Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
说明书-灯泡和开关 BULB QUICK START GUIDE HOW TO USE SETUP THE BULB PAIRING / SETUP BY Remote 1.Power up the Bulb. 2.Install an AAA battery in the Remote, and pop out ② with yellow light on to start setting.(Note:The setup should be started in 15 mins after the bulb powered up) 3.PRESS ① to pair when the Bulb flashed. Multi bulbs:TURN ① to select Bulb with Bulb flashed, Press the knob to confirm the select. 4.Finally push-in the ② to daily use. 5.Press ① for light on or off, turn ① for brighten or darken. 6.Repeat step 2-4 for pairing with another remote.(Note:Do not setup with different remotes at the same time) MORE FEATURES / SETUP BY APP 1.Download the Wyze app and create an account. 2.Select the plus sign, and follow the instructions. FACTORY RESET Factory reset Remote by pressing and holding the ③ inside the battery cover for at least 3 seconds until the status LED stops flashing. Factory reset Bulb by power the Bulb up and down(Note:With lights go out completely) 5 times and then the Bulb will flash for several times after factory reseted. WARNING AND CAUTION This device is not intended for use with emergency exits or not for emergency lighting. Only use the control provided with or specified by these instructions to control this lamp. This lamp will not operate properly when connected to a standard (incandescent) dimmer or dimming control. Not suitable for use with dimmers unless specifically designed for this product. Not for use in totally enclosed or recessed luminaires. Do not clean the device when it is connected to the power. For safety reason,do not open the device,which will also void the warranty. The device is not designed to be used by children 12 years of age or younger. Manage in accordance with disposal laws in your area. Choking Hazard: This remote contains small parts. Close supervision is recommended when this lamp is used by or near children or by others who may not understand the need for these precautions. Suitable for Damp Locations. Not compatible with photosensor, timers or motion sensor. FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note:This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. The device complies with FCC radiation exposure limits set forth for an uncontrolled environment. The device should be installed and operated with minimum distance of 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This Class B digital device complies with Canadian ICES-005. ISED Statement ‐ English: This device complies with Industry Canada license‐exempt RSS standard(s).Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device.The digital apparatus complies with Canadian CAN ICES‐3 (B)/NMB‐3(B). ‐ French:Le présentappareilestconforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitationestautorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareildoit accepter tout brouillageradioélectriquesubi, mêmesi le brouillageest susceptible d'encompromettre le fonctionnement. Radiation Exposure Statement This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Déclarationd'exposition aux radiations Cetéquipementestconforme Canada limitesd'exposition aux radiations dans un environnement non contrôlé. Cetéquipementdoitêtreinstallé et utilisé à distance minimum de 20cm entre le radiateur et votre corps. Bulb FCC ID:2AUIUWYZEP Bulb IC :25466-WYZEP Remote FCC ID:2AUIUWYZER1 Remote IC :25466-WYZER1 Troubleshooting Problem Solution Light won’t come on There is power to bulb Remote won’t work There is power to the battery and installed correctly. Reset the remote and the bulb(See FACTORY RESET ),then re-pair the bulb with the remote(see HOW TO USE) Limited Warranty This product is covered by a 3 year Limited Warranty.The complete Limited Warranty,warnings and cautions are include inside this packaging,and are also available at www.wyze.com. IN THE BOX Wyze Bulb ×1 Wyze Remote ×1 AAA/LR03 ×1 Manual ×1 SPECIFICATION BULB Model: WYZEPB4025, WYZEPB40 Size: 94.5mm×94.5mm×118mm Rated power: 9.0 watts Lumens: 800 lumens Base type: E26 Working voltage: 120VAC 60Hz Color temper…
Text truncated - open the document above for the full version.
Wyze Labs, Inc. 5808 Lake Washington Blvd NE Ste 300 Kirkland WA 98033 USA Product Similarity Declaration Date: April 1, 2021 FCC ID: 2AUIUWYZER1 Model Number: WYZER1W, WYZER1B, WYZER1G, WYZER1X To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD To Whom It May Concern, We, Wyze Labs, Inc., declare that these 4 EUT (Wyze PARB Remote) Model Numbers listed below are the same on the board, Schematic, Hardware version, Software version, structure and internal photos are same, named differently due to marketing purposes, different color in the same model series. No. Model name Color difference 1 WYZER1W White 2 WYZER1B Black 3 WYZER1G Gray 4 WYZER1X Silvery Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, Name: Steve Skeoch Title: Head of Hardware Company: Wyze Labs, Inc. Address: 5808 Lake Washington Blvd NE Ste 300 Kirkland WA 98033 USA Office: (206) 339 9646, Cell: (858) 218 5969 Email: [email protected]
Wyze Labs, Inc. C5266091_X8_Ed.1 1/1 Letter of Authorization Company: Wyze Labs, Inc. Address: 5808 Lake Washington Blvd NE Ste 300 Kirkland WA 98033 USA Product Name: Wyze PARB Remote Model Number: WYZER1W, WYZER1B, WYZER1G, WYZER1X FCC Identifier: 2AUIUWYZER1 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain,, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain,, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Steve Skeoch Date: April 9, 2021 Title: Head of Hardware Signature of applicant
Wyze Labs, Inc. C5266091_X10_Ed.1 1/1 Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2021.4.1 Subject: Request for Confidentiality FCC ID: 2AUIUWYZER1 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality ID Label/Location No No Attestation Statement No No External Photos No Block Diagram Schematics Test Report No No Test Setup Photos No User’s Manual Internal Photos Parts List / Tune Up RF Exposure Info Operational Description Cover Letter(s) No No SDR Software / Security Info No Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Name: Steve Skeoch Title: Head of Hardware
APPENDIX A. PHOTOGRAPHS OF EUT General view General view General view
APPENDIX A. PHOTOGRAPHS OF EUT Internal view Internal view Internal view RF Module Antenna RF Module
FangguangInspection&TestingCo.,Ltd. Phone:+86-510-68790033 Web:www.fgtest.cn HeadquartersAdd.:AreaBofthe3rdfloor,XEDASci-TechPark,XiqingEconomicDevelopmentArea,Tianjin,China Tel:+86-020-66289500-8260Email:[email protected]://www.fgtest.cn TRFNo.:FG.WI-07-FCCKDB447498ReportsInquiry:https://grgtest.com PageNumber:1of5 FCCRFExposureEvaluationReport ReportNo.:S20210201540805 IssueDate:04-21-2021 Applicant:WyzeLabs,Inc. Address:5808LakeWashingtonBlvdNESte300,Kirkland,WA 98033,USA FCCID:2AUIUWYZER1 ApplicationType:Certification Product:WyzePARBRemote ModelNo.:WYZER1B,WYZER1W,WYZER1G,WYZER1X TradeMark: FCCClassification:DigitalTransmissionSystem(DTS) ReviewedBy (AmosXia) SeniorTestEngineer ApprovedBy (KerryZhou) EngineerManager Thetestresultsrelateonlytothesamplestested. Thetestresultsshowninthetestreportaretraceabletothenational/internationalstandardsthroughthe calibrationoftheequipmentandevaluatedmeasurementuncertaintyherein. ThetestreportshallnotbereproducedexceptinfullwithoutthewrittenapprovalofFangguangInspection& TestingCo.,Ltd. Thetestreportmustnotbeusedbytheclienttoclaimproductcertifications,approval,orendorsementby NVLAP,NISToranyagencyofU.S.Government. ReportNo.:S20210201540805 PageNumber:2of5 RevisionHistory ReportNo.VersionDescriptionIssueDate S20210201540805Rev.01/04-21-2021 ReportNo.:S20210201540805 PageNumber:3of5 1.PRODUCTINFORMATION 1.1.EquipmentDescription ProductName:WyzePARBRemote ModelName:WYZER1B AdditionalModel:WYZER1W\WYZER1G\WYZER1X InputVoltageRange:Battery:AAA/LR03×1,1.5V BluetoothVersion:5.0(1Mbps) AntennaType:PCBAntenna AntennaGain:1.5dBi ReportNo.:S20210201540805 PageNumber:4of5 2.RFExposureEvaluation 2.1.Limits AccordingtoKDB447498D01GeneralRFExposureGuidancev06Section4.3.1StandaloneSAR testexclusionconsiderations:“UnlessspecificallyrequiredbythepublishedRFexposureKDB procedures,standalone1-gheadorbodyand10-gextremitySARevaluationforgeneral populationexposureconditions,bymeasurementornumericalsimulation,isnotrequiredwhenthe correspondingSARTestExclusionThresholdcondition,listedbelow,issatisfied.Thesetest exclusionconditionsarebasedonsource-basedtime-averagedmaximumconductedoutputpower oftheRFchannelrequiringevaluation,adjustedfortune-uptolerance,andtheminimumtest separationdistancerequiredfortheexposureconditions.Theminimumtestseparationdistanceis determinedbythesmallestdistancefromtheantennaandradiatingstructuresoroutersurfaceof thedevice,accordingtothehostformfactor,exposureconditionsandplatformrequirements,to anypartofthebodyorextremityofauserorbystander(see5)ofsection4.1).ToqualifyforSAR testexclusion,thetestseparationdistancesappliedmustbefullyexplainedandjustifiedbythe operatingconfigurationsandexposureconditionsofthetransmitterandapplicablehostplatform requirements,typicallyintheSARmeasurementorSARanalysisreport,accordingtotherequired publishedRFexposureKDBprocedures.WhennootherRFexposuretestingorreportingis required,astatementofjustificationandcompliancemustbeincludedintheequipmentapproval, inlieuoftheSARreport,toqualifyfortheSARtestexclusion.Whenrequired,thedevicespecific conditionsdescribedintheotherpublishedRFexposureKDBproceduresmustbesatisfiedbefore applyingtheseSARtestexclusionprovisions; forexample,handheldPTTtwo-wayradios,handsets,laptops&tabletsetc.“ [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance, mm)]·[VF(GHz)]≤3.0for1-gSARand≤7.5for10-gextremitySAR,where: •f(GHz)istheRFchanneltransmitfrequencyinGHz •PoweranddistanceareroundedtothenearestmWandmmbeforecalculation •Theresultisroundedtoonedecimalplaceforcomparison •3.0and7.5arereferredtoasthenumericthresholdsinthestep2below Thetestexclusionsareapplicableonlywhentheminimumtestseparationdistanceis≤50mm andfortransmissionfrequenciesbetween100MHzand6GHz.Whentheminimumtest separationdistanceis<5mm,adistanceof5mmaccordingtof)insection4.1isappliedto determineSARtestexclusion. ReportNo.:S20210201540805 PageNumber:5of5 2.2.CalculationMethod [(max.powerof`channel,includingtune-uptolerance,mW)/(min.testseparationdistance, mm)]·[√f(GHz)]≤3.0 ConductedPower+tuneuptolerance=3.88dBm=2.44mW Distance=5mm f=2.402 [2.44/5]*SQRT(2.402)=0.757 0.757≤3.0 Therefore,excludedfromSARtesting. CONCULISON: ThemeasurementresultscomplywiththeFCCLimitper47CFR2.1093fortheuncontrolledRF ExposureandSARExclusionThresholdperKDB447498v06. TheEnd
FangguangInspection&TestingCo.,Ltd. HeadquartersAdd.:AreaBofthe3rdfloor,XEDASci-TechPark,XiqingEconomicDevelopmentArea,Tianjin,China Tel:+86-020-66289500-8260Email:[email protected]://www.fgtest.cn TRFNo.:FG.WI-07-Part15SubpartC(15.247)ReportsInquiry:https://grgtest.com PageNumber:1of60 ReportNo.:S20210201540803 IssueDate:04-21-2021 Applicant:WyzeLabs,Inc. Address:5808LakeWashingtonBlvdNESte300,Kirkland,WA 98033,USA FCCID:2AUIUWYZER1 Product:WyzePARBRemote ModelNo.:WYZER1B,WYZER1W,WYZER1G,WYZER1X FCCClassification:DigitalTransmissionSystem(DTS) FCCRulePart(s):Part15SubpartC(15.247) TestProcedure(s):ANSIC63.10-2013,KDB558074D01v05r02 Result:Pass TestDate:March26~April09,2021 MEASUREMENTREPORT FCCPART15.247Bluetooth-LE CompiledBy (AmosXia) SeniorTestEngineer ApprovedBy (KerryZhou) EngineerManager Thetestresultsrelateonlytothesamplestested. Thisequipmenthasbeenshowntobecapableofcompliancewiththeapplicabletechnicalstandards asindicatedinthemeasurementreportandwastestedinaccordancewiththemeasurement proceduresspecifiedinANSIC63.4-2014.Testresultsreportedhereinrelateonlytotheitem(s)tested . ThetestreportshallnotbereproducedexceptinfullwithoutthewrittenapprovalofFangguang Inspection&TestingCo.,Ltd.WuxiBranch Thetestreportmustnotbeusedbytheclienttoclaimproductcertifications,approval,orendorsement byNVLAP,NISToranyagencyofU.S.Government. ReportNo.:S20210201540803 PageNumber: 2 of 60 RevisionHistory ReportNo.VersionDescriptionIssueDate S20210201540803 Rev.01/04-21-2021 ReportNo.:S20210201540803 PageNumber: 3 of 60 CONTENTS DescriptionPage §2.1033GeneralInformation ........................................................................................................................ 5 1.INTRODUCTION ........................................................................................................................................... 6 1.1.Scope ................................................................................................................................................... 6 1.2.FangguangTestLocation ................................................................................................................. 6 2.PRODUCTINFORMATION ......................................................................................................................... 7 2.1.EquipmentDescription ...................................................................................................................... 7 2.2.ProductSpecificationSubjectivetothisReport ............................................................................ 7 2.3.OperationFrequency/ChannelList ............................................................................................... 8 2.4.DeviceCapabilities ............................................................................................................................ 8 2.5.DescriptionofTestSoftware ............................................................................................................ 8 2.6.TestMode ........................................................................................................................................... 8 2.7.TestConfiguration ............................................................................................................................. 9 2.8.EMISuppressionDevice(s)/Modifications ..................................................................................... 9 2.9.LabelingRequirements ..................................................................................................................... 9 2.10.Calculationwithallconversionandcorrectionfactorsused ................................................... 10 3.DESCRIPTIONOFTEST .......................................................................................................................... 11 3.1.EvaluationProcedure ...................................................................................................................... 11 3.2.ACLineConductedEmissions ...................................................................................................... 11 3.3.RadiatedEmissions ........................................................................................................................ 12 4.ANTENNAREQUIREMENTS ................................................................................................................... 13 5.TESTEQUIPMENTCALIBRATIONDATE ............................................................................................ 14 6.MEASUREMENTUNCERTAINTY ........................................................................................................... 15 7.TESTRESULT ............................................................................................................................................ 16 7.1.Summary ........................................................................................................................................... 16 7.2.6dBBandwidthMeasurement ....................................................................................................... 17 7.2.1.TestLimit ........................................................................................................................................ 17 7.2.2.TestProcedureused .................................................................................................................... 17 7.2.3.TestSetting .................................................................................................................................... 17 7.2.4.TestSetup ...................................................................................................................................... 17 7.2.5.TestResult ..................................................................................................................................... 18 7.3.OutputPowerMeasurement .......................................................................................…
Text truncated - open the document above for the full version.
APPENDIX B: PHOTOGRAPH OF THE TEST ARRANGEMENT RSE RSE
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 2.16 mW |

Wyze Cam v4 with BLE and WIFI
Equipment Class
DTS - Digital Transmission System
Wyze Cam OG
Equipment Class
DTS - Digital Transmission System
Wyze Battery Cam Pro
Equipment Class
DTS - Digital Transmission System
Wyze Cam OG, Wyze Cam OG Telephoto 3x
Equipment Class
DTS - Digital Transmission System
Wyze Cam Pan v3 with WiFi
Equipment Class
DTS - Digital Transmission System