AttestationStatement. Old Code:C526609124New Code:00015544Ed.3 Changereason:FRN is addedto the Applicantinformationsection. 1/1 TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: Xiamen Hanin Co.,Ltd. Grantee code: 2AUTE FCC ID: 2AUTE-2D29 FRN: 0028895233 Contact Name: Jeff Wang Address: Room 305A, Angye Building, Pioneering Park, Torch High-tech, Zone, Xiamen Telephone No: 13799700032 Fax No: / Email: [email protected] i.[XiamenHaninCo.,Ltd.] (“theapplicant”) certifiesthattheequipmentfor whichauthorizationissoughtisnot“covered” equipmentprohibitedfrom receivinganequipmentauthorizationpursuanttosection2.903oftheFCC rules.Theapplicantmustsignthiscertification. ii.[XiamenHaninCo.,Ltd.] (“theapplicant”) certifiesthat,asofthedateofthe filingoftheapplication,theapplicantis not(asa specificallynamedentityor anyofitssubsidiariesoraffiliates)identifiedontheCoveredListasanentity producing“covered” equipment.Theapplicantmustsignthiscertification. [Xiamen Hanin Co.,Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List as an entity producing “covered” equipment . Date: 06/15/2026 Applicant’s Name:Jeff Wang Title: Manager Signature 1 The Commission’s CoveredListis publishedby the PublicSafetyand HomelandSecurityBureauand postedon the Commission’s website.This CoveredList, whichis periodicallyupdated,identifiesparticularequipment,producedby particularentities,that constitutes“covered”equipment.https://www.fcc.gov/supplychain/coveredlist
Xiamen Hanin Co.,Ltd. Code 00018768 Ed. 1 DeviceBarcode Printer, Label Printer, Barcode Label Printer , Direct Thermal Printer, Direct Thermal Label Printer Company nameXiamen Hanin Co.,Ltd. Grantee code2AUTE FCC ID2AUTE-2D29 FRN0028895233 Contact nameJeff Wang AddressRoom 305A, Angye Building, Pioneering Park, Torch High-tech, Zone, Xiamen Telephone number13799700032 [email protected] Chipset/module information BT Chip: BR8051A01 WiFi Chip: AJ2507 GD32EPRTVDT6 Operating System (if applicable)N/A Storage Capacity (hard drive or other permanent memory storage, if applicable) N/A 2 Item1.Thedeviceisabletoinstallsoftware/programinstallation? ☐Yes,gotoItem2. ☒No.Inthiscase,therestoftheitemsdonotapply.ThedevicecannotsupportinstallationofKaspersky cybersecurityoranti-virussoftware. Item2.TechnicalRequirementsforKasperskyCybersecuritySoftware: #GeneralRequirements(ForallDevices)Yes/NoorN/AComments 1Internetconnectionforactivationandupdates(ForallOperating Systems) NON/A #GeneralRequirements(ForWindowsDevices)Yes/NoorN/AComments 1Storage:1500MBfreespaceontheharddriveNON/A 2OperatingSystem: MicrosoftWindows8,8.1,10&11Home/Pro/Enterprise Microsoft Windows7Starter/HomeBasic&Premium/Professional/ UltimateSP1orhigher NON/A 3Processor:1GHzorhigher(x86orx64)NON/A 4Memory(RAM)1GB(32-bit)or2GB(64-bit)NON/A 5ScreenResolution:Minimumresolutionof1024x768NON/A #GeneralRequirements(FormacOSdevices)Yes/NoorN/AComments 1OperatingSystemmacOS®13–14NON/A 2Memory(RAM)4GBNON/A 3Storage:3455MBfreespaceontheharddriveNON/A 3 #GeneralRequirements(ForAndroidDevices)Yes/NoorN/AComments 1Storage:150MBfreespaceNON/A 2OperatingSystem:Android™10–14NON/A 3ScreenResolution:Minimumresolutionof320x480NON/A #GeneralRequirements(foriOSdevices)Yes/NoorN/AComments 1Storage:150MBfreespaceNON/A 2OperatingSystem:iOS®17NON/A Afterreviewedthetechnicalrequirements,isthedevicecapableofsupportingtheinstallationof Kasperskysoftware? ☐Yes,gotoItem3. ☒ No.Inthiscase,therestoftheitemsdonotapply.ThedevicecannotsupportinstallationofKaspersky software Item3.ConnectivityCapabilities: #PhysicalInterfacePurposeJustification 1 1 #WirelessInterfacePurposeJustification 1 1 Afterthereviewofthisitems,thedevice: ☒Cannotsupportinstallationofanycybersecurityoranti-virussoftwareonthecoveredlist. 1 Thejustificationfieldisusedtojustifywhythesoftwarecannotbereceivedthroughthatinterface.Checktheannexformore indications. 4 ☐Potentiallycanoperatewithanycybersecurityoranti-virussoftwareonthecoveredlist–additionalthird- partyproofisprovidedtodemonstratecompliancewithrequirementsasof2.911(d)5(i),(ii)–“Proofof CompliancewithCoveredListSoftwareRequirements”ofthisdocumentapplies Signature:Name:JeffWang Date:2026-06-18
XiamenHaninCo.,Ltd. Room305A,AngyeBuilding,PioneerPark,TorchHigh-techZone,XiamenCity,Fujian Province,P.R.China. ModelDifferenceletter Date:2026-06-16 Towhomitmayconcern, WeXiamenHaninCo.,Ltd./Room305A,AngyeBuilding, PioneerPark,TorchHigh-techZone,XiamenCity,Fujian Province,P.R.China. Wouldliketodeclaredthat Product:BarcodePrinter,LabelPrinter,BarcodeLabelPrinter, DirectThermalPrinter,DirectThermalLabelPrinter Models:HID-2D2529,iF2L,iF200L,iH2L,K2-20U,D2-20U,P2- 30A,FL200,FL230,XL200,XL230,SL200,SL230,NL200,NL230, EL200,EL230,JL200,JL230,L20,L23,SL201,SL203,NL200, JL200,JL203,L201,L203,iL230,L200,L230,DL200,DL230, DL200,DL230,L2,KL200,KL230,FDL200,SDL200,XDL500, XDL530,DLP200,DLP230,XF231,XF232,IF230,HF230,BL230, JL230,NS230,PE230,PW230,YD230,YD220,YD210,TLD23 allpartsoftheproduct,includingthecircuittheory,electrical design,thecriticalcomponentsandBOMmaterialsarethe sameexceptformodelnameandproductname. Sincerely Signature: Name/title:jeffwangmanager
TCB CALL página 1 File FCC ID: 2AUTE-2D29 Please upload an exhibit that explains how does the TCB verify the new agent information: 1- Is the address of the agent a valid physical US mailing address (not a US post office box, not a virtual mailbox, not P.O. Boxes, not a vacant lot, not a public building, etc.) ○ We have checked if the address exists in a real and potential building (Google maps) + official US register, after this verification and the evidence below we can guarantee the following: not a US post office box not a virtual mailbox not P.O. Boxes not a vacant lot not a public building(note) ► We checked the FCC FRN Search based on the information provided by the grantee. On the official register from CALIFORNIA: https://www.sanjoseca.gov/your-government/departments-offices/finance/business-tax-registration/business-tax-lookup TCB CALL página 2 In google: However after deeply investigate I could see: TCB CALL página 3 ► CONCLUSION by TCB: The ASOP defined and provided by grantee is VALID and confirmed. Therefore the exhibit "FCC Agent for service Attestation from Agent&FCC Agent for service Attestation from Applicant" included in the file is ok. 2- Is the agent physically located at that valid US address such that the agent can be legally served at that address? Yes , check above 3- Has the listed agent clearly agreed in writing to serve as the agent for the grantee at that address? Yes, it is included in the exhibit " FCC Agent for service Attestation from Agent&FCC Agent for service Attestation from Applicant " >
C5266091_X10_Ed.2 1/1 XiamenHaninCo.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date: Subject:RequestforConfidentiality FCCID:2AUTE-2D29 ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality NOTE2 IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo ☒ BlockDiagram ☒☐ Schematics ☒☐ TestReportNoNo TestSetupPhotosNo ☒ User’sManual ☐ NOTE 1 ☒ InternalPhotos ☐ NOTE 1 ☒ PartsList/TuneUp ☒☐ RFExposureInfoNoNo OperationalDescription ☒☐ CoverLetter(s)NoNo SDRSoftware/SecurityInfo ☐ No NOTE1:Long-TermConfidentialitymaybepermittedunderspecialconditions(SeeII.LONG-TERMCONFIDENTIALITY,Section3of KDB726920,uselastinforce) NOTE2:Short-TermConfidentialitycanberequestedforamaximumof180daysfromthedateofthegrant. Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Incaseofshort-termConfidentiality,theapplicantrequeststheexhibitsselected abovearewithheldfrompublicviewforaperiodof_180__daysfromthedateofthe GrantofEquipmentAuthorizationandpriortomarketing. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name:JeffWang Title:Manager
C5266091_X8_Ed.1 1/1 LetterofAuthorization XiamenHaninCo.,Ltd. Company:XiamenHaninCo.,Ltd. Address:Room305A,AngyeBuilding,PioneerPark,TorchHigh-tech Zone,XiamenCity,FujianProvince,China ProductName:BarcodePrinter,LabelPrinter,BarcodeLabelPrinter, DirectThermalPrinter,DirectThermalLabelPrinter ModelNumber:iF2,iF200,iH2,iH200,FD200,FD230,XD200,XD230, SF200,SF230,NF200,ND230,EF200,EF230,JF200,JF230,Y20,Y23, SF201,SF203,NF200,J200,J203,Y201,Y203,iF230,X200,X230, D200,D230,D200,D230,F2,F200,F230,JD200,SD200,XD500, XD530,TLP200,TLP230,X231,X232,I230,H230,B230,J230,N230, S230,E230,W230,Y230,Y220,Y210,TLP23 FCCIdentifier:2AUTE-2D29 WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:JeffWangDate:2026.6.16 Title:Manager Signatureofapplicant:
FCCID:2AUTE-2D29 RFExposureEvaluation AccordingtoKDB447498D01GeneralRFExposureGuidancev06andpart2.1091,Unlessspecifically requiredbythepublishedRFexposureKDBprocedures,standalone1-gheadorbodyand10-gextremity SARevaluationforgeneralpopulationexposureconditions,bymeasurementornumericalsimulation,isnot requiredwhenthecorrespondingSARTestExclusionThresholdcondition(s),listedbelow,is(are)satisfied. Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhumanexposure toradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Frequencyrange (MHz) Electricfield strength (V/m) Magneticfieldstrength (A/m) Powerdensity (mW/cm 2 ) Averagingtime (minutes) (A)LimitsforOccupational/ControlledExposures 0.3–3.06141.63*(100)6 3.0–301842/f4.89/f*(900/f 2 )6 30–30061.40.1631.06 300–1500f/3006 1500–100,00056 (B)LimitsforGeneralPopulation/UncontrolledExposure 0.3–1.346141.63*(100)30 1.34–30824/f2.19/f*(180/f 2 )30 30–30027.50.0730.230 300–1500f/150030 1500–100,0001.030 f=frequencyinMHz Friistransmissionformula:Pd=(Pout*G)/(4*pi*r 2 ) Where Pd=powerdensityinmW/cm 2 ,Pout=outputpowertoantennainmW; G=gainofantennainlinearscale,Pi=3.1416; R=distancebetweenobservationpointandcenteroftheradiatorincm PdidthelimitofMPE,1mW/cm 2 .Ifweknowthemaximumgainoftheantennaandthetotalpowerinputto theantenna,throughthecalculation,wewillknowthedistancerwheretheMPElimitisreached. TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleandhighest channelindividually. TestResultofRFExposureEvaluation Remark: 1.BLE1M,BR&EDRdonottransmitatthesametime BT,WiFicantransmitatthesametime 2.InthecaseofsimultaneouslaunchesforandBTandWiFi: TheMaxCalc.Thresholds:0.0008/1.0+0.0307/1.0=0.0315<1 SoaSARtestisnotrequired OperatingMode Measured Power Tuneup tolerance Max.Tune upPower Antenna Gain Power Densityat R=20cm Power Density Limit Result (dBm)(dBm)(dBm)(dBi)(mW/cm 2 )(mW/cm 2 ) BLE1M4.18 4±1 50.950.00081.0PASS BR&EDR-1.52 -1±1 00.950.00021.0PASS WiFi2.4G16.20 16±1 174.890.03071.0PASS
SZNTT-TR827-0Page1of36 Hotline:0755-27889935http://www.ntt-testing.com FCCTESTREPORT FCCID:2AUTE-2D29 Product: BarcodePrinter ModelName: HID-2D2529 Brand: N/A ReportNo.:SZNTT26021758E1-2 Preparedfor XiamenHaninCo.,Ltd. Room305A,AngyeBuilding,PioneeringPark,TorchHigh-tech,Zone,Xiamen Preparedby ShenzhenNTTTestingTechnologyCo.,Ltd. 1B,Building2,FactoryBuilding&103,Building3,FactoryBuilding,DayangIndustrial ParkNo.4,IndustrialAvenue,TangweiCommunity,FuhaiSub-district,Bao'anDistrict, ShenzhenCity,China TEL:0755-27889935 ReportNo.:SZNTT26021758E1-2 SZNTT-TR827-0Page2of36 Hotline:0755-27889935http://www.ntt-testing.com 1TESTRESULTCERTIFICATION Applicant’sname:XiamenHaninCo.,Ltd. Address: Room305A,AngyeBuilding,PioneeringPark,TorchHigh-tech,Zone, Xiamen Manufacture's name :XiamenHaninCo.,Ltd. Address: Room305A,AngyeBuilding,PioneeringPark,TorchHigh-tech,Zone, Xiamen ProductName :BarcodePrinter AdditionalProduct Name LabelPrinter,BarcodeLabelPrinter,DirectThermalPrinter, DirectThermalLabelPrinter ModelName :HID-2D2529 Additionalmodel: iF2L,iF200L,iH2L,K2-20U,D2-20U,P2-30A,FL200,FL230,XL200,XL230, SL200,SL230,NL200,NL230,EL200,EL230,JL200,JL230,L20,L23,SL201, SL203,NL200,JL200,JL203,L201,L203,iL230,L200,L230,DL200,DL230, DL200,DL230,L2,KL200,KL230,FDL200,SDL200,XDL500,XDL530,DLP200, DLP230,XF231,XF232,IF230,HF230,BL230,JL230,NS230,PE230,PW230, YD230,YD220,YD210,TLD23 Standards:FCCCFR47Part15Section15.247 Testprocedure: ANSIC63.10-2020+Cor.1-2023 KDB558074D0115.247MeasGuidancev05r02 TestDate:Mar.04,2026toJul.15,2026 DateofIssue:Jul.15,2026 TestResult:Pass ThisdevicedescribedabovehasbeentestedbyNTT,andthetestresultsshowthatthe equipmentundertest(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonly tothetestedsampleidentifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofNTT,this documentmaybealteredorrevisedbyNTT,personalonly,andshallbenotedintherevisionof thedocument. Preparedby(TestEngineer): ZhaoDi ReportNo.:SZNTT26021758E1-2 SZNTT-TR827-0Page3of36 Hotline:0755-27889935http://www.ntt-testing.com Reviewer(Supervisor): KenWu Approved(Manager): AbelYu ReportNo.:SZNTT26021758E1-2 SZNTT-TR827-0Page4of36 Hotline:0755-27889935http://www.ntt-testing.com Contents Page 1TESTRESULTCERTIFICATION...................................................................................................................2 2TESTSUMMARY............................................................................................................................................6 3TESTFACILITY...............................................................................................................................................7 4GENERALINFORMATION.............................................................................................................................8 4.1GENERALDESCRIPTIONOFE.U.T..........................................................................................................8 4.2CHANNELLIST.......................................................................................................................................9 4.3TESTSETUPCONFIGURATION..............................................................................................................10 4.4TESTCONFIGURATION..........................................................................................................................10 5EQUIPMENTDURINGTEST........................................................................................................................11 5.1EQUIPMENTSLIST................................................................................................................................11 5.2MEASUREMENTUNCERTAINTY..............................................................................................................13 5.3DESCRIPTIONOFSUPPORTUNITS........................................................................................................13 6CONDUCTEDEMISSION.............................................................................................................................14 6.1E.U.T.OPERATION..............................................................................................................................14 6.2EUTSETUP.........................................................................................................................................14 6.3TESTSET-UP(BLOCKDIAGRAMOFCONFIGURATION).........................................................................14 6.4MEASUREMENTPROCEDURE:...............................................................................................................15 6.5CONDUCTEDEMISSIONLIMIT................................................................................................................15 6.6MEASUREMENTDESCRIPTION...............................................................................................................15 6.7CONDUCTEDEMISSIONTESTRESULT...................................................................................................15 7RADIATEDSPURIOUSEMISSIONS...........................................................................................................18 7.1EUTOPERATION.................................................................................................................................18 7.2TESTSETUP........................................................................................................................................19 7.3SPECTRUMANALYZERSETUP...............................................................................................................20 7.4TESTPROCEDURE...............................................................................................................................20 7.5SUMMARYOFTESTRESULTS...............................................................................................................21 8MAXIMUMPEAKOUTPUTPOWERTEST......................................…
Text truncated - open the document above for the full version.
AntennaInformation 1.Manufacturer’sname:XiamenHaninCo.,Ltd. 2.manufacturer’saddress:Room305A,AngyeBuilding,PioneeringPark,TorchHigh- tech,Zone,Xiamen 3.Antennamodelname:HID-BT2 4.PeakAntennaGainResults Frequency/MHz240024502500 PeakGain/dBi0.840.950.90 15.0×5.6mm
ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page1of35 RFTestData MaximumPeakConductedOutputPower..................................................................................................................................................2 -20dBBandwidth........................................................................................................................................................................................6 OccupiedChannelBandwidth..................................................................................................................................................................10 CarrierFrequenciesSeparation................................................................................................................................................................14 NumberofHoppingChannel....................................................................................................................................................................16 BandEdge................................................................................................................................................................................................18 ConductedRFSpuriousEmission............................................................................................................................................................22 DwellTime................................................................................................................................................................................................30 ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page2of35 MaximumPeakConductedOutputPower TestModeAntenna Frequency [MHz] Peak Power [dBm] Limit [dBm] Verdict DH5Ant12402-4.67≤20.97PASS DH5Ant12441-2.85≤20.97PASS DH5Ant12480-1.52≤20.97PASS 2DH5Ant12402-4.78≤20.97PASS 2DH5Ant12441-2.93≤20.97PASS 2DH5Ant12480-1.56≤20.97PASS 3DH5Ant12402-4.75≤20.97PASS 3DH5Ant12441-2.97≤20.97PASS 3DH5Ant12480-1.66≤20.97PASS ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page3of35 DH5-Ant1-2402-PASSDH5-Ant1-2441-PASS DH5-Ant1-2480-PASS2DH5-Ant1-2402-PASS ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page4of35 2DH5-Ant1-2441-PASS2DH5-Ant1-2480-PASS 3DH5-Ant1-2402-PASS3DH5-Ant1-2441-PASS ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page5of35 3DH5-Ant1-2480-PASS ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page6of35 -20dBBandwidth TestModeAntennaFreq(MHz)20dBEBW[MHz]FL[MHz]FH[MHz]Limit[MHz]Verdict DH5Ant124020.9602401.5262402.486------ DH5Ant124410.9572440.5292441.486------ DH5Ant124800.9572479.5262480.483------ 2DH5Ant124021.2422401.3762402.618------ 2DH5Ant124411.2812440.3672441.648------ 2DH5Ant124801.2392479.3732480.612------ 3DH5Ant124021.2572401.3612402.618------ 3DH5Ant124411.2572440.3612441.618------ 3DH5Ant124801.2452479.3702480.615------ ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page7of35 DH5-Ant1-2402DH5-Ant1-2441 DH5-Ant1-24802DH5-Ant1-2402 ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page8of35 2DH5-Ant1-24412DH5-Ant1-2480 3DH5-Ant1-24023DH5-Ant1-2441 ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page9of35 3DH5-Ant1-2480 ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page10of35 OccupiedChannelBandwidth TestModeAntennaFreq(MHz)OCB[MHz]FL[MHz]FH[MHz]Limit[MHz]Verdict DH5Ant124020.876712401.55872402.4354------ DH5Ant124410.863732440.56422441.4280------ DH5Ant124800.856822479.56562480.4224------ 2DH5Ant124021.16112401.41592402.5770------ 2DH5Ant124411.15042440.42172441.5721------ 2DH5Ant124801.14242479.42532480.5677------ 3DH5Ant124021.14562401.42892402.5745------ 3DH5Ant124411.14672440.42762441.5743------ 3DH5Ant124801.14942479.42532480.5747------ ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page11of35 DH5-Ant1-2402DH5-Ant1-2441 DH5-Ant1-24802DH5-Ant1-2402 ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page12of35 2DH5-Ant1-24412DH5-Ant1-2480 3DH5-Ant1-24023DH5-Ant1-2441 ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page13of35 3DH5-Ant1-2480 ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page14of35 CarrierFrequenciesSeparation TestModeAntennaFreq(MHz)Result[MHz]Limit[MHz]Verdict DH5Ant1Hop0.846≥0.640PASS 2DH5Ant1Hop1.324≥1.281PASS 3DH5Ant1Hop1.158≥0.838PASS ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page15of35 DH5-Ant1-Hop-PASS2DH5-Ant1-Hop-PASS 3DH5-Ant1-Hop-PASS ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page16of35 NumberofHoppingChannel TestModeAntennaFreq(MHz)Result[Num]Limit[Num]Verdict DH5Ant1Hop79≥15PASS 2DH5Ant1Hop79≥15PASS 3DH5Ant1Hop79≥15PASS ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page17of35 DH5-Ant1-Hop-PASS2DH5-Ant1-Hop-PASS 3DH5-Ant1-Hop-PASS ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page18of35 BandEdge TestModeAntennaChNameFreq(MHz) RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5Ant1Low2402-5.66-44.56≤-25.66PASS DH5Ant1High2480-2.44-43.91≤-22.44PASS DH5Ant1LowHop_2402-1.78-52.06≤-25.93PASS DH5Ant1HighHop_2480-0.01-52.64≤-22.81PASS 2DH5Ant1Low2402-5.68-46.88≤-25.68PASS 2DH5Ant1High2480-2.51-47.94≤-22.51PASS 2DH5Ant1LowHop_2402-0.11-43.15≤-26.22PASS 2DH5Ant1HighHop_2480-0.89-49.87≤-23.25PASS 3DH5Ant1Low2402-5.54-47.09≤-25.54PASS 3DH5Ant1High2480-2.41-48.77≤-22.41PASS 3DH5Ant1LowHop_2402-6.59-56.13≤-31.89PASS 3DH5Ant1HighHop_24801.65-52.19≤-23.73PASS
ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page19of35 DH5-Ant1-2402-PASSDH5-Ant1-2480-PASS DH5-Ant1-Hop_2402-PASSDH5-Ant1-Hop_2480-PASS ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page20of35 2DH5-Ant1-2402-PASS2DH5-Ant1-2480-PASS 2DH5-Ant1-Hop_2402-PASS2DH5-Ant1-Hop_2480-PASS ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page21of35 3DH5-Ant1-2402-PASS3DH5-Ant1-2480-PASS 3DH5-Ant1-Hop_2402-PASS3DH5-Ant1-Hop_2480-PASS ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page22of35 ConductedRFSpuriousEmission TestModeAntennaFreq(MHz) FreqRange [MHz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5Ant124020~Reference-5.10-5.10---PASS DH5Ant1240230~1000-5.10-62.12≤-25.1PASS DH5Ant124021000~26500-5.10-42.49≤-25.1PASS DH5Ant124410~Reference-3.38-3.38---PASS DH5Ant1244130~1000-3.38-61.76≤-23.38PASS DH5Ant124411000~26500-3.38-39.57≤-23.38PASS DH5Ant124800~Reference-2.01-2.01---PASS DH5Ant1248030~1000-2.01-61.82≤-22.01PASS DH5Ant124801000~26500-2.01-37.84≤-22.01PASS 2DH5Ant124020~Reference-5.36-5.36---PASS 2DH5Ant1240230~1000-5.36-61.8≤-25.36PASS 2DH5Ant124021000~26500-5.36-44.13≤-25.36PASS 2DH5Ant124410~Reference-3.58-3.58---PASS 2DH5Ant1244130~1000-3.58-61.43≤-23.58PASS 2DH5Ant124411000~26500-3.58-47.11≤-23.58PASS 2DH5Ant124800~Reference-2.23-2.23---PASS 2DH5Ant1248030~1000-2.23-61.37≤-22.23PASS 2DH5Ant124801000~26500-2.23-42.94≤-22.23PASS 3DH5Ant124020~Reference-5.22-5.22---PASS 3DH5Ant1240230~1000-5.22-61.78≤-25.22PASS 3DH5Ant124021000~26500-5.22-49.49≤-25.22PASS 3DH5Ant124410~Reference-3.36-3.36---PASS 3DH5Ant1244130~1000-3.36-61.27≤-23.36PASS 3DH5Ant124411000~26500-3.36-48.37≤-23.36PASS 3DH5Ant124800~Reference-2.05-2.05---PASS 3DH5Ant1248030~1000-2.05-61.44≤-22.05PASS 3DH5Ant124801000~26500-2.05-41.91≤-22.05PASS ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page23of35 DH5-Ant1-2402-0~Reference-PASSDH5-Ant1-2402-30~1000-PASS DH5-Ant1-2402-1000~26500-PASSDH5-Ant1-2441-0~Reference-PASS ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page24of35 DH5-Ant1-2441-30~1000-PASSDH5-Ant1-2441-1000~26500-PASS DH5-Ant1-2480-0~Reference-PASSDH5-Ant1-2480-30~1000-PASS ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page25of35 DH5-Ant1-2480-1000~26500-PASS2DH5-Ant1-2402-0~Reference-PASS 2DH5-Ant1-2402-30~1000-PASS2DH5-Ant1-2402-1000~26500-PASS ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page26of35 2DH5-Ant1-2441-0~Reference-PASS2DH5-Ant1-2441-30~1000-PASS 2DH5-Ant1-2441-1000~26500-PASS2DH5-Ant1-2480-0~Reference-PASS ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page27of35 2DH5-Ant1-2480-30~1000-PASS2DH5-Ant1-2480-1000~26500-PASS 3DH5-Ant1-2402-0~Reference-PASS3DH5-Ant1-2402-30~1000-PASS ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page28of35 3DH5-Ant1-2402-1000~26500-PASS3DH5-Ant1-2441-0~Reference-PASS 3DH5-Ant1-2441-30~1000-PASS3DH5-Ant1-2441-1000~26500-PASS ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page29of35 3DH5-Ant1-2480-0~Reference-PASS3DH5-Ant1-2480-30~1000-PASS 3DH5-Ant1-2480-1000~26500-PASS ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page30of35 DwellTime TestModeAntennaFreq(MHz) BurstWidth [ms] TotalHops [Num] Result[s]Limit[s]Verdict DH1Ant1Hop0.3743300.123≤0.4PASS DH3Ant1Hop1.6311700.277≤0.4PASS DH5Ant1Hop2.8791300.374≤0.4PASS 2DH1Ant1Hop0.3843300.127≤0.4PASS 2DH3Ant1Hop1.6371800.295≤0.4PASS 2DH5Ant1Hop2.8841300.375≤0.4PASS 3DH1Ant1Hop0.3853200.123≤0.4PASS 3DH3Ant1Hop1.6351600.262≤0.4PASS 3DH5Ant1Hop2.8871300.375≤0.4PASS ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page31of35 DH1-Ant1-Hop-PASSDH1-Ant1-Hop-PASS DH3-Ant1-Hop-PASSDH3-Ant1-Hop-PASS ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page32of35 DH5-Ant1-Hop-PASSDH5-Ant1-Hop-PASS 2DH1-Ant1-Hop-PASS2DH1-Ant1-Hop-PASS ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page33of35 2DH3-Ant1-Hop-PASS2DH3-Ant1-Hop-PASS 2DH5-Ant1-Hop-PASS2DH5-Ant1-Hop-PASS ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page34of35 3DH1-Ant1-Hop-PASS3DH1-Ant1-Hop-PASS 3DH3-Ant1-Hop-PASS3DH3-Ant1-Hop-PASS ReportNo.:SZNTT26021758E1-2 SZNTT-TR728-0Page35of35 3DH5-Ant1-Hop-PASS3DH5-Ant1-Hop-PASS
3313 Verdi Dr, San Jose, CA 95111, USA · San Jose, California, 95111 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 700.00 µW |

Portable Photo Printer
Equipment Class
DTS - Digital Transmission System
Mobile Printer
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Barcode Printer
Equipment Class
NII - Unlicensed National Information Infrastructure TX
1) Portable Photo Printer, 2) Mini Photo Printer, 3) Dye-Sublimation Photo Printer, 4) Photo Printer
Equipment Class
DTS - Digital Transmission SystemThermal Receipt Printer
Equipment Class
DTS - Digital Transmission System