FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ALOYS INC./
  3. 2AV9UFZ104

2AV9UFZ104Android Media Player

ALOYS INC.
Android Media Player - FCC ID 2AV9UFZ104 - ALOYS INC.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 18, 2022
Application Purpose
Original Equipment
Date of Application
Sep 18, 2022
Equipment Note
Android Media Player
Frequency Range
2412.00000000 - 2462.00000000
Company
ALOYS INC.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

Test Report

↗
↗
↗
↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Installation Guide _ 0 Connect your FORMULER to your TV with an HDMI cable. 行 8 Connect your FORMULER to power using the power cord 色 E) Turn on your TV and switch to the cor『ectHDMI input 巳0 Set-up your FORMULER and connect to your local network 艺气; _ 8 Install your favorite apps to enjoy streaming contents• _ What's in the Box? If;;} ` Media Receiver Remote Control ` ` Remote Control Extender 2x Batteries 文 ` TV Cable Power Adapter lnstallationsanleitung _ 0 Verbinden Sie lhre FORMULER und den Fernseher mil einem HDMI Kabel. 行8 SchlieBen Sie lhre FORMULER Ober das Netzkabel an die Stromversorgung an. 色 8 Schalten Sie 1hr Fernsehge闭tein und wechseln Sie zum richtigen HDMI-Eingang 巳0 Rich t e n Sie lhre FORMULER ein und s tellen Sie eine V erbindung zum lokalen Netzwerk her. 艺气; 8 lnstallieren Sie lhre gewiinschten Apps um die Streaming - Angebote geniel!en zu konnen• _ Was ist in der Box? (£;) Medienempfanger Fernbedienung 气 ` Fernbedienung Extender 2 x Batterien 文 ` TV-Kabel Netzteil RED Declaration FORMULER hereby declares that this wi『elessdevice complies with all material requirements and other『elevantprovisions of the 2014/53/EU Directive. A copy of the Declaration of Conformity may be obtained directly from COBOPLUS [C/ INDEPENDENCIA, N2 BAJO DERECHA A y 8, 28013, MADRID, SPAIN) For technical support, 『egulatorycompliance information, and use『guide,visit https;t /support. formuler.tv SAFETY INFORMATION FORMULER products a『e designed to operate safely when installed and used acco灿ngto the product instructions and general safety practices. The guidelines included in this document explain the potential『isksassociated with equipment operation and p『ovideimportant safety practices designed to min血izethese risks. By ca『efullyfollowing the information contained in this document, you can protect yourself from haza『dsand c『eatea safer environment. This product is designed and tested to meet JEC 62368-1, the Standard for Safety of Information Technology Equipment. This also cove『sthe implementation of IEC 62368-1 based safety standards around the wo『Id,e.g. UL 60950-1. Retain and follow all product safety and operating instructions. Always『efe『to the documentation supplied with your equipment. Observe all warnings on the product and in the operating instructions Note: Read all safety information below and ope『atinginstructions before using FORMULER to avoid injury. WARNING: FAILURE TO FOLLOW THESE SAFETY INSTRUCTIONS COULD RESULT IN FIRE, ELECTRIC SHOCK OR OTHER INJURY OR DAMAGE. ELECTRICAL EQUIPMENT CAN BE H应ARDOUSIF MISUSED. OPERATION OF THIS PRODUCT, OR SIMILAR PRODUCTS, MUST ALWAYS BE SUPERVISED BY AN ADULT. DO NOT ALLOW CHILDREN ACCESS TO THE INTERIOR OF ANY ELECTRICAL PRODUCT AND DO NO PERMIT THEM TO HANDLE AND CABLES. SYMBOLS ON THE EQUIPMENT 宜This is a universal『ecyclingsymbol indicating that the battery cannot be disposed of in the t『 ash _ and must be recycled according to the『egulationsand/o『O咄nancesof the local commun灯 To reduce the『isk of personal injury, elect『ic shock, fire, o『damageto the equipment, observe the following precautions· Follow all cautions and Instructions marked on the equipment -Do not bend, drop, c『ush, puncture, incine『ate, or push objects into openings of FORMULER -Do not connect or disconnect any cables o『performmaintenance o『『econfigurationof this product du『ing an elect『ical sto『m -Do not use FORMULER in wet locations. In case FORMULER gets wet, unplug all cables and turn off befo『e cleaning, and allow it to dry thoroughly before turning it on again -Never turn on any equipment when there is evidence of fire, wate『,or structural damage -Place the product away from heat sou『ces. -Never force a connector into a port. Make sure the connecto『matchesthe port before inserting. -Always use a FORMULER approved powe『adapte『.Do not connect o顷sconnectthe AC Power Adapter with wet hands. The powe『adapte『is intended for indoor use only -Operate the AC adapte『in a ventilated a『ea -Do no make mechanical or electrical modifications to the equipment -Neve『attemptto repai『FORMULERyou『self.Do not attempt to open, disassemble the device You『un the risk of electric shock -Operate FORMULER in a place whe『ethe tempe『atu代is always between 5 and 30 deg『ees Celsius -Use this product only with approved equipment and/or accesso『ies POWER RA TING : 12 voe. 1.0A D缸laratlonRED FORMULER declare pa『la p『esenteque cet appareil sans fil『espectetoutes les exigences mate『ielles et autres dispositions pertinentes de la Directive 2014/53 / LIE. Une copie de la D的a『ationde Conformite peut知obteooedr出血玑au啦sde COBOPI..US (Cl INDEPENDENCIA, N2队IJERECHAAyB,2B013息OOID,SPAIN( Pour obteni『une assistance technique, des info『mationssu『la conformite aux『eglementationset un manuel d'utilisation, visitez le site https;//support. formuler ,tv INFORMATION SUR LA StCURITt Les produits FORMULER sont concus pou『fonctionneren toute securite lorsqu'ils sont installes et utilises confo『mementaux inst『uctionsdu produit et aux consignes de s的uritegenerales. Les di『ectivesincluses dans ce document expliquent les risques potentiels associes au fonctionnement de I'的uipementet fournissent des pratiques de secu『眙mportantesconcues pou『minimiserces『isques En suiYant attentiYement les informations contenues dans ce document, Yous pouYez Yous prot的erdes dange『Set C『ee『un enYironnement plus s山 Ce produit a ete concu et teste pour『epondrea la norme IEC 62368-1, norme su『la secu『ite des 的uipementsinfo『matiques.Cela couYre egalement la mise en teuYre des no『mesde securite basees sur la IEC 62368-1 dans le monde entier, pa『exemple.UL 60950-1. Conserve, et suiyez toutes les instructions de securite et d'utilisation du prodult. Consultez tou1ou『S a la documentation fournie aYec Yot『e equipement. Observe, tous les aYertissements sur le produit et dans les inst『uctionsd'utilisation. Remarque: lisez toutes les info『mationsde securite ci-dessous ainsi que les instructions d'utilisation aYant d'utilise『FORMULERafin d'eYite『Yousblesse『 …

Text truncated - open the document above for the full version.

Cover Letter(s)

ALOYS INC. Agent Authorization Company: ALOYS INC. Address: #6F, MARCUS Bldg., 4-5, Yanghyeon-ro405beon-gil, jungwon-gu, Seongnam-si, Gyeonggi-do, South Korea Product Name: Formuler Z11 Pro Trade Mark: FORMULER Model Number(s): Z11 Pro FCC ID: 2AV9UFZ104 We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2022-09-07 Name: martin Title: Manager Company: ALOYS INC.

Cover Letter(s)

ALOYS INC. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2022-09-07 Subject; Request for Confidentiality FCC ID: 2AV9UFZ104 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Software Security Requirements For U-NII Devices Operational Description In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: martin Title: Manager

External Photos

Page 1 of 6 FCC ID: 2AV9UFZ104 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 6 FCC ID: 2AV9UFZ104 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 6 FCC ID: 2AV9UFZ104 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 6 FCC ID: 2AV9UFZ104 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 6 FCC ID: 2AV9UFZ104 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Fig. 10 Page 6 of 6 FCC ID: 2AV9UFZ104 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 11

ID Label/Location Info

Page 1 of 1 FCC ID: 2AV9UFZ104 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L: 5.0cm x W: 5.0cm) Label Location Formuler Z11 Pro Model: Z11 Pro FCC ID: 2AV9UFZ104

Internal Photos

Page 1 of 5 FCC ID: 2AV9UFZ104 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 5 FCC ID: 2AV9UFZ104 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 WIFI ANT0 WIFI ANT1 BT Antenna Page 3 of 5 FCC ID: 2AV9UFZ104 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 5 FCC ID: 2AV9UFZ104 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 5 FCC ID: 2AV9UFZ104 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9

Test Report

Page 1 of 23 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix B RF Test Data for BT LE (Conducted Measurement) Product Name: Formuler Z11 Pro Test Model: Z11 Pro Environmental Conditions Temperature: 23.8°C Relative Humidity: 52.2% ATM Pressure: 100.0 kPa Test Engineer: Ling Zhu Supervised by: Li Huan Page 2 of 23 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity B.1 -6dB Bandwidth Condition Mode Frequency (MHz) Antenna -6 dB Bandwidth (MHz) Limit -6 dB Bandwidth (MHz) Verdict NVNT BLE 2402 Ant 0.700 >=0.5 Pass NVNT BLE 2440 Ant 0.705 >=0.5 Pass NVNT BLE 2480 Ant 0.707 >=0.5 Pass Page 3 of 23 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -6dB Bandwidth NVNT BLE 2402MHz Ant -6dB Bandwidth NVNT BLE 2440MHz Ant Page 4 of 23 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT BLE 2480MHz Ant Page 5 of 23 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity B.2 Maximum Peak Conducted Output Power Condition Mode Frequency (MHz) Antenna Conducted Power (dBm) Limit (dBm) Verdict NVNT BLE 2402 Ant -0.69 30 Pass NVNT BLE 2440 Ant -0.96 30 Pass NVNT BLE 2480 Ant -1.11 30 Pass Page 6 of 23 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Power NVNT BLE 2402MHz Ant Power NVNT BLE 2440MHz Ant Page 7 of 23 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Power NVNT BLE 2480MHz Ant Page 8 of 23 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity B.3 Maximum Power Spectral Density Level Condition Mode Frequency (MHz) Antenna Conducted PSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNT BLE 2402 Ant -17.33 8 Pass NVNT BLE 2440 Ant -16.1 8 Pass NVNT BLE 2480 Ant -16.23 8 Pass Page 9 of 23 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs PSD NVNT BLE 2402MHz Ant PSD NVNT BLE 2440MHz Ant Page 10 of 23 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity PSD NVNT BLE 2480MHz Ant Page 11 of 23 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity B.4 Band Edge Condition Mode Frequency (MHz) Antenna Max Value (dBc) Limit (dBc) Verdict NVNT BLE 2402 Ant -54.86 -20 Pass NVNT BLE 2480 Ant -55.37 -20 Pass Page 12 of 23 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Band Edge NVNT BLE 2402MHz Ant Ref Band Edge NVNT BLE 2402MHz Ant Emission Page 13 of 23 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check au…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 108 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix C RF Test Data for 2.4G WIFI (Conducted Measurement) Product Name: Formuler Z11 Pro Test Model: Z11 Pro Environmental Conditions Temperature: 23.8°C Relative Humidity: 52.2% ATM Pressure: 100.0 kPa Test Engineer: Ling Zhu Supervised by: Li Huan Page 2 of 108 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity C.1 -6dB Bandwidth Condition Mode Frequency (MHz) Antenna -6 dB Bandwidth (MHz) Limit -6 dB Bandwidth (MHz) Verdict NVNT b 2412 Ant0 9.665 >=0.5 Pass NVNT b 2437 Ant0 9.669 >=0.5 Pass NVNT b 2462 Ant0 9.995 >=0.5 Pass NVNT g 2412 Ant0 16.377 >=0.5 Pass NVNT g 2437 Ant0 16.327 >=0.5 Pass NVNT g 2462 Ant0 16.322 >=0.5 Pass NVNT n20 2412 Ant0 15.275 >=0.5 Pass NVNT n20 2437 Ant0 15.869 >=0.5 Pass NVNT n20 2462 Ant0 16.905 >=0.5 Pass NVNT n40 2422 Ant0 36.312 >=0.5 Pass NVNT n40 2437 Ant0 34.232 >=0.5 Pass NVNT n40 2452 Ant0 36.31 >=0.5 Pass Page 3 of 108 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -6dB Bandwidth NVNT b 2412MHz Ant0 -6dB Bandwidth NVNT b 2437MHz Ant0 Page 4 of 108 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT b 2462MHz Ant0 -6dB Bandwidth NVNT g 2412MHz Ant0 Page 5 of 108 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT g 2437MHz Ant0 -6dB Bandwidth NVNT g 2462MHz Ant0 Page 6 of 108 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT n20 2412MHz Ant0 -6dB Bandwidth NVNT n20 2437MHz Ant0 Page 7 of 108 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT n20 2462MHz Ant0 -6dB Bandwidth NVNT n40 2422MHz Ant0 Page 8 of 108 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT n40 2437MHz Ant0 -6dB Bandwidth NVNT n40 2452MHz Ant0 Page 9 of 108 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Condition Mode Frequency (MHz) Antenna -6 dB Bandwidth (MHz) Limit -6 dB Bandwidth (MHz) Verdict NVNT b 2412 Ant1 9.852 >=0.5 Pass NVNT b 2437 Ant1 8.618 >=0.5 Pass NVNT b 2462 Ant1 9.312 >=0.5 Pass NVNT g 2412 Ant1 16.306 >=0.5 Pass NVNT g 2437 Ant1 15.295 >=0.5 Pass NVNT g 2462 Ant1 14.996 >=0.5 Pass NVNT n20 2412 Ant1 17.591 >=0.5 Pass NVNT n20 2437 Ant1 15.16 >=0.5 Pass NVNT n20 2462 Ant1 16.516 >=0.5 Pass NVNT n40 2422 Ant1 29.407 >=0.5 Pass NVNT n40 2437 Ant1 28.116 >=0.5 Pass NVNT n40 2452 Ant1 35.689 >=0.5 Pass Page 10 of 108 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -6dB Bandwidth NVNT b 2412MHz Ant1 -6dB Bandwidth NVNT b 2437MHz Ant1 Page 11 of 108 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT b 2462MHz Ant1 -6dB Bandwidth NVNT g 2412MHz Ant1 Page 12 of 108 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shen…

Text truncated - open the document above for the full version.

Test Report

Page 56 of 108 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Tx. Spurious NVNT n20 2412MHz Ant0 Ref Tx. Spurious NVNT n20 2412MHz Ant0 Emission Page 57 of 108 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Tx. Spurious NVNT n20 2437MHz Ant0 Ref Tx. Spurious NVNT n20 2437MHz Ant0 Emission Page 58 of 108 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Tx. Spurious NVNT n20 2462MHz Ant0 Ref Tx. Spurious NVNT n20 2462MHz Ant0 Emission Page 59 of 108 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Tx. Spurious NVNT n40 2422MHz Ant0 Ref Tx. Spurious NVNT n40 2422MHz Ant0 Emission Page 60 of 108 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Tx. Spurious NVNT n40 2437MHz Ant0 Ref Tx. Spurious NVNT n40 2437MHz Ant0 Emission Page 61 of 108 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Tx. Spurious NVNT n40 2452MHz Ant0 Ref Tx. Spurious NVNT n40 2452MHz Ant0 Emission Page 62 of 108 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Condition Mode Frequency (MHz) Antenna Max Value (dBc) Limit (dBc) Verdict NVNT b 2412 Ant1 -50.27 -20 Pass NVNT b 2437 Ant1 -50.11 -20 Pass NVNT b 2462 Ant1 -50.26 -20 Pass NVNT g 2412 Ant1 -45.84 -20 Pass NVNT g 2437 Ant1 -46.47 -20 Pass NVNT g 2462 Ant1 -43.34 -20 Pass NVNT n20 2412 Ant1 -46.57 -20 Pass NVNT n20 2437 Ant1 -45.94 -20 Pass NVNT n20 2462 Ant1 -46.36 -20 Pass NVNT n40 2422 Ant1 -43.59 -20 Pass NVNT n40 2437 Ant1 -43.01 -20 Pass NVNT n40 2452 Ant1 -42.2 -20 Pass Page 63 of 108 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Tx. Spurious NVNT b 2412MHz Ant1 Ref Tx. Spurious NVNT b 2412MHz Ant1 Emission Page 64 of 108 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Tx. Spurious NVNT b 2437MHz Ant1 Ref Tx. Spurious NVNT b 2437MHz Ant1 Emission Page 65 of 108 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Tx. Spurious NVNT b 2462MHz Ant1 Ref Tx. Spurious NVNT b 2462MHz Ant1 Emission Page 66 of 108 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Tx. Spurious NVNT g 2412MHz Ant1 Ref Tx. Spurious NVNT g 2412MHz Ant1 Emission Page 67 of 108 FCC ID: 2AV9UFZ104 Report No.: LCSA072022057EC Shenzhen LCS Compliance Testing Labor…

Text truncated - open the document above for the full version.

Contact Information

Applicant

martin martin(Manager)
[email protected]+82 70 8680 5015Fax: +82 31 709 0262

Technical Contact

ALOYS INC.
[email protected]

South Korea

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz62.80 mW
Confidentiality
Long Term
Grant Notes
Output power listed is maximum combined conducted power. This device contains 20 and 40 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Other Applications from ALOYS INC.

2AV9UGH104

Formuler Z mini

Jan 28, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Android Media Player - FCC ID 2AV9UFZ105 - ALOYS INC.
2AV9UFZ105

Android Media Player

Aug 03, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Formuler Z10 Pro - FCC ID 2AV9UZ10PRO - ALOYS INC.
2AV9UZ10PRO

Formuler Z10 Pro

Aug 02, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Formuler Z10 Pro Max - FCC ID 2AV9UZ10PROMAX - ALOYS INC.
2AV9UZ10PROMAX

Formuler Z10 Pro Max

Jul 01, 2021

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Formuler CC - FCC ID 2AV9UCC - ALOYS INC.
2AV9UCC

Formuler CC

Nov 22, 2020

Equipment Class

DTS - Digital Transmission System