
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Quick Setup Guide & Safety Information https://formuler.tv/giveaway Go to the link below for #GIVEAWAY rule information Enter the giveaway for a chance to win a prize. Thank you for your purchase. 1 Connect your FORMULER to your TV with an HDMI cable. Connect your FORMULER to power using the power cord. Turn on your TV and switch to the correct HDMI input. 1 2 3 Set-up your FORMULER and connect to your local network. 4 5 Installation Guide EN Wired NetworkWireless Network Install your favorite apps to enjoy streaming contents * . 2 TV Cable Media Receiver Remote Control Extender Remote Control 2x Batteries Power Adapter What’s in the Box? EN 3 Verbinden Sie Ihre FORMULER und den Fernseher mit einem HDMI Kabel. Schließen Sie Ihre FORMULER über das Netzkabel an die Stromversorgung an. Schalten Sie Ihr Fernsehgerät ein und wechseln Sie zum richtigen HDMI-Eingang. 1 2 3 Richten Sie Ihre FORMULER ein und stellen Sie eine Verbindung zum lokalen Netzwerk her. 4 Installieren Sie Ihre gewünschten Apps um die Streaming – Angebote genießen zu können * . 5 Installationsanleitung DE Kabelgebundenes NetzwerkDrahtloses Netzwerk 4 TV-Kabel Medienempfänger Fernbedienung Extender Fernbedienung 2 x Batterien Netzteil Was ist in der Box? DE 5 RED Declaration FORMULER hereby declares that this wireless device complies with all material requirements and other relevant provisions of the 2014/53/EU Directive. A copy of the Declaration of Conformity may be obtained directly from COBOPLUS [Thomas Edison 4, 28521 Madrid, Spain] For technical support, regulatory compliance information, and user guide, visit https://support.formuler.tv SAFETY INFORMATION FORMULER products are designed to operate safely when installed and used according to the product instructions and general safety practices. The guidelines included in this document explain the potential risks associated with equipment operation and provide important safety practices designed to minimize these risks. By carefully following the information contained in this document, you can protect yourself from hazards and create a safer environment. This product is designed and tested to meet IEC 62368-1, the Standard for Safety of Information Technology Equipment. This also covers the implementation of IEC 62368-1 based safety standards around the world, e.g. UL 60950-1. Retain and follow all product safety and operating instructions. Always refer to the documentation supplied with your equipment. Observe all warnings on the product and in the operating instructions. Note: Read all safety information below and operating instructions before using FORMULER to avoid injury. WARNING: FAILURE TO FOLLOW THESE SAFETY INSTRUCTIONS COULD RESULT IN FIRE, ELECTRIC SHOCK OR OTHER INJURY OR DAMAGE. ELECTRICAL EQUIPMENT CAN BE HAZARDOUS IF MISUSED. OPERATION OF THIS PRODUCT, OR SIMILAR PRODUCTS, MUST ALWAYS BE SUPERVISED BY AN ADULT. DO NOT ALLOW CHILDREN ACCESS TO THE INTERIOR OF ANY ELECTRICAL PRODUCT AND DO NO PERMIT THEM TO HANDLE AND CABLES. 6 SYMBOLS ON THE EQUIPMENT This is a universal recycling symbol indicating that the battery cannot be disposed of in the trash and must be recycled according to the regulations and/or ordinances of the local community. To reduce the risk of personal injury, electric shock, fire, or damage to the equipment, observe the following precautions: Follow all cautions and instruct ions marked on the equipment POWER RATING : 12 VDC, 1.0A - Do not bend, drop, crush, puncture, incinerate, or push objects into openings of FORMULER. - Do not connect or disconnect any cables or perform maintenance or reconfiguration of this product during an electrical storm. - Do not use FORMULER in wet locations. In case FORMULER gets wet, unplug all cables and turn off before cleaning, and allow it to dry thoroughly before turning it on again. - Never turn on any equipment when there is evidence of fire, water, or structural damage. - Place the product away from heat sources. - Never force a connector into a port. Make sure the connector matches the port before inserting. - Always use a FORMULER approved power adapter. Do not connect or disconnect the AC Power Adapter with wet hands. The power adapter is intended for indoor use only. - Operate the AC adapter in a ventilated area. - Do no make mechanical or electrical modifications to the equipment. - Never attempt to repair FORMULER yourself. Do not attempt to open, disassemble the device. You run the risk of electric shock. - Operate FORMULER in a place where the temperature is always between 5 and 30 degrees Celsius. - Use this product only with approved equipment and/or accessories. 7 Déclaration RED FORMULER déclare par la présente que cet appareil sans fil respecte toutes les exigences matérielles et autres dispositions pertinentes de la Directive 2014/53 / UE. Une copie de la Déclaration de Conformité peut être obtenue directement auprès de COBOPLUS [Thomas Edison 4, 28521 Madrid, Espagne] Pour obtenir une assistance technique, des informations sur la conformité aux réglementations et un manuel d’utilisation, visitez le site https://support.formuler.tv INFORMATION SUR LA SÉCURITÉ Les produits FORMULER sont conçus pour fonctionner en toute sécurité lorsqu'ils sont installés et utilisés conformément aux instructions du produit et aux consignes de sécurité générales. Les directives incluses dans ce document expliquent les risques potentiels associés au fonctionnement de l'équipement et fournissent des pratiques de sécurité importantes conçues pour minimiser ces risques. En suivant attentivement les informations contenues dans ce document, vous pouvez vous protéger des dangers et créer un environnement plus sûr. Ce produit a été conçu et testé pour répondre à la norme IEC 62368-1, norme sur la sécurité des équipements informatiques. Cela couvre également la mise en œuvre des normes de sécurité basées sur la IEC 62368-1 dans le monde entier, par exemple. UL 60950-1. Conservez et suivez toutes les instructions d…
Text truncated - open the document above for the full version.
ALOYS INC. FCC Software Configuration Control Declaration Date: June 28, 2021 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Attn: OET Dept. Product Name: Formuler Z10 Pro Max Model Number: Z10 Pro Max Regarding FCC Country Code Selection guidelines identified in KDB 594280 D02 U-NII Device Security v01r03. “All applications for equipment authorization for transmitters that can have radio parameters, or other technical parameters, reported to the Commission set by software must have an attestation indicating that no third party will have software, or configuration control, to program the device out of compliance of the technical rules under which it has been certified.” We declare that no third party will have software, or configuration control, to program the device out of compliance of the technical rules under which it has been certified. Name: martin Date: 2021-06-28 Title: Manager Signature of applicant FCC Software Configuration Control Declaration Rev1.1
ALOYS INS. Agent Authorization Company: ALOYS INS. Address: 6F,Marcus Bldg. ,4-5,Yanghyeon-ro 405beon-gil, Jungwon- gu ,Seongnam-si ,Gyeonggi-do, South Korea Product Name: Formuler Z10 Pro Max Trade Mark: FORMULER Model Number: Z10 Pro Max Product Description: Formuler Z10 Pro Max with BT, BLE, 2.4G WiFi, 5.2G WiFi and 5.8G WiFi. We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2021-06-26 Name: KWON CHUNG Title: Manager Company: ALOYS INS.
ALOYS INC. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2021-06-28 Subject; Request for Confidentiality FCC ID: 2AV9UZ10PROMAX To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Software Security Requirements For U-NII Devices Operational Description In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: martin Title: Manager
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX 1. EXTERIOR PHOTOGRAPHS Fig.1 Fig.2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Fig.3 Fig.4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Fig.5 Fig.6 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Fig.7 Fig.8 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Fig.9
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 1 Label and Location Size: L5.0cm*W5.0cm Label Location Formuler Z10 Pro Max Model No.: Z10 Pro Max FCC ID: 2AV9UZ10PROMAX
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX 1. INTERIOR PHOTOGRAPHS Fig.1 Fig.2 BT ANT SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Fig.3 Fig.4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Fig.5 Fig.6 WiFi ANT 0 WiFi ANT 1 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Fig.7 Fig.8 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Fig.9 Fig.10 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Fig.11
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 13 Maximum Permissible Exposure Report 1. Product Information FCC ID: 2AV9UZ10PROMAX Product name Formuler Z10 Pro Max Test Model Z10 Pro Max Power supply For AC Adapter: TEKA‐TB120100US Input:100‐240V~, 50/60Hz, 0.35A MAX Output: 12.0V 1.0A Operation frequency 2402MHz‐2480MHz 2412MHz‐2462MHz 5180MHz‐5240MHz 5745MHz‐5825MHz Antenna Type ANT0: Internal Antenna ANT1: InternalAntenna Antenna Gain 2.0dBi(Max) Hardware version EZ205 Software version 1.4.90‐r26061 Channel Number 79 channels for BluetoothV4.1 (BDR/EDR) 40 channels for Bluetooth V4.1 (BT LE) 11 Channels for 20MHz bandwidth (2412~2462MHz) 7 Channels for 40MHz bandwidth (2422~2452MHz) 4 channels for 20MHz bandwidth (5180‐5240MHz) 2 channels for 40MHz bandwidth (5190~5230MHz) 1 channels for 80MHz bandwidth (5210MHz) 5 channels for 20MHz bandwidth(5745‐5825MHz) 2 channels for 40MHz bandwidth(5755~5795MHz) 1 channels for 80MHz bandwidth(5775MHz) Channel Spacing 5MHz Exposure category General population/uncontrolled environment EUT Type Production Unit Device Type Mobile Devices 2. Evaluation Method Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile device whereby a distance of 0.2m normally can be maintained between the user and the device, and below RF Permissible Exposure limit shall comply with. In accordance with KDB447498D01 for Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the calculated/estimated, numerically modelled or measured field strengths or power density, is ≤ 1.0. The MPE ratio of each antenna is determined at the minimum test separation distance required by the operating configurations and exposure conditions of the host device, according to the ratio of field strengths or power density to MPE limit, at the test frequency. Either the maximum peak or spatially averaged results from measurements or numerical simulations may be used to determine the MPE ratios. Spatial averaging does not apply when MPE is estimated using simple calculations based on far‐field plane‐wave equivalent conditions. The antenna installation and operating requirements for the host device must meet the minimum test separation distances required by all antennas, in both standalone and simultaneous transmission operations, to satisfy compliance. SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 13 3. Limit 3. 1 Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General 1 RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: Mobile Devices 3. 2 Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100) * (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100) * (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequency in MHz *=Plane‐wave equivalent power density 4. MPE Calculation Method Predication of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97‐01 S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna 5. Antenna Information ES‐D4 can only use antennas certificated as follows provided by manufacturer; Antenna type and antenna number Operate frequency band Maximum antenna gain Notes Internal Antenna 0 Internal Antenna 1 2412MHz‐2462MHz 5180MHz‐5240MHz 5745MHz‐5825MHz 2 dBi WiFi Antenna Internal Antenna 2402MHz‐2480MHz 2dBiBT/WiFi Antenna SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 13 6. Conducted Power [BT Max Conducted Power] Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) GFSK 0 2402 1.336 39 2441 1.771 78 2480 1.794 π/4DQPSK 0 2402 1.280 39 2441 1.712 78 2480 1.757 8DPSK 0 2402 1.334 19 2441 1.763 39 2480 1.793 [BLE Max Conducted Power] Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) BT LE 0 2402 ‐2.075 19 2440 ‐1.656 39 2480 ‐1.632 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 4 of 13 [2.4GWIFI Max Conducted Power] Mode Channel Frequency (MHz) ANT 0 Max Conducted Power(dBm) ANT 1 Max Conducted Power(dBm) 11B 1 2412 12.97 12.91 6 2437 13.15 12.…
Text truncated - open the document above for the full version.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AV9UZ10PROMAX Report No.: LCS210513065AED Page 1 of 83 Appendix D RF Test Data for 5.2G WLAN (Conducted Measurement) Product Name: Formuler Z10 Pro Max Trade Mark: FORMULER Test Model: Z10 Pro Max Environmental Conditions Temperature: 23.7 C Relative Humidity: 51.6% ATM Pressure: 100.0 kPa Test Engineer: Jay Li Supervised by: Li Huan D.1 Duty Cycle ANT0 Test Mode Test Frequency (MHz) Duty Cycle (%) 10log(1/x) Factor (dB) 1/B Minimum VBW(KHz) 11A 5200 100 0.00 0.01 11N20 SISO 5200 100 0.00 0.01 11N40 SISO 5190 100 0.00 0.01 11AC20 SISO 5200 100 0.00 0.01 11AC40 SISO 5190 100 0.00 0.01 11AC80 SISO 5210 100 0.00 0.01 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AED Page 2 of 83 On Time and Duty Cycle IEEE 802.11a IEEE 802.11n HT20 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AED Page 3 of 83 IEEE 802.11n HT40 IEEE 802.11AC20 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AED Page 4 of 83 IEEE 802.11 AC40 IEEE 802.11AC80 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AED Page 5 of 83 ANT1 Test Mode Test Frequency (MHz) Duty Cycle (%) 10log(1/x) Factor (dB) 1/B Minimum VBW(KHz) 11A 5200 100 0.00 0.01 11N20 SISO 5200 100 0.00 0.01 11N40 SISO 5190 100 0.00 0.01 11AC20 SISO 5200 100 0.00 0.01 11AC40 SISO 5190 100 0.00 0.01 11AC80 SISO 5210 100 0.00 0.01 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AED Page 6 of 83 On Time and Duty Cycle IEEE 802.11a IEEE 802.11n HT20 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AED Page 7 of 83 IEEE 802.11n HT40 IEEE 802.11AC20 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AED Page 8 of 83 IEEE 802.11 AC40 IEEE 802.11AC80 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AED Page 9 of 83 D.2 Maximum Conduct Output Power ANT0 Test Mode Channel Frequency (MHz) AVG Conducted Power (dBm) Duty Cycle Factor( dB) Report Conducted Power(dBm) Limit (dBm) Verdict 11A 36 5180 13.59 0 13.59 24 Pass 40 5200 13.73 0 13.73 Pass 48 5240 13.06 0 13.06 Pass 11N20 SISO 36 5180 13.11 0 13.11 24 Pass 40 5200 13.06 0 13.06 Pass 48 5240 12.46 0 12.46 Pass 11N40 SISO 38 5190 12.57 0 12.57 24 Pass 46 5230 12.69 0 12.69 Pass 11AC20 SISO 36 5180 13.55 0 13.55 24 Pass 40 5200 13.52 0 13.52 Pass 48 5240 12.97 0 12.97 Pass 11AC40 SISO 38 5190 13.43 0 13.43 24 Pass 46 5230 13.32 0 13.32 Pass 11AC80 SISO 42 5210 13.5 0 13.5 24 Pass Maximum Conducted Output Power IEEE 802.11a / Channel 36 / 5180MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AED Page 10 of 83 IEEE 802.11a / Channel 40 / 5200MHz IEEE 802.11a / Channel 48 / 5240MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AED Page 11 of 83 Maximum Conducted Output Power IEEE 802.11n20 / Channel 36 / 5180MHz IEEE 802.11n20 / Channel 40 / 5200MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AED Page 12 of 83 IEEE 802.11n20 / Channel 48 / 5240MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AED Page 13 of 83 Maximum Conducted Output Power IEEE 802.11n40 / Channel 38 / 5190MHz IEEE 802.11n40 / Channel 46 / 5230MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AED Page 14 of 83 IEEE 802.11ac20 / Channel 36 / 5180MHz IEEE 802.11ac20 / Channel 40 / 5200MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AED Page 15 of 83 IEEE 802.11ac20 / Channel 48 / 5240MHz IEEE 802.11ac40 / Channel 38 / 5190MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AED Page 16 of 83 IEEE 802.11ac40 / Channel 46 / 5230MHz IEEE 802.11ac80 / Channel 42 / 5210MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AED Page 17 of 83 ANT1 Test Mode Channel Frequency (MHz) AVG Conducted Power (dBm) Duty Cycle Factor( dB) Report Conducted Power(dBm) Limit (dBm) Verdict 11A 36 5180 11.46 0 11.46 24 Pass 40 5200 11.4 0 11.4 Pass 48 5240 11.56 0 11.56 Pass 11N20 SISO 36 5180 13.54 0 13.54 24 Pass 40 5200 13.35 0 13.35 Pass 48 5240 12.92 0 12.92 Pass 11N40 SISO 38 5190 11.14 0 11.14 24 Pass 46 5230 11.98 0 11.98 Pass 11AC20 SISO 36 5180 11.08 0 11.08 24 Pass 40 5200 11.19 0 11.19 Pass 48 5240 12.03 0 12.03 Pass 11AC40 SISO 38 5190 11.17 0 11.17 24 Pass 46 5230 11.71 0 11.71 Pass 11AC80 SISO 42 5210 9.91 0 9.91 24 Pass Maximum Conducted Output Power IEEE 802.11a / Channel 36 / 5180MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AED Page 18 of 83 IEEE 802.11a / Channel 40 / 5200MHz IEEE 802.11a / Channel 48 / 5240MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AED Page 19 of 83 Maximum Conducted Output Power IEEE 802.11n20 / Channel 36 / 5180MHz IEEE 802.11n20 / Channel 40 / 5200MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AED Page 20 of 83 IEEE 802.11n20 / Channel 48 / 5240MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AED Page 21 of 83 Maximum Conducted Output Power IEEE 802.11n40 / Channel 38 / 5190MHz IEEE 802.11n40 / Channel 46 / 5230MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AED Page 22 of 83 IEEE 802.11ac20 / Channel 36 / 5180MHz IEEE 802.11ac20 / Channel 40 / 5200MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AED Page 23 of 83 IEEE 802.11ac20 / Ch…
Text truncated - open the document above for the full version.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AEE Page 1 of 88 Appendix E RF Test Data for 5.8G WLAN (Conducted Measurement) Product Name: Formuler Z10 Pro Max Trade Mark: FORMULER Test Model: Z10 Pro Max Environmental Conditions Temperature: 23.7 C Relative Humidity: 51.6% ATM Pressure: 100.0 kPa Test Engineer: Jay Li Supervised by: Li Huan E.1 Duty Cycle ANT0 Test Mode Test Frequency (MHz) Duty Cycle (%) 10log(1/x) Factor (dB) 1/B Minimum VBW(KHz) 11A 5785 100 0.00 0.01 11N20 SISO 5785 100 0.00 0.01 11N40 SISO 5755 100 0.00 0.01 11AC20 SISO 5785 100 0.00 0.01 11AC40 SISO 5755 100 0.00 0.01 11AC80 SISO 5775 100 0.00 0.01 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AEE Page 2 of 88 On Time and Duty Cycle IEEE 802.11a IEEE 802.11n HT20 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AEE Page 3 of 88 IEEE 802.11n HT40 IEEE 802.11AC20 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AEE Page 4 of 88 IEEE 802.11AC40 IEEE 802.11AC80 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AEE Page 5 of 88 ANT1 Test Mode Test Frequency (MHz) Duty Cycle (%) 10log(1/x) Factor (dB) 1/B Minimum VBW(KHz) 11A 5785 100 0.00 0.01 11N20 SISO 5785 100 0.00 0.01 11N40 SISO 5755 100 0.00 0.01 11AC20 SISO 5785 100 0.00 0.01 11AC40 SISO 5755 100 0.00 0.01 11AC80 SISO 5775 100 0.00 0.01 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AEE Page 6 of 88 On Time and Duty Cycle IEEE 802.11a IEEE 802.11n HT20 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AEE Page 7 of 88 IEEE 802.11n HT40 IEEE 802.11AC20 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AEE Page 8 of 88 IEEE 802.11AC40 IEEE 802.11AC80 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AEE Page 9 of 88 E.2 Maximum Conduct Output Power ANT0 Test Mode Channe l Frequency (MHz) AVG Conducted Power (dBm) Duty Cycle Factor(dB) Report Conducted Power(dBm) Limit (dBm) Verdict 11A 149 5745 11.54 0 11.54 30 Pass 157 5785 13.45 0 13.45 Pass 165 5825 14.59 0 14.59 Pass 11N20 SISO 149 5745 11.04 0 11.04 30 Pass 157 5785 12.85 0 12.85 Pass 165 5825 14.41 0 14.41 Pass 11N40 SISO 151 5755 11.65 0 11.65 30 Pass 159 5795 13.36 0 13.36 Pass 11AC20 SISO 149 5745 13.55 0 13.55 30 Pass 157 5785 13.52 0 13.52 Pass 165 5825 12.97 0 12.97 Pass 11AC40 SISO 151 5755 13.43 0 13.43 30 Pass 159 5795 13.32 0 13.32 Pass 11AC80 SISO 155 5775 9.96 0 9.96 30 Pass Maximum Conducted Output Power IEEE 802.11a / Channel 149 / 5745MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AEE Page 10 of 88 IEEE 802.11a / Channel 157 / 5785MHz IEEE 802.11a / Channel 165 / 5825MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AEE Page 11 of 88 Maximum Conducted Output Power IEEE 802.11n20 / Channel 149 / 5745MHz IEEE 802.11n20 / Channel 157 / 5785MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AEE Page 12 of 88 IEEE 802.11n20 / Channel 165 / 5825MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AEE Page 13 of 88 Maximum Conducted Output Power IEEE 802.11n40 / Channel 151 / 5755MHz IEEE 802.11n40 / Channel 159 / 5795MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AEE Page 14 of 88 IEEE 802.11ac20 / Channel 149 / 5745MHz IEEE 802.11ac20 / Channel 157 / 5785MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AEE Page 15 of 88 IEEE 802.11ac20 / Channel 165/ 5825MHz IEEE 802.11ac40 / Channel 151 / 5755MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AEE Page 16 of 88 IEEE 802.11ac40 / Channel 159 / 5795MHz IEEE 802.11ac80 / Channel 155 / 5775MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AEE Page 17 of 88 ANT1 Test Mode Channe l Frequency (MHz) AVG Conducted Power (dBm) Duty Cycle Factor(dB) Report Conducted Power(dBm) Limit (dBm) Verdict 11A 149 5745 11.82 0 11.82 30 Pass 157 5785 13.7 0 13.84 Pass 165 5825 11.77 0 11.77 Pass 11N20 SISO 149 5745 11.47 0 11.47 30 Pass 157 5785 12.06 0 12.06 Pass 165 5825 11.72 0 11.72 Pass 11N40 SISO 151 5755 11.44 0 11.44 30 Pass 159 5795 11.76 0 11.76 Pass 11AC20 SISO 149 5745 11.08 0 11.08 30 Pass 157 5785 11.19 0 11.19 Pass 165 5825 12.03 0 12.03 Pass 11AC40 SISO 151 5755 11.17 0 11.17 30 Pass 159 5795 11.71 0 11.71 Pass 11AC80 SISO 155 5775 12.94 0 12.94 30 Pass Maximum Conducted Output Power IEEE 802.11a / Channel 149 / 5745MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AEE Page 18 of 88 IEEE 802.11a / Channel 157 / 5785MHz IEEE 802.11a / Channel 165 / 5825MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AEE Page 19 of 88 Maximum Conducted Output Power IEEE 802.11n20 / Channel 149 / 5745MHz IEEE 802.11n20 / Channel 157 / 5785MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AEE Page 20 of 88 IEEE 802.11n20 / Channel 165 / 5825MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AEE Page 21 of 88 Maximum Conducted Output Power IEEE 802.11n40 / Channel 151 / 5755MHz IEEE 802.11n40 / Channel 159 / 5795MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AEE Page 22 of 88 IEEE 802.11ac20 / Channel 149 / 5745MHz IEEE 802.11ac20 / Channel 157 / 5785MHz SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No…
Text truncated - open the document above for the full version.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS210513065AED This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 42 FCC TEST REPORT For ALOYS INC. Formuler Z10 Pro Max Test Model: Z10 Pro Max Prepared for : ALOYS INC. Address : #6F ,MARCUS Bldg.,4-5, Yanghyeon-ro405beon-gil,jungwon-gu, Seongnam-si, Gyeonggi-do, South Korea Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : May 17, 2021 Number of tested samples : 2 Serial number : 210513065A-1(Engineer sample), 210513065A-2(Normal sample) Date of Test : May 17, 2021 ~ June 05, 2021 Date of Report : June 09, 2021 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AV9UZ10PROMAX Report No.: LCS2…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15E | 5.75 GHz - 5.83 GHz | 42.50 mW |
Formuler Z mini
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Android Media Player
Equipment Class
DTS - Digital Transmission System
Android Media Player
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Formuler Z10 Pro
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Formuler CC
Equipment Class
DTS - Digital Transmission System