FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Tatwah SA/
  3. 2AWJD-IT001

2AWJD-IT001TWHBC01 IT001 tag

Tatwah SA
TWHBC01 IT001 tag - FCC ID 2AWJD-IT001 - Tatwah SA
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jun 28, 2020
Application Purpose
Original Equipment
Date of Application
Jun 27, 2020
Equipment Note
TWHBC01 IT001 tag
Frequency Range
2402.00000000 - 2480.00000000
Company
Tatwah SA
Country
Switzerland

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Beacon IT001 (TWHBC01 module) User Manual IT001 is a broadcast protocol based on the bluetooth BLE protocol. It is usually installed in a suitable location, and it will broadcast continuously or periodically to its surrounding environment The IT001 beacon allows to create Bluetooth® Low Energy (Bluetooth LE) 5.0 solutions. Besides basic Bluetooth LE advertising functionality via radio transmission, the TWHBC01 beacon allows additional functionality thanks to the add-on hardware components: a green and a red LED, a push button and an accelerometer with built-in thermometer. Depending on the casing not all hardware components may be present or can be used. The accelerometer can be configured for detection of specific events. Currently the following events are supported: free fall, single tap, double tap, activity/movement and flip-flop. There are two aspects concerning the TWHBC01 beacon firmware. On the one hand there is a firmware implemented as a release HEX file with functionality as described in this document. A major objective in the implementation is low current consumption hence long battery lifetime. There are many parameters that affect the behavior of the firmware. The release firmware has default values for these parameters. Firmware Functionality TWHBC01 beacon can be in five modes: • Transport & Warehousing • Configuration • Operational Active • Operational Active_Alarm • Operational Passive_Alarm By Operational mode we refer to the actual mode that is configured and can be either Operational Active, Operational Active_Alarm or Operational Passive_Alarm. Transport & Warehousing mode As its name suggests, this mode is meant for the beacon to be silent for a long period and only to be woken up when needed. Therefore this mode has no advertising broadcast. Wake-up can occur on possible events: • Accelerometer event • Short press on push button On wakeup the beacon goes to the configured Operational mode. Operational Active mode In this mode the beacon does an undirected advertising (broadcast) with frame content defined by the configuration parameters. The broadcast can be either connectable or non-connectable. When it is connectable, the beacon reverts to Configuration mode on connection by a (central) client, where a new configuration can be uploaded. The connectable option should only be used for testing purposes. Based on configuration settings, the push button and/or accelerometer can be enabled. On occurrence of the alarm state, which is triggered by either a long press of the push button or on accelerometer event, the beacon stops advertising for a given period (alarm duration timer), after which it restarts normal broadcast. Operational Active_Alarm mode This mode is similar to the Operational Active mode, except that during the alarm state the beacon broadcasts an alarm frame instead of being silent. On occurrence of the alarm state, the beacon starts an undirected alarm broadcast for a given period (alarm duration timer), after which it restarts normal broadcast. Operational Passive_Alarm mode This mode is similar to the Operational Active_Alarm mode, except that the beacon is silent until an event occurs. Configuration mode This mode is used for testing and configuration. In this mode the beacon does undirected connectable advertising. This mode is entered when the Operational mode is connectable and a (central) client connects. When connected the (central) client can interact with the Configuration Service in the beacon. The only way to leave the Configuration mode is by uploading and activating a valid TLV file. Alarm broadcast The broadcast in the alarm state of modes Operational Active_Alarm and Operational Passive_Alarm consists of just one frame type and can be either connectable or non-connectable1. Behavior on reset On reset the beacon checks whether valid TLV configuration file is present in flash. If so its configuration values are used. If no TLV file is present or is erroneous, the beacon uses the default configuration. To show which of these is the case the beacon flicks LEDs just after startup: • Twice green LED when TLV content is used. • Green LED followed by red LED when TLV configuration is not supported. • Twice red LED when TLV configuration is supported but TLV data are erroneous. Product specification Product usage scenario: Asset tracking and location in an industrial environment. People flow management, secure access control, People monitoring in certain areas. Product installation method The beacon can be stuck onto objects with a strong adhesive surface on it's backside. For removable versions, the Beacon can be supplied with an extra strong Velcro surface FCC WARNING This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation betwee…

Text truncated - open the document above for the full version.

Attestation Statements

Applicant: Tatwah SA   .  Discrepancy Declaration  Product name:TWHBC01 IT001 tag FCC ID:2AWJD-IT001 IC:26164-IT001 Model Name:IT001, KF001, IT002, IT006, BC001, KF500, WB400, WB100 The above products are applied for FCC ID & IC ID certification. All the models are of the same circuit and RF module, except the battery capacity, appearance shape and model No., IT006, KF500 battery capacity is 75mAh, and IT001, KF001, IT002, BC001, WB400, WB100 battery capacity is 220mAh. Dated :2020-06-16 By: _________ __________ Peter Egli ___ Signature Printed Title: CEO

External Photos

1 - Page 1 of 4 - Report No.: MTi19102108-4E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China APPENDIX 1: EUT PHOTO Photo 1 (For model IT001) Photo 2 1 - Page 2 of 4 - Report No.: MTi19102108-4E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 3 Photo 4 1 - Page 3 of 4 - Report No.: MTi19102108-4E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 5 Photo 6 1 - Page 4 of 4 - Report No.: MTi19102108-4E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 7 ----END OF REPORT----

ID Label/Location Info

   !"#$%&'!" 

Internal Photos

1 - Page 1 of 2 - Report No.: MTi19102108-4E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China APPENDIX 1: EUT PHOTO Photo 1 (For model IT001) Photo 2 PCB antenna 1 - Page 2 of 2 - Report No.: MTi19102108-4E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 3 Photo 4 ----END OF REPORT---- 1 - Page 1 of 7 - Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 1 (For model BC001) 1 - Page 2 of 7 - Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 2 (For model IT002) 1 - Page 3 of 7 - Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 3 (For model IT006) 1 - Page 4 of 7 - Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 4 (For model KF001) 1 - Page 5 of 7 - Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 5 (For model KF500) 1 - Page 6 of 7 - Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 6 (For model WB100) 1 - Page 7 of 7 - Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photo 7 (For model WB400)

RF Exposure Info

This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen Microtest Co., Ltd. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China RF EXPOSURE REPORT FCC ID: 2AWJD-IT001 Date of issue: June 11, 2020 Report Number: MTi19102108-4E2 Sample Description: TWHBC01 IT001 tag Model(s): IT001, KF001, IT002, IT006, BC001, KF500, WB400, WB100 Applicant: Tatwah SA Address: Rue de Lausanne 47, CH-1110 Morges, Switzerland Date of Test: May 22, 2020 to June 11, 2020 Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 4- Report No.: MTi19102108-4E2 TEST RESULT CERTIFICATION Applicant’s name: Tatwah SA Address: Rue de Lausanne 47, CH-1110 Morges, Switzerland Manufacture's name: Tatwah Technology Co., Ltd Address: No.9 Shuiyi South Road Taifeng industrial Park, Xiaolan Town, Zhongshan City, Guangdong, China Product name: TWHBC01 IT001 tag Model and/or type reference: Mango Serial Model: IT001 RF Exposure Procedures: KF001, IT002, IT006, BC001, KF500, WB400, WB100 This device described above has been tested by Shenzhen Microtest Co., Ltd and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. Tested by: Danny Xu June 11, 2020 Reviewed by: Leo Su June 11, 2020 Approved by: Tom Xue June 11, 2020 - Page 3 of 4- Report No.: MTi19102108-4E2 1. Standalone SAR test exclusion considerations Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions. The minimum test separation distance defined in 4.1 f) is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander. To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified, typically in the SAR measurement or SAR analysis report, by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting are required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions. a) For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where  f (GHz) is the RF channel transmit frequency in GHz  Power and distance are rounded to the nearest mW and mm before calculation  The result is rounded to one decimal place for comparison  The values 3.0 and 7.5 are referred to as numeric thresholds in step b) below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm, and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 4.1 f) is applied to determine SAR test exclusion. b) For 100 MHz to 6 GHz and test separation distances > 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following (also illustrated in Appendix B): 1) {[Power allowed at numeric threshold for 50 mm in step a)] + [(test separation distance – 50 mm)·(f(MHz)/150)]} mW, for 100 MHz to 1500 MHz 2) {[Power allowed at numeric threshold for 50 mm in step a)] + [(test separation distance – 50 mm)·10]} mW, for > 1500 MHz and ≤ 6 GHz c) For frequencies below 100 MHz, the following may be considered for SAR test exclusion (also illustrated in Appendix C): 1) For test separation distances > 50 mm and < 200 mm, the power threshold at the corresponding test separation distance at 100 MHz in step b) is multiplied by [1 + log(100/f(MHz))] 2) For test separation distances ≤ 50 mm, the power threshold determined by the equation in c) 1) for 50 mm and 100 MHz is multiplied by ½ 3) SAR measurement procedures are not established below 100 MHz. - Page 4 of 4- Report No.: MTi19102108-4E2 When SAR test exclusion cannot be applied, a KDB inquiry is required to determine SAR evaluation requirements for any SAR test results below 100 MHz to be acceptable. 2. SAR Test Exclusion Thresholds We use 5mm as separation distance to calculate. Bluetooth DTS: Transmit Frequenc y (GHz) Mode Measured Power (dBm) Tune-up power (dBm) Max tune- up Result 1g SAR power(dBm) calculation 2.402 GFSK -3.197 -3±1 -2 0.1956 3 2.440 -2.931 -3±1 -2 0.1972 3 2.480 -2.433 -3±1 -2 0.1987 3 Conclusion: For the max result: 0.1987≤ 3.0 for 1g SAR, No SAR is required. ----END OF REPORT----

Test Report

This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen Microtest Co., Ltd. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Test Report FCC ID:2AWJD-IT001 Date of issue: June 11, 2020 Report number: MTi19102108-4E1 Sample description: TWHBC01 IT001 tag Model(s): IT001, KF001, IT002, IT006, BC001, KF500, WB400, WB100 Applicant: Tatwah SA Address: Rue de Lausanne 47, CH-1110 Morges, Switzerland Date of test: May 22, 2020 to June 11, 2020 Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 41 - Report No.: MTi19102108-4E1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Table of Contents 1. GENERAL INFORMATION ............................................................................................................................... 5 1.1. DESCRIPTION OF EUT ................................................................................................................................................... 5 1.2. OPERATION CHANNEL LIST .............................................................................................................................................. 5 1.3. TEST CHANNEL LIST ....................................................................................................................................................... 6 1.4. ANCILLARY EQUIPMENT LIST ........................................................................................................................................... 6 1.5. DESCRIPTION OF SUPPORT UNITS .................................................................................................................................... 6 2. SUMMARY OF TEST RESULTS ....................................................................................................................... 7 3. TEST FACILITIES AND ACCREDITATIONS .................................................................................................... 8 3.1. TEST LABORATORY ........................................................................................................................................................ 8 3.2. ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 8 3.3. MEASUREMENT UNCERTAINTY ........................................................................................................................................ 8 3.4. TEST SOFTWARE ........................................................................................................................................................... 8 4. EQUIPMENT LIST ............................................................................................................................................. 9 5. TEST RESULT ................................................................................................................................................. 10 5.1. ANTENNA REQUIREMENT ............................................................................................................................................. 10 5.1.1 Standard Requirement ...................................................................................................................................... 10 5.1.2 EUT Antenna ..................................................................................................................................................... 10 5.2. PEAK OUTPUT POWER TEST ......................................................................................................................................... 11 5.2.1 Limit .................................................................................................................................................................. 11 5.2.2 Test setup .......................................................................................................................................................... 11 5.2.3 Test Procedure ................................................................................................................................................... 11 5.2.4 Test Results ........................................................................................................................................................ 11 5.3. CONDUCTED EMISSION ................................................................................................................................................ 14 5.3.1 Limits ................................................................................................................................................................. 14 5.3.2 Test Setup .......................................................................................................................................................... 14 5.3.3 Test Procedure ................................................................................................................................................... 15 5.3.4 Test Results ........................................................................................................................................................ 15 5.4. RADIATED SPURIOUS EMISSION ...................................................................................................................................... 16 5.4.1 Limits ................................................................................................................................................................. 16 5.4.2 Test Setup ...............................…

Text truncated - open the document above for the full version.

Test Setup Photos

Model: IT001 Radiated emission

Contact Information

Applicant

Peter Egli(CEO)
[email protected]+41 21 803 32 34Fax: +41 21 803 32 38

Technical Contact

Shenzhen Microtest Co.,LtdSmith Chen
[email protected]86-755 88850135

Shenzhen · China

Test Firm

Shenzhen Microtest Co., Ltd.Selby Liao
[email protected]0755-88850135-1193

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz600.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.

Other Applications from Tatwah SA

M_26 IT001 TAG - FCC ID 2AWJD-IT001A - Tatwah SA
2AWJD-IT001A

M_26 IT001 TAG

Sep 26, 2023

Equipment Class

DTS - Digital Transmission System
M_26 IT005 PLUS TAG - FCC ID 2AWJD-IT005PLUSA - Tatwah SA
2AWJD-IT005PLUSA

M_26 IT005 PLUS TAG

Sep 26, 2023

Equipment Class

DTS - Digital Transmission System
M_26 IT005 TAG - FCC ID 2AWJD-IT005A - Tatwah SA
2AWJD-IT005A

M_26 IT005 TAG

Sep 26, 2023

Equipment Class

DTS - Digital Transmission System
TWHBC01 IT001 tag - FCC ID 2AWJD-IT005 - Tatwah SA
2AWJD-IT005

TWHBC01 IT001 tag

Jun 21, 2020

Equipment Class

DTS - Digital Transmission System