FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. 3i Inc./
  3. 2AS3Q-PIVOX

2AS3Q-PIVOXPivo X

3i Inc.
Pivo X - FCC ID 2AS3Q-PIVOX - 3i Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 18, 2024
Application Purpose
Original Equipment
Date of Application
Mar 18, 2024
Equipment Note
Pivo X
Frequency Range
2402.00000000 - 2480.00000000
Company
3i Inc.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

3i Inc. U.S. Agent Designation for Service of Process (Applicant and U.S. Agent are Separate Parties) TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA ATTENTION: FCC Certification – Section 2.911(d)(7) Information Designated U.S. Agent Company Name: PIVO Inc. FRN: 0034834564 Contact Name: Ken Kim Address: 3003 North First Street #307 San Jose, CA 95134, United States Telephone No: (669) 500-8593 Email: [email protected] This letter is to confirm that we (PIVO Inc.) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. U.S. Agent Signature: Date: 2024-03-07 Signed by (Printed Name/Title): Ken Kim/CEO The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant Company name: 3i Inc. FRN: 0028407633 FCC ID: 2AS3Q-PIVOX Contact Name: Jiwuck Jung Address: Daegu Scale-up Hub Suite 903, Dongdaegu-ro 465, Dong-gu, Daegu, South Korea Telephone No: +82-70-47562133 Email: [email protected] Applicant Signature: Date: 2024-03-07 Signed by (Printed Name/Title): Jiwuck Jung / CTO

Attestation Statements

3i Inc. 2024.03.14 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for FCC ID: 2AS3Q-PIVOX [3i Inc.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Applicant signature) (Applicant printed name) Jiwuck Jung 3i Inc. 2024.03.14 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for FCC ID: 2AS3Q-PIVOX [3i Inc.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Jiwuck Jung

Cover Letter(s)

3i Inc. 2024.03.14 Eurofins Electrical and Electronic Testing NA, Inc. 914 W. Patapsco Avenue Baltimore, MD 21230 USA RE: CONFIDENTIALITY REQUEST FOR EUT NAME: Pivo X Trademark: N/A MODEL : PIVO-X-R1 FCC ID : 2AS3Q-PIVOX To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the - Block Diagram - Schematics - Operational Description required to be submitted with this application be permanently withheld from public review. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Please contact me if there is any information you may need. Sincerely, Client’s signature: Client’s name / title : Jiwuck Jung / CTO Contact information / address: Daegu Scale-up Hub Suite 903, Dongdaegu-ro 465, Dong- gu, Daegu, South Korea

Cover Letter(s)

3i Inc. 2024.03.14 Eurofins Electrical and Electronic Testing NA, Inc. 914 W. Patapsco Avenue Baltimore, MD 21230 USA RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Shenzhen BCTC Testing Co., Ltd to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Client’s signature: Client’s name / title : Jiwuck Jung / CTO Contact information / address: Daegu Scale-up Hub Suite 903, Dongdaegu-ro 465, Dong- gu, Daegu, South Korea

ID Label/Location Info

Size:30*15mm Pivo X FCC ID: 2AS3Q-PIVOX Label location

Internal Photos

Internal Photos Antenna

RF Exposure Info

RF EXPOSURE EVALUATION METHOD FCC ID: 2AS3Q-PIVOX Applicable standard: In accordance with FCC 47 CFR part 2 (2.1093) this device has been defined as a portable device which is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. Portable devices must be evaluated using the specified in FCC 47 CFR part 2 (2.1093) and ANSI/IEEEC95.1-1992. and had been tested in accordance with the measurement methods and procedures specified in IEEE 1528-2003. Per FCC KDB 447498 D01 v06, the 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances s 50 mm are determined by: SAR Test Exclusion Thresholds for 100 MHz – 6 GHz and ≤ 50 mm Approximate SAR Test Exclusion Power Thresholds at Selected Frequencies and Test Separation Distances are illustrated in the following Table. The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. Mode Frequency(MHz) Maximum Conducted Output Power(PK) (dBm) Conducted Output Power Limit(dBm) GFSK(1Mbps) 2402 1.04 30 2440 1.23 30 2480 1.08 30 GFSK(2Mbps) 2402 0.96 30 2440 1.23 30 2480 1.06 30 max possible output power (PK,conducted):1±1dBm -2.31dBi logarithmic terms convert to numeric result is nearly 0.59 2dBm=1.58mW 2402MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 01.58/5*√2.402=0.49≤3.0 2440MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 1.58/5*√2.44=0.494≤3.0 2480MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 1.58/5*√2.48=0.498≤3.0 Conclusion: 1. [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] * [√f(GHz)] < 3.0. 2. SAR Test Exclusion Thresholds is 3.0 for separation distance 5mm. Therefore, SAR test is not required.

Test Report

Page 1 of 18 Test Report Verified code: Report No.: E20230306359801-1 Customer: Guangdong Bestcore Internet of Things Technology CO., Ltd Address: Room1501,15F,ShuMao Building,6 Xiangxing Road, Torch Development District,Zhong shan Sample Name: Bluetooth Module Sample Model: BC204 Receive Sample Date: Mar.07,2023 Test Date: Mar.07,2023 ~ Mar.07,2023 Reference Document: ANSI IEEE 149-2021 Part 7, Part 8, Part 10 Test Result: Not make judgment Prepared by: Reviewed by: Approved by: GRG METROLOGY & TEST GROUP CO., LTD. Issued Date: GRG METROLOGY & TEST GROUP CO., LTD. Address: No.163,Pingyun Road, West of Huangpu Avenue, Guangzhou, Guangdong, China Tel:(+86)400-602-0999 FAX:(+86)020-38698685 Web:http://www.grgtest.com 348480 2023-03-09 Report No.: E20230306359801-1 Page 2 of 18 Statement 1. The report is invalid without "special seal for inspection and testing"; some copies are invalid; The report is invalid if it is altered or missing; The report is invalid without the signature of the person who prepared, reviewed and approved it. 2. The sample information is provided by the client and responsible for its authenticity; The content of the report is only valid for the samples sent this time. 3. When there are reports in both Chinese and English, the Chinese version will prevail when the language problems are inconsistent. 4. If there is any objection concerning the report, please inform us within 15 days from the date of receiving the report. 5. Without the agreement of the laboratory, the client is not authorized to use the test results for unapproved propaganda. ------------ The following blanks ------------ Report No.: E20230306359801-1 Page 3 of 18 TABLE OF CONTENTS 1. TEST RESULT SUMMARY ...................................................................................................................... 5 2. GENERAL DESCRIPTION OF EUT ......................................................................................................... 6 2.1 APPLICANT INFORMATION ...................................................................................................................... 6 2.2 MANUFACTURER ........................................................................................................................................ 6 2.3 FACTORY ...................................................................................................................................................... 6 2.4 BASIC DESCRIPTION OF EUT ................................................................................................................... 6 2.5 TEST SCENE .................................................................................................................................................. 6 2.6 SAMPLE WORK DESCRIPTION ................................................................................................................. 6 2.7 ASSISTIVE DEVICE INFORMATION......................................................................................................... 7 2.8 SAMPLE CONNECTION DIAGRAM .......................................................................................................... 7 3. LABORATORY .......................................................................................................................................... 8 4. MEASUREMENT UNCERTAINTY .......................................................................................................... 9 5. EQUIPMENT AND TOOLS USED DURING TEST .............................................................................. 10 6. ANTENNA RADIATION PERFORMANCE MEASUREMENT ........................................................... 11 6.1 LIMITS ......................................................................................................................................................... 11 6.2 TEST PROCEDURE ..................................................................................................................................... 11 6.3 CONFIGURATION OF SYSTEM UNDER TEST ...................................................................................... 12 6.4 TEST PHOTOS ............................................................................................................................................. 12 6.5 TEST RESULTS ........................................................................................................................................... 13 7. PHOTOGRAPH OF THE EUT ................................................................................................................. 17 ------------ The following blanks ------------ Report No.: E20230306359801-1 Page 4 of 18 REPORT ISSUED HISTORY Report Version Report No. Description Compile Date 1.0 E20230306359801-1 Original Issue 2023-03-07 ------------ The following blanks ------------ Report No.: E20230306359801-1 Page 5 of 18 1. TEST RESULT SUMMARY Test Item Test Frequency Test Method Test Scene Test Result Gain 2400 MHz ~2500MHz ANSI IEEE 149-2021 Part 8 scene 1 / 1) Radiation efficiency 2400 MHz ~2500MHz ANSI IEEE 149-2021 Part 10 scene 1 / 1) Radiation pattern 2400 MHz ~2500MHz ANSI IEEE 149-2021 Part 7 scene 1 / 1) Note 1):Customer-defined test, test results do not make judgment. ------------ The following blanks ------------ . Report No.: E20230306359801-1 Page 6 of 18 2. GENERAL DESCRIPTION OF EUT 2.1 APPLICANT INFORMATION Name: Guangdong Bestcore Internet of Things Technology CO., Ltd Address: Room1501,15F,ShuMao Building,6 Xiangxing Road, Torch Development District,Zhong shan 2.2 MANUFACTURER Name: Guangdong Bestcore Internet of Things Technology CO., Ltd Address: Room1501,15F,ShuMao Building,6 Xiangxing Road, Torch Development District,Zhong shan 2.3 FACTORY Name: Guangdong Bestcore Internet of Things Technology CO., Ltd Address: Room1501,15F,ShuMao Building,6 Xiangxing Road, Torch Development District,Zhong shan 2.4 BASIC DESCRIPTION OF EUT Product Name: Bluetooth Module Produc…

Text truncated - open the document above for the full version.

Test Report

No.:BCTC/RF-EMC-005 Page: 1 of 53 Edition:B.1 TEST REPORT Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC2311675657E Applicant: 3i Inc. Product Name: Pivo X Test Model: PIVO-X-R1 Tested Date: 2023-12-06 to 2024-01-15 Issued Date: 2024-01-15 Report No.: BCTC2311675657E No.:BCTC/RF-EMC-005 Page: 2 of 53 Edition:B.1 FCC ID:2AS3Q-PIVOX The test report is effective only with both signature and specialized stamp.This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen BCTC Testing Co., Ltd, this report can’t be reproduced except in full.The tested sample(s) and the sample information are provided by the client. Product Name: Pivo X Trademark: N/A Model/Type Reference: PIVO-X-R1 Prepared For: 3i Inc. Address: Daegu Scale-up Hub Suite 903, Dongdaegu-ro 465, Dong-gu, Daegu, South Korea Manufacturer: Shenzhen Vitalitim Technology Co.,Ltd. Address: RM1101, Chang'an Building, No.56, Second Industrial Zone, Houting Community, Shajing Street, Bao'an District, Shenzhen, China Prepared By: Shenzhen BCTC Testing Co., Ltd. Address: 1-2/F., Building B, Pengzhou Industrial Park, No.158, Fuyuan 1st Road, Zhancheng, Fuhai Subdistrict, Bao'an District, Shenzhen, Guangdong, China. Sample Received Date: 2023-12-06 Sample Tested Date: 2023-12-06 to 2024-01-15 Issue Date: 2024-01-15 Report No.: BCTC2311675657E Test Standards: FCC Part15.247 ANSI C63.10-2013 Test Results: PASS Remark: This is Bluetooth BLE radio test report. Tested by: Approved by: Lei Chen/Project Handler Zero Zhou/Reviewer Report No.: BCTC2311675657E No.:BCTC/RF-EMC-005 Page: 3 of 53 Edition:B.1 Table Of Content Test Report Declaration Page 1. Version .................................................................................................................. 5 2. Test Summary ....................................................................................................... 6 3. Measurement Uncertainty ..................................................................................... 7 4. Product Information And Test Setup ..................................................................... 8 4.1 Product Information ............................................................................................... 8 4.2 Test Setup Configuration ...................................................................................... 9 4.3 Support Equipment ............................................................................................... 9 4.4 Channel List ........................................................................................................ 10 4.5 Test Mode ........................................................................................................... 10 4.6 Table of parameters of text software setting ....................................................... 10 5. Test Facility And Test Instrument Used ............................................................... 11 5.1 Test Facility ......................................................................................................... 11 5.2 Test Instrument Used .......................................................................................... 11 6. Conducted Emissions .......................................................................................... 13 6.1 Block Diagram Of Test Setup .............................................................................. 13 6.2 Limit .................................................................................................................... 13 6.3 Test procedure .................................................................................................... 13 6.4 EUT Operating Conditions .................................................................................. 13 6.5 Test Result .......................................................................................................... 14 7. Radiated Emissions ............................................................................................. 16 7.1 Block Diagram Of Test Setup .............................................................................. 16 7.2 Limit .................................................................................................................... 17 7.3 Test procedure .................................................................................................... 18 7.4 EUT operating Conditions ................................................................................... 19 7.5 Test Result .......................................................................................................... 19 8. Radiated Band Emission Measurement And Restricted Bands Of Operation ..... 24 8.1 Block Diagram Of Test Setup .............................................................................. 24 8.2 Limit .................................................................................................................... 24 8.3 Test Procedure ................................................................................................... 25 8.4 EUT Operating Conditions .................................................................................. 26 8.5 Test Result .......................................................................................................... 26 9. Power Spectral Density Test ............................................................................... 27 9.1 Block Diagram Of Test Setup .............................................................................. 27 9.2 Limit .................................................................................................................... 27 9.3 Test procedure .................................................................................................... 27 9.4 EUT Operating Conditions .................................................................................. 27 9.5 Test Result .....................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No.: BCTC2311675657E No.:BCTC/RF-EMC-005 Page: 51 of 53 Edition:B.1 15. EUT Test Setup Photographs Conducted emissions Radiated Measurement Photos Report No.: BCTC2311675657E No.:BCTC/RF-EMC-005 Page: 52 of 53 Edition:B.1

Contact Information

Applicant

Jiwuck Jung(CTO)
[email protected]+82-70-47562133Fax: +82-2-6442-8593

Technical Contact

Shenzhen BCTC Testing Co., Ltd.Alan Mei
[email protected]+8675536882589

1-2/F., Building B, Pengzhou Industrial Park, · Bao'an District, Shenzhen, Guangdong · China

Test Firm

Shenzhen BCTC Testing Co., Ltd.Sally He
[email protected]15999690624

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.33 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted. This device has 1 MHz and 2 MHz bandwidth modes. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures.

Other Applications from 3i Inc.

2AS3Q-PV-PMVB

Pivo Max

Aug 04, 2026

Equipment Class

DTS - Digital Transmission System
PIVO Remote Control - FCC ID 2AS3Q-PVI1R02 - 3i Inc.
2AS3Q-PVI1R02

PIVO Remote Control

Aug 24, 2021

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Pivo Pod - FCC ID 2AS3Q-PIVOR1 - 3i Inc.
2AS3Q-PIVOR1

Pivo Pod

Jul 08, 2021

Equipment Class

DTS - Digital Transmission System
Pivo Remote Control - FCC ID 2AS3QPIVO-RC-1 - 3i Inc.
2AS3QPIVO-RC-1

Pivo Remote Control

Jan 12, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter