2AUIUWYZEPWyze PARBBulb

Wyze Labs, Inc.
Wyze PARBBulb - FCC ID 2AUIUWYZEP - Wyze Labs, Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 21, 2021
Application Purpose
Original Equipment
Date of Application
Apr 21, 2021
Equipment Note
Wyze PARBBulb
Frequency Range
2402.00000000 - 2480.00000000
Company
Wyze Labs, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

说明书-灯泡和开关 BULB QUICK START GUIDE HOW TO USE SETUP THE BULB PAIRING / SETUP BY Remote 1.Power up the Bulb. 2.Install an AAA battery in the Remote, and pop out ② with yellow light on to start setting.(Note:The setup should be started in 15 mins after the bulb powered up) 3.PRESS ① to pair when the Bulb flashed. Multi bulbs:TURN ① to select Bulb with Bulb flashed, Press the knob to confirm the select. 4.Finally push-in the ② to daily use. 5.Press ① for light on or off, turn ① for brighten or darken. 6.Repeat step 2-4 for pairing with another remote.(Note:Do not setup with different remotes at the same time) MORE FEATURES / SETUP BY APP 1.Download the Wyze app and create an account. 2.Select the plus sign, and follow the instructions. FACTORY RESET Factory reset Remote by pressing and holding the ③ inside the battery cover for at least 3 seconds until the status LED stops flashing. Factory reset Bulb by power the Bulb up and down(Note:With lights go out completely) 5 times and then the Bulb will flash for several times after factory reseted. WARNING AND CAUTION  This device is not intended for use with emergency exits or not for emergency lighting.  Only use the control provided with or specified by these instructions to control this lamp. This lamp will not operate properly when connected to a standard (incandescent) dimmer or dimming control.  Not suitable for use with dimmers unless specifically designed for this product.  Not for use in totally enclosed or recessed luminaires.  Do not clean the device when it is connected to the power.  For safety reason,do not open the device,which will also void the warranty.  The device is not designed to be used by children 12 years of age or younger.  Manage in accordance with disposal laws in your area.  Choking Hazard: This remote contains small parts. Close supervision is recommended when this lamp is used by or near children or by others  who may not understand the need for these precautions.  Suitable for Damp Locations.  Not compatible with photosensor, timers or motion sensor. FCC Warning  This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note:This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. The device complies with FCC radiation exposure limits set forth for an uncontrolled environment. The device should be installed and operated with minimum distance of 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This Class B digital device complies with Canadian ICES-005. ISED Statement ‐ English: This device complies with Industry Canada license‐exempt RSS standard(s).Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device.The digital apparatus complies with Canadian CAN ICES‐3 (B)/NMB‐3(B). ‐ French:Le présentappareilestconforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitationestautorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareildoit accepter tout brouillageradioélectriquesubi, mêmesi le brouillageest susceptible d'encompromettre le fonctionnement. Radiation Exposure Statement This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Déclarationd'exposition aux radiations Cetéquipementestconforme Canada limitesd'exposition aux radiations dans un environnement non contrôlé. Cetéquipementdoitêtreinstallé et utilisé à distance minimum de 20cm entre le radiateur et votre corps. Bulb FCC ID:2AUIUWYZEP Bulb IC :25466-WYZEP Remote FCC ID:2AUIUWYZER1 Remote IC :25466-WYZER1 Troubleshooting Problem Solution Light won’t come on There is power to bulb Remote won’t work There is power to the battery and installed correctly. Reset the remote and the bulb(See FACTORY RESET ),then re-pair the bulb with the remote(see HOW TO USE) Limited Warranty This product is covered by a 3 year Limited Warranty.The complete Limited Warranty,warnings and cautions are include inside this packaging,and are also available at www.wyze.com. IN THE BOX  Wyze Bulb ×1  Wyze Remote ×1  AAA/LR03 ×1  Manual ×1 SPECIFICATION BULB Model: WYZEPB4025, WYZEPB40 Size: 94.5mm×94.5mm×118mm Rated power: 9.0 watts Lumens: 800 lumens Base type: E26 Working voltage: 120VAC 60Hz Color temper…

Text truncated - open the document above for the full version.

Attestation Statements

WyzeLabs,Inc. 5808LakeWashingtonBlvdNESte300KirklandWA98033USA ProductSimilarityDeclaration Date:January22,2021 FCCID:2AUIUWYZEP ModelNumber:42Modelnames No. ModelnameNo.Modelname 1WYZEBRB4022WYZEPB3040 2WYZEBRB2723WYZEPB3050 3WYZEBRB3024WYZEPB3060 4WYZEBRB3525WYZEPB3520 5WYZEBRB5026WYZEPB3525 6WYZEBRB6527WYZEPB3530 7WYZEPB402028WYZEPB3540 8WYZEPB402529WYZEPB3550 9WYZEPB403030WYZEPB3560 10WYZEPB404031WYZEPB5020 11WYZEPB405032WYZEPB5025 12WYZEPB406033WYZEPB5030 13WYZEPB272034WYZEPB5040 14WYZEPB272535WYZEPB5050 15WYZEPB273036WYZEPB5060 16WYZEPB274037WYZEPB6520 17WYZEPB275038WYZEPB6525 18WYZEPB276039WYZEPB6530 19WYZEPB302040WYZEPB6540 20WYZEPB302541WYZEPB6550 21WYZEPB303042WYZEPB6560 To: FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD ToWhomItMayConcern, WyzeLabs,Inc. 5808LakeWashingtonBlvdNESte300KirklandWA98033USA We,WyzeLabs,Inc.,declarethatthese42EUT(WyzePARBBulb)ModelNumbers listedbelowarethesameontheboard,Schematic,Hardwareversion,Software version,structureandinternalphotosaresame,nameddifferentlyduetomarketing purposes,differentCorrelatedColorTemperatureofLEDinthesamemodelseries, differentlens. No. ProductnameModelname 1 WyzePARBBulb WYZEBRB40CCT=4000K,BRlens 2 WyzePARBBulb WYZEBRB27CCT=2700K,BRlens 3 WyzePARBBulb WYZEBRB30CCT=3000K,BRlens 4 WyzePARBBulb WYZEBRB35CCT=3500K,BRlens 5 WyzePARBBulb WYZEBRB50CCT=5000K,BRlens 6 WyzePARBBulb WYZEBRB65CCT=6500K,BRlens 7 WyzePARBBulb WYZEPB4020CCT=4000K,PARlens,beamangle=20° 8 WyzePARBBulb WYZEPB4025CCT=4000K,PARlens,beamangle=25° 9 WyzePARBBulb WYZEPB4030CCT=4000K,PARlens,beamangle=30° 10 WyzePARBBulb WYZEPB4040CCT=4000K,PARlens,beamangle=40° 11 WyzePARBBulb WYZEPB4050 CCT=4000K,PARlens,beamangle=50° 12 WyzePARBBulb WYZEPB4060 CCT=4000K,PARlens,beamangle=60° 13 WyzePARBBulb WYZEPB2720CCT=2700K,PARlens,beamangle=20° 14 WyzePARBBulb WYZEPB2725CCT=2700K,PARlens,beamangle=25° 15 WyzePARBBulb WYZEPB2730CCT=2700K,PARlens,beamangle=30° 16 WyzePARBBulb WYZEPB2740CCT=2700K,PARlens,beamangle=40° 17 WyzePARBBulb WYZEPB2750 CCT=2700K,PARlens,beamangle=50° 18 WyzePARBBulb WYZEPB2760 CCT=2700K,PARlens,beamangle=60° 19 WyzePARBBulb WYZEPB3020CCT=3000K,PARlens,beamangle=20° 20 WyzePARBBulb WYZEPB3025CCT=3000K,PARlens,beamangle=25° 21 WyzePARBBulb WYZEPB3030CCT=3000K,PARlens,beamangle=30° 22 WyzePARBBulb WYZEPB3040CCT=3000K,PARlens,beamangle=40° 23 WyzePARBBulb WYZEPB3050 CCT=3000K,PARlens,beamangle=50° 24 WyzePARBBulb WYZEPB3060 CCT=3000K,PARlens,beamangle=60° 25 WyzePARBBulb WYZEPB3520CCT=3500K,PARlens,beamangle=20° 26 WyzePARBBulb WYZEPB3525CCT=3500K,PARlens,beamangle=25° 27 WyzePARBBulb WYZEPB3530CCT=3500K,PARlens,beamangle=30° 28 WyzePARBBulb WYZEPB3540CCT=3500K,PARlens,beamangle=40° 29 WyzePARBBulb WYZEPB3550 CCT=3500K,PARlens,beamangle=50° 30 WyzePARBBulb WYZEPB3560 CCT=3500K,PARlens,beamangle=60° 31 WyzePARBBulb WYZEPB5020CCT=5000K,PARlens,beamangle=20° 32 WyzePARBBulb WYZEPB5025CCT=5000K,PARlens,beamangle=25° WyzeLabs,Inc. 5808LakeWashingtonBlvdNESte300KirklandWA98033USA 33 WyzePARBBulb WYZEPB5030CCT=5000K,PARlens,beamangle=30° 34 WyzePARBBulb WYZEPB5040 CCT=5000K,PARlens,beamangle=40° 35 WyzePARBBulb WYZEPB5050 CCT=5000K,PARlens,beamangle=50° 36 WyzePARBBulb WYZEPB5060CCT=5000K,PARlens,beamangle=60° 37 WyzePARBBulb WYZEPB6520CCT=6500K,PARlens,beamangle=20° 38 WyzePARBBulb WYZEPB6525CCT=6500K,PARlens,beamangle=25° 39 WyzePARBBulb WYZEPB6530CCT=6500K,PARlens,beamangle=30° 40 WyzePARBBulb WYZEPB6540 CCT=6500K,PARlens,beamangle=40° 41 WyzePARBBulb WYZEPB6550 CCT=6500K,PARlens,beamangle=50° 42 WyzePARBBulb WYZEPB6560CCT=6500K,PARlens,beamangle=60° Shouldyouhaveanyquestionsorcommentsregardingthismatter,pleasehavemy bestattention. Sincerely, (Signed) Name/Title:DongshengSong/ChiefProductOfficer Company:WyzeLabs,Inc. Address:5808LakeWashingtonBlvdNESte300KirklandWA98033USA Phone:5176141124 Fax:/ Email:[email protected]

Cover Letter(s)

WyzeLabs,Inc.C5266091_X8_Ed.1 1/1 LetterofAuthorization Company:WyzeLabs,Inc. Address:5808LakeWashingtonBlvdNESte300KirklandWA 98033USA ProductName:WyzePARBBulb ModelNumber: No.ModelnameNo.Modelname 1WYZEBRB4022WYZEPB3040 2WYZEBRB2723WYZEPB3050 3WYZEBRB3024WYZEPB3060 4WYZEBRB3525WYZEPB3520 5WYZEBRB5026WYZEPB3525 6WYZEBRB6527WYZEPB3530 7WYZEPB402028WYZEPB3540 8WYZEPB402529WYZEPB3550 9WYZEPB403030WYZEPB3560 10WYZEPB404031WYZEPB5020 11WYZEPB405032WYZEPB5025 12WYZEPB406033WYZEPB5030 13WYZEPB272034WYZEPB5040 14WYZEPB272535WYZEPB5050 15WYZEPB273036WYZEPB5060 16WYZEPB274037WYZEPB6520 17WYZEPB275038WYZEPB6525 18WYZEPB276039WYZEPB6530 19WYZEPB302040WYZEPB6540 20WYZEPB302541WYZEPB6550 21WYZEPB303042WYZEPB6560 FCCIdentifier:2AUIUWYZEP WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WyzeLabs,Inc.C5266091_X8_Ed.1 1/1 WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:DongshengSongDate:2021.1.21 Title:ChiefProductOfficer Signatureofapplicant:

External Photos

APPENDIX A. PHOTOGRAPHS OF EUT General view General view General view

ID Label/Location Info

Label location

Internal Photos

APPENDIX A. PHOTOGRAPHS OF EUT Internal view Internal view Internal view RF Module RF Module Antenna RF module

RF Exposure Info

Fangguang Inspection & Testing Co., Ltd. Phone: +86-510-68790033 Web: www.fgtest.cn Page Number: 1 of 5 RF Exposure Evaluation Declaration Report No.: S20201228825405 Report Version: V01 Issue Date: 03-25-2021 Applicant: Wyze Labs,Inc. Address: 5808 Lake Washington Blvd NE Ste 300 Kirkland WA 98033 FCC ID: 2AUIUWYZEP Application Type: Certification Product: Wyze PARB Bulb Model No.: WYZEPB4025 FCC Classification: Digital Transmission System (DTS) FCC Rule Part(s): Part 15 Subpart C (15.247) Test Procedure(s): ANSI C63.10-2013, KDB 558074 D01v05r02 Test Date: January 05~January 12, 2021 The test results relate only to the samples tested. The test results shown in the test report are traceable to the national/international standards through the calibration of the equipment and evaluated measurement uncertainty herein. The test report shall not be reproduced except in full without the written approval of Fangguang Inspection & Testing Co., Ltd. Reviewed By (Amos Xia) Senior Test Engineer Approved By (Kerry Zhou) Engineer Manager Report No.: S20201228825405 Page Number: 2 of 5 Revision History Report No. Version Description Issue Date S20201228825405 Rev. 01 / 03-26-2021 Report No.: S20201228825405 Page Number: 3 of 5 1. PRODUCT INFORMATION 1.1. Equipment Description Product Name: Wyze PARB Bulb Model Name: WYZEPB4025 Additional Model: WYZEBRB40\WYZEBRB27\WYZEBRB30\WYZEBRB35\WYZEBRB50\WYZ EBRB65\WYZEPB4020\WYZEPB4030\WYZEPB4040\WYZEPB4050\WYZE PB4060\WYZEPB2720\WYZEPB2725\WYZEPB2730\WYZEPB2740\WYZE PB2750\WYZEPB2760\WYZEPB3020\WYZEPB3025\WYZEPB3030\WYZE PB3040\WYZEPB3050\WYZEPB3060\WYZEPB3520\WYZEPB3525\WYZE PB3530\WYZEPB3540\WYZEPB3550\WYZEPB3560\WYZEPB5020\WYZE PB5025\WYZEPB5030\WYZEPB5040\WYZEPB5050\WYZEPB5060\WYZE PB6520\WYZEPB6525\WYZEPB6530\WYZEPB6540\WYZEPB6550\WYZE PB6560 Input Voltage Range: AC 120V/60Hz,9W Bluetooth Version: 5.0(1Mbps) Antenna Type: PCB Antenna Antenna Gain: 1.5dBi Report No.: S20201228825405 Page Number: 4 of 5 2. RF Exposure Evaluation 2.1. Limits According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Average Time (Minutes) (A) Limits for Occupational/ Control Exposures 300-1500 -- -- f/300 6 1500-100,000 -- -- 5 6 (B) Limits for General Population/ Uncontrolled Exposures 300-1500 -- -- f/1500 6 1500-100,000 -- -- 1 30 f= Frequency in MHz Calculation Formula: Pd = (Pout*G)/(4*pi*r 2 ) Where Pd = power density in mW/cm 2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 r = distance between observation point and center of the radiator in cm Pd is the limit of MPE, 1mW/cm². If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Report No.: S20201228825405 Page Number: 5 of 5 2.2. Test Result of RF Exposure Evaluation Product WYZE PARB BULB Test Item RF Exposure Evaluation Test Mode Frequency Band (MHz) Maximum PK Output Power (dBm) Power Density at R = 20 cm (mW/cm 2 ) Limit (mW/cm 2 ) BLE 2402 ~ 2480 3.35 0.00065 1 Note: / CONCULISON: The Max Power Density at R (20 cm) = 0.00065mW/cm 2 < 1mW/cm 2 . So the EUT complies with the requirement. The End

Test Report

FangguangInspection&TestingCo.,Ltd. HeadquartersAdd.:AreaBofthe3rdfloor,XEDASci-TechPark,XiqingEconomicDevelopmentArea,Tianjin,China Tel:+86-020-66289500-8260Email:[email protected]://www.fgtest.cn TRFNo.:FG.WI-07-Part15SubpartC(15.247)ReportsInquiry:https://grgtest.com PageNumber:1of64 ReportNo.:S20201228825403 IssueDate:03-31-2021 Applicant:WyzeLabs,Inc. Address:5808LakeWashingtonBlvdNESte300KirklandWA 98033 FCCID:2AUIUWYZEP Product:WyzePARBBulb ModelNo.:WYZEPB4025 FCCClassification:DigitalTransmissionSystem(DTS) FCCRulePart(s):Part15SubpartC(15.247) TestProcedure(s):ANSIC63.10-2013,KDB558074D01v05r02 Result:Pass TestDate:January05~January12,2021 MEASUREMENTREPORT FCCPART15.247Bluetooth-LE CompiledBy (AmosXia) SeniorTestEngineer ApprovedBy (KerryZhou) EngineerManager Thetestresultsrelateonlytothesamplestested. Thisequipmenthasbeenshowntobecapableofcompliancewiththeapplicabletechnicalstandards asindicatedinthemeasurementreportandwastestedinaccordancewiththemeasurement proceduresspecifiedinANSIC63.4-2014.Testresultsreportedhereinrelateonlytotheitem(s)tested . ThetestreportshallnotbereproducedexceptinfullwithoutthewrittenapprovalofFangguang Inspection&TestingCo.,Ltd.WuxiBranch Thetestreportmustnotbeusedbytheclienttoclaimproductcertifications,approval,orendorsement byNVLAP,NISToranyagencyofU.S.Government. ReportNo.:S20201228825403 PageNumber: 2 of 64 RevisionHistory ReportNo.VersionDescriptionIssueDate S20201228825403 Rev.01/ 03-31-2021 ReportNo.:S20201228825403 PageNumber: 3 of 64 CONTENTS DescriptionPage §2.1033GeneralInformation ........................................................................................................................ 5 1.INTRODUCTION ........................................................................................................................................... 6 1.1.Scope ................................................................................................................................................... 6 1.2.FangguangTestLocation ................................................................................................................. 6 2.PRODUCTINFORMATION ......................................................................................................................... 7 2.1.EquipmentDescription ...................................................................................................................... 7 2.2.ProductSpecificationSubjectivetothisReport ............................................................................ 7 2.3.OperationFrequency/ChannelList ............................................................................................... 8 2.4.DeviceCapabilities ............................................................................................................................ 8 2.5.DescriptionofTestSoftware ............................................................................................................ 8 2.6.TestMode ........................................................................................................................................... 8 2.7.TestConfiguration ............................................................................................................................. 9 2.8.EMISuppressionDevice(s)/Modifications ..................................................................................... 9 2.9.LabelingRequirements ..................................................................................................................... 9 2.10.Calculationwithallconversionandcorrectionfactorsused ................................................... 10 3.DESCRIPTIONOFTEST .......................................................................................................................... 11 3.1.EvaluationProcedure ...................................................................................................................... 11 3.2.ACLineConductedEmissions ...................................................................................................... 11 3.3.RadiatedEmissions ........................................................................................................................ 12 4.ANTENNAREQUIREMENTS ................................................................................................................... 13 5.TESTEQUIPMENTCALIBRATIONDATE ............................................................................................ 14 6.MEASUREMENTUNCERTAINTY ........................................................................................................... 15 7.TESTRESULT ............................................................................................................................................ 16 7.1.Summary ........................................................................................................................................... 16 7.2.6dBBandwidthMeasurement ....................................................................................................... 17 7.2.1.TestLimit ........................................................................................................................................ 17 7.2.2.TestProcedureused .................................................................................................................... 17 7.2.3.TestSetting .................................................................................................................................... 17 7.2.4.TestSetup ...................................................................................................................................... 17 7.2.5.TestResult ..................................................................................................................................... 18 7.3.OutputPowerMeasurement .......................................................................................................... 21 7.…

Text truncated - open the document above for the full version.

Test Setup Photos

APPENDIX B: PHOTOGRAPH OF THE TEST ARRANGEMENT CE RSE

Contact Information

Applicant

Roy Zhang(Certification Senior Manager)
[email protected]8617600403105Fax: n/a

Technical Contact

FANGGUANG Inspection & Testing Co., Ltd.Sabrina wang
[email protected]61180008-8612

Tianjin · China

Test Firm

Fangguang Inspection & Testing Co. LtdZeming Zhang
[email protected]135-7047-5374

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.20 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Other Applications from Wyze Labs, Inc.

Wyze Cam v4 with BLE and WIFI - FCC ID 2AUIUWYZEC4 - Wyze Labs, Inc.
2AUIUWYZEC4

Wyze Cam v4 with BLE and WIFI

Mar 24, 2024

Equipment Class

DTS - Digital Transmission System
Wyze Cam OG - FCC ID 2AUIUWYZECGSA - Wyze Labs, Inc.
2AUIUWYZECGSA

Wyze Cam OG

Dec 12, 2023

Equipment Class

DTS - Digital Transmission System
Wyze Battery Cam Pro - FCC ID 2AUIUWYZECOP - Wyze Labs, Inc.
2AUIUWYZECOP

Wyze Battery Cam Pro

Jan 31, 2023

Equipment Class

DTS - Digital Transmission System
Wyze Cam OG, Wyze Cam OG Telephoto 3x - FCC ID 2AUIUWYZECGS - Wyze Labs, Inc.
2AUIUWYZECGS

Wyze Cam OG, Wyze Cam OG Telephoto 3x

Jan 15, 2023

Equipment Class

DTS - Digital Transmission System
Wyze Cam Pan v3 with WiFi - FCC ID 2AUIUWYZECPAN3 - Wyze Labs, Inc.
2AUIUWYZECPAN3

Wyze Cam Pan v3 with WiFi

Jan 09, 2023

Equipment Class

DTS - Digital Transmission System