Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401X40820E-RF Page 1 of 6 EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401X40820E-RF Page 2 of 6 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401X40820E-RF Page 3 of 6 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401X40820E-RF Page 4 of 6 Antenna Location Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401X40820E-RF Page 5 of 6 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401X40820E-RF Page 6 of 6
Label Here
Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401X40820E-RF Page 1 of 6 EXHIBIT C - EUT INTERNAL PHOTOGRAPHS Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401X40820E-RF Page 2 of 6 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401X40820E-RF Page 3 of 6 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401X40820E-RF Page 4 of 6 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401X40820E-RF Page 5 of 6 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401X40820E-RF Page 6 of 6
Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401X40820E-RF TR-EM-RF011 Page 13 of 64 Version 3.0 FCC§15.247 (i), §1.1307(b)(3)(i)(A)&§2.1093 - RF EXPOSURE Applicable Standard According to FCC §2.1093 and §1.1307(b)(3), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. According to KDB 447498 D04 Interim General RF Exposure Guidance 1-mW Test Exemption: Per § 1.1307(b)(3)(i)(A), a single RF source is exempt RF device (from the requirement to show data demonstrating compliance to RF exposure limits, as previously mentioned) if the available maximum time-averaged power is no more than 1 mW, regardless of separation distance. This exemption applies to all operating configurations and exposure conditions, for the frequency range 100 kHz to 100 GHz, regardless of fixed, mobile, or portable device exposure conditions. This is a standalone exemption, and it cannot be applied in conjunction with any other test exemption. Result For worst case: Mode Frequency (MHz) Antenna Gain # Maximum Tune up conducted power # ERP Exemption Limit (mW) Test Exemption dBm mW BLE 2402-2480 3.65 -23.00 -21.50 0.01 1 Yes Note: The maximum tune up conducted power # and antenna gain # was declared and provided by the applicant. Result: Compliant
Note: The information marked # is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP or any agency of the U.S. Government. This report may contain data that are not covered by the NVLAP accreditation and are marked with an asterisk “▼”. Bay Area Compliance Laboratories Corp. (Shenzhen) 5F(B-West) , 6F, 7F, the 3rd Phase of Wan Li Industrial Building D, Shihua Rd, FuTian Free Trade Zone, Shenzhen, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn TR-EM-RF011 Page 1 of 64 Version 3.0 TEST REPORT Applicant Name: Beijing Kingsmith Technology Co.,Ltd Address: Floor 4, Building 25, Area 18, ABP Park, Fengtai, Beijing, China Report Number: 2401X40820E-RF FCC ID: 2ARDB-RMWM10F IC: 25276-RMWM10F Test Standard (s) FCC PART 15.247; RSS-GEN ISSUE 5, FEBRUARY 2021 AMENDMENT 2; RSS-247 ISSUE 3, AUGUST 2023 Sample Description Product Type: Trifold Water Rowing Machine Model No.: RMWM10F Multiple Model(s) No.: N/A Trade Mark: N/A Date Received: 2024/10/08 Issue Date: 2024/11/20 Test Result: Pass ▲ ▲ In the configuration tested, the EUT complied with the standards above. Prepared and Checked By: Approved By: Kungfumaster Liang Michelle Zeng RF Engineer RF Supervisor Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401X40820E-RF TR-EM-RF011 Page 2 of 64 Version 3.0 TABLE OF CONTENTS DOCUMENT REVISION HISTORY ......................................................................................................................... 4 GENERAL INFORMATION ....................................................................................................................................... 5 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 5 OBJECTIVE ................................................................................................................................................................... 5 TEST METHODOLOGY .................................................................................................................................................. 5 MEASUREMENT UNCERTAINTY .................................................................................................................................... 6 TEST FACILITY ............................................................................................................................................................. 6 SYSTEM TEST CONFIGURATION .......................................................................................................................... 7 DESCRIPTION OF TEST CONFIGURATION ...................................................................................................................... 7 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 7 EUT EXERCISE SOFTWARE .......................................................................................................................................... 7 DUTY CYCLE ................................................................................................................................................................ 7 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 8 EXTERNAL I/O CABLE .................................................................................................................................................. 8 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 8 SUMMARY OF TEST RESULTS ............................................................................................................................. 10 TEST EQUIPMENT LIST ......................................................................................................................................... 11 FCC§15.247 (I), §1.1307(B)(3)(I)(A)&§2.1093 - RF EXPOSURE .............................................................................. 13 APPLICABLE STANDARD ............................................................................................................................................ 13 RESULT ...................................................................................................................................................................... 13 RSS-102 § 6.3 -SAR EXEMPTION LIMITS ............................................................................................................ 14 APPLICABLE STANDARD ............................................................................................................................................ 14 TEST RESULT: ............................................................................................................................................................ 15 FCC §15.203 & RSS-GEN §6.8 - ANTENNA REQUIREMENT ............................................................................ 16 APPLICABLE STANDARD ............................................................................................................................................ 16 ANTENNA CONNECTOR CONSTRUCTION ......................................…
Text truncated - open the document above for the full version.
Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401X40820E-RF Page 1 of 3 EXHIBIT D - TEST SETUP PHOTOGRAPHS Conducted Emissions - Front View Conducted Emissions - Side View Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401X40820E-RF Page 2 of 3 Radiated Emissions View (9kHz-30MHz) Radiated Emissions View (30 MHz- 1 GHz) Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401X40820E-RF Page 3 of 3 Radiated Emissions View (1-18 GHz) Radiated Emissions View (18-25 GHz)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 5.00 µW |

WiFi & BLE module
Equipment Class
DTS - Digital Transmission System
Motorized Treadmill
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
WalkingPad Walking Device
Equipment Class
DTS - Digital Transmission System
Motorized Treadmill
Equipment Class
DTS - Digital Transmission System