Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
08/15/2022, 15.21 Carrier – NaturaLINE, PrimeLINE, ThinLINE, EliteLINE 08/15/2022, 15.21 ! 1.Electrical Ratings and Requirements Product Supply Ratings Power Supply: 12-30 VAC 50-60 Hz or 6-15 VDC, 3A WARNING These procedures should only be performed by trained installation technicians. High voltage/current lines are present and caution should be used to prevent injuries. Installer must conform to local standards and ordinances as required. IMPORTANT Make sure that power is off, unit is disconnected and that no damages have occurred during drilling. 08/15/2022, 15.21 2.Required Tool Kit 13mm (1/2 “) Drill Bit Center Punch Cutting compound for the drill Drill for removing burrs Degreasing rags 18mm open face wrench Side cutting pliers Magnet Cable Ties 08/15/2022, 15.21 3.GT Sense Reefer Kit A complete GT Sense Reefer Kit includes: 1.GT Sense Device 2.Antenna (80 mm diameter round black version with 3M VHB tape and threaded mount on the back cables and connectors 3.RMM Cable . 08/15/2022, 15.21 4.RMM Bracket 08/15/2022, 15.21 5.Installation Before beginning the antenna installation, please print and cut out the template to use for locating the antenna mounting hole. Step 1 Use the antenna installation template to locate the antenna placement on the access cover. Place the template towards the edge of the access cover and mark the center point. Check that there is nothing on the inside surface of the access cover that could be damaged when a hole is drilled in the centre-punched location. NOTE: Avoid blocking the information labels. NOTE: If an antenna by another company is already mounted, DO NOT remove it. 08/15/2022, 15.21 Step 2 Drill a 13 mm (1/2′′) hole at the centre-punched mark. Remove all burrs after drilling. Step 3 Degrease/clean the surface where the antenna will be mounted with a metal cleaner or similar before fitting the antenna. 08/15/2022, 15.21 Step 4 Remove the nut, lock washer, and plastic washer from the threaded mount on the backside of the antenna by slipping them off the antenna cable via the slots. Step 5 Insert the connector end of the antenna cable through the drilled hole in the access cover. Remove the 3M VHB table liner from the backside of the antenna. Push the thread mount through the drilled hole and secure the antenna cables. Note: Specific orientation/rotation of the antenna is not required. Step 6 Replace the plastic washer, lock washer and nut on the antenna threaded mount on the inside of the access cover. Tighten the nut firmly with the 18mm open face wrench, torque to 1.5 N-m (11.5 in-lbs). 08/15/2022, 15.21 Step 7 Remove the access plug from side of control box. Cut a hole in the plug and run cables trough. Seal with silicone. Step 8 If a modem is already present in the RMM slot, remove it maintaining the Mounting screws and unplug all the connections 08/15/2022, 15.21 Step 9 Route the antenna cables across the door hinge through existing cable channel (if present) to the RMM slot using the cable ties to secure the cables. Do not be concerned with the extra length of cable at this time. Step 10 Fit the GT Sense Device into the RMM slot and secure with the screws from the removed modem. If no modem was removed, use the M5 screws and mylar washers provide in the RMM bracket kit. InsertGT Senseand slide down and lock in place 08/15/2022, 15.21 Step 11 Connect and secure the antenna cables to appropriate Farkas connectors on the GT Sense Device before connecting the RMM cable to the The antenna cables are identified by labels near the connector ends. The corresponding Fakra connectors on the GT Sense Device are identified with the names “GPS” and “CELL”. After connecting the antenna cables, attach the RMM cable to the mating connector on the GT Sense Device and secure with the screws provided on the connector. Step 12 Plug the 3 and 7 position connector into the orange 10 position connector on the end of the GT RMM Cable as indicated by the 3/7 label on the 10 position connector. 08/15/2022, 15.21 If the RMM Cable you are installing has an inline fuse, the fuse is intended to be 08/15/2022, 15.21 on the Ground Line for A/C reverse polarity protection for the GT Sense Device. Orange Connector on CBL0037 GT RMM Cable The 3 and 7 position connector plugged into the orange 10 position connector. Step 13 Secure any extra length of antenna cable or RMM cable with cable ties making sure not cables are in tension. Step 14 Secure the control box door. Step 15 Use the Installation app to verify GPS and communications are working (future). Installation complete. /CE/ISED Compliance FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to w…
Text truncated - open the document above for the full version.
Globetracker,ApS Strandgade914thFloorDK-1401CopenhagenK38102885Denmark 2.911(d)(5)(i)EquipmentTypeAttestationv1.2 Section2.911(d)(5)(i)Certification–EquipmentType Companyname:Globetracker,ApS Address:Strandgade914thFloorDK-1401CopenhagenK38102885Denmark ProductName:AssetTrackingDevice/DataModem FCCID:2ASJR-CM275-1113130 Model(s):CM2.75-1113130 2.911(d)(5)(i)EquipmentType We,[Insertapplicantname](“theapplicant”)certifythattheequipmentforwhichauthorizationis soughtthroughcertificationisnot: Prohibitedfromreceivinganequipmentauthorizationpursuantto§2.903;oftheFCCrules. Identifiedasanequipmenttypeinthe“CoveredList” NOTE1 Yourssincerely, Name:MarkOudshoornDate:2025-12-09 TitleandCompanyname:Engineer/Globetracker,ApS NOTE1 “CoveredList”;istheListofEquipmentandServicesCoveredBySection2ofTheSecureNetworksAct,availableat https://www.fcc.gov/supplychain/coveredlist References; 1)986446D01CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2)FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
Globetracker,ApS Strandgade914thFloorDK-1401CopenhagenK38102885Denmark 2.911(d)(5)(ii)ApplicantAttestationv1.3 Section2.911(d)(5)(ii)Certification–Applicant(CoveredList) Companyname:Globetracker,ApS Address:Strandgade914thFloorDK-1401CopenhagenK38102885Denmark ProductName:AssetTrackingDevice/DataModem FCCID:2ASJR-CM275-1113130 Model(s):CM2.75-1113130 2.911(d)(5)(ii)Applicantfiling We,[Insertapplicantname](“theapplicant”)certifythat,asofthedateofthefilingoftheapplication, theapplicantisidentified/isnotidentified NOTE1 onthe“CoveredList” NOTE2 ,establishedpursuant to§1.50002ofthischapter,asanentityproducingcoveredcommunicationsequipment. Yourssincerely, Name:MarkOudshoornDate:2025-12-09 TitleandCompanyname:Engineer/Globetracker,ApS NOTE1 Deleteoptionnotapplicabletothisapplication. NOTE2 “CoveredList”;istheListofEquipmentandServicesCoveredBySection2ofTheSecureNetworksAct,availableat https://www.fcc.gov/supplychain/coveredlist References; 1)986446D01CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2)FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
Globetracker, ApS Strandgade 91 4th Floor Copenhagen K DK-1401 Denmark Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2025/12/09 U.S. Agent Designation Globetracker, ApS acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2ASJR-CM275-1113130): Name and company of U.S. agent: GLOCERTS TECHNOLOGY INC Physical U.S. address of agent: 19784 SUNKISSED RIDGE DR RIVERSIDE, CA 92507 United States FRN of U.S. agent: 0036339737 Email address of U.S. agent: [email protected] GLOCERTS TECHNOLOGY INC acknowledges their obligation to accept service of process on behalf of Globetracker, ApS Globetracker, ApS with the FRN [0028252575] accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Sincerely, Signature Mark Oudshoorn Engineer Globetracker, ApS Signature Huiying Fan Director GLOCERTS TECHNOLOGY INC 48_[mo del] US_Agent_2.911(d)(7) - U, V0 5
Globetracker,ApS Strandgade914thFloorDK-1401CopenhagenK38102885Denmark OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2025-12-09 Subject;RequestforConfidentiality FCCID:2ASJR-CM275-1113130 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Globetracker,ApS Strandgade914thFloorDK-1401CopenhagenK38102885Denmark Name:MarkOudshoorn Title:Engineer
Globetracker,ApS Strandgade914thFloorDK-1401CopenhagenK38102885Denmark LetterofAuthorization Company:Globetracker,ApS Address:Strandgade914thFloorDK-1401CopenhagenK38102885Denmark ProductName:AssetTrackingDevice/DataModem ModelNumber(s):CM2.75-1113130 ProductDescription:AssetTrackingDevice/DataModem WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningthecertificationofabovenamed equipment. WedeclarethatMiCOMLabsInc.isallowedtoforwardallinformationrelatedtothe approvalandcertificationofequipmenttotheregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsofourown. Signature:Date:2025-12-09 Name:MarkOudshoorn Title:Engineer Company:Globetracker,ApS
FCC ID: 2ASJR-CM275-1113130 External Photos of the EUT FCC ID: 2ASJR-CM275-1113130 FCC ID: 2ASJR-CM275-1113130
70.00 2.76 42.00 1.65 R6.50 0.26 R2.00 0.08 NOTES: 1. TEXT AND IMAGES SHOWN ARE FOR REFERENCE ONLY LABEL WILL BE PRINTED FROM PRINTER FILE ON MANUFACTURING LINE 2. LABEL BACKGROUND TO BE PANTONE PMS 278 C, LIGHT BLUE, WATER-PROOF POLYESTER,WITH PERMANENT ADHESIVE 3. THE FOLLOWING LABEL INFORMATION IS PRINTED AFTER A SUCCESSFUL PCB TEST: - SERIAL NUMBER - BUILD DATE - CCID - CELL ID - DEV EUI 4. THE QR CODE CONTAINS THE SERIAL NUMBER, MODEL, AND BUILD DATE. 5. BUILD DATE SHALL FOLLOW THE FOLLOWING FORMAT: - YY = 2 DIGIT NUMERIC YEAR. - WW = 2 DIGIT NUMERIC WEEK - S = 1 DIGIT NUMERIC PCB ASSEMBLY HOUSE IDENTIFIER, USE 0 IF THE PCB IS ASSEMBLED BY THE PRODUCT MANUFACTURER. OTHERWISE, IT IS TO BE ASSIGNED BY THE PRODUCT MANUFACTURER. - PPPPPPPPP(P) = 9 or 10 DIGIT PCBA MANUFACTURER'S SERIAL NUMBER MANUFACTURER & MANUFACTURER ADDRESS BUILD DATE 5 PRODUCT MODEL NUMBER SERIAL NUMBER 4 COUNTRY OF ORIGIN 2 REVISIONS REV.DESCRIPTIONDATEAPPROVED C REMOVED JAPAN CERTIFICATION MARK 16NOV2023JJT/MO D CHANGED DATE CODE FORMAT & ADDED NOTE 5 14DEC2023MO/JJT E ADDEDCOUNTRY OF ORIGIN. UPDATED FCC AND IC NUMBERS 10/22/2025GPD 70.00 2.76 42.00 1.65 R6.50 0.26 R2.00 0.08 D C B A A B C D 1 2 3 4 5 6 7 8 7 6 5 4 3 2 COPYRIGHT © 2022 GLOBE TRACKER ALL RIGHTS RESERVED 0: 1.0 mm 0.0 0.5 mm 0.00: 0.25 mm 0.000: 0.125 mm ANGULAR: 0.5 DEG UNITS OF MEASURE: FINISH: TITLE B 06SEP2022 SEE NOTES LAB-0014 SHEET 1 OF 1 TOLERANCES EXCEPT WHERE NOTED MATERIAL: REVPART NO. SIZE CONFIDENTIAL DRAWN: QA: APPROVED: MFG: CHECKED: GLOBE TRACKER, ApS CVR#33579004 DK-1401 Copenhagen K, DENMARK CONFIDENTIAL JJT GEN 2.75 CM2.75-1113120 INFORMATION & SN LABEL METRIC, mm SEE NOTES JB ES MA MO SCALE 1:1 E Contains Contains Label and Location
FCC ID: 2ASJR-CM275-1113130 Internal Photos of the EUT Lora Antenna FCC ID: 2ASJR-CM275-1113130 FCC ID: 2ASJR-CM275-1113130 BLE Antenna FCC ID: 2ASJR-CM275-1113130 FCC ID: 2ASJR-CM275-1113130
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn RF Exposure MPE Report Reference No. ..................... : FCC ID............................................. : CTA25081903403 2ASJR-CM275-1113130 Compiled by ( position+printed name+signature) . : File administrators Zoey Cao Supervised by ( position+printed name+signature) . : Project Engineer Ace Chai Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Sep. 13, 2025 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao‘an District, Shenzhen, China Applicant’s name ............................ : Globetracker, ApS Address............................................ : Strandgade 91 4th Floor Copenhagen K DK-1401 Denmark Standard ........................................... : 47CFR §1.1310 47CFR §2.1091 KDB447498 D01 General RF Exposure Guidance v06 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purpses as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : Asset Tracking Device / Data Modem Trade Mark ....................................... : Manufacturer .................................... : Globetracker, ApS Model/Type reference ...................... : CM2.75-1113130 Listed Models ................................... : N/A Rating ............................................... : Input: 12-36Vac, 50/60Hz 3A or 9-18Vdc, 3A Battery: 3.7V, 6600mAh, 24.42Wh Result ............................................... : PASS Report No.: CTA25081903403 Page 2 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : Asset Tracking Device / Data Modem Model /Type : CM2.75-1113130 Listed Models : N/A Applicant : Globetracker, ApS Address : Strandgade 91 4th Floor Copenhagen K DK-1401 Denmark Manufacturer : Globetracker, ApS Address : Strandgade 91 4th Floor Copenhagen K DK-1401 Denmark Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA25081903403 Page 3 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ............................................................................................................ 4 2 SUMMARY .......................................................................................................................... 5 2.1 General Remarks ..................................................................................................... 5 2.2 Product Description ................................................................................................. 5 2.3 Special Accessories ................................................................................................. 5 2.4 Modifications ............................................................................................................ 5 3 TEST ENVIRONMENT ....................................................................................................... 6 3.1 Address of the test laboratory .................................................................................. 6 3.2 Test Facility .............................................................................................................. 6 3.3 Statement of the measurement uncertainty ............................................................. 6 4 Test limit .............................................................................................................................. 7 4.1 Requirement ............................................................................................................ 7 4.2 MPE Calculation Method ......................................................................................... 7 4.3 Conducted Power Results ....................................................................................... 7 4.4 Manufacturing tolerance .......................................................................................... 8 4.5 Standalone MPE Result ........................................................................................... 8 5 Conclusion ........................................................................................................................... 8 Report No.: CTA25081903403 Page 4 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 1 T E S T S T A N D A R D S The tests were performed according to following standards: ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to R…
Text truncated - open the document above for the full version.
1. Antenna Description: Antenna type Ceramic antenna Model CM2.75-1113130-BLE Frequency range 2400-2500MHz Manufacturer Globetracker, ApS Address Strandgade 91 4th Floor Copenhagen K DK-1401 Denmark ANT Peak Gain 0.80 dBi 2. Antenna Photo: 3. Test Equipment & Conditions 3.1 Test instrument VSWR is tested using Agilent E5071B connected to a hand mechanism, and the status is free space. 3.2 Test environment and methods 4.Antenna Radiation Pattern 2400MHz 2450MHz 2500MHz
1. Antenna Description: Antenna type Internal Antenna Model CM2.75-1113130-LORA Frequency range 902MHz-928MHz Manufacturer Globetracker, ApS Address Strandgade 91 4th Floor Copenhagen K DK-1401 Denmark ANT Peak Gain 3.00 dBi 2. Antenna Photo:
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao‘an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. ...................: FCC ID. ......................................... : CTA25081903401 2ASJR-CM275-1113130 Compiled by ( position+printed name+signature) : File administrators Zoey Cao Supervised by ( position+printed name+signature) : Project Engineer Ace Chai Approved by ( position+printed name+signature) : RF Manager Eric Wang Date of issue ...................................: Sep. 13, 2025 Testing Laboratory Name .............: Shenzhen CTA Testing Technology Co., Ltd. Address ..........................................: Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao‘an District, Shenzhen, China Applicant’s name...........................: Globetracker, ApS Address ...........................................: Strandgade 91 4th Floor Copenhagen K DK-1401 Denmark Test specification ......................... : Standard ..........................................: FCC Part 15.247 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Equipment description ................ : Asset Tracking Device / Data Modem Trade Mark ......................................: Manufacturer ...................................: Globetracker, ApS Model/Type reference .....................: CM2.75-1113130 Listed Models ..................................: N/A Modulation ......................................: GFSK Frequency ........................................ From 2402MHz to 2480MHz Ratings ............................................: Input: 12-36Vac, 50/60Hz 3A or 9-18Vdc, 3A Battery: 3.7V, 6600mAh, 24.42Wh Result ..............................................: PASS Report No.: CTA25081903401 Page 2 of 25 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : Asset Tracking Device / Data Modem Model /Type : CM2.75-1113130 Listed Models : N/A Applicant : Globetracker, ApS Address : Strandgade 91 4th Floor Copenhagen K DK-1401 Denmark Manufacturer : Globetracker, ApS Address : Strandgade 91 4th Floor Copenhagen K DK-1401 Denmark Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA25081903401 Page 3 of 25 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ...................................................................................................................................... 4 2 SUMMARY .................................................................................................................................................... 5 2.1 General Remarks .............................................................................................................................. 5 2.2 Product Description* .......................................................................................................................... 5 2.3 Equipment Under Test ....................................................................................................................... 5 2.4 Short description of the Equipment under Test (EUT) ...................................................................... 5 2.5 EUT configuration .............................................................................................................................. 5 2.6 EUT operation mode ......................................................................................................................... 5 2.7 Block Diagram of Test Setup ............................................................................................................. 6 2.8 Related Submittal(s) / Grant (s) ......................................................................................................... 6 2.9 Modifications ...................................................................................................................................... 6 3 TEST ENVIRONMENT ................................................................................................................................. 7 3.1 Address of the test laboratory............................................................................................................ 7 3.2 Test Facility ....................................................................................................................................... 7 3.3 Environmental conditions .................................................................................................................. 7 3.4 Summary of measurement results .................................................................................................... 8 3.5 Statement of the measurement uncertainty .............................................…
Text truncated - open the document above for the full version.
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao‘an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. ..................... : FCC ID. ............................................ : CTA25081903402 2ASJR-CM275-1113130 Compiled by ( position+printed name+signature) .. : File administrators Zoey Cao Supervised by ( position+printed name+signature) .. : Project Engineer Ace Chai Approved by ( position+printed name+signature) .. : RF Manager Eric Wang Date of issue ..................................... : Sep. 13, 2025 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address ............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao‘an District, Shenzhen, China Applicant’s name ............................ : Globetracker, ApS Address ............................................ : Strandgade 91 4th Floor Copenhagen K DK-1401 Denmark Test specification ...........................: Standard ........................................... : FCC Part 15.247 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description .....................: Asset Tracking Device / Data Modem Trade Mark ....................................... : Manufacturer .................................... : Globetracker, ApS Model/Type reference....................... : CM2.75-1113130 Listed Models .................................. : N/A Modulation ....................................... : GFSK Frequency .......................................... 907MHz-923MHz Ratings ............................................. : Input: 12-36Vac, 50/60Hz 3A or 9-18Vdc, 3A Battery: 3.7V, 6600mAh, 24.42Wh Result................................................ : PASS Repo…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 907 MHz - 923 MHz | 4.60 mW |
| 2 | 15C | 2.40 GHz - 2.48 GHz | 500.00 µW |

ML3 Asset Tracker
Equipment Class
DTS - Digital Transmission SystemWireless Tracking Cargo System
Equipment Class
DTS - Digital Transmission System
GEN 2.75 Asset Tracker
Equipment Class
DTS - Digital Transmission System